1000 resultados para MM-HEMT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

AlGaN/GaN high electron mobility transistors (HEMT) are key devices for the next generation of high-power, high-frequency and high-temperature electronics applications. Although significant progress has been recently achieved [1], stability and reliability are still some of the main issues under investigation, particularly at high temperatures [2-3]. Taking into account that the gate contact metallization is one of the weakest points in AlGaN/GaN HEMTs, the reliability of Ni, Mo, Pt and refractory metal gates is crucial [4-6]. This work has been focused on the thermal stress and reliability assessment of AlGaN/GaN HEMTs. After an unbiased storage at 350 o C for 2000 hours, devices with Ni/Au gates exhibited detrimental IDS-VDS degradation in pulsed mode. In contrast, devices with Mo/Au gates showed no degradation after similar storage conditions. Further capacitance-voltage characterization as a function of temperature and frequency revealed two distinct trap-related effects in both kinds of devices. At low frequency (< 1MHz), increased capacitance near the threshold voltage was present at high temperatures and more pronounced for the Ni/Au gate HEMT and as the frequency is lower. Such an anomalous “bump” has been previously related to H-related surface polar charges [7]. This anomalous behavior in the C-V characteristics was also observed in Mo/Au gate HEMTs after 1000 h at a calculated channel temperatures of around from 250 o C (T2) up to 320 ºC (T4), under a DC bias (VDS= 25 V, IDS= 420 mA/mm) (DC-life test). The devices showed a higher “bump” as the channel temperature is higher (Fig. 1). At 1 MHz, the higher C-V curve slope of the Ni/Au gated HEMTs indicated higher trap density than Mo/Au metallization (Fig. 2). These results highlight that temperature is an acceleration factor in the device degradation, in good agreement with [3]. Interface state density analysis is being performed in order to estimate the trap density and activation energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the potential of 980-nm gallium aluminum arsenide (GaAlAs) and 1064-nm neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers to reduce bacteria after irradiation of implant surfaces contaminated with Enterococcus faecalis and Porphyromonas gingivalis and on irradiated implant surface morphology. Background: Despite the frequency of implant success, some implant loss is related to peri-implantitis because of difficulty in eliminating the biofilm. Methods: Implants (3.75 x 13 mm) with machined surfaces, surfaces sand blasted with titanium oxide (TiO(2)), and sand-blasted and acid-etched surfaces were exposed to P. gingivalis and E. faecalis cultures and irradiated with 980-nm GaAlAs or 1064-nm Nd: YAG lasers. After laser treatments, the number of remaining colony-forming units and implant surface morphology were analyzed using scanning electron microscopy (SEM). Results: The Nd: YAG laser was able to promote a total contamination reduction on all implants irradiated. The results with the GaAlAs laser showed 100% bacteria reduction on the implants irradiated with 3 W. Irradiation with 2.5 W and 3 W achieved 100% of bacteria reduction on P. gingivalis-contaminated implants. Decontamination was not complete for the sand-blasted TiO(2) (78.6%) and acid-etched surfaces (49.4%) contaminated with E. faecalis and irradiated with 2.5 W. SEM showed no implant surface changes. Conclusion: The wavelengths used in this research provided bacteria reduction without damaging implant surfaces. New clinical research should be encouraged for the use of this technology in the treatment of peri-implantitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solvent effects on the low-lying absorption spectrum and on the (15)N chemical shielding of pyrimidine in water are calculated using the combined and sequential Monte Carlo simulation and quantum mechanical calculations. Special attention is devoted to the solute polarization. This is included by an iterative procedure previously developed where the solute is electrostatically equilibrated with the solvent. In addition, we verify the simple yet unexplored alternative of combining the polarizable continuum model (PCM) and the hybrid QM/MM method. We use PCM to obtain the average solute polarization and include this in the MM part of the sequential QM/MM methodology, PCM-MM/QM. These procedures are compared and further used in the discrete and the explicit solvent models. The use of the PCM polarization implemented in the MM part seems to generate a very good description of the average solute polarization leading to very good results for the n-pi* excitation energy and the (15)N nuclear chemical shield of pyrimidine in aqueous environment. The best results obtained here using the solute pyrimidine surrounded by 28 explicit water molecules embedded in the electrostatic field of the remaining 472 molecules give the statistically converged values for the low lying n-pi* absorption transition in water of 36 900 +/- 100 (PCM polarization) and 36 950 +/- 100 cm(-1) (iterative polarization), in excellent agreement among one another and with the experimental value observed with a band maximum at 36 900 cm(-1). For the nuclear shielding (15)N the corresponding gas-water chemical shift obtained using the solute pyrimidine surrounded by 9 explicit water molecules embedded in the electrostatic field of the remaining 491 molecules give the statistically converged values of 24.4 +/- 0.8 and 28.5 +/- 0.8 ppm, compared with the inferred experimental value of 19 +/- 2 ppm. Considering the simplicity of the PCM over the iterative polarization this is an important aspect and the computational savings point to the possibility of dealing with larger solute molecules. This PCM-MM/QM approach reconciles the simplicity of the PCM model with the reliability of the combined QM/MM approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents new experimental flow boiling heat transfer results in micro-scale tubes. The experimental data were obtained in a horizontal 2.3 mm I.D stainless steel tube with heating length of 464 mm, R134a and R245fa as working fluids, mass velocities ranging from 50 to 700 kg m(-2) s(-1), heat flux from 5 to 55 kW m(-2), exit saturation temperatures of 22, 31 and 41 degrees C, and vapor qualities ranging from 0.05 to 0.99. Flow pattern characterization was also performed from images obtained by high-speed filming. Heat transfer coefficient results from 1 to 14 kW m(-2) K(-1) were measured. It was found that the heat transfer coefficient is a strong function of heat flux, mass velocity and vapor quality. The experimental data were compared against ten flow boiling predictive methods from the literature. Liu and Winterton [3], Zhang et al. [5] and Saitoh et al. [6] worked best for both fluids, capturing most of the experimental heat transfer trends. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aims of this study were to analyze the overall survival of patients with cirrhosis and small hepatocellular carcinoma (HCC) and identify independent pretreatment predictors of survival in Brazil. Methods: Between 1998 and 2003, 74 patients with cirrhosis and small HCC were evaluated. Predictors of survival were identified using the Kaplan-Meier survival curves and the Cox model. Results: The overall survival rates were 80%, 41%, and 17% at 12, 36, and 60 months, respectively. The mean length of follow-up after HCC diagnosis was 23 months (median 22 mo, range: I to 86 mo) for the entire group. Univariate analysis showed that model for endstage liver disease (MELD) score (P = 0.016), Child-Pugh classification (P = 0.007), alpha-fetoprotein level (P = 0.006), number of nodules (P = 0.041), tumor diameter (P = 0.009), and vascular invasion (P < 0.0001) were significant predictors Of Survival. Cox regression analysis identified vascular invasion (relative risk = 14.60, confidence interval 95% = 3.3-64.56, P < 0.001) and tumor size > 20 mm (relative risk = 2.14, confidence interval 95% = 1.07-4.2, P = 0.030) as independent predictors of decreased survival. Treatment of HCC was related to increased overall survival. Conclusions: Identification of HCC smaller than 20 mm is associated with longer survival. Presence of vascular invasion, even in small tumors, maybe associated with poor prognosis. Treatment of small tumors Of LIP to 20 mm diameter is related to increased survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo visa caracterizar e comparar técnicas de detecção de fugas de água, aplicadas a tubagens em pressão, em serviço e de diâmetro superior a 350 mm. Este trabalho justifica-se pela elevada percentagem de perdas hídricas reportados ao IRAR pelas entidades gestoras do sector, que no ano de 2008 atingiu o valor de 37%, bastante superior ao limite máximo definido por esta entidade reguladora (15%). Tendo em conta este dado, conclui-se que o combate às perdas de água continua a ser uma linha estratégica primordial para as entidades gestoras, constituindo a inspecção de tubagens, uma das actividades importantes neste contexto. Actualmente, a actividade de inspecção de tubagens de água usufrui de um leque diversificado de técnicas de inspecção. Algumas dessas técnicas podem ser aplicadas em tubagens de gás, de águas residuais e de abastecimento de água. Neste estudo apresentam-se três técnicas de inspecção de tubagens utilizadas em condutas de abastecimento de água - a técnica de inspecção visual, a técnica Smartball e a técnica Sahara - e compara-se duas: a técnica Sahara e a técnica Smartball. É no âmbito da conclusão deste trabalho, que se aborda a técnica Sahara, apresentando um caso concreto da sua aplicação, realizado na EPAL, S.A., em condutas de adução de diâmetro superior a 350 mm. A aplicação da técnica Sahara na EPAL em 2007 e 2008 promoveu a queda do valor das perdas reais e anuais reportadas à entidade reguladora. Após a inspecção com recurso a esta técnica, a empresa poupou mais de 640000 m3/ano. Este valor equivale a cerca de 3 dias de consumo de água no município de Lisboa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A batalha é geralmente considerada como um dos géneros mais característicos da literatura organística ibérica do Barroco. Paradoxalmente é, de todas os géneros da música de órgão peninsular, aquele acerca do qual se possuem menos dados sobre a prática interpretativa. A informação que se pode obter a partir da generalidade dos textos seiscentistas sobre música de tecla, aplica-se sobretudo à interpretação das obras contrapontísticas, deixando em aberto muitas questões relacionadas com o carácter eminentemente descritivo das batalhas. Por outro lado, é também interessante verificar que algumas das mais convincentes interpretações de batalhas que actualmente escutamos são aquelas que resultam de uma leitura menos literal do texto musical e de uma intenção clara de sublinhar o seu carácter descritivo. A informação extraída da Batalha famoza (presente no manuscrito MM 43 da Biblioteca Pública Municipal do Porto) e apresentada ao longo deste texto parece pôr em evidência o apelo que a execução das batalhas fazia a um esforço interpretativo por parte do organista, não só através da utilização de recursos específicos do órgão ibérico, mas também mediante o emprego de uma ornamentação mais livre que pusesse em evidência o carácter descritivo daquele género musical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Trabalho prospectivo, randomizado para comparar a eficácia e a segurança do cateter irrigado em relação ao cateter com eletrodo distal de 8 mm para ablação com radiofreqüência (RF) do flutter atrial. MÉTODOS: Em 52 pacientes consecutivos referidos para tratamento do flutter atrial típico, a ablação do istmo cavotricuspídeo (Ist-CT) foi realizada com cateter de irrigação fechada (n=26) ou com cateter de eletrodo distal de 8 mm (n=26). Os pulsos de RF foram aplicados ponto a ponto por 60 segundos com potência limitada a 50 w com o cateter irrigado e por controle de temperatura (60ºC, 70 w) com cateter de 8 mm. O critério de fim do procedimento foi a obtenção de bloqueio bidirecional do Ist-CT. RESULTADOS: O bloqueio Ist-CT foi obtido em 98,1% dos pacientes. O "crossover" ocorreu em quatro pacientes do grupo com cateter irrigado. Não se encontrou diferença estatística significante em relação aos parâmetros da ablação, tais como tempo total de aplicação de RF (591,1±309,0s vs 486,2±250,8s), duração do procedimento (86,4 ± 23,6 vs 78,1±22,5min) e tempo de fluoroscopia (17,0±6,7 vs 15,4±4,6min) entre os dois grupos. Durante seguimento médio de 10,6 meses, um paciente do grupo irrigado apresentou recorrência do flutter atrial típico. CONCLUSÃO: A ablação do Ist-CT resultou ser efetiva e segura para o controle do flutter atrial com ambas as técnicas empregadas (cateter com eletrodo distal de 8 mm e cateter irrigado). A complexidade técnica do cateter irrigado proporciona menor competitividade.