998 resultados para Laser safety
Resumo:
Vintage video (1986) on laser safety, presented by Dr. Gillian Rice. This is a 37 minute video, explaining the hazards which are likely to be encountered and ways to reduce those hazards in teaching and research laboratories in higher education. Presented in 5 parts: Part 1 (1:49) Laser radiation and the body Part 2 (8:49) Classes of laser Part 3 (13:32) Safety measures Part 4 (21:32) Other risks: precautions Part 5 (31:49) Summary
Resumo:
Laser safety door signs for 3R, 3B and class 4 laser areas
Resumo:
Documents, Guidance, Video information relating to Laser Safety in the University
Resumo:
Blank laser user registration form
Resumo:
JUSTIFICATIVA E OBJETIVOS: As cirurgias com a utilização do laser apresentam riscos para o paciente e para a equipe médica. O objetivo deste artigo é apresentar noções básicas sobre o laser e regras para aumentar a segurança dos procedimentos com sua utilização. CONTEÚDO: O presente artigo contém noções de física aplicadas ao laser, regras de segurança e a conduta em caso de ocorrência de eventos adversos com a utilização do laser. CONCLUSÕES: Concluímos que, quando manipulado por profissionais treinados, e respeitadas as normas de segurança, o laser é útil e seguro, tanto para o paciente quanto para a equipe médica.
Resumo:
To establish safety parameters, we in vitro studied the increase in intrapulpal temperature caused by the use of a cw CO2 laser. A thermistor was implanted in the inner part of the pulpal chamber of 25 human lower third molars to measure the intrapulpal temperature produced by laser powers between 2-10 W and exposure times of 0.5-25.0 s. The Pearson linear correlation factor applied to the measured values showed there is a direct relationship between the independent variable and the applied power. A variance analysis produced the linear regression equation: T=1.10+(0.127)E where T is the temperature and E the energy. The results showed that, with a power of 4 W and maximum exposure time of 2.5 s (10 J) and a power density of 12738.85 W cm-2, there will be no damaging reactions affecting the pulpal tissues.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
This short video is designed to make you think about the safety aspects of working with lasers within laser laboratories. Postgraduates and research fellows work with many different types of lasers in a variety of different experimental conditions. These lasers are often more powerful than those used as an undergraduate and require additional safety practices. The video was demonstrated to the EUNIS 2008 conference Aarhus, Denmark, and was a finalist in the Dorup E-Learning Award.
Resumo:
Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (−52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments.
Resumo:
This report addresses the assessment of variation in elastic property of soft biological tissues non-invasively using laser speckle contrast measurement. The experimental as well as the numerical (Monte-Carlo simulation) studies are carried out. In this an intense acoustic burst of ultrasound (an acoustic pulse with high power within standard safety limits), instead of continuous wave, is employed to induce large modulation of the tissue materials in the ultrasound insonified region of interest (ROI) and it results to enhance the strength of the ultrasound modulated optical signal in ultrasound modulated optical tomography (UMOT) system. The intensity fluctuation of speckle patterns formed by interference of light scattered (while traversing through tissue medium) is characterized by the motion of scattering sites. The displacement of scattering particles is inversely related to the elastic property of the tissue. We study the feasibility of laser speckle contrast analysis (LSCA) technique to reconstruct a map of the elastic property of a soft tissue-mimicking phantom. We employ source synchronized parallel speckle detection scheme to (experimentally) measure the speckle contrast from the light traversing through ultrasound (US) insonified tissue-mimicking phantom. The measured relative image contrast (the ratio of the difference of the maximum and the minimum values to the maximum value) for intense acoustic burst is 86.44 % in comparison to 67.28 % for continuous wave excitation of ultrasound. We also present 1-D and 2-D image of speckle contrast which is the representative of elastic property distribution.
Resumo:
The characteristic of several night imaging and display technologies on cars are introduced. Compared with the current night vision technologies on cars, Range-gated technology can eliminate backscattered light and increase the SNR of system. The theory of range-gated image technology is described. The plan of range-gated system on cars is designed; the divergence angle of laser can be designed to change automatically, this allows overfilling of the camera field of view to effectively attenuate the laser when necessary. Safety range of the driver is calculated according to the theory analysis. Observation distance of the designed system is about 500m which is satisfied with the need of safety driver range.
Resumo:
Shape memory NiTi alloys have been used extensively for medical device applications such as orthopedic, dental, vascular and cardiovascular devices on account of their unique shape memory effect (SME) and super-elasticity (SE). Laser welding is found to be the most suitable method used to fabricate NiTi-based medical components. However, the performance of laser-welded NiTi alloys under corrosive environments is not fully understood and a specific focus on understanding the corrosion fatigue behaviour is not evident in the literature. This study reveals a comparison of corrosion fatigue behaviour of laser-welded and bare NiTi alloys using bending rotation fatigue (BRF) test which was integrated with a specifically designed corrosion cell. The testing environment was Hanks’ solution (simulated body fluid) at 37.5oC. Electrochemical impedance spectroscopic (EIS) measurement was carried out to monitor the change of corrosion resistance at different periods during the BRF test. Experiments indicate that the laser-welded NiTi alloy would be more susceptible to the corrosion fatigue attack than the bare NiTi alloy. This finding can serve as a benchmark for the product designers and engineers to determine the factor of safety of NiTi medical devices fabricated using laser welding.
Resumo:
Corrosion fatigue is a fracture process as a consequence of synergistic interactions between the material structure, corrosive environment and cyclic loads/strains. It is difficult to be detected and can cause unexpected failure of engineering components in use. This study reveals a comparison of corrosion fatigue behaviour of laser-welded and bare NiTi wires using bending rotation fatigue (BRF) test coupled with a specifically-designed corrosion cell. The testing medium was Hanks’ solution (simulated body fluid) at 37.5 oC. Electrochemical impedance spectroscopic (EIS) measurement was carried out to monitor the change of corrosion resistance of sample during the BRF test at different periods of time. Experiments indicate that the laser-welded NiTi wire would be more susceptible to the corrosion fatigue attack than the bare NiTi wire. This study can serve as a benchmark for the product designers and engineers to understand the corrosion fatigue behaviour of the NiTi laser weld joint and determine the fatigue life safety factor for NiTi medical devices/implants involving laser welding in the fabrication process.