991 resultados para Length measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of root canal length is a significant outcome predictor for endodontic treatments. The aim of this prospective, controlled clinical study was to analyze endodontic working length measurements in preexisting cone-beam computed tomography (CBCT) scans and to compare them with clinical root canal length determination by using an electronic apex locator (EAL).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a configuration consisting of two fiberised Michelson interferometers and show that, with an optical balanced technique and suitable electronics, the signal corresponding to coherent interference in the first interferometer can be sufficiently attenuated in the channel processing the signal from the second interferometer. In this way it is possible to display simultaneous reflectograms of two different regions in the eye (e.g. cornea and retina) and infer the eye length from these measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a configuration consisting of two fiberised Michelson interferometers and show that, with an optical balanced technique and suitable electronics, the signal corresponding to coherent interference in the first interferometer can be sufficiently attenuated in the channel processing the signal from the second interferometer. In this way it is possible to display simultaneous reflectograms of two different regions in the eye (e.g. cornea and retina) and infer the eye length from these measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Includes bibliographical references.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To assess the degree of discomfort caused by length measurement in neonates, performed with one or both lower limbs extended, on the first and second day after birth, with either one or both lower limbs extended. METHODS: Healthy full-term neonates were systematically sampled during the months of February and March 2004. Crown-heel length was measured, using a 1-mm precision neonatometer, at approximately 8 h and 32 h after birth, with one and both lower limbs extended. The Neonatal Facial Coding System was used to assess discomfort during measurements. Data were analysed by parametric and non-parametric tests as appropriate. RESULTS: Whatever the measurement technique, discomfort scores are significantly higher during the length measurement than at baseline. Whenever length measurements are performed, discomfort scores are significantly higher when extending both lower limbs rather than one lower limb (p < 0.006). The measured length is greater with one lower limb extended; however, the difference decreases over time, being 0.19 cm (95% CI 0.1-0.3; p < 0.001) at approximately 32 h of age. No significant differences in length were found between measurements at approximately 8 or 32 h, regardless of the technique used. The best correlation between length measurements with one or both lower limbs extended was observed at approximately 32 h after birth (r = 0.98). CONCLUSION: Measuring crown-heel length is a distressful procedure for the neonate. Measurements with one lower limb extended result in less discomfort than when both lower limbs are extended, without decreasing the accuracy.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study was to verify the average fiber length and the juvenile and mature wood zones from Hevea brasiliensis proveniences from a reforestation area in São Paulo, Brazil. For this purpose, five Hevea brasiliensis trees were randomly collected from a 50-year-old plantation, located in Balsamo, São Paulo, Brazil. The trees were cut and five flat sawn boards were obtained. The juvenile and mature wood zones were determined by fiber length measurement from the pith to the bark. The results showed that: (a) the juvenile wood of this species occurred approx. between 40 and 55 mm, from the pith, and from this point forward, the mature wood zone was found; (b) there was a significant difference between the average fiber length of juvenile wood (1.26 mm) and mature wood (1.51 mm).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Telomere length measurement has been proposed as a promising tool to estimate the age of individuals in natural populations. We used real-time quantitative PCR (qPCR) to measure relative telomere length in four tissues (brain, kidney, liver and muscle) of European hake (Merluccius merluccius) in different groups based upon body length an otolith age estimate. We observed a high level of inter-individual differences in the measurements of relative telomere length in hakes of similar age and body length groups. The results of qPCR analysis showed a great variability in all measures and a lack of repeatability and reproducibility with significant statistical differences in the results of the different assays. The paper discusses the technical reasons for the variability in qPCR obtained in this work and by other authors.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Dyskeratosis congenita (DC) is an inherited bone marrow failure syndrome in which the known susceptibility genes (DKC1, TERC, and TERT) belong to the telomere maintenance pathway; patients with DC have very short telomeres. We used multicolor flow fluorescence in situ hybridization analysis of median telomere length in total blood leukocytes, granulocytes, lymphocytes, and several lymphocyte subsets to confirm the diagnosis of DC, distinguish patients with DC from unaffected family members, identify clinically silent DC carriers, and discriminate between patients with DC and those with other bone marrow failure disorders. We defined "very short" telomeres as below the first percentile measured among 400 healthy control subjects over the entire age range. Diagnostic sensitivity and specificity of very short telomeres for DC were more than 90% for total lymphocytes, CD45RA+/CD20- naive T cells, and CD20+ B cells. Granulocyte and total leukocyte assays were not specific; CD45RA- memory T cells and CD57+ NK/NKT were not sensitive. We observed very short telomeres in a clinically normal family member who subsequently developed DC. We propose adding leukocyte subset flow fluorescence in situ hybridization telomere length measurement to the evaluation of patients and families suspected to have DC, because the correct diagnosis will substantially affect patient management.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interlaminar fracture toughness in pure mode II (GIIc) of a Carbon-Fibre Reinforced Plastic (CFRP) composite is characterized experimentally and numerically in this work, using the End-Notched Flexure (ENF) fracture characterization test. The value of GIIc was extracted by a new data reduction scheme avoiding the crack length measurement, named Compliance-Based Beam Method (CBBM). This method eliminates the crack measurement errors, which can be non-negligible, and reflect on the accuracy of the fracture energy calculations. Moreover, it accounts for the Fracture Process Zone (FPZ) effects. A numerical study using the Finite Element Method (FEM) and a triangular cohesive damage model, implemented within interface finite elements and based on the indirect use of Fracture Mechanics, was performed to evaluate the suitability of the CBBM to obtain GIIc. This was performed comparing the input values of GIIc in the numerical models with the ones resulting from the application of the CBBM to the numerical load-displacement (P-) curve. In this numerical study, the Compliance Calibration Method (CCM) was also used to extract GIIc, for comparison purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ao longo destes últimos anos as ligações adesivas têm vindo a verificar um aumento progressivo em aplicações estruturais em detrimento das ligações mecânicas convencionais. Esta alteração de paradigma deve-se às vantagens que as juntas adesivas possuem relativamente aos outros métodos de ligação. A mecânica da fratura e os Modelos de Dano Coesivo (MDC) são critérios comuns para prever a resistência em juntas adesivas e usam como parâmetros fundamentais as taxas de libertação de energia. Pelo facto do ensaio 4-Point End Notched Flexure (4-ENF), aplicado em juntas adesivas, ainda estar pouco estudado é de grande relevância um estudo acerca da sua viabilidade para a determinação da taxa crítica de libertação de energia de deformação ao corte (GIIc). Esta dissertação tem como objetivo principal efetuar uma comparação entre os métodos End- Notched Flexure (ENF) e 4-ENF na determinação de GIIc em juntas adesivas. Para tal foram utilizados 3 adesivos: Araldite® AV138, Araldite® 2015 e SikaForce® 7752. O trabalho experimental passou pela conceção e fabrico de uma ferramenta para realização do ensaio 4-ENF, seguindo-se o fabrico e a preparação dos provetes para os ensaios. Pelo facto do ensaio 4-ENF ainda se encontrar pouco divulgado em juntas adesivas, e não se encontrar normalizado, uma parte importante do trabalho passou pela pesquisa e análise em trabalhos de investigação e artigos científicos. A análise dos resultados foi realizada por comparação direta dos valores de GIIc com os resultados obtidos no ensaio ENF, sendo realizada por série de adesivo, através da comparação das curvas P-δ e curvas-R. Como resultado verificou-se que o ensaio 4-ENF em ligações adesivas não é o mais versátil para a determinação do valor de GIIc, e que apenas um método de obtenção de GIIc é viável. Este método é baseado na medição do comprimento de fenda (a). Ficou evidenciado que o ensaio ENF, devido a ser um ensaio normalizado, por apresentar um setup mais simples e por apresentar uma maior disponibilidade de métodos para a determinação do valor de GIIc, é o mais recomendado. Conclui-se assim que o ensaio 4-ENF, embora sendo uma alternativa ao ensaio ENF, tem aplicação mais limitada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Peircean semiotic analysis is employed to examine the construction/representation of signs-thinking of 32 early elementary school students regarding the concept of length measurement. The work consisted of developing concepts of standard unit, reading and interpretation of measurement by instruments, so that the mathematical language presented in the concrete materials was being signified and re-signified as a tool for perception and representation of new concepts. The pedagogical triad Feeling-Perceiving, Relating-Concept (F-P/R/C) co-related with the dynamism of the semiosis process, defined by Charles Sanders Peirce (1839-1914) in his semiotic theory on the production of the sign (Object, Representamen and Interpretant), enabled the interpretation and analysis of the students' inferences in the phase of perception (feel, admire), induction (experience), and deduction (concept).