994 resultados para Lead-acid
Resumo:
Electrical energy storage is a really important issue nowadays. As electricity is not easy to be directly stored, it can be stored in other forms and converted back to electricity when needed. As a consequence, storage technologies for electricity can be classified by the form of storage, and in particular we focus on electrochemical energy storage systems, better known as electrochemical batteries. Largely the more widespread batteries are the Lead-Acid ones, in the two main types known as flooded and valve-regulated. Batteries need to be present in many important applications such as in renewable energy systems and in motor vehicles. Consequently, in order to simulate these complex electrical systems, reliable battery models are needed. Although there exist some models developed by experts of chemistry, they are too complex and not expressed in terms of electrical networks. Thus, they are not convenient for a practical use by electrical engineers, who need to interface these models with other electrical systems models, usually described by means of electrical circuits. There are many techniques available in literature by which a battery can be modeled. Starting from the Thevenin based electrical model, it can be adapted to be more reliable for Lead-Acid battery type, with the addition of a parasitic reaction branch and a parallel network. The third-order formulation of this model can be chosen, being a trustworthy general-purpose model, characterized by a good ratio between accuracy and complexity. Considering the equivalent circuit network, all the useful equations describing the battery model are discussed, and then implemented one by one in Matlab/Simulink. The model has been finally validated, and then used to simulate the battery behaviour in different typical conditions.
Resumo:
"This manual supersedes TM 9-6140-200-14, 20 August 1971."
Resumo:
"July 1989."
Resumo:
Dissertation presented to confer Master Degree in Chemical and Biochemical Engineering
Resumo:
Based on the report for the unit “Project IV” of the PhD programme on Technology Assessment under the supervision of Dr.-Ing. Marcel Weil and Prof. Dr. António Brandão Moniz. The report was presented and discussed at the Doctorate Conference on Technologogy Assessment in July 2013 at the University Nova Lisboa, Caparica campus.
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores
Resumo:
Conventional stationary lead acid batteries positive tubular plates have a specific capacity of about 120 Ah/kg. This value represents an active material utilization coefficient of 50%. The production of these plates includes some initial processes to generate the active PbO2 from a precursor material. In the present work it will be presented a proper and novel methodology to assemble tubular plates directely with nanometric powder of PbO2 particles. The utilization coefficient of these plates was about 80%, and they were able to endure more than 130 severe duty cycles. This high utilization coefficient is a higly desirable feature for electric vehicles batteries.
Resumo:
Nykyään monet käyttökohteet vaativat akuilta aiempaa parempaa suorituskykyä, joten on syntynyt kasvavaa tarvetta uusien akkujen kehittämiselle erilaisista uusista materiaaleista ja uusiin valmistusmenetelmiin pohjautuen. Työn tavoitteena on selvittää kirjallisuustutkimuksena litium-vanadiini-fosfaattiakun ja vanadiini-redoksi-virtausakun ominaisuuksia, saatavuutta, sovelluskohteita ja vertailla niitä muutamaan eri litiumakkutekniikkaan. Tutkimuksen perusteella litium-vanadiini-fosfaattiakkuja ei ole vielä saatavilla kaupallisesti, joten työssä tutkittiin niitä teknisten raporttien pohjalta. Raporttien pohjalta arvioituna, parhaita ominaisuuksia litium-vanadiini-fosfaattiakuilla on erinomainen kuormituksen kesto ja korkea nimellisjännite. Sähköisissä ajoneuvoissa litium-vanadiini-fosfaattiakuilla on suurimmat mahdollisuudet erilaisissa hybridiajoneuvoissa, mutta todennäköisesti ne soveltuvat täyssähköisiin ajoneuvoihin vähintään yhtä hyvin kuin esimerkiksi litium-rauta-fosfaattiakut, jos valmistuskustannukset olisivat samalla tasolla. Vanadiini-redoksi-virtausakkua on jo markkinoilla usean valmistajan toimesta. Niiden ominaisuudet poikkeavat paljon muista akkutyypeistä ja erikoisuutena on mahdollisuus akun pikalataukseen elektrolyyttinesteet vaihtamalla. Syklien kestossa päästään myös erinomaisiin arvoihin, mutta suurimmat ongelmat ovat lyijyakkuakin matalampi energiatiheys ja tehotiheys. Vanadiini-redoksi-virtausakut soveltuvat parhaiten suuren kokoluokan sähköverkkoratkaisuihin ja sähköisissä ajoneuvoissa niiden mahdollisuudet rajoittunevat täyssähköisiin linja-autoihin ja isoihin työkoneisiin.
Resumo:
Recent developments in power electronics technology have made it possible to develop competitive and reliable low-voltage DC (LVDC) distribution networks. Further, islanded microgrids—isolated small-scale localized distribution networks— have been proposed to reliably supply power using distributed generations. However, islanded operations face many issues such as power quality, voltage regulation, network stability, and protection. In this thesis, an energy management system (EMS) that ensures efficient energy and power balancing and voltage regulation has been proposed for an LVDC island network utilizing solar panels for electricity production and lead-acid batteries for energy storage. The EMS uses the master/slave method with robust communication infrastructure to control the production, storage, and loads. The logical basis for the EMS operations has been established by proposing functionalities of the network components as well as by defining appropriate operation modes that encompass all situations. During loss-of-powersupply periods, load prioritizations and disconnections are employed to maintain the power supply to at least some loads. The proposed EMS ensures optimal energy balance in the network. A sizing method based on discrete-event simulations has also been proposed to obtain reliable capacities of the photovoltaic array and battery. In addition, an algorithm to determine the number of hours of electric power supply that can be guaranteed to the customers at any given location has been developed. The successful performances of all the proposed algorithms have been demonstrated by simulations.
Resumo:
Die wachsende Weltbevölkerung bedingt einen höheren Energiebedarf, dies jedoch unter der Beachtung der nachhaltigen Entwicklung. Die derzeitige zentrale Versorgung mit elektrischer Energie wird durch wenige Erzeugungsanlagen auf der Basis von fossilen Primärenergieträgern und Kernenergie bestimmt, die die räumlich verteilten Verbraucher zuverlässig und wirtschaftlich über ein strukturiertes Versorgungssystem beliefert. In den Elektrizitätsversorgungsnetzen sind keine nennenswerten Speicherkapazitäten vorhanden, deshalb muss die von den Verbrauchern angeforderte Energie resp. Leistung jederzeit von den Kraftwerken gedeckt werden. Bedingt durch die Liberalisierung der Energiemärkte und die geforderte Verringerung der Energieabhängigkeit Luxemburgs, unterliegt die Versorgung einem Wandel hin zu mehr Energieeffizienz und erhöhter Nutzung der dargebotsabhängigen Energiequellen. Die Speicherung der aus der Windkraft erzeugten elektrischen Energie, wird in den Hochleistungs-Bleiakkumulatoren, errichtet im ländlichen Raum in der Nähe der Windkraftwerke, eingespeichert. Die zeitversetzte Einspeisung dieser gespeicherten elektrischen Energie in Form von veredelter elektrischer Leistung während den Lastspitzen in das 20 kV-Versorgungsnetz der CEGEDEL stellt die Innovation in der luxemburgischen Elektrizitätsversorgung dar. Die Betrachtungen beschränken sich somit auf die regionale, relativ kleinräumige Einbindung der Windkraft in die elektrische Energieversorgung des Großherzogtums Luxemburg. Die Integration der Windkraft im Regionalbereich wird in den Vordergrund der Untersuchung gerückt. Überregionale Ausgleichseffekte durch Hochspannungsleitungen der 230/400 kV-Systeme werden außer Acht gelassen. Durch die verbrauchernahe Bereitstellung von elektrischer Spitzenleistung vermindern sich ebenfalls die Übertragungskosten aus den entfernten Spitzenlastkraftwerken, der Ausbau von Kraftwerkskapazitäten kann in die Zukunft verschoben werden. Die Emission von Treibhausgasen in thermischen Kraftwerken wird zum Teil reduziert. Die Berechnungen der Wirtschaftlichkeit von Hybridanlagen, zusammengesetzt aus den Windkraftwerken und den Hochleistungs-Bleiakkumulatoren bringen weitere Informationen zum Einsatz dieser dezentralen Speichern, als Partner der nachhaltigen Energieversorgung im ländlichen Raum. Die untersuchte Einspeisung von erneuerbarer Spitzenleistung lässt sich auch in die Entwicklungsländer übertragen, welche nicht über zentrale Kraftwerkskapazitäten und Verteilungsnetze verfügen.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)