998 resultados para LIVER SURGERY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Liver remnant volumes after major hepatic resection and graft volumes for liver transplantation correlate with surgical outcome. The relative contributions of the hepatic segments to total liver volume (TLV) are not well established. METHODS: TLV and hepatic segment volumes were measured with computed tomography (CT) in 102 patients without liver disease who underwent CT for conditions unrelated to the liver or biliary tree. RESULTS: TLV ranged from 911 to 2729 cm(3). On average, the right liver (segments V, VI, VII, and VIII) contributed approximately two thirds of TLV (997+/-279 cm(3)), and the left liver (segments II, III and IV) contributed approximately one third of TLV (493+/-127 cm(3)). Bisegment II+III (left lateral section) contributed about half the volume of the left liver (242+/-79 cm(3)), or 16% of TLV. Liver volumes varied significantly between patients--the right liver varied from 49% to 82% of TLV, the left liver, 17% to 49% of TLV, and bisegment II+III (left lateral section) 5% to 27% of TLV. Bisegment II+III contributed less than 20% of TLV in more than 75% of patients and the left liver contributed 25% or less of TLV in more than 10% of patients. DISCUSSION: There is clinically significant interpatient variation in hepatic volumes. Therefore, in the absence of appreciable hypertrophy, we recommend routine measurement of the future liver remnant before extended right hepatectomy (right trisectionectomy) and in selected patients before right hepatectomy if a small left liver is anticipated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors thoroughly report the development, the technical aspects and the performance of the first navigated liver resections, by laparotomy and laparoscopy, in Brazil, done at the National Cancer Institute, Ministry of Health, using a surgical navigator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate perioperative outcomes, safety and feasibility of video-assisted resection for primary and secondary liver lesions. Methods : From a prospective database, we analyzed the perioperative results (up to 90 days) of 25 consecutive patients undergoing video-assisted resections in the period between June 2007 and June 2013. Results : The mean age was 53.4 years (23-73) and 16 (64%) patients were female. Of the total, 84% were suffering from malignant diseases. We performed 33 resections (1 to 4 nodules per patient). The procedures performed were non-anatomical resections (n = 26), segmentectomy (n = 1), 2/3 bisegmentectomy (n = 1), 6/7 bisegmentectomy (n = 1), left hepatectomy (n = 2) and right hepatectomy (n = 2). The procedures contemplated postero-superior segments in 66.7%, requiring multiple or larger resections. The average operating time was 226 minutes (80-420), and anesthesia time, 360 minutes (200-630). The average size of resected nodes was 3.2 cm (0.8 to 10) and the surgical margins were free in all the analyzed specimens. Eight percent of patients needed blood transfusion and no case was converted to open surgery. The length of stay was 6.5 days (3-16). Postoperative complications occurred in 20% of patients, with no perioperative mortality. Conclusion : The video-assisted liver resection is feasible and safe and should be part of the liver surgeon armamentarium for resection of primary and secondary liver lesions.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system’s position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device’s projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surgical treatment of liver tumours relies on precise localization of the lesions and detailed knowledge of the patient-specific vascular and biliary anatomy. Detailed three-dimensional (3D) anatomical information facilitates complete tumour removal while preserving a sufficient amount of functional liver tissue.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oncological liver surgery and interventions aim for removal of tumor tissue while preserving a sufficient amount of functional tissue to ensure organ regeneration. This requires detailed understanding of the patient-specific internal organ anatomy (blood vessel system, bile ducts, tumor location). The introduction of computer support in the surgical process enhances anatomical orientation through patient-specific 3D visualization and enables precise reproduction of planned surgical strategies though stereotactic navigation technology. This article provides clinical background information on indications and techniques for the treatment of liver tumors, reviews the technological contributions addressing the problem of organ motion during navigated surgery on a deforming organ, and finally presents an overview of the clinical experience in computer-assisted liver surgery and interventions. The review concludes that several clinically applicable solutions for computer aided liver surgery are available and small-scale clinical trials have been performed. Further developments will be required more accurate and faster handling of organ deformation and large clinical studies will be required for demonstrating the benefits of computer aided liver surgery.