945 resultados para Lasers - Diagnostic use


Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is shown for the first time that uncooled tunable DBR-laser diodes can be used as athermal WDM sources. Using novel bias current control, absolute wavelength control to within 6Å has been achieved for temperatures up to 70°C. © 2000 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the framework of the ITER Control Breakdown Structure (CBS), Plant System Instrumentation & Control (I&C) defines the hardware and software required to control one or more plant systems [1]. For diagnostics, most of the complex Plant System I&C are to be delivered by ITER Domestic Agencies (DAs). As an example for the DAs, ITER Organization (IO) has developed several use cases for diagnostics Plant System I&C that fully comply with guidelines presented in the Plant Control Design Handbook (PCDH) [2]. One such use case is for neutron diagnostics, specifically the Fission Chamber (FC), which is responsible for delivering time-resolved measurements of neutron source strength and fusion power to aid in assessing the functional performance of ITER [3]. ITER will deploy four Fission Chamber units, each consisting of three individual FC detectors. Two of these detectors contain Uranium 235 for Neutron detection, while a third "dummy" detector will provide gamma and noise detection. The neutron flux from each MFC is measured by the three methods: . Counting Mode: measures the number of individual pulses and their location in the record. Pulse parameters (threshold and width) are user configurable. . Campbelling Mode (Mean Square Voltage): measures the RMS deviation in signal amplitude from its average value. .Current Mode: integrates the signal amplitude over the measurement period

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmentally stable high-power erbium fiber soliton lasers are constructed by Kerr or carrier-type mode locking. We obtain high-energy pulses by using relatively short fiber lengths and providing large amounts of negative dispersion with chirped fiber Bragg gratings. The pulse energies and widths generated with both types of soliton laser are found to scale with the square root of the cavity dispersion. Kerr mode locking requires pulses with an approximately three times higher nonlinear phase shift in the cavity than carrier mode locking, which leads to the generation of slightly shorter pulses with as much as seven times higher pulse energies at the mode-locking threshold.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmentally stable high-power erbium fiber soliton lasers are constructed by Kerr or carrier-type mode locking. We obtain high-energy pulses by using relatively short fiber lengths and providing large amounts of negative dispersion with chirped fiber Bragg gratings. The pulse energies and widths generated with both types of soliton laser are found to scale with the square root of the cavity dispersion. Kerr mode locking requires pulses with an approximately three times higher nonlinear phase shift in the cavity than carrier mode locking, which leads to the generation of slightly shorter pulses with as much as seven times higher pulse energies at the mode-locking threshold.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To describe retinal nerve fiber layer changes in late-stage diffuse unilateral subacute neuroretinitis eyes and compare these results with healthy eyes observed through nerve fiber analyzer (GDx®). Methods: This is a retrospective case-control study in which 49 eyes in late-stage diffuse unilateral subacute neuroretinitis were examined from May/97 to December/ 01. First, eyes with diffuse unilateral subacute neuroretinitis and healthy contralateral eyes (Control Group I) were statistically matched. Subsequently, eyes with diffuse unilateral subacute neuroretinitis were compared with eyes of healthy patients (Control Group II). Results: Eyes from Control Groups I and II had higher relative frequency of “within normal limits” status. Eyes from the diffuse unilateral subacute neuroretinitis (DUSN) Group had higher frequency of “outside normal limits” and “borderline” status. Control Groups I and II had absolute values different from the DUSN Group regarding all parameters (p<0.05), except for Symmetry in Control Groups I and II, Average thickness and Superior Integral in control group II. Conclusion: Patients with late-stage diffuse unilateral subacute neuroretinitis presented presumed decrease in nerve fiber layer thickness shown by GDx®. Retinal zones with larger vascular support and larger amount of nerve fibers presented higher decrease in the delay of the reflected light measured by the nerve fiber analyzer

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To describe retinal nerve fiber layer changes in late-stage diffuse unilateral subacute neuroretinitis eyes and compare these results with healthy eyes observed through nerve fiber analyzer (GDx®). Methods: This is a retrospective case-control study in which 49 eyes in late-stage diffuse unilateral subacute neuroretinitis were examined from May/97 to December/ 01. First, eyes with diffuse unilateral subacute neuroretinitis and healthy contralateral eyes (Control Group I) were statistically matched. Subsequently, eyes with diffuse unilateral subacute neuroretinitis were compared with eyes of healthy patients (Control Group II). Results: Eyes from Control Groups I and II had higher relative frequency of “within normal limits” status. Eyes from the diffuse unilateral subacute neuroretinitis (DUSN) Group had higher frequency of “outside normal limits” and “borderline” status. Control Groups I and II had absolute values different from the DUSN Group regarding all parameters (p<0.05), except for Symmetry in Control Groups I and II, Average thickness and Superior Integral in control group II. Conclusion: Patients with late-stage diffuse unilateral subacute neuroretinitis presented presumed decrease in nerve fiber layer thickness shown by GDx®. Retinal zones with larger vascular support and larger amount of nerve fibers presented higher decrease in the delay of the reflected light measured by the nerve fiber analyzer

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To describe retinal nerve fiber layer changes in late-stage diffuse unilateral subacute neuroretinitis eyes and compare these results with healthy eyes observed through nerve fiber analyzer (GDx®). Methods: This is a retrospective case-control study in which 49 eyes in late-stage diffuse unilateral subacute neuroretinitis were examined from May/97 to December/ 01. First, eyes with diffuse unilateral subacute neuroretinitis and healthy contralateral eyes (Control Group I) were statistically matched. Subsequently, eyes with diffuse unilateral subacute neuroretinitis were compared with eyes of healthy patients (Control Group II). Results: Eyes from Control Groups I and II had higher relative frequency of “within normal limits” status. Eyes from the diffuse unilateral subacute neuroretinitis (DUSN) Group had higher frequency of “outside normal limits” and “borderline” status. Control Groups I and II had absolute values different from the DUSN Group regarding all parameters (p<0.05), except for Symmetry in Control Groups I and II, Average thickness and Superior Integral in control group II. Conclusion: Patients with late-stage diffuse unilateral subacute neuroretinitis presented presumed decrease in nerve fiber layer thickness shown by GDx®. Retinal zones with larger vascular support and larger amount of nerve fibers presented higher decrease in the delay of the reflected light measured by the nerve fiber analyzer

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drawing on upper echelon theory and focusing on the context of higher education reforms in Australia within new public management in university faculties/colleges, this study investigates the diagnostic versus interactive uses of management control systems by Deans/Pro-Vice Chancellors of Faculties/Colleges (hereafter called Faculty PVCs). It seeks to identify how the professional and experiential characteristics of these senior academic executives and the structure of their Faculty, impact on their managerial and collegial orientation as reflected in their approach to using management controls. A mail survey of Faculty PVCs is conducted amongst a census of all Faculties/Colleges of all universities in Australia. Supplementing this survey are semi-structured interviews with the PVC of the business and science Faculty at a large Australian university. Results reveal that PVCs who have had a longer career in higher education tend to use MCSs more interactively (or collegially). There is also evidence that as PVCs hold their current position for longer periods, they tend to move from an early diagnostic use of MCSs to a subsequent interactive use. Further, the higher the complexity of a Faculty the more a PVC will adopt an interactive approach to MCS use. Other PVC and Faculty characteristics did not reveal patterns of significant influence on the interactive or diagnostic use of MCSs. A key revelation from interviews is that PVCs will give over-riding importance to meeting centrally-set diagnostically-focused KPI, but still take a collegial approach within their Faculty to the broader use of MCSs. The findings lend limited support to upper echelons theory, but provide a grounding for further research into the impact that a managerial versus a collegial approach by PVCs/Deans may have on their Faculty’s growth in innovative capacities, teaching qualities or financial strength.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Next Generation Sequencing (NGS) has the potential of becoming an important tool in clinical diagnosis and therapeutic decision-making in oncology owing to its enhanced sensitivity in DNA mutation detection, fast-turnaround of samples in comparison to current gold standard methods and the potential to sequence a large number of cancer-driving genes at the one time. We aim to test the diagnostic accuracy of current NGS technology in the analysis of mutations that represent current standard-of-care, and its reliability to generate concomitant information on other key genes in human oncogenesis. Thirteen clinical samples (8 lung adenocarcinomas, 3 colon carcinomas and 2 malignant melanomas) already genotyped for EGFR, KRAS and BRAF mutations by current standard-of-care methods (Sanger Sequencing and q-PCR), were analysed for detection of mutations in the same three genes using two NGS platforms and an additional 43 genes with one of these platforms. The results were analysed using closed platform-specific proprietary bioinformatics software as well as open third party applications. Our results indicate that the existing format of the NGS technology performed well in detecting the clinically relevant mutations stated above but may not be reliable for a broader unsupervised analysis of the wider genome in its current design. Our study represents a diagnostically lead validation of the major strengths and weaknesses of this technology before consideration for diagnostic use.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: Recent observational studies indicate that post-diagnostic use of aspirin in breast cancer patients may protect against cancer progression perhaps by inhibiting cyclooxygenase-2 dependent mechanisms. Evidence also supports a crucial role for interactions between tumour cells and circulating platelets in cancer growth and dissemination, therefore, use of low-dose aspirin may reduce the risk of death from cancer in breast cancer patients.

METHODS: A cohort of newly diagnosed breast cancer patients (1998 to 2006) were identified in the UK Clinical Practice Research Datalink (and confirmed by cancer registry linkage). Cancer-specific deaths were identified up to 2011 from Office for National Statistics mortality data. A nested case-control analysis was conducted using conditional logistic regression to compare post-diagnostic aspirin exposure using General Practice prescription data in 1,435 cases (breast cancer deaths) with 5,697 controls (matched by age and year of diagnosis).

RESULTS: After breast cancer diagnosis, 18.3% of cancer-specific deaths and 18.5% of matched controls received at least one prescription for low-dose aspirin, corresponding to an odds ratio (OR) of 0.98 (95% CI 0.83, 1.15). Adjustment for potential confounders (including stage and grade) had little impact on this estimate. No dose response relationship was observed when the number of tablets was investigated and no associations were seen when analyses were stratified by receipt of prescriptions for aspirin in the pre-diagnostic period, by stage at diagnosis or by receipt of prescriptions for hormone therapy.

CONCLUSIONS: Overall, in this large population-based cohort of breast cancer patients, there was little evidence of an association between receipt of post-diagnostic prescriptions for low-dose aspirin and breast cancer-specific death. However, information was not available on medication compliance or over-the-counter use of aspirin, which may have contributed to the null findings.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fifty-three patients with histologically proven carcinoma were injected with highly purified [131I]-labeled goat antibodies or fragments of antibodies against carcinoembryonic antigen (CEA). Each patient was tested by external photoscanning 4, 24, 36 and 48 h after injection. In 22 patients (16 of 38 injected with intact antibodies, 5 of 13 with F(ab')2 fragments and 1 of 2 with Fab' fragments), an increased concentration of 131I radioactivity corresponding to the previously known tumor location was detected by photoscanning 36-48 h after injection. Blood pool and secreted radioactivity was determined in all patients by injecting 15 min before scanning, [99mTc]-labeled normal serum albumin and free 99mTc04-. The computerized subtraction of 99mTc from 131I radioactivity enhanced the definition of tumor localization in the 22 positive patients. However, in spite of the computerized subtraction, interpretation of the scans remained doubtful for 12 patients and was entirely negative for 19 additional patients. In order to provide a more objective evaluation for the specificity of the tumor localization of antibodies, 14 patients scheduled for tumor resection were injected simultaneously with [131I]-labeled antibodies or fragments and with [125I]-labeled normal goat IgG or fragments. After surgery, the radioactivity of the two isotopes present either in tumor or adjacent normal tissues was measured in a dual channel scintillation counter. The results showed that the antibodies or their fragments were 2-4 times more concentrated in the tumor than in the normal tissues. In addition, it was shown that the injected antibodies formed immune complexes with circulating CEA and that the amount of immune complexes detectable in serum was roughly proportional to the level of circulating CEA.