938 resultados para LC filter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the thesis is to investigate the hybrid LC filter behavior in modern power drives; to analyze the influence of such a du/dt filter on the control system stability. With the implementation of the inverter output RLC filter the motor control becomes more complicated. And during the design process the influence of the filter on the motor should be considered and the filter RLC parameters should be constrained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Suuritehoisissa pumppu- ja puhallinkäytöissä käytetään usein suurnopeusmoottoria,jota syötetään välijännitteellä. Suurjännitetaajuudenmuuttajat ovat kalliita, eikä niitä ole aina edes mahdollista valmistaa. Tutkimuksen kohteena on rinnakkaisilla pienjännitetaajuudenmuuttajilla toteutettu sähkökäyttö, jossa pienjännite nostetaan moniensiöisellä muuntajalla suurjännitteeksi (6,6 kV) ja syötetään edelleen kuormana olevalle suurnopeusmoottorille. Opinnäytetyössä tutkitaan moniensiöisen muuntajan syöttöä rinnakkaisilla taajuudenmuuttajilla sekä niiden aiheuttamia häiriöitä toisilleen. Työssä tutkitaan myös harmonisten yliaaltojen vaikutuksia muuntajan häviöihin ja magnetointiominaisuuksiin. Taajuudenmuuttajan lähtöjännite ja -virta suodatetaan sinisuotimella, jonka parametreja simuloidaan Simulink- ohjelmistolla. Tavoite on löytää optimaaliset parametrit taajuudenmuuttajanlähtösuotimelle käyrämuotojen ja suotimeen jäävän tehon suhteen. Työssä tarkasteltiin sinisuodinta, johon jää 3 prosenttia syöttöjännitteestä. LC-suodin kompensoi sähkökäytön loistehon lähes kokonaan, joten taajuudenmuuttajien antotehon kannalta suotimet ovat perusteltuja. Taajuudenmuuttajan näennäisteho putoaa 22 prosenttia, joten taajuudenmuuttajat voidaan vastaavasti mitoittaa pienemmiksi.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pienjännitejakeluverkko Suomessa on toteutettu 400 V:n kolmivaiheisella vaihtosähköllä. Pienestä jännitteestä johtuen 20/0.4 kV:n muuntajat täytyy sijoittaa lähelle kuluttajaa, jotta siirtohäviöt eivät nouse liian suuriksi. Suuremman vaihto- tai tasajännitteen käyttö pienjännitejakelussa kasvattaisi verkon tehonsiirtokapasiteettia ja mahdollistaisi pidempien siirtomatkojen käytön. Käynnissä olevassa tutkimushankkeessa käsitellään vaihtoehtoa, jossa tasajännitettä käytettäisiin 20 kV:n verkon ja kuluttajan välisessä tehonsiirrossa ja kuluttajalla sijaitseva vaihtosuuntaaja muodostaisi tasasähköstä standardien mukaista yksi- tai kolmivaiheista vaihtosähköä. Tässä diplomityössä käsitellään tehoelektroniikan soveltamista kuluttajalle sijoitetussa vaihtosuuntaajassa. Työssä tarkastellaan yksivaiheisia invertteritopologioita, niiden ohjausta ja soveltamista erilaisissa vaihtosuuntaajaratkaisuissa sekä LC- ja LCL-suotimien soveltuvuutta invertterin lähtöjännitteen suodatukseen. Lisäksi esitellään erilaisia rakenneratkaisuja vaihtosuuntauksen toteutukseen ja tarkastellaan näiden järjestelmien vikatilanteita ja sähköturvallisuutta. Lopuksi käsitellään koko järjestelmän häviöitä ja hyötysuhdetta eri suodinkomponenteilla sekä kytkentätaajuuksilla ja esitellään laboratorioprototyyppi. Työssä saatiin selville, että puolisiltainvertteri ei sovellu suurten kondensaattorien vuoksi syöttämään verkkotaajuista kuormaa, vaan joudutaan käyttämään kokosiltainvertteriä. Kokosiltainvertterin ja LC- tai LCL-suotimen käsittävää kokonaisuutta tarkasteltaessa havaittiin, että pienimmät häviöt saavutetaan LC-suotimella 5 %:n ja LCL-suotimella 1 %:n särövaatimuksella. Hyötysuhdekäyrää tarkasteltaessa saatiin sama tulos läpi koko invertterin tehoalueen. Suotimen häviöiden tarkka laskenta on kuitenkin erittäin haasteellista, joten tulokset ovat suuntaa-antavia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työssä tarkastellaan olemassa olevan suoraa vääntömomentin säätöä käyttävän taajuudenmuuttajan soveltamista keskitaajuusalueella toimiviin induktiomoottorikäyttöihin. Keskinopeusalueen sovellusten pyörimisnopeudet ovat tyypillisesti 6000…30000rpm. Tällöin invertterin lähtötaajuuden on nelinapaista moottoria ohjattaessa ulotuttava 1000Hz:iin. ABB:n ACS600 taajuudenmuuttajan nykyinen syöttötaajuus ulottuu noin 400Hz:iin ja sen keskimääräinen kytkentätaajuus on luokkaa 3kHz. Taajuudenmuuttajan keskimääräistä kytkentätaajuutta ei haluta tästä merkittävästi nostaa, koska tällöin pääteasteen mitoitusta ja rakennetta on muutettava. Tarkastelussa keskitytään täten jännitemodulointiin, joka määrittelee invertterin lähtöjännitteen käyrämuodon ja pääteasteen tehokytkimien kytkentätaajuuden. Työssä esitetään suoran käämivuon säädön periaatetta soveltava 30-kulmainen modulointimenetelmä (30-modulointi), jolla moottorin syöttövirrasta voidaan eliminoida 5. ja 7. yliharmoninen komponentti. Yliharmonisten komponenttien eliminointi mahdollistaa passiivisilla komponenteilla toteutetun alipäästösuodattimen asentamisen invertterin lähtöön, jolloin moottorissa tapahtuvat tehohäviöt saadaan pieniksi. 30-moduloinnin ohjaukseen ja säätöön esitetään menetelmät, jotka mahdollistavat sen toteuttamisen nykyiseen taajuudenmuuttajaan ohjelmallisesti ilman suuria laitteistomuutoksia. 30-moduloinnin ominaisuuksia tarkastellaan analyyttisin menetelmin ja sen toimintaa testataan esitettyjen teorioiden perusteella simuloimalla. 30-moduloinnin ohjelmallinen implementointi nykyiseen ACS600:een mahdollistaa periaatteessa noin 600Hz:n syöttötaajuuden saavuttamisen. Tällöin invertterin keskimääräinen kytkentätaajuus voidaan säätää koko pyörimisnopeusalueella alle 4kHz:n tasolle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Invertteritekniikalla voidaan toteuttaa nykyaikainen, monipuolinen ja tehokas pääteaste moneen eri käyttötarkoitukseen. Tässä työssä suunnitellaan invertteripääteaste mittalaite- ja virtalähdesovelluksiin. Suunnittelussa otetaan huomioon muunneltavuus, valmistuskustannukset ja mitat. Näiden kriteerien lisäksi pääteaste suunnitellaan niin, että se täyttää mittalaite- ja virtalähdesovelluksien vaatimat standardit. Pääteasteen teho rajoittuu 500 VA:iin, mutta vaatimukset lähtöjännitteen erimuotoisuudelle aiheuttavat suunnittelulle omat vaikeutensa. Työssä täytyy tutkia, minkälainen tuloaste, invertteri, suodin ja lähtöaste sopivat parhaiten pääteasteen toteutukseen. Sopivien topologioiden löydyttyä pääteaste simuloidaan tietokoneella, jonka jälkeen voidaan suunnitella prototyyppi käytännön testauksia varten. Suunnittelussa päädyttiin seuraaviin topologioihin: Tuloasteeksi valittiin PFC-piiri, joka on nykyaikana pakollinen invertterikäytössä, koska verkkoon palaavat harmoniset yliaaltokomponentit täytyy suodattaa. Invertteritopologiaksi valittiin kokosiltainvertteri, jolla saadaan parhaiten muutettua lähtöjännitteen taajuutta ja amplitudia. Suodintopologiaksi valittiin LC-suodin, jolla saadaan tehokkaasti suodatettua invertterin aiheuttamat harmoniset yliaallot. Lähtöön sijoitetaan muuntaja, jonka muuntosuhdetta muuntamalla saadaan lähtöjännite halutuksi eri käyttötarkoituksia varten.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Suomessa sähkönjakeluverkko koostuu pääasiassa 20 kV ja 400 V jännitetasoista. Tällöin sähkö viedään lähelle kuluttajia suuremmalla jännitetasolla ja muunnetaan alhaisemmaksi lähellä asiakkaita. Haittapuolena on se, että haja-asutusalueilla jakelumuuntajien määrä kasvaa suureksi, koska ne täytyy sijoittaa lähelle kuluttajaa. Vaihtoehtona on toteuttaa osa sähkönjakelusta tasajännitteellä, jolloin tehollinen jännite olisi suurempi. Tällöin sähköä voitaisiin siirtää pidempiä matkoja ilman, että asiakaskohtaisia tai muutaman asiakkaan kattavia 20 kV siirtolinjoja tarvitsisi käyttää. Tämä taasen edellyttää asiakaskohtaisien vaihtosuuntaajien käyttöä. Tässä työssä esiteltävällä 1 kVA vaihtosuuntaajalla muodostetaan tasasähköjakeluverkosta saatavasta 750 V tasasähköstä yksivaiheista (230 VRMS, 50 Hz) verkkojännitettä. Laite on suunniteltu toteuttamaan galvaaninen erotus mahdollisimman hyvän hyötysuhteen puitteissa. Vaihtosuuntaaja on toteutettu käyttämällä resonanssikonvertteria, joka vaihtosuuntaa jakelujännitteen korkeataajuiseksi vaihtojännitteeksi. Tämän jälkeen toteutetaan galvaaninen erotus käyttäen suurtaajuusmuuntajaa. Tätä seuraa syklokonvertteri, joka pulssintiheysmodulaatiota soveltaen muodostaa lähtöjännitteen. Tämä suodatetaan lopuksi LC- alipäästösuotimella säröltään standardin mukaiseksi. Laite on jaettu työssä kolmeen osaan, joista jokaisen toiminta on selitetty ja simuloitu itsenäisesti. Lopussa koko järjestelmä on simuloitu yhtenä kokonaisuutena. Hyötysuhteeksi arvioitiin karkeasti 94 % ja lopullisista tuloksista voidaan päätellä, että laitteen toteuttaminen prototyypiksi voisi olla kannattavaa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulse-width modulation is widely used to control electronic converters. One of the most topologies used for high DC voltage/low DC voltage conversion is the Buck converter. It is obtained as a second order system with a LC filter between the switching subsystem and the load. The use of a coil with an amorphous magnetic material core instead of air core lets design converters with smaller size. If high switching frequencies are used for obtaining high quality voltage output, the value of the auto inductance L is reduced throughout the time. Then, robust controllers are needed if the accuracy of the converter response must not be affected by auto inductance and load variations. This paper presents a robust controller for a Buck converter based on a state space feedback control system combined with an additional virtual space variable which minimizes the effects of the inductance and load variations when a not-toohigh switching frequency is applied. The system exhibits a null steady-state average error response for the entire range of parameter variations. Simulation results are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulse-width modulation is widely used to control electronic converters. One of the most frequently used topologies for high DC voltage/low DC voltage conversion is the Buck converter. These converters are described by a second order system with an LC filter between the switching subsystem and the load. The use of a coil with an amorphous magnetic material core rather than an air core permits the design of smaller converters. If high switching frequencies are used to obtain high quality voltage output, then the value of the auto inductance L is reduced over time. Robust controllers are thus needed if the accuracy of the converter response must be preserved under auto inductance and payload variations. This paper presents a robust controller for a Buck converter based on a state space feedback control system combined with an additional virtual space variable which minimizes the effects of the inductance and load variations when a switching frequency that is not too high is applied. The system exhibits a null steady-state average error response for the entire range of parameter variations. Simulation results and a comparison with a standard PID controller are also presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Asteraceae family is spread worldwide. In Portugal, there are more than 300 species, standing out as one of the botanical families with largest representation in the Portuguese flora. Coleostephus myconis (L.) Rchb.f. is a scarcely studied Asteraceae species, characterized as having ruderal growth and persistence in abandoned soils (an expanding problem due to the desertification phenomena in rural areas). In this work, the flowers of C. myconis were collected in three different flowering stages (i: flower bud; ii: flower in anthesis; iii: senescent flower) from the Northwestern area of the Portuguese territory. Powdered samples (1 g) were extracted twice with ethanol:water 50:50 (v/v). After removing solvents, the combined extracts were re-dissolved, filtered through 0.22-μm disposable LC filter disks and analyzed by high performance liquid chromatography coupled to a diode array detector and electrospray ionization-mass spectrometry (HPLC-DAD/ESI-MS). The phenolic compounds were characterized according to their UV and mass spectra, and retention times. For the quantitative analysis, calibration curves of standard compounds were used. According to the UV spectra (λmax = 314-330 nm) and pseudomolecular ions ([M-H]-) at m/z 353 and 515, all producing an m/z 191 ion, four compounds derived from quinic acid were detected: 3-O-caffeoylquinic acid (Figure 1A), 5-O-caffeoylquinic acid (Figure 1B), 3,5-O-dicaffeoylquinic acid (Figure 1C) and 4,5-O-dicaffeoylquinic acid (Figure 1D), as also supported by the literature [1,2]. A fifth phenolic acid was identified as protocatechuic acid. The detected flavonoid were quercetin-O-glucuronide, quercetin-3-Oglucoside, myricetin-O-methyl-hexoside and a second glycosylated myricetin (not possible to identify completely). Some statistically significant changes were detected among the different assayed flowering stages; nevertheless, 3,5-O-dicaffeoylquinic acid was the major compound, independently of the phenologic stage. According to the previous results, C. myconis might be considered as a potential natural source of these valuable bioactive compounds, especially considering the high botanical representativeness of this plant and its inexpensiveness.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Because of the various matrices available for forensic investigations, the development of versatile analytical approaches allowing the simultaneous determination of drugs is challenging. The aim of this work was to assess a liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform allowing the rapid quantification of colchicine in body fluids and tissues collected in the context of a fatal overdose. For this purpose, filter paper was used as a sampling support and was associated with an automated 96-well plate extraction performed by the LC autosampler itself. The developed method features a 7-min total run time including automated filter paper extraction (2 min) and chromatographic separation (5 min). The sample preparation was reduced to a minimum regardless of the matrix analyzed. This platform was fully validated for dried blood spots (DBS) in the toxic concentration range of colchicine. The DBS calibration curve was applied successfully to quantification in all other matrices (body fluids and tissues) except for bile, where an excessive matrix effect was found. The distribution of colchicine for a fatal overdose case was reported as follows: peripheral blood, 29 ng/ml; urine, 94 ng/ml; vitreous humour and cerebrospinal fluid, < 5 ng/ml; pericardial fluid, 14 ng/ml; brain, < 5 pg/mg; heart, 121 pg/mg; kidney, 245 pg/mg; and liver, 143 pg/mg. Although filter paper is usually employed for DBS, we report here the extension of this alternative sampling support to the analysis of other body fluids and tissues. The developed platform represents a rapid and versatile approach for drug determination in multiple forensic media.