26 resultados para MOUTHRINSE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to evaluate toothbrush contamination in vivo by Candida spp. and the efficacy of Periogard(A (R)) and Neem Sattiva(A (R)), in spray, in the disinfection of these toothbrushes. This study was performed in three phases in which mouthrinses and sterile distilled water (control group) were sprayed six times on toothbrush bristles used by 61 university students. Toothbrushes were then submitted to microbiological processing for the isolation and identification of Candida species. Fifty-nine students completed the three phases of this study, and 22 (37.3%) control group toothbrushes presented growth of Candida species. Periogard(A (R)) and Neem Sattiva(A (R)) eliminated growth of Candida spp. in 48.1 and 7.4% of toothbrushes, respectively. Contamination by Candida spp. was observed on various toothbrushes of the control group. Periogard(A (R)) was more efficacious than Neem Sattiva(A (R)) in eliminating growth of Candida spp. on the toothbrush bristles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the surface integrity of sutures after immersion in mouthrinse or water, by scanning electron microscopy (SEM) analysis. Pieces of resorbable suture remaining after oral surgery were immediately collected. Twelve pieces each of catgut, chromed catgut, and polyglactin 910 were divided into four groups and immersed in pure mouthrinse, mouthrinse diluted in water at 1:1 and 1:2, or water (positive control), for 24 h. Three pieces each of new sutures were used as negative control. Specimens were placed on stubs and sputter coated with gold for SEM analysis. Observation of experimental groups and comparison with controls revealed that immersion in the mouthrinse at different dilutions did not alter their surface; slight, nonsignificant changes were found in some experimental specimens yet also in the positive control group. It was concluded that immersion of resorbable sutures in water or non-alcoholic benzydamine hydrochloride mouthrinse did not produce any significant change; therefore, this mouthrinse may be safely employed after oral surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This in situ/ex vivo study evaluated whether a rinse with an iron solution could reduce wear and the percentage of microhardness change of human enamel and dentine submitted to erosion followed by brushing after 1 or 30 min.Design: During 2 experimental 5-day crossover phases (wash-out period of 10 days), 10 volunteers wore intraoral palatal devices, with 12 specimens (6 of enamel and 6 of dentine) arranged in 3 horizontal rows (4 specimens each). In one phase, the volunteers immersed the device for 5 min in 150 mL of cola drink, 4 times a day. Immediately after immersion, no treatment was performed in one row. The other row was brushed after 1 min using a fluoride dentifrice and the device was replaced into mouth. After 30 min, the remaining row was brushed. In the other phase, the procedures were repeated, but after immersion the volunteers rinsed for 1 min with 10 mL of a 10 mM ferrous sulphate solution. Changes in surface microhardness (%SMH) and wear (profilometry) of enamel and dentine were measured. Data were tested using ANOVA and Tukey's tests (p < 0.05).Results: the enamel presented more wear than dentine, under all experimental conditions. The iron solution caused a significant reduction on the %SMH in enamel, and a significant reduction on the wear in dentine, regardless the other conditions.Conclusions: Rinsing with an iron solution after an erosive attack, followed or not by an abrasive episode, may be a viable alternative to reduce the loss of dental structure. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite resin is a dental material susceptible to color change over time which limits the longevity of restorations made with this material. The influence of light curing units and different fluoride mouthrinses on superficial morphology and color stability of a nanofilled composite resin was evaluated. Specimens (N = 150) were prepared and polished. The experimental groups were divided according to the type of light source (halogen and LED) and immersion media (artificial saliva, 0.05% sodium fluoride solution-manipulated, Fluordent Reach, Oral B, Fluorgard). Specimens remained in artificial saliva for 24-h baseline. For 60 days, they were immersed in solutions for 1 min. Color readout was taken at baseline and after 60 days of immersion. Surface morphology was analyzed by Scanning Electron Microscopy (SEM) after 60 days of immersion. Color change data were submitted to two-way Analysis of Variance and Tukey tests (α = 0.05). Surface morphology was qualitatively analyzed. The factor light source presented no significant variability (P = 0.281), the immersion media, significant variability (P < 0.001) and interaction between factors, no significant variability (P = 0.050). According to SEM observations, no difference was noted in the surface of the specimens polymerized by different light sources, irrespective of the immersion medium. It was concluded that the light source did not influence the color stability of composite, irrespective of the immersion media, and among the fluoride solutions analyzed, Fluorgard was the one that promoted the greatest color change, however, this was not clinically perceptible. The immersion media did not influence the morphology of the studied resin. Microsc. Res. Tech. 77:941–946, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Chlorhexidine (CHX) rinsing after periodontal surgery is common. We assessed the clinical and microbiological effects of two CHX concentrations following periodontal surgery. MATERIALS AND METHODS: In a randomized, controlled clinical trial, 45 subjects were assigned to 4 weeks rinsing with a 0.05 CHX/herbal extract combination (test) or a 0.1% CHX solution. Clinical and staining effects were studied. Subgingival bacteria were assessed using the DNA-DNA checkerboard. Statistics included parametric and non-parametric tests (p<0001 to declare significance at 80% power). RESULTS: At weeks 4 and 12, more staining was found in the control group (p<0.05 and p<0.001, respectively). A higher risk for staining was found in the control group (crude OR: 2.3:1, 95% CI: 1.3 to 4.4, p<0.01). The absolute staining reduction in the test group was 21.1% (9 5% CI: 9.4-32.8%). Probing pocket depth (PPD) decreases were significant (p<0.001) in both groups and similar (p=0.92). No rinse group differences in changes of bacterial counts for any species were found between baseline and week 12. CONCLUSIONS: The test CHX rinse resulted in less tooth staining. At the study endpoint, similar and high counts of periodontal pathogens were found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this study were to evaluate the incidence of mutans streptococci (MS - sessile form) on complete maxillary dentures after use of a specific denture paste, and to determine the minimum inhibitory concentration (MIC) and maximum inhibitory dilution (MID) of 3 oral mouthrinses: Cepacol, Plax and Periogard. Seventy-seven complete denture wearers were randomly assigned into 2 groups, according to the product used for denture cleaning: Control group - conventional dentifrice (Kolynos-Super White); and Test group: experimental denture cleaning paste. Denture biofilm was collected at baseline and after 90 and 180 days after treatment by brushing the dentures with saline solution. After decimal serial dilution, samples were seeded onto agar sucrose bacitracin to count colonies with morphological characteristics of MS. MS identification was performed by the sugar fermentation tests. After this procedure, brain heart infusion broth (BHI) was added to oral mouthrinses (Plax, Cepacol e Periogard) and seeded on Petri dishes. The colonies were seeded using the Steers multiplier and, after the incubation, the MIC and MID of the mouthrinses were calculated. The results showed an incidence of 74.0% (n=57) of MS in the 77 complete dentures examined in the study, being 76.3% (n=29) of the Control group (conventional dentifrice) and 71.8% (28) of the Test group (experimental denture cleaning paste). In both groups, the number of positive cases for MS decreased from day 0 to day 180. In the Test group there was a slight decrease in the incidence of Streptococcus mutans 90 days after use of the experimental denture cleaning paste, which was not observed in the Control group. As regards to mouthrinses, for both groups, Periogard showed antimicrobial action with the highest dilution, followed by Cepacol and Plax. In conclusion, the incidence of MS in complete dentures was high and Periogard was the mouthrinse with the strongest antimicrobial action against MS. The experimental denture cleaning paste showed a slight action against S. mutans after 90 days of treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports the isolation of the sesquiterpene lactone 15-deoxygoyazensolide from the stems of Minasia alpestris and the evaluation of its antimicrobial activity against the following oral pathogens: Enterococcus faecalis, Streptococcus salivarius, Streptococcus sobrinus, Streptococcus mutans, Streptococcus mitis, Streptococcus sanguinis, and Lactobacillus casei. Despite the cytotoxicity and genotoxicity of other sesquiterpene lactones of the furanoheliangolide-type, our results revealed that this compound exhibits low antibacterial activity against the evaluated oral pathogens; however, an interesting selectivity against E. faecalis (minimum inhibitory concentration [MIC] = 40 mu g mL(-1)) and S. sobrinus (MIC = 60 mu g mL(-1)) was observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Caries is a plaque-associated multifactorial chronic disease. Oral hygiene habits, sugar, and oral micobiota interactions are important for caries to occur. Xylitol has been shown to reduce caries mainly due to its effects on mutans streptococci (MS). The purpose of this study was to evaluate the relationship of daily oral health habits and bacterial level on the caries occurrence and to study the effect of xylitol on the composition of oral microflora. A total of 192, 10-12 years old, male school children had been screened for salivary MS. Healthy subjects with high MS counts participated in two parallel double-blinded, randomised, controlled trials. In the first 5-week trial, subjects were assigned into xylitol (n=35) and sorbitol gum (n=38) groups. At baseline, children were examined using International Caries Detection and Assessment System (ICDAS) criteria and interviewed for oral health habits. In the second 4-week trial, subjects were assigned into xylitol (n=25) and saccharine mouthrinse (n=25) groups. In the end of both interventions, saliva samples were collected. The samples were analysed for changes in MS counts and changes in the composition of the oral microbiota assessed by the Human Oral Microbe Identification Microarray (HOMIM). Relationships between daily habits, bacterial levels and caries were evaluated. Daily use of sweets and soft drinks were the habits significantly associated with caries severity measured by ICDAS Caries Index (CI), while toothbrushing was the only habit associated with the low caries severity. Abiotrophia defectiva and Actinomyces meyeri/ A. odontolyticus were significantly higher in caries-affected children while Shuttleworthia satelles was significantly higher in caries-free children. Xylitol showed significant reduction in salivary levels of MS in both trials. No significant effects on other members of the microbiota were found when evaluated by HOMIM. In conclusion, other members of oral microbiota than MS may be associated with caries occurrence or absence. The use of xylitol had significant effect on MS with no effects on the other members of the salivary microbiota.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectif : il a été rapporté que l’utilisation d’agents prophylactiques fluorés pouvait favoriser la corrosion galvanique au sein des alliages de titane. L’objectif de la présente étude était d’évaluer l’effet d’un rince-bouche fluoré sur les propriétés mécaniques de fils en nickel-titane (NiTi) et de fils en cuivre-nickel-titane (CuNiTi) lorsque ces derniers sont couplés à des boîtiers de compositions différentes (boîtiers de marques Smartclip, Clarity, et Sprint). Matériels et Méthodes : 90 segments de fils en NiTi et 90 segments de fils en CuNiTi ont été chacun couplés à 2 boîtiers de chaque marque. Chaque assemblage fil-boîtiers a été par la suite incubé pendant 3 heures à 37°C, soit dans une solution de fluore neutre (Fluorinse™ 0,05% NaF), soit dans une solution de salive artificielle (solution contrôle). Suite à l’incubation, les échantillons étaient nettoyés avec de l’eau déshydrogénée, les fils séparés des boîtiers et montés sur un support pour subir un test de pliage en trois points en milieu humide (salive artificielle) à 37°C. Les modules d’élasticité ainsi que les limites conventionnelles d’élasticité en activation et en désactivation ont été mesurés et comparés. Des analyses de Variance (ANOVA) et des comparaisons post-hoc avec la correction de Bonferronni ont été utilisées pour comparer les groupes entre eux (α = 0,05). Résultats : L’utilisation d’un rince-bouche fluoré a produit une réduction du module d’élasticité et de la limite conventionnelle d’élasticité en activation et en désactivation pour les fils en NiTi ; cependant, cet effet a été modulé par le type de boîtier auquel le fil a été couplé. Les propriétés mécaniques de fils en CuNiTi n’ont pas été affectées par le fluor, ou par le type de boîtier utilisé. Conclusions : L’utilisation d’un rince-bouche fluoré modifie les propriétés mécaniques des fils en NiTi seulement. Cet effet est modulé par le boîtier auquel le fil en NiTi est couplé. A la différence des autres études publiées dans la littérature, nos résultats ne nous permettent pas de conclure que la modification des propriétés mécaniques des fils en NiTi entrainerait obligatoirement un allongement de la durée du traitement orthodontique. Mots clés : Fluor, fils nickel-titane, boîtiers orthodontiques, corrosion galvanique, propriétés mécaniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this clinical study was to evaluate the effectiveness of the toothbrushing with and without fluoride and the daily fluoride rinse (NaF 0.05%) on produced white spot, in vivo. This was a clinical study, controlled, randomized and triple blind. Thirty patients were selected for orthodontics reasons from Orthodontics Specialization Course at the Brazilian Dental Association - Section of Rio Grande do Norte. In this study it was used 4 bicuspid upper and lower. They had orthodontic reason for extractions, in 35 days, at least. The sample had one hundred and twenty teeth that received orthodontic bands. The bands were fixed with polycarboxylate cement, and there was a space standardized between bands and one surface of teeth. The four bicuspid of each patients were randomized and nominated as A, B, C and D. These nominations determinated the sequence of the extractions and what was done in each tooth. All the patients had been submitted to the toothbrushing with or without fluoride for 35 days. After this period, the A tooth of each patient was extracted to serve as control. The others teeth (B, C and D) were extracted one by each week. The entire sample was analyzed through the clinical examination and by laser fluorescence (DIAGNOdent®) in three different times: before orthodontic bands, 28 days after fixed and then removed the bands and, the last one, 07 days after one of the three treatments (toothbrushing with or without fluoride, tooth paste with fluoride and mouth rinse with fluoride). At the beginning all groups (A, B, C and D) had the same conditions, no significant difference was found. The same situation was found in a clinical examination. The results of the DIAGNOdent® for the groups that used tooth paste without fluoride, with fluoride and mouth rinse with fluoride, after 28 days, there was no significant difference. Clinically, the white spot was formed in all teeth after 28 days. When it was compared the three treated groups, the group without fluoride in tooth paste had worst result than the others groups. But there was no significant association between the number of active and inactive white spots and the type of treatment that the teeth had received. The demineralization of the enamel surface, under the orthodontic bands, it happened in a few weeks. The exposition of the white spots in oral environmental resulted in an improvement, but it was not enough to return to the values from the base line, either for the toothbrushing and/or the use of fluorite mouth rinse. Mouth rinse and toothpaste with fluoride have showed to reduce the incidence of demineralization in the enamel, but none seems to be superior to another one in an in vivo study

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was evaluate the effectiveness of the chitosan at 0.4 with high molecular weight and high deacetylation degree mouthrinse over the total decrease of the streptococci, Streptococcus mutans, lactobaci/li and over the perceptible bacterial film and gingival bleeding indices. For that, a total of 68 healthy students between 11 and 13 years old, not allergic to crustacean and not users of antibiotics or antimicrobial agent for the last three months or during the treatment, was selected. From those, thirty two individuaIs used the mouthrinse test, and thirty six, the control one. The participants rinsed 10 mL of the solutions twice a day, one during the moming (which was supervised), and another one during the aftemoon (which was not supervised), for fifteen days. The saliva collect for the microbiological analysis, as well as the perceptible bacterial film and gingival bleeding indices check, were made before the use ofthe mouthrinses (base line), immediately after the last mouthrinse on the day (zero time) and fifteen days after (fifteen time). These data were collected at school and the saliva was carried inside the ice to the laboratory. The samples were diluted, and 0.1 mL ofthe 10 -1 dilution was seeded in Rogosa SL agar, for further analysis of the total of lactobaci/lus~ 0.1 mL of the 10-4 dilution in Mitis Salivarius with bacitracin, for S. mutans analysis; and 0.1 mL of the 10-6 dilution in Mitis Salivarius for the analysis ofthe total of streptococcus. The Rogosa SL agar plates were incubated in aerobic at 37°C for 72 hours and the MSB and the MS were incubated in anaerobic in Gaspak@ jars at 37°C for 48 hours for further count ofColonies Former Units (CFUs). The assay was made in duplicate for each bacterial group analyzed. The number of CFUs transformed in LOGlO was analyzed according to the following tests: ANOV A, t of Paired and Not Paired Student, Friedman, Man-Whitney and square-qui test. On the base line, alI the variables analyzed were similar on both tested groups. On both groups, for the total of streptococcus there was no significant difference along the time and for S. mutans there was a statistic significant increase of the CFUs from the base line to the zero time. For the total of lactobaccilus there was no significant difference on the test group along the time, and on the control there was a significant increase ofthe CFUs ITom the base line to the zero time. For both groups, there was significant decrease ofthe perceptible bacterial film index along the time, and that can be explained by the mechanic effect of the mouthrinse over the bacterial film and by the participation of the students on the research which could have motivated him to a better toothbrushing (Hawthome effect). The gingival bleeding index also showed a decrease along the time, even though it was not significant. Therefore, the conclusion of this study was that the chitosan at 0.4 % mouthrinse was not effective on the CFUs reduction of the three bacterial groups analyzed, as well as on the reduction of the perceptible bacterial film and gingival bleeding indices

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the influence of fluoride-containing mouthrinse solutions (Fluorgard and Oral B) on the superficial microhardness of two resin-modified glass ionomer cements (Vitremer and Fuji II LC). Fifteen discs-shaped specimens of each glass ionomer cement (0 10 mm; 2 mm thick) were prepared, thereby forming two groups. After 24-hour storage in artificial saliva, the microhardness was measure and the data were recorded. Next, each group was divided into three subgroups (n = 5), according to the solution to be immersed in. Control specimens were kept in artificial saliva along the whole experiment. The test specimens were kept in mouthrinse solution for 30 days. Vickers surface microhardness was analyzed at predetermined evaluation periods: 24 h, 48 h, 7, 14, 21 and 30 days after specimens' preparation. Data were subjected to three-way ANOVA and to Tukey test (p < 0.05). A better behavior of Fuji II LC was observed and Fluorgard affected most the characteristics of the tested materials. It may be concluded that fluoride-containing solutions influenced the tested characteristics of materials, mainly of Vitremer.