988 resultados para LATERAL APPROACH


Relevância:

70.00% 70.00%

Publicador:

Resumo:

AimTo describe the early healing within the void obtained after the elevation of the sinus mucosa and simultaneous implant installation without the use of any grafting material in monkeys.Material and methodsImplants were installed simultaneously with the elevation of the maxillary sinus using the lateral approach in eight monkeys without the use of grafting material. The healing after 4, 10, 20 and 30 days was evaluated in the area distal to the implants. Paraffin sections were prepared and analyzed using qualitative histological methods.ResultsThe healing process was initiated by the formation of a coagulum and followed by a provisional matrix and woven bone. Subsequently, a parallel-fiber bone replaced woven bone. The dimension of the elevated area shrank during the healing process. Sprouts of woven bone, present to a moderate extent after 4 days, were more numerous after 10 and 20 days. Newly formed bone originated from the sinus walls and septa, while there was no evidence of participation of the Schneiderian membrane in this process. After 30 days, the window access appeared to be closed by a layer of newly formed trabecular bone.ConclusionsThe coagulum that filled the void distal to the implant after simultaneous elevation of the sinus floor gave rise to newly formed bone. However, the void occupied by the coagulum shrank substantially. The Schneiderian membrane did not provide a basis for new bone formation in the early phase of healing.To cite this article:Scala A, Botticelli D, Rangel IG Jr, de Oliveira JA, Okamoto R, Lang NP. Early healing after elevation of the maxillary sinus floor applying a lateral access: a histological study in monkeys.Clin. Oral Impl. Res. 21, 2010; 1320-1326.doi: 10.1111/j.1600-0501.2009.01964.x.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To evaluate the effect of a space-maintaining device fixed to the lateral wall of the maxillary sinus after the elevation of the sinus mucosa on bone filling of the sinus cavity. Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane accomplished through lateral antrostomy in four monkeys, a titanium device was affixed to the lateral sinus wall protruding into the sinus cavity to maintain the mucosa elevated without the use of grafting material. The healing of the tissue around the implants was evaluated after 3 and 6 months. Ground sections were prepared and analyzed histologically. Results: The void under the elevated sinus membrane, originally filled with the blood clot, was reduced after 3 as well as after 6 months of healing of about 56% and 40.5%, respectively. In seven out of eight cases, the devices had perforated the sinus mucosa. The formation of mineralized bone and bone marrow amounted to about 42% and 69% after 3 and 6 months, respectively. The connective tissue represented about 53% and 23% of the newly formed tissue after 3 and 6 months, respectively. Conclusions: New bone formation was found below the devices. However, shrinkage of the newly formed tissue was observed both after 3 and 6 months of healing. Hence, the space-maintaining function of the devices used in the present study has to be questioned.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To evaluate the effect of a space-maintaining device fixed to the lateral wall of the maxillary sinus after the elevation of the sinus mucosa on bone filling of the sinus cavity. Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane accomplished through lateral antrostomy in four monkeys, a titanium device was affixed to the lateral sinus wall protruding into the sinus cavity to maintain the mucosa elevated without the use of grafting material. The healing of the tissue around the implants was evaluated after 3 and 6 months. Ground sections were prepared and analyzed histologically. Results: The void under the elevated sinus membrane, originally filled with the blood clot, was reduced after 3 as well as after 6 months of healing of about 56% and 40.5%, respectively. In seven out of eight cases, the devices had perforated the sinus mucosa. The formation of mineralized bone and bone marrow amounted to about 42% and 69% after 3 and 6 months, respectively. The connective tissue represented about 53% and 23% of the newly formed tissue after 3 and 6 months, respectively. Conclusions: New bone formation was found below the devices. However, shrinkage of the newly formed tissue was observed both after 3 and 6 months of healing. Hence, the space-maintaining function of the devices used in the present study has to be questioned.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the influence of different approach angles on the amount of nucleus pulposus removed during intervertebral disc fenestration in dogs. METHODS: Twenty cadavers of beagle dogs were randomly divided into four groups: a control group and three treatment groups in which intervertebral fenestration was performed using either a dorsal, dorsolateral or lateral approach between the 12th thoracic and second lumbar spaces. The volume of nucleus pulposus, the weight of the residual nucleus pulposus and the angle of the working sector were measured. The ratio of the residual nucleus pulposus weight to the nucleus pulposus volume was used to evaluate the efficacy of the performed fenestration. Data were analysed with Kruskal-Wallis analysis of variance between groups on ranks with correction for ties and Bonferroni correction for multiple comparisons. Correlation between ratio and working angle was calculated using a Spearman's rank test (P<0.05). RESULTS: The calculated ratio of nuclear weight to volume was significantly less in the lateral approach group than that in the other groups. The working sector was widest in the dorsolateral approach group, but this did not correlate with efficient fenestration. CLINICAL SIGNIFICANCE: Using the lateral approach for intervertebral disc fenestration may increase the efficiency of the fenestration procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Accurate estimates of the time-to-contact (TTC) of approaching objects are crucial for survival. We used an ecologically valid driving simulation to compare and contrast the neural substrates of egocentric (head-on approach) and allocentric (lateral approach) TTC tasks in a fully factorial, event-related fMRI design. Compared to colour control tasks, both egocentric and allocentric TTC tasks activated left ventral premotor cortex/frontal operculum and inferior parietal cortex, the same areas that have previously been implicated in temporal attentional orienting. Despite differences in visual and cognitive demands, both TTC and temporal orienting paradigms encourage the use of temporally predictive information to guide behaviour, suggesting these areas may form a core network for temporal prediction. We also demonstrated that the temporal derivative of the perceptual index tau (tau-dot) held predictive value for making collision judgements and varied inversely with activity in primary visual cortex (V1). Specifically, V1 activity increased with the increasing likelihood of reporting a collision, suggesting top-down attentional modulation of early visual processing areas as a function of subjective collision. Finally, egocentric viewpoints provoked a response bias for reporting collisions, rather than no-collisions, reflecting increased caution for head-on approaches. Associated increases in SMA activity suggest motor preparation mechanisms were engaged, despite the perceptual nature of the task.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les approches arthroscopiques et l’anatomie normale des articulations antébrachiocarpienne, carpienne moyenne et tarsocrurale n’ont jamais été décrites spécifiquement chez les bovins. Notre étude avait pour buts de définir les abords chirurgicaux et de décrire l’anatomie arthroscopique de ces trois articulations. Deux carpes et deux tarses issus du cadavre frais d’une vache adulte ont été injectés avec un mélange de latex, puis disséqués afin de déterminer les sites arthroscopiques d’intérêt. Par la suite, l’arthroscopie des articulations antébrachiocarpienne et carpienne moyenne (approche dorsale) et de l’articulation tarsocrurale (approches dorsale et plantaire) a été réalisée sur six cadavres frais de vaches adultes ne présentant ni boiterie ni distension articulaire avant leur euthanasie. Les approches dorsolatérale et dorsomédiale des articulations antébrachiocarpienne et carpienne moyenne ont été réalisées de part et d’autre de l’extenseur radial du carpe. Les structures observées étaient le radius distal, les os radial, intermédiaire, ulnaire, II et III fusionnés et IV du carpe, ainsi que des ligaments palmaires. Les approches dorsolatérale et dorsomédiale de l’articulation tarsocrurale ont été réalisées latéralement au long extenseur des doigts et médialement au troisième péronier respectivement. Les approches plantarolatérale et plantaromédiale ont été réalisées latéralement au fléchisseur latéral des doigts et latéralement au fléchisseur médial des doigts respectivement. Les structures observées étaient le tibia distal, les trochlées proximale et plantaire du talus, le processus coracoïde du calcanéus, l’articulation fibulo-calcanéenne et des ligaments articulaires. Quelle que soit l’articulation, l’approche latérale était préférée à l’approche médiale. L’arthroscopie du carpe et du tarse pourra être proposée dans un contexte hospitalier comme outil diagnostique, thérapeutique et pronostique des maladies articulaires bovines.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To describe the early healing processes around the implants installed after elevation of the sinus mucosa applying the lateral access technique without the use of grafting material.Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane by the lateral approach in eight monkeys, implants were installed without the use of grafting material. The healing of the tissue around the implants was evaluated after 4, 10, 20 and 30 days. Ground sections were prepared and analyzed histologically.Results: After 4 days of healing, the formation of coagulum and provisional matrix was documented within the elevated area. At 10-day interval, sprouts of woven bone were in continuity with the parent bone, and partly in contact with the implant surface at the base of the augmented area. While bone-to-implant contact increased after 20 and 30 days, the area underneath the Schneiderian membrane appeared reduced in volume and condensed toward the apex of the implants. The sinus mucosa was to some extent collapsed onto the implant surface and on the newly formed bone.Conclusions: The void initially occupied by the coagulum after sinus membrane elevation shrank substantially during the observation period. A lack of influence of the Schneiderian membrane in bone formation apical to implants was documented in the early phase of healing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we propose a new system that allows reliable acetabular cup placement when the THA is operated in lateral approach. Conceptually it combines the accuracy of computer-generated patient-specific morphology information with an easy-to-use mechanical guide, which effectively uses natural gravity as the angular reference. The former is achieved by using a statistical shape model-based 2D-3D reconstruction technique that can generate a scaled, patient-specific 3D shape model of the pelvis from a single conventional anteroposterior (AP) pelvic X-ray radiograph. The reconstructed 3D shape model facilitates a reliable and accurate co-registration of the mechanical guide with the patient’s anatomy in the operating theater. We validated the accuracy of our system by conducting experiments on placing seven cups to four pelvises with different morphologies. Taking the measurements from an image-free navigation system as the ground truth, our system showed an average accuracy of 2.1 ±0.7 o for inclination and an average accuracy of 1.2 ±1.4 o for anteversion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: In recent years, the surgical technique for open radical prostatectomy has evolved and increasing attention is paid to preserving anatomic structures and the impact on outcome and quality of life. METHODS: Technical aspects of nerve-sparing open radical retropubic prostatectomy (RRP) are described. Patient selection criteria and functional results are discussed, focusing on postoperative urinary continence. RESULTS: The video demonstrates the nerve-sparing open RRP and important steps are elucidated with schematic drawings. The value of nerve sparing, not only for preserving erectile function, but also for preserving urinary continence is discussed and results from our institution are presented. In our series, urinary incontinence was present in 1 of 71 patients (1%) with attempted bilateral nerve-sparing, 11 of 322 (3%) with attempted unilateral nerve-sparing, or 19 of 139 (14%) without attempted nerve-sparing surgery. In multiple logistic regression analysis, the only statistically significant factor influencing urinary continence after open RRP was attempted nerve sparing (odds ratio, 4.77; 95% confidence interval, 2.18-10.44; p=0.0001). CONCLUSIONS: Nerve-sparing surgery has a significant impact on erectile function and urinary continence and should be performed in all patients provided radical tumour resection is not compromised. For successful nerve preservation we advocate a lateral approach to the prostate to improve visualisation and simplify separation of the neurovascular bundles from the dorsolateral prostatic capsule. Bunching, ligating, and incising Santorini's plexus over the prostate and not over the sphincter ensures a bloodless surgical field. Mucosa-to-mucosa adaptation of the reconstructed bladder neck and the urethra is another important factor to be observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this prospective experimental cadaveric study was to develop an ultrasound-guided technique to perform an anaesthetic pudendal nerve block in male cats. Fifteen fresh cadavers were used for this trial. A detailed anatomical dissection was performed on one cat in order to scrutinise the pudendal nerve and its ramifications. In a second step, the cadavers of six cats were used to test three different ultrasonographic approaches to the pudendal nerve: the deep dorso-lateral, the superficial dorso-lateral and the median transperineal. Although none of the approaches allowed direct ultrasonographical identification of the pudendal nerve branches, the deep dorso-lateral was found to be the most advantageous one in terms of practicability and ability to identify useful and reliable landmarks. Based on these findings, the deep dorso-lateral approach was selected as technique of choice for tracer injections (0.1 ml 1% methylene blue injected bilaterally) in six cat cadavers distinct from those used for the ultrasonographical study. Anatomical dissection revealed a homogeneous spread of the tracer around the pudendal nerve sensory branches in all six cadavers. Finally, computed tomography was performed in two additional cadavers after injection of 0.3 ml/kg (0.15 ml/kg per each injection sites, left and right) contrast medium through the deep dorso-lateral approach in order to obtain a model of volume distribution applicable to local anaesthetics. Our findings in cat cadavers indicate that ultrasound-guided pudendal nerve block is feasible and could be proposed to provide peri-operative analgesia in clinical patients undergoing perineal urethrostomy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate in humans the amount of new bone after sinus floor elevation with a synthetic bone substitute material consisting of nanocrystalline hydroxyapatite embedded in a highly porous silica gel matrix. The lateral approach was applied in eight patients requiring sinus floor elevation to place dental implants. After elevation of the sinus membrane, the cavities were filled with 0.6-mm granules of nanocrystalline hydroxyapatite mixed with the patient's blood. A collagen membrane (group 1) or a platelet-rich fibrin (PRF) membrane (group 2) was placed over the bony window. After healing periods between 7 and 11 months (in one case after 24 months), 16 biopsy specimens were harvested with a trephine bur during implant bed preparation. The percentage of new bone, residual filler material, and soft tissue was determined histomorphometrically. Four specimens were excluded from the analysis because of incomplete biopsy removal. In all other specimens, new bone was observed in the augmented region. For group 1, the amount of new bone, residual graft material, and soft tissue was 28.7% ± 5.4%, 25.5% ± 7.6%, and 45.8% ± 3.2%, respectively. For group 2, the values were 28.6% ± 6.90%, 25.7% ± 8.8%, and 45.7% ± 9.3%, respectively. All differences between groups 1 and 2 were not statistically significant. The lowest and highest values of new bone were 21.2% and 34.1% for group 1 and 17.4% and 37.8% for group 2, respectively. The amount of new bone after the use of nanocrystalline hydroxyapatite for sinus floor elevation in humans is comparable to values found in the literature for other synthetic or xenogeneic bone substitute materials. There was no additional beneficial effect of the PRF membrane over the non-cross-linked collagen membrane.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: There is limited information on potential diffusion of local anaesthetic solution after various diagnostic analgesic techniques of the proximal metacarpal region. OBJECTIVE: To document potential distribution of local anaesthetic solution following 4 techniques used for diagnostic analgesia of the proximal metacarpal region. METHODS: Radiodense contrast medium was injected around the lateral palmar or medial and lateral palmar metacarpal nerves in 8 mature horses, using 4 different techniques. Radiographs were obtained 0, 10 and 20 min after injection and were analysed subjectively. A mixture of radiodense contrast medium and methylene blue was injected into 4 cadaver limbs; the location of the contrast medium and dye was determined by radiography and dissection. RESULTS: Following perineural injection of the palmar metacarpal nerves, most of the contrast medium was distributed in an elongated pattern axial to the second and fourth metacarpal bones. The carpometacarpal joint was inadvertently penetrated in 4/8 limbs after injections of the palmar metacarpal nerves from medial and lateral approaches, and in 1/8 limbs when both injections were performed from the lateral approach. Following perineural injection of the lateral palmar nerve using a lateral approach, the contrast medium was diffusely distributed in all but one limb, in which the carpal sheath was inadvertently penetrated. In 5/8 limbs, following perineural injection of the lateral palmar nerve using a medial approach, the contrast medium diffused proximally to the distal third of the antebrachium. CONCLUSIONS AND POTENTIAL RELEVANCE: Inadvertent penetration of the carpometacarpal joint is common after perineural injection of the palmar metacarpal nerves, but less so if both palmar metacarpal nerves are injected using a lateral approach. Following injection of the lateral palmar nerve using a medial approach, the entire palmar aspect of the carpus may be desensitised.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE Despite the fact that new and modern short-stems allow bone sparing and saving of soft-tissue and muscles, we still face the challenge of anatomically reconstructing the femoro-acetabular offset and leg length. Therefore a radiological and clinical analysis of a short-stem reconstruction of the femoro-acetabular offset and leg length was performed. METHODS Using an antero-lateral approach, the optimys short-stem (Mathys Ltd, Bettlach, Switzerland) was implanted in 114 consecutive patients in combination with a cementless cup (Fitmore, Zimmer, Indiana, USA; vitamys RM Pressfit, Mathys Ltd, Bettlach, Switzerland). Pre- and postoperative X-rays were done in a standardized technique. In order to better analyse and compare X-ray data a special double coordinate system was developed for measuring femoral- and acetabular offset. Harris hip score was assessed before and six weeks after surgery. Visual analogue scale (VAS) satisfaction, leg length difference and the existence of gluteal muscle insufficiency were also examined. RESULTS Postoperative femoral offset was significantly increased by a mean of 5.8 mm. At the same time cup implantation significantly decreased the acetabular offset by a mean of 3.7 mm, which resulted in an increased combined femoro-acetabular offset of 2.1 mm. Postoperatively, 81.7 % of patients presented with equal leg length. The maximum discrepancy was 10 mm. Clinically, there were no signs of gluteal insufficiency. No luxation occurred during hospitalization. The Harris hip score improved from 47.3 before to 90.1 points already at six weeks after surgery while the mean VAS satisfaction was 9.1. CONCLUSION The analysis showed that loss of femoro-acetabular offset can be reduced with an appropriate stem design. Consequently, a good reconstruction of anatomy and leg length can be achieved. In the early postoperative stage the clinical results are excellent.