896 resultados para LIGHTS CRITERIA
Resumo:
Background and objective: Light`s criteria are frequently used to evaluate the exudative or transudative nature of pleural effusions. However, misclassification resulting from the use of Light`s criteria has been reported, especially in the setting of diuretic use in patients with heart failure (HF). The objective of this study was to evaluate the utility of B-type natriuretic peptide (BNP) measurements as a diagnostic tool for determining the cardiac aetiology of pleural effusions. Methods: Patients with pleural effusions attributable to HF (n = 34), hepatic hydrothorax (n = 10), pleural effusions due to cancer (n = 21) and pleural effusions due to tuberculosis (n = 12) were studied. Diagnostic thoracentesis was performed for all 77 patients. Receiver operating characteristic (ROC) curves were constructed to determine the diagnostic accuracy of plasma BNP and pleural fluid BNP for the prediction of HF. Results: The areas under the ROC curves were 0.987 (95% CI 0.93-0.998) for plasma BNP and 0.949 (95% CI 0.874-0.986) for pleural fluid BNP, for distinguishing between patients with pleural effusions caused by HF (n = 34) and those with pleural effusions attributable to other causes (n = 43). The cut-off concentrations with the highest diagnostic accuracy for the diagnosis of HF as the cause of pleural effusion were 132 pg/mL for plasma BNP (sensitivity 97.1%, specificity 97.4%) and 127 pg/mL for pleural fluid BNP (sensitivity 97.1%, specificity 87.8%). Conclusions: In patients with pleural effusions of suspected cardiac origin, measurements of BNP in plasma and pleural fluid may be useful for the diagnosis of HF as the underlying cause.
Resumo:
Background. HIV infected women have higher rates of infertility. Objective. The purpose of this literature review is to evaluate the effectiveness of fresh IVF/ICSI cycles in HIV infected women. Materials and Methods. A search of the PubMed database was performed to identify studies assessing fresh nondonor oocyte IVF/ICSI cycle outcomes of serodiscordant couples with an HIV infected female partner. Results and Discussion. Ten studies met the inclusion criteria. Whenever a comparison with a control group was available, with the exception of one case, ovarian stimulation cancelation rate was higher and pregnancy rate (PR) was lower in HIV infected women. However, statistically significant differences in both rates were only seen in one and two studies, respectively. A number of noncontrolled sources of bias for IVF outcome were identified. This fact, added to the small size of samples studied and heterogeneity in study design and methodology, still hampers the performance of a meta-analysis on the issue. Conclusion. Prospective matched case-control studies are necessary for the understanding of the specific effects of HIV infection on ovarian response and ART outcome.
Resumo:
OBJECTIVE: The objective of this study was to analyse the use of lights and siren (L&S) during transport to the hospital by the prehospital severity status of the patient and the time saved by the time of day of the mission. METHODS: We searched the Public Health Services data of a Swiss state from 1 January 2010 to 31 December 2010. All primary patient transports within the state were included (24 718). The data collected were on the use of L&S, patient demographics, the time and duration of transport, the type of mission (trauma vs. nontrauma) and the severity of the condition according to the National Advisory Committee for Aeronautics (NACA) score assigned by the paramedics and/or emergency physician. We excluded 212 transports because of missing data. RESULTS: A total of 24 506 ambulance transports met the inclusion criteria. L&S were used 4066 times, or in 16.6% of all missions. Of these, 40% were graded NACA less than 4. Overall, the mean total transport time to return to the hospital was 11.09 min (confidence interval 10.84-11.34) with L&S and 12.84 min (confidence interval 12.72-12.96) without. The difference was 1.75 min (105 s; P<0.001). For night-time runs alone, the mean time saved using L&S was 0.17 min (10.2 s; P=0.27). CONCLUSION: At present, the use of L&S seems questionable given the severity status or NACA score of transported patients. Our results should prompt the implementation of more specific regulations for L&S use during transport to the hospital, taking into consideration certain physiological criteria of the victim as well as time of day of transport.
Resumo:
The aim of this paper is to analyse how learning assessment, particularly the Continuous Assessment system, has been defined in the Public Administration and Management Diploma Course of the University of Barcelona (Spain). This course was a pioneering experiment at this university in implementing the guidelines of the European Higher Education Area (EHEA), and thus represents a good case study for verifying whether one of the cornerstones of the EHEA has been accomplished with success. Using data obtained from the Teaching Plans elaborated by the lecturers of each subject, we are able to establish that the CA system has been progressively accepted to such an extent that it is now the assessment formula used by practically all of the lecturers, conforming in this way to the protocols laid down by the Faculty of Law in which this diploma course is taught. Nevertheless, we find that high dispersion exists in how Continuous Assessment is actually defined. Indeed, it seems that there is no unified view of how Continuous Assessment should be performed. This dispersion, however, seems to diminish over time and raises some questions about the advisability of agreement on criteria, considering the potential which CA has as a pedagogical tool. Moreover, we find that the Unique Assessment system, which students may also apply for, is an option chosen only by a minority, with lecturers usually defining it as merely a theoretical and/or practical test, of little innovation in relation to traditional tests.
Resumo:
The aim of this paper is to analyse how learning assessment, particularly the Continuous Assessment system, has been defined in the Public Administration and Management Diploma Course of the University of Barcelona (Spain). This course was a pioneering experiment at this university in implementing the guidelines of the European Higher Education Area (EHEA), and thus represents a good case study for verifying whether one of the cornerstones of the EHEA has been accomplished with success. Using data obtained from the Teaching Plans elaborated by the lecturers of each subject, we are able to establish that the CA system has been progressively accepted to such an extent that it is now the assessment formula used by practically all of the lecturers, conforming in this way to the protocols laid down by the Faculty of Law in which this diploma course is taught. Nevertheless, we find that high dispersion exists in how Continuous Assessment is actually defined. Indeed, it seems that there is no unified view of how Continuous Assessment should be performed. This dispersion, however, seems to diminish over time and raises some questions about the advisability of agreement on criteria, considering the potential which CA has as a pedagogical tool. Moreover, we find that the Unique Assessment system, which students may also apply for, is an option chosen only by a minority, with lecturers usually defining it as merely a theoretical and/or practical test, of little innovation in relation to traditional tests.
Resumo:
The aim of this paper is to analyse how learning assessment, particularly the Continuous Assessment system, has been defined in the Public Administration and Management Diploma Course of the University of Barcelona (Spain). This course was a pioneering experiment at this university in implementing the guidelines of the European Higher Education Area (EHEA), and thus represents a good case study for verifying whether one of the cornerstones of the EHEA has been accomplished with success. Using data obtained from the Teaching Plans elaborated by the lecturers of each subject, we are able to establish that the CA system has been progressively accepted to such an extent that it is now the assessment formula used by practically all of the lecturers, conforming in this way to the protocols laid down by the Faculty of Law in which this diploma course is taught. Nevertheless, we find that high dispersion exists in how Continuous Assessment is actually defined. Indeed, it seems that there is no unified view of how Continuous Assessment should be performed. This dispersion, however, seems to diminish over time and raises some questions about the advisability of agreement on criteria, considering the potential which CA has as a pedagogical tool. Moreover, we find that the Unique Assessment system, which students may also apply for, is an option chosen only by a minority, with lecturers usually defining it as merely a theoretical and/or practical test, of little innovation in relation to traditional tests.
Resumo:
INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.
Resumo:
In Brazil, the consumption of extra-virgin olive oil (EVOO) is increasing annually, but there are no experimental studies concerning the phenolic compound contents of commercial EVOO. The aim of this work was to optimise the separation of 17 phenolic compounds already detected in EVOO. A Doehlert matrix experimental design was used, evaluating the effects of pH and electrolyte concentration. Resolution, runtime and migration time relative standard deviation values were evaluated. Derringer's desirability function was used to simultaneously optimise all 37 responses. The 17 peaks were separated in 19min using a fused-silica capillary (50μm internal diameter, 72cm of effective length) with an extended light path and 101.3mmolL(-1) of boric acid electrolyte (pH 9.15, 30kV). The method was validated and applied to 15 EVOO samples found in Brazilian supermarkets.
Resumo:
Muscle strength and functional independence are considered to be determinants of frailty levels among elderly people. The aim here was to compare lower-limb muscle strength (LLMS) with functional independence in relation to sex, age and number of frailty criteria, and to ascertain the influence of these variables on elderly outpatients' independence. Quantitative cross-sectional study, in a tertiary hospital. The study was conducted on 150 elderly outpatients of both sexes who were in a cognitive condition allowing oral communication, between October 2005 and October 2007. The following instruments were used: five-times sit-to-stand test (FTSST), Functional Independence Measurement (FIM) and Lawton's Instrumental Activities of Daily Living Scale (IADL). Descriptive, comparative, multivariate, univariate and Cronbach alpha analyses were performed. The mean time taken in the FTSST was 21.7 seconds; the mean score for FIM was 82.2 and for IADL was 21.2; 44.7% of the subjects presented 1-2 frailty criteria and 55.3% > 3 criteria. There was a significant association between LLMS and functional independence in relation to the number of frailty criteria, without homogeneity regarding sex and age. Functional independence showed significant influence from sex and LLMS. Elderly individuals with 1 or 2 frailty criteria presented greater independence in all FTSST scores. The subjects with higher LLMS presented better functional independence.
Resumo:
We compared the indication of laparoscopy for treatment of adnexal masses based on the risk scores and tumor diameters with the indication based on gynecology-oncologists' experience. This was a prospective study of 174 women who underwent surgery for adnexal tumors (116 laparotomies, 58 laparoscopies). The surgeries begun and completed by laparoscopy, with benign pathologic diagnosis, were considered successful. Laparoscopic surgeries that required conversion to laparotomy, led to a malignant diagnosis, or facilitated cyst rupture were considered failures. Two groups were defined for laparoscopy indication: (1) absence of American College of Obstetrics and Gynecology (ACOG) guideline for referral of high-risk adnexal masses criteria (ACOG negative) associated with 3 different tumor sizes (10, 12, and 14 cm); and (2) Index of Risk of Malignancy (IRM) with cutoffs at 100, 200, and 300, associated with the same 3 tumor sizes. Both groups were compared with the indication based on the surgeon's experience to verify whether the selection based on strict rules would improve the rate of successful laparoscopy. ACOG-negative and tumors ≤10 cm and IRM with a cutoff at 300 points and tumors ≤10cm resulted in the same best performance (78% success = 38/49 laparoscopies). However, compared with the results of the gynecology-oncologists' experience, those were not statistically significant. The selection of patients with adnexal mass to laparoscopy by the use of the ACOG guideline or IRM associated with tumor diameter had similar performance as the experience of gynecology-oncologists. Both methods are reproducible and easy to apply to all women with adnexal masses and could be used by general gynecologists to select women for laparoscopic surgery; however, referral to a gynecology-oncologist is advisable when there is any doubt.
Resumo:
The 2005 National Institutes of Health (NIH) Consensus Conference proposed new criteria for diagnosing and scoring the severity of chronic graft-versus-host disease (GVHD). The 2014 NIH consensus maintains the framework of the prior consensus with further refinement based on new evidence. Revisions have been made to address areas of controversy or confusion, such as the overlap chronic GVHD subcategory and the distinction between active disease and past tissue damage. Diagnostic criteria for involvement of mouth, eyes, genitalia, and lungs have been revised. Categories of chronic GVHD should be defined in ways that indicate prognosis, guide treatment, and define eligibility for clinical trials. Revisions have been made to focus attention on the causes of organ-specific abnormalities. Attribution of organ-specific abnormalities to chronic GVHD has been addressed. This paradigm shift provides greater specificity and more accurately measures the global burden of disease attributed to GVHD, and it will facilitate biomarker association studies.
Resumo:
Dados secundários de uma amostra aleatória de pré-escolares brasileiros foram analisados com o objetivo de avaliar a prevalência de desvios oclusais na dentição decídua, que podem adversamente afetar a dentição permanente, com base em critérios revisados. Overjet e overbite apresentaram pontos de corte descritos na literatura para a remoção dos casos de má oclusão leve. Overjet > 3mm e overbite > 3mm afetaram 16% e 7% das crianças, respectivamente. No plano sagital foram consideradas apenas as taxas de desvios bilaterais: relação molar em degrau distal (9,7%) e mesial (6,0%); relação dos caninos Classe 2 (11,0%) e Classe 3 (2,9%). Para os demais desvios não foram relatados na literatura critérios de severidade. Valores brutos de mordida aberta anterior (27,9%); mordida cruzada posterior (11,3%); apinhamento dentário maxilar (7,0%) e mandibular (11,3%) foram registrados. A avaliação da má oclusão na dentição decídua deve considerar a severidade dos desvios para a identificação de casos e não-casos de relevância em saúde pública. Enfatiza-se a necessidade de maior consenso e melhora na interpretação de dados epidemiológicos sobre a má oclusão nesse estágio de desenvolvimento
Resumo:
Objective To examine the ability of the criteria proposed by the WHO to identify pneumonia among cases presenting with wheezing and the extent to which adding fever to the criteria alters their performance. Design Prospective classification of 390 children aged 2-59 months with lower respiratory tract disease into five diagnostic categories, including pneumonia. WHO criteria for the identification of pneumonia and a set of such criteria modified by adding fever were compared with radio-graphically diagnosed pneumonia as the gold standard. Results The sensitivity of the WHO criteria was 94% for children aged <24 months and 62% for those aged >= 24 months. The corresponding specificities were 20% and 16%. Adding fever to the WHO criteria improved specificity substantially (to 44% and 50%, respectively). The specificity of the WHO criteria was poor for children with wheezing (12%). Adding fever improved this substantially (to 42%). The addition of fever to the criteria apparently reduced their sensitivity only marginally (to 92% and 57%, respectively, in the two age groups). Conclusion The authors' results reaffirm that the current WHO criteria can detect pneumonia with high sensitivity, particularly among younger children. They present evidence that the ability of these criteria to distinguish between children with pneumonia and those with wheezing diseases might be greatly enhanced by the addition of fever.
Resumo:
A combination of an extension of the topological instability ""lambda criterion"" and a thermodynamic criterion were applied to the Al-La system, indicating the best range of compositions for glass formation. Alloy compositions in this range were prepared by melt-spinning and casting in an arc-melting furnace with a wedge-section copper mold. The GFA of these samples was evaluated by X-ray diffraction, differential scanning calorimetry and scanning electron microscopy. The results indicated that the gamma* parameter of compositions with high GFA is higher, corresponding to a range in which the lambda parameter is greater than 0.1, which are compositions far from Al solid solution. A new alloy was identified with the best GFA reported so far for this system, showing a maximum thickness of 286 mu m in a wedge-section copper mold. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.
Resumo:
This work evaluates the glass formation of selected alloys based on the Ti-Zr-Fe-Co system, assuming the synergy of two distinct criteria: minimum topological instability and average electronegativity plots. Combining the minimum topological instability and the average electronegativity values result in a plot in which the most probable good glass former compositions are identified Ti-Zr rich alloys with Fe and Co additions were produced, compared against the final plot, and the best glass forming alloy composition was found to be very close the theoretically predicted ones on the Ti-Zr rich side, for both Ti-Zr-Fe and Ti-Zr-Co systems. (C) 2009 Elsevier B V All rights reserved