980 resultados para MASS SCREENING
Resumo:
BACKGROUND The distribution of the enzymopathy glucose-6-phosphate dehydrogenase (G6PD) deficiency is linked to areas of high malaria endemicity due to its association with protection from disease. G6PD deficiency is also identified as the cause of severe haemolysis following administration of the anti-malarial drug primaquine and further use of this drug will likely require identification of G6PD deficiency on a population level. Current conventional methods for G6PD screening have various disadvantages for field use. METHODS The WST8/1-methoxy PMS method, recently adapted for field use, was validated using a gold standard enzymatic assay (R&D Diagnostics Ltd ®) in a study involving 235 children under five years of age, who were recruited by random selection from a cohort study in Tororo, Uganda. Blood spots were collected by finger-prick onto filter paper at routine visits, and G6PD activity was determined by both tests. Performance of the WST8/1-methoxy PMS test under various temperature, light, and storage conditions was evaluated. RESULTS The WST8/1-methoxy PMS assay was found to have 72% sensitivity and 98% specificity when compared to the commercial enzymatic assay and the AUC was 0.904, suggesting good agreement. Misclassifications were at borderline values of G6PD activity between mild and normal levels, or related to outlier haemoglobin values (<8.0 gHb/dl or >14 gHb/dl) associated with ongoing anaemia or recent haemolytic crises. Although severe G6PD deficiency was not found in the area, the test enabled identification of low G6PD activity. The assay was found to be highly robust for field use; showing less light sensitivity, good performance over a wide temperature range, and good capacity for medium-to-long term storage. CONCLUSIONS The WST8/1-methoxy PMS assay was comparable to the currently used standard enzymatic test, and offers advantages in terms of cost, storage, portability and use in resource-limited settings. Such features make this test a potential key tool for deployment in the field for point of care assessment prior to primaquine administration in malaria-endemic areas. As with other G6PD tests, outlier haemoglobin levels may confound G6PD level estimation.
Resumo:
Introduction: Cervical and breast cancer are the most common malignancies among women worldwide. Effective screening can facilitate early detection and dramatically reduce mortality rates. The interface between those screening patients and patients most needing screening is complex, and women in remote areas of rural counties face additional barriers that limit the effectiveness of cancer prevention programs. This study compared various methods to improve compliance with mass screening for breast and cervical cancer among women in a remote, rural region of Brazil. Methods: In 2003, a mobile unit was used to perform 10 156 mammograms and Papanicolaou smear tests for women living in the Barretos County region of Sao Paulo state, Brazil (consisting of 19 neighbouring cities). To reach the women, the following community outreach strategies were used: distribution of flyers and pamphlets; media broadcasts (via radio and car loudspeakers); and community healthcare agents (CHCAs) making home visits. Results: The most useful intervention appeared to be the home visits by healthcare agents or CHCAs. These agents of the Family Health Programme of the Brazilian Ministry of Health reached an average of 45.6% of those screened, with radio advertisements reaching a further 11.9%. The great majority of the screened women were illiterate or had elementary level schooling (80.9%) and were of 'poor' or 'very poor' socioeconomic class (67.2%). Conclusions: Use of a mobile screening unit is a useful strategy in developing countries where local health systems have inadequate facilities for cancer screening in underserved populations. A multimodal approach to community outreach strategies, especially using CHCAs and radio advertisements, can improve the uptake of mass screening in low-income, low-educational background female populations.
Resumo:
To analyse breast cancer incidence trends in New South Wales (NSW), Australia, in relation to population-based mammography screening targeting women aged 50 to 69 years. Trends in age-specific incidence of invasive breast cancers in NSW women aged >= 40 years were examined in relation to mammography screening rates and screening cancer detection rates. Incidence of invasive breast cancer in NSW women increased in all age-groups over 1972 to 2002. The incidence trend for women aged 50 to 69 years showed that the steepest rise was associated with increased participation in population-based mammography screening, which was implemented from 1988 and achieved state-wide coverage in 1995. The elevated incidence of invasive cancer significantly exceeded pre-screening levels, and persisted after rates of initial screens declined. This elevated incidence was sustained by the contribution of cancers diagnosed through subsequent screening, and resulted from increased cancer detection rates in subsequent screens. The recent increase in invasive breast cancer incidence in NSW is associated with mammography screening, and occurred mostly in the target age-group women. Persistence of higher incidence after 1994 was not explicable by inflation of cancer incidence due to detection of prevalent screen cases, but was associated with a trend of increased cancer detection rates in subsequent screening rounds, probably consequent to quality improvements in mammography screening diagnosis.
Resumo:
High-throughput screening (HTS) using high-density microplates is the primary method for the discovery of novel lead candidate molecules. However, new strategies that eschew 2D microplate technology, including technologies that enable mass screening of targets against large combinatorial libraries, have the potential to greatly increase throughput and decrease unit cost. This review presents an overview of state-of-the-art microplate-based HTS technology and includes a discussion of emerging miniaturized systems for HTS. We focus on new methods of encoding combinatorial libraries that promise throughputs of as many as 100 000 compounds per second.
Resumo:
OBJECTIVE: To assess the usefulness of corneal esthesiometry for screening diabetic retinopathy. METHODS: A cross-sectional study was carried out comprising 575 patients attending a diabetic retinopathy-screening program in the city of São Paulo. Corneal esthesiometry was assessed with the Cochet-Bonnet esthesiometer. The presence of diabetic retinopathy was detected with indirect fundoscopy. The validity of corneal esthesiometry in identifying diabetic retinopathy was evaluated by the Receiver Operating Characteristic (ROC) curve. RESULTS: Sensitivity and specificity analyses of the corneal esthesiometry for detecting the stages of diabetic retinopathy using different cut-offs showed values less than 80%. The best indices (72.2% sensitivity and 57.4% specificity) were obtained for the identification of patients with proliferative diabetic retinopathy. CONCLUSIONS: In the study series, corneal esthesiometry was not a good indicator of diabetic retinopathy.
Resumo:
OBJECTIVE To analyze the coverage of a cervical cancer screening program in a city with a high incidence of the disease in addition to the factors associated with non-adherence to the current preventive program.METHODS A cross-sectional study based on household surveys was conducted. The sample was composed of women between 25 and 59 years of age of the city of Boa Vista, RR, Northern Brazil who were covered by the cervical cancer screening program. The cluster sampling method was used. The dependent variable was participation in a women’s health program, defined as undergoing at least one Pap smear in the 36 months prior to the interview; the explanatory variables were extracted from individual data. A generalized linear model was used.RESULTS 603 women were analyzed, with an mean age of 38.2 years (SD = 10.2). Five hundred and seventeen women underwent the screening test, and the prevalence of adherence in the last three years was up to 85.7% (95%CI 82.5;88.5). A high per capita household income and recent medical consultation were associated with the lower rate of not being tested in multivariate analysis. Disease ignorance, causes, and prevention methods were correlated with chances of non-adherence to the screening system; 20.0% of the women were reported to have undergone opportunistic and non-routine screening.CONCLUSIONS The informed level of coverage is high, exceeding the level recommended for the control of cervical cancer. The preventive program appears to be opportunistic in nature, particularly for the most vulnerable women (with low income and little information on the disease). Studies on the diagnostic quality of cervicovaginal cytology and therapeutic schedules for positive cases are necessary for understanding the barriers to the control of cervical cancer.
Resumo:
BACKGROUND/AIMS: In Portugal, so far, there is no study or even accurate data on the prevalence of diabetic retinopathy (DR), based on a large representative sample and on a long-term follow-up. The objective of our study was to determine the prevalence of DR based on a national screening community-based programme. METHODS: A 5-year retrospective analysis of the RETINODIAB screening programme results was implemented in Lisbon and Tagus Valley area between July 2009 and October 2014. We estimated the prevalence of retinopathy for all patients with type 2 diabetes and studied the association between known risk factors and retinopathy emergence at their first screening. RESULTS: Throughout this period, from a total of 103 102 DR readable screening examinations, 52 739 corresponded to patients who attended RETINODIAB screening at entry. Globally, DR was detected in 8584 patients (16.3%). Of these, 5484 patients (10.4%) had mild non-proliferative (NP) DR, 1457 patients (2.8%) had moderate NPDR and 672 (1.3%) had severe NPDR. Finally, 971 patients (1.8%) had proliferative DR requiring urgent referral to an ophthalmologist. The presence of any DR, non-referable DR or referable DR was strongly associated with increasing duration of diabetes and earlier age at diagnosis. CONCLUSIONS: The prevalence rate of DR in our study (16.3%) was slightly lower than other published international data. The RETINODIAB network proved to be an effective screening programme as it improved DR screening in Lisbon and Tagus Valley surrounding area
Resumo:
BACKGROUND AND STUDY AIMS: Various screening methods for colorectal cancer (CRC) are promoted by professional societies; however, few data are available about the factors that determine patient participation in screening, which is crucial to the success of population-based programs. This study aimed (i) to identify factors that determine acceptance of screening and preference of screening method, and (ii) to evaluate procedure success, detection of colorectal neoplasia, and patient satisfaction with screening colonoscopy. PATIENTS AND METHODS: Following a public awareness campaign, the population aged 50 - 80 years was offered CRC screening in the form of annual fecal occult blood tests, flexible sigmoidoscopy, a combination of both, or colonoscopy. RESULTS: 2731 asymptomatic persons (12.0 % of the target population) registered with and were eligible to take part in the screening program. Access to information and a positive attitude to screening were major determinants of participation. Colonoscopy was the method preferred by 74.8 % of participants. Advanced colorectal neoplasia was present in 8.5 %; its prevalence was higher in males and increased with age. Significant complications occurred in 0.5 % of those undergoing colonoscopy and were associated with polypectomy or sedation. Most patients were satisfied with colonoscopy and over 90 % would choose it again for CRC screening. CONCLUSIONS: In this population-based study, only a small proportion of the target population underwent CRC screening despite an extensive information campaign. Colonoscopy was the preferred method and was safe. The determinants of participation in screening and preference of screening method, together with the distribution of colorectal neoplasia in different demographic categories, provide a rationale for improving screening procedures.
Resumo:
Cette année, six études utiles pour la pratique ont été retenues. L'indication à la mammographie entre 40 et 49 ans devrait être évaluée individuellement et en tenant compte des risques/bénéfices de cet examen. Au-delà de 65 ans, un dépistage systématique de la fibrillation auriculaire avec prise de pouls puis ECG (si pouls irrégulier) pourrait être réalisé de manière systématique. Les risques de complications postcolonoscopie existent, particulièrement suite à des biopsies/polypectomies, et ce risque devrait être discuté. Les inhibiteurs de la pompe à protons au long court sont un facteur de risque de fracture de hanche. S'il est important de prendre en charge des pressions artérielles élevées au-delà de 80 ans, il faut être prudent (orthostatisme). Une corticothérapie précoce suite à une paralysie faciale périphérique est efficace. This year we have selected six studies useful for the day to day practice. A mammography in women 40 to 49 years of age should be evaluated taking into account the patient's profile and the possible risks and benefits of this exam. In patients over 65 years of age, a systematic atrial fibrillation screening, with pulse rate measuring then ECG (if irregular beat) should be realised on a regular basis. The risks for complications following colonoscopies do exist, especially after biopsies/polypectomies and this risk should be discussed. Long term proton pump inhibitor treatment is a risk factor for hip fracture. It is important to treat high blood pressure problems in the elderly, but the orthostatic risks should be adressed. A corticoid treatment started quickly for Bell's palsy is efficient
Resumo:
This article proposes an update on the recommendations for the check-up and the primary and secondary prevention of cancers and cardio-vascular diseases. Indeed, new clinical data led the adaptation and clarification of some of them. The novelties for cancer screening concern mainly colorectal, breast and prostate cancers. Screening for low ankle brachial index is not recommended.
Resumo:
OBJECTIVES: There is a continuing need to monitor and evaluate the impact of organized screening programmes on cancer incidence and mortality. We report results from a programme assessment conducted within the International Cancer Screening Network (ICSN) to understand the characteristics of cervical screening programmes within countries that have established population-based breast cancer screening programmes. METHODS: In 2007-2008, we asked 26 ICSN country representatives to complete a web-based survey that included questions on breast and cervical cancer screening programmes. We summarized information from 16 countries with both types of organized programmes. RESULTS: In 63% of these countries, the organization of the cervical cancer screening programme was similar to that of the breast cancer screening programme in the same country. There were differences in programme characteristics, including year established (1962-2003 cervical; 1986-2002 breast) and ages covered (15-70+ cervical; 40-75+ breast). Adoption of new screening technologies was evident (44% liquid-based Pap tests; 13% human papillomavirus (HPV)-triage tests cervical; 56% digital mammography breast). There was wide variation in participation rates for both programme types (<4-80% cervical; 12-88% breast), and participation rates tended to be higher for cervical (70-80%) than for breast (60-70%) cancer screening programmes. Eleven ICSN member countries had approved the HPV vaccine and five more were considering its use in their organized programmes. CONCLUSION: Overall, there were similarities and differences in the organization of breast and cervical cancer screening programmes among ICSN countries. This assessment can assist established and new screening programmes in understanding the organization and structure of cancer screening programmes.
Resumo:
[Table des matières] 1. Problemstellung. 1.1. Programme in anderen Ländern. 1.2. Situation in der Schweiz. 2. Methodisches Vorgehen. 2.1. Dokumentationsanalyse. 2.2. Experteninterviews. 3. Resultate : Beschreibung der wesentlichen Aktivitäten zur Programmentwicklung. 3.1. Wesentliche Aktivitäten in der Schweiz vor der Einführung des KVG. 3.2. Grundeinstellung zum organisierten Mammographie-Screening. 3.3. Gesetzliche Grundlagen. 3.4. Strukturen im schweizerischen Gesundheitswesen. 3.5. Finanzierung. 3.6. Rollen und Kompetenzen. 3.7. Wirksamkeit. 3.8. Internationale Expertise. 4. Lösungsansätze.
Resumo:
Erythrovirus B19 infection is usually benign but may have serious consequences in patients with hemolytic anemia (transient aplastic crisis), immunodeficiency (in whom persistent infection can lead to chronic bone marrow failure with anemia), or who are in the first or second trimester of gestation (spontaneous abortion, hydrops fetalis, and fetal death). Being non-enveloped, B19 resists most inactivation methods and can be transmitted by transfusion. B19 is difficult to cultivate and native virus is usually obtained from viremic blood. As specific antibodies may be absent, and there is no reliable immunological method for antigen detection, hybridization or polymerase chain reaction are needed for detecting viremia. A rapid method, gel hemagglutination (Diamed ID-Parvovirus B19 Antigen Test), can disclose highly viremic donations, whose elimination lessens the viral burden in pooled blood products and may even render them non-infectious. In order to obtain native antigen and to determine the frequency of viremic donors, we applied this test to blood donors in a period of high viral activity in our community. Positive or indeterminate results were re-tested by dot-blot hybridization. We tested 472 donors in 1998 and 831 ones in 1999. One viremic donor was found in 1999. We suggest that in periods of high community viral activity the gel hemagglutination test may be useful in avoiding highly viremic blood being added to plasma pools or directly transfused to patients under risk.