210 resultados para LIGHTNING ARRESTERS
Resumo:
Lightning-induced overvoltages have a considerable impact on the power quality of overhead distribution and telecommunications systems, and various models have been developed for the computation of the electromagnetic transients caused by indirect strokes. The most adequate has been shown to be the one proposed by Agrawal et al.; the Rusck model can be visualized as a particular case, as both models are equivalent when the lightning channel is perpendicular to the ground plane. In this paper, an extension of the Rusck model that enables the calculation of lightning-induced transients considering flashes to nearby elevated structures and realistic line configurations is tested against data obtained from both natural lightning and scale model experiments. The latter, performed under controlled conditions, can be used also to verify the validity of other coupling models and relevant codes. The so-called Extended Rusck Model, which is shown to be sufficiently accurate, is applied to the analysis of lightning-induced voltages on lines with a shield wire and/or surge arresters. The investigation conducted indicates that the ratio between the peak values of the voltages induced by typical first and subsequent strokes can be either greater or smaller than the unity, depending on the line configuration.
Resumo:
As wind power generation undergoes rapid growth, lightning and overvoltage incidents involving wind power plants have come to be regarded as a serious problem. Firstly, lightning location systems are discussed, as well as important parameters regarding lightning protection. Also, this paper presents a case study, based on a wind turbine with an interconnecting transformer, for the study of adequate lightning and overvoltage protection measures. The electromagnetic transients circuit under study is described, and computational results are presented.
Resumo:
This paper presents an investigation into cloud-to-ground lightning activity over the continental territory of Portugal with data collected by the national Lightning Location System. The Lightning Location System in Portugal is first presented. Analyses about geographical, seasonal, and polarity distribution of cloud-to-ground lightning activity and cumulative probability of peak current are carried out. An overall ground flash density map is constructed from the database, which contains the information of more than five years and almost four million records. This map is compared with the thunderstorm days map, produced by the Portuguese Institute of Meteorology, and with the orographic map of Portugal. Finally, conclusions are duly drawn.
Resumo:
This paper is concerned with the protection of wind energy systems against the indirect effects of lightning. As wind energy is gaining increasing importance throughout the world, lightning damages involving wind energy systems have come to be regarded with more attention. Nevertheless, there are still very few studies in Portugal regarding lightning protection of wind energy systems using models of the Electro-Magnetic Transients Program (EMTP). Hence, a new case study is presented in this paper, based on a wind turbine with an interconnecting transformer, considering that lightning strikes the soil near the tower at a distance such that galvanic coupling occurs through the grounding electrode. Computer simulations obtained by using EMTP-RV are presented and conclusions are duly drawn. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
As wind power generation undergoes rapid growth, lightning damages involving wind turbines have come to be regarded with more attention. Electric and magnetic fields generated by lightning represent a serious hazard to wind turbines. A new case study is presented with two interconnected wind turbines, considering that lightning strikes directly the blade of one wind turbine. Computer simulations obtained by using EMTP-RV are presented and conclusions are duly drawn.
Resumo:
This paper is concerned with direct or indirect lightning strokes on wind turbines, studying overvoltages and electromagnetic transients. As wind power generation undergoes rapid growth, lightning damages involving wind turbines have come to be regarded with more attention. With the aim of providing further insights into the lightning protection of wind turbines, describing the transient behavior in an accurate way, the restructured version (RV) of the electromagnetic transients program (EMTP) is used in this paper. A new case study is presented with two interconnected wind turbines, considering a direct lightning stroke to the blade or considering that lightning strikes the soil near a tower. Comprehensive computer simulations with EMTP-RV are presented and conclusions are duly drawn.
Resumo:
Some results of investigations of the connection of the parameters of thunderstorm activity with the air electrical conductivity are represented.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
A new parameter is introduced: the lightning potential index (LPI), which is a measure of the potential for charge generation and separation that leads to lightning flashes in convective thunderstorms. The LPI is calculated within the charge separation region of clouds between 0 C and 20 C, where the noninductive mechanism involving collisions of ice and graupel particles in the presence of supercooled water is most effective. As shown in several case studies using the Weather Research and Forecasting (WRF) model with explicit microphysics, the LPI is highly correlated with observed lightning. It is suggested that the LPI may be a useful parameter for predicting lightning as well as a tool for improving weather forecasting of convective storms and heavy rainfall.
Resumo:
Monitoring thunderstorms activity is an essential part of operational weather surveillance given their potential hazards, including lightning, hail, heavy rainfall, strong winds or even tornadoes. This study has two main objectives: firstly, the description of a methodology, based on radar and total lightning data to characterise thunderstorms in real-time; secondly, the application of this methodology to 66 thunderstorms that affected Catalonia (NE Spain) in the summer of 2006. An object-oriented tracking procedure is employed, where different observation data types generate four different types of objects (radar 1-km CAPPI reflectivity composites, radar reflectivity volumetric data, cloud-to-ground lightning data and intra-cloud lightning data). In the framework proposed, these objects are the building blocks of a higher level object, the thunderstorm. The methodology is demonstrated with a dataset of thunderstorms whose main characteristics, along the complete life cycle of the convective structures (development, maturity and dissipation), are described statistically. The development and dissipation stages present similar durations in most cases examined. On the contrary, the duration of the maturity phase is much more variable and related to the thunderstorm intensity, defined here in terms of lightning flash rate. Most of the activity of IC and CG flashes is registered in the maturity stage. In the development stage little CG flashes are observed (2% to 5%), while for the dissipation phase is possible to observe a few more CG flashes (10% to 15%). Additionally, a selection of thunderstorms is used to examine general life cycle patterns, obtained from the analysis of normalized (with respect to thunderstorm total duration and maximum value of variables considered) thunderstorm parameters. Among other findings, the study indicates that the normalized duration of the three stages of thunderstorm life cycle is similar in most thunderstorms, with the longest duration corresponding to the maturity stage (approximately 80% of the total time).
Resumo:
We describe how an electromagnetic wave after a lightning strike affected a university hospital, including the communication shutdown that followed, the way it was handled, and the lessons learned from this incident.
Resumo:
Power transformer is the most expensive equipment on a substation. It is always necessary to get needed benefit with the lowest expenses. Producing of power transformers with reduced insulation strength is one of the possible ways to reduce expenses. Exploitation of such transformers was begun in the end of 70-th in the last century. Protection from overvoltages was done with valve-type magnetic combined surge arresters with increased blanking voltage during switching overvoltages. Nowadays there is the necessity of replacement of those devices. That’s why modernized nonlinear surge arrester was invented. This master’s thesis is focused on the use research of that modernized device in comparison with usual nonlinear surge arresters. The goal is to show the lightning overvoltages level using different types of nonlinear surge arresters and then calculations of the lightning protection reliability.
Resumo:
Lightning Fastener Co. Ltd. was a zipper manufacturer located on Niagara Street in St. Catharines. It was founded by Gideon Sundback, the inventor of the modern fastener. Sundback was born in Sweden, but settled in the United States in 1905. It was here that he designed and patented a “separable fastener” in 1913. Although he lived in Hoboken, New Jersey, he decided to establish a manufacturing facility for his invention in Canada, choosing St. Catharines over other locations such as Fort Erie and Hamilton. At the height of its success, the company employed more than 500 people and produced more than 50 million zippers annually. Over time, the company had difficulty remaining competitive and was forced to close in 1981.