932 resultados para Laminated glass
Resumo:
Laminatedglass is composed of two glass layers and a thin intermediate PVB layer, strongly influencing PVB's viscoelastic behaviour its dynamic response. While natural frequencies are relatively easily identified even with simplified FE models, damping ratios are not identified with such an ease. In order to determine to what extent external factors influence dampingidentification, different tests have been carried out. The external factors considered, apart from temperature, are accelerometers, connection cables and the effect of the glass layers. To analyse the influence of the accelerometers and their connection cables a laser measuring device was employed considering three possibilities: sample without instrumentation, sample with the accelerometers fixed and sample completely instrumented. When the sample is completely instrumented, accelerometer readings are also analysed. To take into consideration the effect of the glass layers, tests were realised both for laminatedglass and monolithic samples. This paper presents in depth data analysis of the different configurations and establishes criteria for data acquisition when testing laminatedglass.
Resumo:
Laminated glass is a sandwich element consisting of two or more glass sheets, with one or more interlayers of polyvinyl butyral (PVB). The dynamic response of laminated glass beams and plates can be predicted using analytical or numerical models in which the glass and the PVB are usually modelled as linear-elastic and linear viscoelastic materials, respectively. In this work the dynamic behavior of laminated glass beams are predicted using a finite element model and the analytical model of Ross-Kerwin-Ungar. The numerical and analytical results are compared with those obtained by operational modal analysis performed at different temperatures.
Resumo:
The latest technology and architectural trends have significantly improved the use of a large variety of glass products in construction which, in function of their own characteristocs, allow to design and calculate structural glass elements under safety conditions. This paper presents the evaluation and analysis of the damping properties of rectangular laminated glass plates of 1.938 m x 0.876 m with different thickness depending on the number of PVB interlayers arranged. By means of numerical simulation and experimental verification, using modal analysis, natural frequencies and damping of the glass plates were calculated, both under free boundary conditions and operational conditions for the impact test equipment used in the experimental program, as the European standard UNE-EN 12600:2003 specifies.
Resumo:
For safety barriers the load bearing capacity of the glass when subjected to the soft body impact should be verified. The soft body pendulum test became a testing standard to classify safety glass plates. The classification of the safety glass do not consider the structural behavior when one sheet of a laminated glass is broken; in situations when the replacement of the plate could not be very urgent, structural behavior should be evaluated. The main objective of this paper is to present the structural behavior o laminated glass plates, though modal test and human impact test, including the post fracture behavior for the laminated cases. A god reproducibility and repeatability is obtained. Two main aspects of the structural behavior can be observed: the increment of the rupture load for laminated plates after the failure of the first sheet, and some similarities with a tempered monolithic behavior of equivalent thickness.
Resumo:
En los últimos años, podemos darnos cuenta de la importancia que tienen las nuevas aplicaciones de vidrio especialmente en edificios turísticos donde el vértigo juega un papel importante en la visita. Sin embargo los sistemas constructivos no tienen un especial interés porque el vidrio laminado está siempre soportado por otro elemento de acero o incluso vidrio en forma de retícula. En la presente tesis voy a desarrollar una nueva solución de elemento autoportante de vidrio de gran tamaño haciendo seguro el uso del elemento para andar en el aire. El sueño de muchos arquitectos ha sido diseñar un edificio completamente transparente y a mí me gustaría contribuir a este sueño empezando a estudiar un forjado de vidrio como elemento estructural horizontal y para ello debemos cumplir requerimientos de seguridad. Uno de los objetivos es lograr un elemento lo más transparente y esbelto posible para el uso de pasarelas en vestíbulos de edificios. Las referencias construidas son bien conocidas, pero por otro lado Universidades europeas estudian continua estudiando el comportamiento del vidrio con diferentes láminas, adhesivos, apilados, insertos, sistemas de laminado, pretensado, pandeo lateral, seguridad post-rotura y muchos más aspectos necesarios. La metodología llevada a cabo en esta tesis ha sido primeramente diseñar un elemento industrial prefabricado horizontal de vidrio teniendo en cuenta todos los conceptos aprendidos en el estado del arte y la investigación para poder predimensionar el elemento. El siguiente paso será verificar el modelo por medio de cálculo analítico, simulación de elementos finitos y ensayos físicos. Para realizar los ensayos hay un paso intermedio teniendo que cambiar la hipótesis de carga uniforme a carga puntal para realizar el ensayo de flexión a 4 puntos normalizado y además cambiar a escala 1:2 para adaptarse al espacio de ensayo y ser viable económicamente. Finalmente compararé los resultados de tensión y deformación obtenidos por los tres métodos para extraer conclusiones. Sin embargo el problema de la seguridad no ha concluido, tendré que demostrar que el sistema es seguro después de que se produzca la rotura y para ello sólo dispongo de los ensayos como medio de demostración. El diseño es el resultado de la evolución de una viga tipo “I”; cuando es pretensada para obtener más resistencia, aparece el problema de pandeo lateral y éste es solucionado con una viga con sección en “T” cuya unión es resuelta con un cajeado longitudinal en la parte inferior del elemento horizontal. Las alas de éste crecen para recoger las cargas superficiales creando a su vez un punto débil en la unión que a su vez se soluciona duplicando la sección “TT” y haciendo trabajar dicho tablero de forma tan óptima como una viga continua. Dicha sección en vidrio como un único elemento pretensado es algo inédito. Además he diseñado unas escuadras metálicas en los extremos de los nervios como apoyo y placa de pretensión, así como una hendidura curva en el centro de los nervios para alojar los tirantes de acero de modo que al pretensar el tirante la placa corrija al menos la deformación por peso propio. Realizados los cambios geométricos de escala y las simplificaciones en el laminado y el adhesivo se programan la extracción de resultados desde 3 estadios diferentes: Sin pretensión y con pretensión de 750 Kg y de 1000Kg en cada nervio. Por cada estadio y por cada uno de los métodos, cálculo, simulación y ensayos, se extraen los datos de deformación y tensión en el punto medio de un nervio con el objetivo de hacer una comparación de resultados para obtener unas conclusiones, siempre en el campo de la elasticidad. Posteriormente incrementaré la carga hasta el momento de la rotura de la placa y después hasta el colapso teniendo en cuenta el tiempo y demostrando una rotura segura. El vidrio no tendrá un comportamiento plástico pero habrá sido controlado su comportamiento frágil manteniendo una carga y una deformación aceptable. ABSTRACT Over the past few years we have realized the importance of the new technologies regarding the application of glass in new buildings, especially those touristic places were the views and the heights are the reason of the visit. However, the construction systems of these glass platforms are not usually as interesting, because the laminated glass is always held by another steel substructure or even a grid-formed glass element. Throughout this thesis I am going to develop a new solution of a self-bearing element with big dimensions made out of glass, ensuring a safe solution to use as an element to walk on the air. The dream of many architects has been to create a building completely transparent, and I would like to contribute to this idea by making a glass slab as a horizontal structural element, for which we have to meet the security requirements. One of the goals is to achieve an element as transparent and slim as possible for the use in walkways of building lobbies. The glass buildings references are well known, but on the other hand the European Universities study the behaviour of the glass with different interlayers, adhesives, laminating systems, stacking, prestressed, buckling, safety, breakage and post-breakage capacity; and many other necessary aspects. The methodology followed in this thesis has been to first create a horizontal industrial prefabricated horizontal element of glass, taking into account all the concepts learned in the state of art and the investigation to be able to predimension this element. The next step will be to verify this model with an analytic calculus, a finite element modelling simulation and physical tests. To fulfil these tests there is an intermediate step, having to change the load hypothesis from a punctual one to make the test with a four points normalized deflexion, and also the scale of the sample was changed to 1:2 to adapt to the space of the test and make it economically possible. Finally, the results of tension and deformation obtained from the three methods have been compared to make the conclusions. However, the problem with safety has not concluded yet, for I will have to demonstrate that this system is safe even after its breakage, for which I can only use physical tests as a way of demonstration. The design is the result of the evolution of a typical “I” beam, which when it is prestressed to achieve more resistance, the effect of buckling overcomes, and this is solved with a “T” shaped beam, where the union is solved with a longitudinal groove on the inferior part of the horizontal element. The boards of this beam grow to cover the superficial loads, creating at the same time a weak point, which is solved by duplicating the section “TT” and therefore making this board work as optimal as a continuous beam. This glass section as a single prestressed element is unique. After the final design of the “π” glass plate was obtained and the composition of the laminated glass and interlayers has been predimensioned, the last connection elements must be contemplated. I have also designed a square steel shoe at the end of the beams, which will be the base and the prestressed board, as well as a curved slot in the centre of the nerves to accommodate the steel braces so that when this brace prestresses the board, at least the deformation due to its self-weight will be amended. Once I made the geometric changes of the scale and the simplifications on the laminating and the adhesive, the extraction on results overcomes from three different stages: without any pretension, with a pretension of 750 kg and with a pretension of 1000 kg on each rib. For each stage and for each one of the methods, calculus, simulation and tests, the deformation datum were extracted to obtain the conclusions, always in the field of the elasticity. Afterwards, I will increase the load until the moment of breakage of this board, and then until the collapse of the element, taking into account the time spent and demonstrating a safe breakage. The glass will not have a plastic behaviour, but its brittle behaviour has been controlled, keeping an acceptable load and deflection.
Resumo:
La principal aportación del trabajo es la formulación de una alternativa que facilita la determinación experimental del factor de pérdidas y, en consecuencia, mejorar las predicciones de aislamiento a ruido aéreo para vidrios con una o más capas intermedias sea cual fuere su naturaleza. Además, se realiza una revisión de las normativas relacionadas con los ensayos de los parámetros mecánicos necesarios para la caracterizar los vidrios, centrándonos en los monolíticos y los laminados. En efecto, uno de los problemas que se plantea en el contexto de la acústica de la edificación actualmente es el de cumplir con los requisitos de aislamiento acústico a ruido aéreo en fachada que exige el vigente Código Técnico de la Edificación (CTE). Como sabemos, en la fachada podemos distinguir la parte ciega y la parte hueca. La parte más débil en lo concerniente a aislamiento a ruido aéreo es la hueca (compuesta por el vidrio, carpintería y otros elementos). Si la carpintería es la adecuada, la superficie de vidrio se convierte en el elemento limitante. El Catálogo de Elementos Constructivos (CEC) del CTE, la propia norma UNE-EN 12758:2011, así como algunos, cada vez más, fabricantes ofrecen datos del aislamiento de vidrios simples, vidrios laminados y vidrios dobles. En el caso de vidrios laminados, estos datos se limitan únicamente en los que tienen un sola lámina intermedia y, además, no acústicos. Podemos hablar, por tanto, de una laguna de información en este sentido. Para obtener predicciones fiables de aislamiento acústico a ruido aéreo de particiones multicapa, como pueden ser los vidrios laminados es necesario disponer de las características mecánicas y una de las más relevantes es el factor de pérdidas.
Resumo:
Green tapes of Li(2)O-ZrO(2)-SiO(2)-Al(2)O(3) (LZSA) parent glass were produced by aqueous tape casting as the starting material for the laminated object manufacturing (LOM) process. The rheological behavior of the powder suspensions in aqueous media, as well as the mechanical properties of the cast tapes, was evaluated. According to xi potential measurements, the LZSA glass powder particles showed acid surface characteristics and an IEP of around 4 when in aqueous media. The critical volume fraction of solids was about 72 wt% (27 vol%), which hindered the processability of more concentrated slurries. The glass particles also showed an anisometric profile, which contributed to an increase in the interactions between particles during flow. Therefore, the suspensions could not be processed at high solids loadings. Aqueous-based glass suspensions were also characterized by shear thickening after the addition of dispersants. Three slurry compositions were formulated, suitable green tapes were cast, and tapes were successfully laminated by LOM to a gear wheel geometry. A higher tensile strength of the green tapes corresponded to a higher tensile strength of the laminates. Thermal treatment was then applied to the laminates: pyrolysis at 525 degrees C, sintering at 700 degrees C for 1 h, and crystallization at 850 degrees C for 30 min. A 20% volumetric shrinkage was observed, but no surface flaws or inhomogeneous areas were detected. The sintered part maintained the curved edges and internal profile after heat treatment.
Resumo:
A flexible and low cost energy harvester device based on the magnetoelectric (ME) effect has been designed using Fe64Co17Si7B12 as amorphous magnetostrictive ribbons and PVDF as the piezoelectric element. Sandwich-type laminated composite of 3 cm long has been fabricated by gluing these ribbons to the PVDF with the Devcon 5 minute epoxy. Good power output and power density of 6.4 μW and 1.5 mW/cm3, respectively, have been obtained through a multiplier circuit. All values have been measured at the magnetomechanical resonance of the laminate. The effect of the length of the ME laminate on the power output has been also studied, exhibiting a decay as the length of the ME laminate does. Nevertheless, good performance of such device has been obtained for a 0.5 cm long device, working already at 337 KHz, within the low radio frequency (LRF) range.
Resumo:
Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of μW, from an external AC field.
Resumo:
Several medical and dental schools have described their experience in the transition from conventional to digital microscopy in the teaching of general pathology and histology disciplines; however, this transitional process has scarcely been reported in the teaching of oral pathology. Therefore, the objective of the current study is to report the transition from conventional glass slide to virtual microscopy in oral pathology teaching, a unique experience in Latin America. An Aperio ScanScope® scanner was used to digitalize histological slides used in practical lectures of oral pathology. The challenges and benefits observed by the group of Professors from the Piracicaba Dental School (Brazil) are described and a questionnaire to evaluate the students' compliance to this new methodology was applied. An improvement in the classes was described by the Professors who mainly dealt with questions related to pathological changes instead of technical problems; also, a higher interaction with the students was described. The simplicity of the software used and the high quality of the virtual slides, requiring a smaller time to identify microscopic structures, were considered important for a better teaching process. Virtual microscopy used to teach oral pathology represents a useful educational methodology, with an excellent compliance of the dental students.
Resumo:
The purpose of this study was to evaluate the clinical performance of glass ionomer cement (GIC) restorations comparing two minimally invasive methods in permanent teeth after 12 months. Fifty pregnant women (second trimester of pregnancy), mean age 22 ± 5.30 years, were treated by two previously trained operators. The treatment approaches tested were: chemomechanical method (CarisolvTM; MediTeam) and atraumatic restorative treatment (ART). A split-mouth study design was used in which the two treatments were randomly placed in 50 matched pairs of permanent teeth. The chemomechanical method (CM) was the test group and the ART was the control group. The treatments were performed in Public Health Centers. The tested restorative material was a high-strength GIC (Ketac Molar; 3M/ESPE). The restorations were placed according to the ART guidelines. Two calibrated independent examiners evaluated the restorations in accordance with ART criteria. The inter-examiner kappa was 0.97. Data were analyzed using 95% confidence interval on the binomial distribution and Fisher's exact test at 5% significance level. In a 12-month follow-up, 86% of the restorations were evaluated. In the test group (CM), 100% (CI=93.3-100%) of the restorations were considered successful. In the control group (ART) 97.6% (CI=87.4-99.9%) of the restorations were considered successful and 2.4% unsuccessful (marginal defect >0.5 mm). There was no statistically significant difference between the 12-mounth success rate for both groups (Fisher's exact test: P=0.49) and between the two operators (Fisher's exact test: P=1.00). Both minimally invasive methods, chemomechanical method and ART, showed a similar clinical performance after 12 months of follow up.
Resumo:
The present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.
Resumo:
In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.
Resumo:
This study investigated the effects of the cement type and the water storage time on the push-out bond strength of a glass fiber post. Glass fiber posts (Fibrekor, Jeneric Pentron) were luted to post spaces using a self-cured resin cement (C&B Cement [CB]), a glass ionomer cement (Ketac Cem [KC]) or a resin-modified glass ionomer cement (GC FujiCEM [FC]) according to the manufacturers’ instructions. For each luting agent, the specimens were exposed to one of the following water storage times (n=5): 1 day (T1), 7 days (T7), 90 days (T90) and 180 days (T180). Push-out tests were performed after the storage times. Control specimens were not exposed to water storage, but subjected to the push-out test 10 min after post cementation. Data (in MPa) were analyzed by Kruskal-Wallis and Dunn`s test (α=0.05). Cement type and water storage time had a significant effect (p<0.05) on the push-out bond strength. CB showed significantly higher values of retention (p<0.05) than KC and FC, irrespective of the water storage time. Water storage increased significantly the push-out bond strength in T7 and T90, regardless of the cement type (p<0.05). The results showed that fiber posts luted to post spaces with the self-cured resin cement exhibited the best bonding performance throughout the 180-day water storage period. All cements exhibited a tendency to increase the bond strength after 7 and 90 days of water storage, decreasing thereafter.
Resumo:
This study evaluated the fracture resistance of weakened roots restored with glass fiber posts, composite resin cores and complete metal crowns. Thirty maxillary canines were randomly divided into 3 groups of 10 teeth each: teeth without weakened roots (control); teeth with partially weakened roots (PWR) and teeth with and largely weakened roots (LWR). The control group was restored with glass fiber posts and a composite resin core. Teeth in the PWR and LWR groups were flared internally to standardized dimensions in order to simulate root weakness. Thereafter, the roots were partially filled with composite resin and restored in the same way as in the control group. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis of the tooth until failure. Data were analyzed by one-way ANOVA and Dunnett's test for multiple comparisons (p=0.05). There were statistically significant difference differences (p<0.01) among the groups (control group = 566.73 N; PWR = 409.64 N; and LWR = 410.91 N), with significantly higher fracture strength for the control group. There was no statistically significant difference (p>0.05) between the weakened groups. The results of this study showed that thicker root dentin walls significantly increase the fracture resistance of endodontically treated teeth.