914 resultados para Liquid Bridge
Resumo:
The pulmonary crackling and the formation of liquid bridges are problems that for centuries have been attracting the attention of scientists. In order to study these phenomena, it was developed a canonical cubic lattice-gas like model to explain the rupture of liquid bridges in lung airways [A. Alencar et al., 2006, PRE]. Here, we further develop this model and add entropy analysis to study thermodynamic properties, such as free energy and force. The simulations were performed using the Monte Carlo method with Metropolis algorithm. The exchange between gas and liquid particles were performed randomly according to the Kawasaki dynamics and weighted by the Boltzmann factor. Each particle, which can be solid (s), liquid (l) or gas (g), has 26 neighbors: 6 + 12 + 8, with distances 1, √2 and √3, respectively. The energy of a lattice's site m is calculated by the following expression: Em = ∑k=126 Ji(m)j(k) in witch (i, j) = g, l or s. Specifically, it was studied the surface free energy of the liquid bridge, trapped between two planes, when its height is changed. For that, was considered two methods. First, just the internal energy was calculated. Then was considered the entropy. It was fond no difference in the surface free energy between this two methods. We calculate the liquid bridge force between the two planes using the numerical surface free energy. This force is strong for small height, and decreases as the distance between the two planes, height, is increased. The liquid-gas system was also characterized studying the variation of internal energy and heat capacity with the temperature. For that, was performed simulation with the same proportion of liquid and gas particle, but different lattice size. The scale of the liquid-gas system was also studied, for low temperature, using different values to the interaction Jij.
Resumo:
The experimental results obtained in experiment “STACO” made on board the Spacelab D-2 are re-visited, with image-analysis tools not then available. The configuration consisted of a liquid bridge between two solid supporting discs. An expected breakage occurred during the experiment. The recorded images are analysed and the measured behaviour compared with the results of a three dimensional model of the liquid dynamics, obtaining a much better fit than with linear models
Resumo:
The study of the stability of long liquid columns under microgravity was the purpose of one of the experiments carried out aboard Spacelab-Dl. In this paper a preliminary analysis of this experiment, mainly concerning the different liquid column breakages, is presented. As shown in the paper, the behaviour, both static and dynamic, of long liquid bridges can be accurately predicted by using available theoretical models.
Resumo:
The filling-withdrawal process of a long liquid bridge is analyzed using a one-dimensional linearized model for the dynamics of the liquid column. To carry out this study, a well-known standard operational method (Laplace transform) has been used, and time variation of both liquid velocity field and interface shape are obtained.
Resumo:
The lower stability limit for axisymmetric floating zones at rest between equal coaxial disks has been experimentally verified for several disk-separation/disk-diameter ratios by using the neutral buoyancy technique. Results show a close agre ment with theory in the case of bridge disruption and a wide scatter in the case of bridge etachment.
Resumo:
Besides space laboratories for in-orbit experimentation, Earth based facilities for laboratory experimentation are of paramount importance for the enhancement on liquid bridge knowledge. In spite of the constraints imposed by simulated microgravity (which force to work either with very small size liquid bridges or by using the Plateau tank technique, amongst other techniques), the availability and accessibility of Earth facilities can circumvent in many cases the drawbacks associated with simulated microgravity conditions. To support theoretical and in orbit experimental studies on liquid bridges under reduced gravity conditions, several ground facilities were developed at IDR. In the following these ground facilities are briefly described, and main results obtained by using them are cited.
Resumo:
The aim of our experiment on the Spacelab Dl Mission was to study the stability of long liquid columns under microgravity. Nominal configuration was a cylindrical liquid bridge anchored at the edges of two equal solid discs, 35 mm in diameter. Mechanical stimuli were applied through the discs and the liquid outer shape recorded for analysis. Nominal experiment procedures [1] were similar to those proposed for Spacelab-1 (1983), where by wetting problems allowed only partial success [2]. The same Fluid Physics Module, but with corrected end discs and a manually operated syringe for liquid injection, was used.
Resumo:
Conservation laws for an inviscid liquid bridge set into motion by conservative forces are given in integral form. These laws provide useful information on the overall motion of the bridge in the presence of unexpected or uncontrolled disturbances and could, in addition, be monitored in a computational solution of the problem as an accuracy check. Many of the resulting conservation laws are familiar to fluiddynamicists. Nevertheless, a systematic approach providing an exhaustive list of these laws reveals the existence of new conserved properties hardly deducible in the classical way. Although the present analysis concerns the case of axial, and constant, gravity it can be applied, with minor refinements, when the gravity field varies with time in both direction and intensity.
Resumo:
Liquids held by surface tension forces can bridge the gap between two solid bodies placed not too far apart from each other. The equilibrium conditions and stability criteria for static, cylindrical liquid bridges are well known. However, the behaviour of an unstable liquid bridge, regarding both its transition toward breaking and the resulting configuration, is a matter for discussion. The dynamical problem of axisymmetric rupture of a long liquid bridge anchored at two equal coaxial disks is treated in this paper through the adoption of one-dimensional theories which are widely used in capillary jet problems
Resumo:
The dynamics of inviscid, axisymmetric liquid bridges permits a simplified treatment if the bridge is long enough. Under such condition the evolution of the liquid zone is satisfactorily explained through a non-linear one-dimensional model. In the case of breaking, the one-dimensional model fails when the neck radius of the liquid column is close to zero; however, the model allows the calculation of the time variation of the liquid-bridge interface as well as of the fluid velocity field and, because the last part of the evolution is not needed, the overall results such as the breaking time and the volume of each of the two drops resulting after breakage can be calculated. In this paper numerical results concerning the behavior of clinical liquid bridges subjected to a small axial gravitational field are presented.
Resumo:
In this paper the dynamics of axisymmetric, slender, viscous liquid bridges having volume close to the cylindrical one, and subjected to a small gravitational field parallel to the axis of the liquid bridge, is considered within the context of one-dimensional theories. Although the dynamics of liquid bridges has been treated through a numerical analysis in the inviscid case, numerical methods become inappropriate to study configurations close to the static stability limit because the evolution time, and thence the computing time, increases excessively. To avoid this difficulty, the problem of the evolution of these liquid bridges has been attacked through a nonlinear analysis based on the singular perturbation method and, whenever possible, the results obtained are compared with the numerical ones.
Resumo:
n this paper the influence of an axial microgravity on the dynamic stability of axisymmetric slender liquid bridges between unequal disks is numerically studied by using a one-dimensional theory. The breaking of such liquid configurations is analyzed and the dependence of some overall characteristics of the breaking process on the value of axial microgravity, the geometry and the volume of the liquid bridge, as well as stability limits are obtained.
Resumo:
A feature of stability diagrams of liquid bridges between unequal disks subjected to small axial gravity forces is that, for each separation of disks, there is a value of microgravity for which an absolute minimum volume limit is reached. The dependence of such microgravity values on the liquid bridge geometry has been experimentally checked by using the neutral buoyancy technique, experimental results being in complete agreement with theoretical ones. Analytical background assuring the experimental procedure used is presented, and a second order analytical expression for the equilirium interface is also calculated.
Resumo:
A one-dimensional inviscid slice model has been used to study numerically the influence of axial microgravity on the breaking of liquid bridges having a volume close to that of gravitationless minimum volume stability limit. Equilibrium shapes and stability limits have been obtained as well as the dependence of the volume of the two drops formed after breaking on both the length and the volume of the liquid bridge. The breaking process has also been studied experimentally. Good agreement has been found between theory and experiment for neutrally buoyant systems
Resumo:
This paper deals with the dynamics of liquid bridges when subjected to an oscillatory microgravity field. The analysis has been performed by using a one-dimensional slice model, already used in liquid bridge problems, which allows to calculate not only the resonance frequencies of a wide range of such fluid configurations but also the dependence of the dynamic response of the liquid bridge on the frequency on the imposed perturbations. Theoretical results are compared with experimental ones obtained aboard Spacelab-Dl, the agreement between theoretical and experimental results being satisfactory