995 resultados para LOW AIRWAY PRESSURES
Resumo:
Purpose: During general anesthesia, nitrous oxide (N2O) diffuses rapidly into the air-filled laryngeal mask airway (LMA) cuff, increasing intracuff pressure. There is no clear correlation between LMA intracuff pressure and pressure on the pharynx. We have studied the effects of high LMA intracuff pressures secondary to N2O on the pharyngeal mucosa of dogs.Methods: Sixteen mongrel dogs were randomly allocated to two groups: G1 (intracuff volume, 30 mL; n = 8) breathed a mixture of O-2 (1 L.min(-1)) and air (1 L.min(-1)) and G2 (intracuff volume, 30 mL; n=8) a mixture of O-2 (1 L.min(-1)) and N2O (1 L.min(-1)). Anesthesia was induced and maintained with pentobarbitone. LMA cuff pressure was measured at zero (control), 30, 60, 90 and 120 min after #4 LMA insertion. The dogs were sacrificed, and biopsy specimens from seven predetermined areas of the pharynx in contact with the LMA cuff were collected for light (LM) and scanning electron microscopic (SEM) examination by a blinded observer.Results: LMA intracuff pressure decreased with time in G1 (P < 0.001) and increased in G2 (P < 0.001). There was a significant difference between the groups (P < 0.001). In both groups, the LM study showed a normal epithelium covering the pharyngeal mucosa and mild congestion in the subepithelial layer There were no differences between the groups (P > 0.10) or among the areas sampled (P > 0.05). In both groups, the SEM study showed a normal pharyngeal mucosa with mild superficial desquamation. Few specimens in G1 and G2 showed more intense epithelial desquamation.Conclusion: High LMA intracuff pressures produced by N2O do not increase pharyngeal mucosal injury in dogs.
Resumo:
Background: Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design: ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH(2)O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure <= 30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion: If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to the care of ARDS patients. Conversely, if the ART strategy is similar or inferior to the current evidence-based strategy (ARDSNet), this should also change current practice as many institutions routinely employ recruitment maneuvers and set PEEP levels according to some titration method.
Resumo:
Objective: To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Design: Prospective, randomized, and controlled experimental study. Setting: University research laboratory. Subjects: Wistar rats were randomly assigned to control (C) [saline (0.1 ml), intraperitoneally] and ALI [paraquat (15 mg/kg), intra peritoneally] groups. Measurements and Main Results: After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H(2)O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (Delta P2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and Delta P2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. Conclusions: In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and Delta P2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful. (Crit Care Med 2009; 37:1011-1017)
Resumo:
Evaluar si el Heliox reduce la resistencia en la vía aérea en niños y adolescentes con patología bronquial obstructiva que requieren ventilación mecánica. Materiales y Métodos: Estudio prospectivo observacional descriptivo en niños y adolescentes con patología bronquial obstructiva y ventilación mecánica con Fi02 ≤ 0,5. Medición de variables: resistencia, presión pico, presión media de la vía aérea, presión meseta, volumen corriente, autoPEEP, distensibilidad, PetCO2, ventilación de espacio muerto antes de inicio de heliox y a los 30 minutos, 2, 4, 6, 12, 18 y 24 horas y diariamente hasta suspenderlo por extubación o FiO2 > 0,5. Resultados: Resultados parciales, incluyó 9 pacientes encontrando descenso significativo de resistencia espiratoria a los 30 minutos (51,2 vs 32,3; p=0,0008 ), 2 horas ( 51,2 vs 33,4; p=0,0019) y 4 horas (51,2 vs 30,7; p=0,0012) así como de la resistencia inspiratoria a la hora 2 (48,6 vs 36,2; p = 0,013) y hora 4 (48,6 vs 30 ; p=0,004). Se observó tendencia al descenso de la PetCO2 que no fue significativa (52,3 vs 34,3: p=0,06). No se evidenció cambios en las variables; autoPEEP, presión pico, presión media de la vía aérea, distensibilidad, ventilación de espacio muerto, presión meseta y volumen corriente antes y después del inicio del Heliox. Conclusión: La ventilación mecánica con Heliox en niños con patología bronquial obstructiva parece ser que reduce de manera significativa la resistencia de la vía aérea, con tendencia al descenso de la PetC02. Se necesitan estudios prospectivos al menos observacionales analíticos que corroboren estos hallazgos.
Resumo:
Introduction: During the past years, alveolar recruitment maneuvers (RM) have produced growing interest due to their beneficial potential in pulmonary protection, and have been introduced in clinical practice. Objective: To describe and analyze the knowledge of MR and its application at seven intensive care units in the city of Cali, Colombia. Methods and materials: Descriptive Cross-Sectional Study with an intentional sample of 64 professionals working in seven intensive care units and who apply MR. The self-completed survey was made up of thirteen questions, and the application period was two months. Results: Out of 64 professionals surveyed, 77.8% of them follow a protocol guide; 54.7% employes during RM the ideal Positive end-expiratory pressure (PEEP), which maintains a saturation > 90% and a PaO2 > 60 mmHg; 42.1% tolerates airway pressures between 35 and 50 cmH2O; 48.4% perform RM with a progressive increase of the PEEP and a low tidal volume. Conclusions: Regarding the knowledge related to RM, heterogeneity was found in the answers. There is currently no consensus about which is the most effective and secure way to implement an MR. This study can be the starting point to create awareness towards the revision of knowledge, capacities and abilities that are required to perform RM.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
An investigation of nucleate boiling on a vertical array of horizontal plain tubes is presented in this paper. Experiments were performed with refrigerant RI 23 at reduced pressures varying from 0.022 to 0.64, tube pitch to diameter ratios of 1.32, 1.53 and 2.00, and heat fluxes from 0.5 to 40 kW/m(2). Brass tubes with external diameters of 19.05 mm and average roughness of 0.12 mu m were used in the experiments. The effect of the tube spacing on the local heat transfer coefficient along the tube array was negligible within the present range of experimental conditions. For partial nucleate boiling, characterized by low heat fluxes, and low reduced pressures, the tube positioning shows a remarkable effect on the heat transfer coefficient. Based on these data, a general correlation for the prediction of the nucleate boiling heat transfer coefficient on a vertical array of horizontal tubes under flooded conditions was proposed. According to this correlation, the ratio between the heat transfer coefficients of a given tube and the lowest tube in the array depends only on the tube row number, the reduced pressure and the heat flux. By using the proposed correlation, most of the experimental heat transfer coefficients obtained in the present study were predicted within +/- 15%. The new correlation compares reasonably well with independent data from the literature. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
The recently discovered mesoporous molecular sieve MCM-41 was tested as an adsorbent for VOC removal. Its adsorption/desorption properties were evaluated and compared with other hydrophobic zeolites (silicalite-1 and zeolite Y) and a commercial activated carbon, BPL. The adsorption isotherms of some typical VOCs (benzene, carbon tetrachloride, and n-hexane) on MCM-41 are of type IV according to the IUPAC classification, drastically different from the other microporous adsorbents, indicating that VOCs, in the gas phase, have to be at high partial pressures in order to make the most of the new mesoporous material as an adsorbent for VOC removal. However, a proper modification of the pore openings of MCM-41 can change the isotherm types from type IV to type I without remarkable loss of the accessible pare volumes and, therefore, significantly enhance the adsorption performance at low partial pressures. Adsorption isotherms of water on these adsorbents are all of type V, demonstrating that they possess a similar hydrophobicity. Desorption of VOCs from MCM-41 could be achieved at lower temperatures (50-60 degrees C), while this had to be conducted at higher temperatures (100-120 degrees C) for microporous adsorbents, zeolites, and activated carbons.
Resumo:
We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA), inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.
Resumo:
OBJECTIVE: To report the hemodynamic and functional responses obtained with clinical optimization guided by hemodynamic parameters in patients with severe and refractory heart failure. METHODS: Invasive hemodynamic monitoring using right heart catheterization aimed to reach low filling pressures and peripheral resistance. Frequent adjustments of intravenous diuretics and vasodilators were performed according to the hemodynamic measurements. RESULTS: We assessed 19 patients (age = 48±12 years and ejection fraction = 21±5%) with severe heart failure. The intravenous use of diuretics and vasodilators reduced by 12 mm Hg (relative reduction of 43%) pulmonary artery occlusion pressure (P<0.001), with a concomitant increment of 6 mL per beat in stroke volume (relative increment of 24%, P<0.001). We observed significant associations between pulmonary artery occlusion pressure and mean pulmonary artery pressure (r=0.76; P<0.001) and central venous pressure (r=0.63; P<0.001). After clinical optimization, improvement in functional class occurred (P< 0.001), with a tendency towards improvement in ejection fraction and no impairment to renal function. CONCLUSION: Optimization guided by hemodynamic parameters in patients with refractory heart failure provides a significant improvement in the hemodynamic profile with concomitant improvement in functional class. This study emphasizes that adjustments in blood volume result in imme-diate benefits for patients with severe heart failure.
Resumo:
OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).
Resumo:
In this thesis different parameters influencing critical flux in protein ultrafiltration and membrane foul-ing were studied. Short reviews of proteins, cross-flow ultrafiltration, flux decline and criticalflux and the basic theory of Partial Least Square analysis (PLS) are given at the beginning. The experiments were mainly performed using dilute solutions of globular proteins, commercial polymeric membranes and laboratory scale apparatuses. Fouling was studied by flux, streaming potential and FTIR-ATR measurements. Critical flux was evaluated by different kinds of stepwise procedures and by both con-stant pressure and constant flux methods. The critical flux was affected by transmembrane pressure, flow velocity, protein concentration, mem-brane hydrophobicity and protein and membrane charges. Generally, the lowest critical fluxes were obtained at the isoelectric points of the protein and the highest in the presence of electrostatic repulsion between the membrane surface and the protein molecules. In the laminar flow regime the critical flux increased with flow velocity, but not any more above this region. An increase in concentration de-creased the critical flux. Hydrophobic membranes showed fouling in all charge conditionsand, furthermore, especially at the beginning of the experiment even at very low transmembrane pressures. Fouling of these membranes was thought to be due to protein adsorption by hydrophobic interactions. The hydrophilic membranes used suffered more from reversible fouling and concentration polarisation than from irreversible foul-ing. They became fouled at higher transmembrane pressures becauseof pore blocking. In this thesis some new aspects on critical flux are presented that are important for ultrafiltration and fractionation of proteins.
Resumo:
In the present work, pineapple juice was first hydrolyzed with a commercial pectinase (Ultrazym 100 G) and then clarified by microfiltration. A tubular polyethersulfone membrane with an average cut-off of 0.3 µm and a total effective filtration area of 0.05 m² was applied. The transmembrane pressures were 1.5 and 3.0 bar, respectively, and the processes was conducted at room temperature. The results showed that the pineapple juice permeate fluxes were of 57.77 L/m²/hours (1.5 bar) and 46.85 L/m²/hours (3.0 bar). Concentration polarization and possibly fouling occurred during the processes. The best clarified juice fluxes were obtained when low transmembrane pressures (1.5 bar) were applied.
Resumo:
Platinum is one of the most common coatings used to optimize mirror reflectivity in soft X-ray beamlines. Normal operation results in optics contamination by carbon-based molecules present in the residual vacuum of the beamlines. The reflectivity reduction induced by a carbon layer at the mirror surface is a major problem in synchrotron radiation sources. A time-dependent photoelectron spectroscopy study of the chemical reactions which take place at the Pt(111) surface under operating conditions is presented. It is shown that the carbon contamination layer growth can be stopped and reversed by low partial pressures of oxygen for optics operated in intense photon beams at liquidnitrogen temperature. For mirrors operated at room temperature the carbon contamination observed for equivalent partial pressures of CO is reduced and the effects of oxygen are observed on a long time scale.