992 resultados para M-circuit System
Resumo:
The study aimed to compare the effects of intraosseous infusion of lactated Ringer's and 0.9% sodium chloride solutions on the electrolytes and acid-base balance in pigeons submitted to humerus osteosynthesis. Eighteen pigeons were undergoing to isoflurane anesthesia by an avalvular circuit system. They were randomly assigned into two groups (n=9) receiving lactated Ringer's solution (LR) or 0.9% sodium chloride (SC), in a continuous infusion rate of 20mL/kg/h, by using an intraosseous catheter into the tibiotarsus during 60-minute anesthetic procedure. Heart rate (HR), and respiratory rate (RR) were measured every 10 min. Venous blood samples were collected at 0, 30 and 60 minutes to analyze blood pH, PvCO2, HCO3 -, Na+ and K+. Blood gases and electrolytes showed respiratory acidosis in both groups during induction, under physical restraint. This acidosis was evidenced by a decrease of pH since 0 min, associated with a compensatory response, observed by increasing of HCO3 - concentration, at 30 and 60 min. It was not observed any changes on Na+ and K+ serum concentrations. According to the results, there is no reason for choosing one of the two solutions, and it could be concluded that both fluid therapy solutions do not promote any impact on acid-base balance and electrolyte concentrations in pigeons submitted to humerus osteosynthesis.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Seven captive male African wild dogs (Lycaon pictus) weighing 25-32 kg each, were anesthetized by i.m. injection via hand syringe with a combination of 1.5 mg/kg ketamine, 40 mu g/kg medetomidine, and 0.05 mg/kg atropine. Following endotracheal intubation, each animal was connected to a bain closed-circuit system that delivered 1.5% isoflurane and 2 L/min oxygen. Atipamezole (0.1 mg/kg i.v.; 0.1 mg/kg i.m.) was given at the end of each procedure (60 min following injection of medetomidine/ketamine/atropine). Time to sternal recumbency was 5-8 min. Times to standing after atipamezole administration were 8-20 min. This anesthetic regimen was repeated on three separate occasions (September 2000, February 2002, and October 2002) on all males to perform electroejaculation procedures. Each procedure was < 80 min from injection to standing. Dogs showed excellent muscle relaxation during the procedures. Arterial blood samples were collected at 10-min intervals for blood gases in one procedure (September 2000). Separate venous samples were taken from each dog during each procedure for hematology and biochemistry. These values were within the normal range for this species. Arterial hemoglobin oxygen saturation (SpO2) and heart rate (HR) were monitored continuously in addition to other anesthesia monitoring procedures (body temperature, respiratory rate [RR], capillary refill time, blink response, pupil position, deep pain perception reflex). All dogs maintained relatively stable SpO2 profiles during monitoring, with a mean (+/- SD) SpO2 of 92% +/- 5.4%. All other physiological variables (HR, RR, body temperature, blood pressure) were within normal limits. Following each procedure, normal behavior was noted in all dogs. All the dogs were reunited into the pack at completion of their anesthetic procedures. An injectable medetomidine-ketamine-atropine combination with maintenance by gaseous isoflurane and oxygen provides an inexpensive, reliable anesthetic for captive African wild dogs.
Resumo:
A class of algebras forms a variety if it is characterised by a collection of identities. There is a well-known method, often called the standard construction, which gives rise to algebras from m-cycle systems. It is known that the algebras arising from {1}-perfect m-cycle systems form a variety for m is an element of {3, 5} only, and that the algebras arising from {1, 2}-perfect m-cycle systems form a variety for m is an element of {3, 5, 7} only. Here we give, for any set K of positive integers, necessary and sufficient conditions under which the algebras arising from K-perfect m-cycle systems form a variety. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
In this contribution, a system identification procedure of a two-input Wiener model suitable for the analysis of the disturbance behavior of integrated nonlinear circuits is presented. The identified block model is comprised of two linear dynamic and one static nonlinear block, which are determined using an parameterized approach. In order to characterize the linear blocks, an correlation analysis using a white noise input in combination with a model reduction scheme is adopted. After having characterized the linear blocks, from the output spectrum under single tone excitation at each input a linear set of equations will be set up, whose solution gives the coefficients of the nonlinear block. By this data based black box approach, the distortion behavior of a nonlinear circuit under the influence of an interfering signal at an arbitrary input port can be determined. Such an interfering signal can be, for example, an electromagnetic interference signal which conductively couples into the port of consideration. © 2011 Author(s).
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The distribution of short-circuit current is investigated by means of two methods, one direct and the other analytic; both methods consider uniform probability distribution of line faults. In the direct method, the procedure consists of calculating fault currents at equidistant points along the line, starting from one of the end points and considering the other end open. The magnitude of the current is classified according to Brazilian standards (regulation NBR-7118). The analytic method assumes that the distribution of short-circuit currents through the busbar and the distribution of the line length connected to it are known, as well as the independence of values. The method is designed to determine the probability that fault currents through a line will surpass the pre-established magnitude, thus generating frequency distribution curves of short-circuit currents along the lines.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Vita.
Resumo:
Includes index.
Resumo:
Includes index.
Resumo:
Residual current-operated circuit-breakers (RCCBs) have proved useful devices for the protection of both human beings against ventricular fibrillation and installations against fire. Although they work well with sinusoidal waveforms, there is little published information on their characteristics. Due to shunt connected non-linear devices, not the least of which is the use of power electronic equipment, the supply is distorted. Consequently, RCCBs as well as other protection relays are subject to non-sinusoidal current waveforms. Recent studies showed that RCCBs are greatly affected by harmonics, however the reasons for this are not clear. A literature search has also shown that there are inconsistencies in the analysis of the effect of harmonics on protection relays. In this work, the way RCCBs operate is examined, then a model is built with the aim of assessing the effect of non-sinusoidal current on RCCBs. Tests are then carried out on a number of RCCBs and these, when compared with the results from the model showed good correlation. In addition, the model also enables us to explain the RCCBs characteristics for pure sinusoidal current. In the model developed, various parameters are evaluated but special attention is paid to the instantaneous value of the current and the tripping mechanism movement. A similar assessment method is then used to assess the effect of harmonics on two types of protection relay, the electromechanical instantaneous relay and time overcurrent relay. A model is built for each of them which is then simulated on the computer. Tests results compare well with the simulation results, and thus the model developed can be used to explain the relays behaviour in a harmonics environment. The author's models, analysis and tests show that RCCBs and protection relays are affected by harmonics in a way determined by the waveform and the relay constants. The method developed provides a useful tool and the basic methodology to analyse the behaviour of RCCBs and protection relays in a harmonics environment. These results have many implications, especially the way RCCBs and relays should be tested if harmonics are taken into account.