923 resultados para Large Size
Resumo:
Recent efforts in the characterization of air-water flows properties have included some clustering process analysis. A cluster of bubbles is defined as a group of two or more bubbles, with a distinct separation from other bubbles before and after the cluster. The present paper compares the results of clustering processes two hydraulic structures. That is, a large-size dropshaft and a hydraulic jump in a rectangular horizontal channel. The comparison highlighted some significant differences in clustering production and structures. Both dropshaft and hydraulic jump flows are complex turbulent shear flows, and some clustering index may provide some measure of the bubble-turbulence interactions and associated energy dissipation.
Resumo:
The knowledge of the slug flow characteristics is very important when designing pipelines and process equipment. When the intermittences typical in slug flow occurs, the fluctuations of the flow variables bring additional concern to the designer. Focusing on this subject the present work discloses the experimental data on slug flow characteristics occurring in a large-size, large-scale facility. The results were compared with data provided by mechanistic slug flow models in order to verify their reliability when modelling actual flow conditions. Experiments were done with natural gas and oil or water as the liquid phase. To compute the frequency and velocity of the slug cell and to calculate the length of the elongated bubble and liquid slug one used two pressure transducers measuring the pressure drop across the pipe diameter at different axial locations. A third pressure transducer measured the pressure drop between two axial location 200 m apart. The experimental data were compared with results of Camargo's1 algorithm (1991, 1993), which uses the basics of Dukler & Hubbard's (1975) slug flow model, and those calculated by the transient two-phase flow simulator OLGA.
Resumo:
The rapid growth in high data rate communication systems has introduced new high spectral efficient modulation techniques and standards such as LTE-A (long term evolution-advanced) for 4G (4th generation) systems. These techniques have provided a broader bandwidth but introduced high peak-to-average power ratio (PAR) problem at the high power amplifier (HPA) level of the communication system base transceiver station (BTS). To avoid spectral spreading due to high PAR, stringent requirement on linearity is needed which brings the HPA to operate at large back-off power at the expense of power efficiency. Consequently, high power devices are fundamental in HPAs for high linearity and efficiency. Recent development in wide bandgap power devices, in particular AlGaN/GaN HEMT, has offered higher power level with superior linearity-efficiency trade-off in microwaves communication. For cost-effective HPA design to production cycle, rigorous computer aided design (CAD) AlGaN/GaN HEMT models are essential to reflect real response with increasing power level and channel temperature. Therefore, large-size AlGaN/GaN HEMT large-signal electrothermal modeling procedure is proposed. The HEMT structure analysis, characterization, data processing, model extraction and model implementation phases have been covered in this thesis including trapping and self-heating dispersion accounting for nonlinear drain current collapse. The small-signal model is extracted using the 22-element modeling procedure developed in our department. The intrinsic large-signal model is deeply investigated in conjunction with linearity prediction. The accuracy of the nonlinear drain current has been enhanced through several issues such as trapping and self-heating characterization. Also, the HEMT structure thermal profile has been investigated and corresponding thermal resistance has been extracted through thermal simulation and chuck-controlled temperature pulsed I(V) and static DC measurements. Higher-order equivalent thermal model is extracted and implemented in the HEMT large-signal model to accurately estimate instantaneous channel temperature. Moreover, trapping and self-heating transients has been characterized through transient measurements. The obtained time constants are represented by equivalent sub-circuits and integrated in the nonlinear drain current implementation to account for complex communication signals dynamic prediction. The obtained verification of this table-based large-size large-signal electrothermal model implementation has illustrated high accuracy in terms of output power, gain, efficiency and nonlinearity prediction with respect to standard large-signal test signals.
Resumo:
Mode of access: Internet.
Resumo:
Differences between island- and mainland-dwelling forms provide several classic ecological puzzles. Why, for instance, are island-dwelling passerine birds consistently larger than their mainland counterparts? We examine the 'Dominance hypothesis', based on intraspecific competition, which states that large size in island passerines evolves through selection for success in agonistic encounters. We use the Heron Island population of Capricorn silvereyes (Zosterops lateralis chlorocephalus), a large-bodied island-dwelling race of white-eye (Zosteropidae), to test three assumptions of this hypothesis; that (i) large size is positively associated with high fitness, (ii) large size is associated with dominance, and (iii) the relationship between size and dominance is particularly pronounced under extreme intraspecific competition. Our results supported the first two of these assumptions, but provided mixed evidence on the third. On balance, we suggest that the Dominance Hypothesis is a plausible mechanism for the evolution of large size of island passerines, but urge further empirical tests on the role of intraspecific competition on oceanic islands versus that on mainlands.
Resumo:
RYR1 mutations are the most common cause of structural congenital myopathies and may exhibit both dominant and recessive inheritance. Histopathological findings are variable and include central cores, multi-minicores, type 1 predominance/ uniformity, fibre type disproportion, increased internal nucleation and fatty and connective tissue. Until recently, diagnostic RYR1 sequencing was limited to mutational hotspots due to the large size of the gene. Since the introduction of full RYR1 sequencing in 2007 we have detected pathogenic mutations in 77 families: 39 had dominant inheritance and 38 recessive inheritance. In some cases with presumably recessive inheritance, only one heterozygous mutation inherited from an asymptomatic parent was identified. Of 28 dominant mutations, 6 were novel; 37 of the 59 recessive mutations were also novel. Dominant mutations were more frequently in recognized hotspot regions, while recessive mutations were distributed throughout the coding sequence. Dominant mutations were predominantly missense, whereas recessive mutations included many nonsense and splice mutations expected to result in reduced RyR1 protein. There was wide clinical variability in patients with both dominant and recessive inheritance. As a group, those with dominant mutations were generally more mildly affected than those with recessive inheritance, who had earlier onset and were weaker with more functional limitations. Extraocular muscle involvement was almost exclusively observed in the recessive group. Bulbar involvement was also more prominent in this group, resulting in a larger number requiring gastrostomy insertion. In conclusion, genomic sequencing of the entire RYR1 leads to the detection of many novel mutations, but may miss large genetic rearrangements in some cases. Assigning pathogenicity to novel mutations is often difficult and interpretation of genetic results in the context of clinical, histological and, increasingly, muscle MRI findings is essential.
Resumo:
Työn tavoitteena oli selvittää, miten eri parametrit vaikuttavat monilankaisen verrannollisuuslaskurin laskennallisiin ominaisuuksiin sekä voidaanko suurikokoista monilankaverrannollisuuslaskuria käyttää tehokkaasti suurien pintojen ? - ja ?- kontaminaation mittaamiseen. Ensin selvitettiin EU:n nykyistä clearing-käytäntöä sekä hahmoteltiin tulevia materiaalivirtoja, esiteltiin verrannollisuuslaskurin ja sen monilankamallin toimintaperiaate sekä käytettävien materiaalien ominaisuudet. Kootun teorian pohjalta selvitettiin tärkeimpien parametrien vaikutus ilmaisimen laskennallisiin ominaisuuksiin. Lopuksi suoritettiin rakenteilla olevan monilankaverrannollisuuslaskurin alustava testaus. Tulevien vuosien aikana eri puolilla maailmaa suljettavat erityyppiset ydinlaitokset luovat suuren tarpeen tehokkaiden kontaminaatiomittauslaitteistojen kehittämiselle. Tällä hetkellä mittaukset suoritetaan lähinnä noin 1 dm2 käsi-instrumentein, joten suurikokoinen, automatisoitu mittauslaitteisto sekä tehostaisi mittausprosessia suuresti sekä säästäisi runsaasti miestyötunteja. Jatkotoimenpiteiksi ehdotetaan laitteiston jatkotestausta, liikkeen ja nopeuden testausta sekä lopulta paikkaherkkyystoiminnon toteuttamisperiaatteen valintaa ja testausta.
Resumo:
Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes), infarct size (percentage of the arc with infarct on 3 transverse planes), systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient). Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005). The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction) to 53.1 ± 1.5% (control) and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001) and histology (r = -0.78; P < 00001). The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7) was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3). There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.