971 resultados para LASER FREQUENCY MEASUREMENTS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A three-laser heterodyne system was used to measure the frequencies of twelve optically pumped laser emissions from 13CH3OH in the far-infrared (FIR) region. These emissions, ranging from 54 to 142 μm, are reported with fractional uncertainties up to ±2 × 10-7 along with their polarization relative to the CO2 pump. Using the 9P32 and 10R14 CO2 lines, complete spectroscopic assignments for two laser systems were confirmed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated the IR absorption spectrum of (CH3OH)-C-13 around the frequency of the 10R(20) CO2 laser line. We found two absorption lines which can be excited by 10R(20) and studied the FIR laser emissions excited by this pump line using a waveguide CO2 laser of 300 MHz tunability: We report two new FIR laser lines of large offset, not previously observed due to their weakness and closeness to other stronger lines. We measured the frequencies of five FIR laser lines for the first time by an accurate heterodyne technique and present the complete assignments of the IR-FIR laser systems relative to this pump line. Furthermore we present new frequency values for two FIR laser lines whose frequencies had been previously wrongly measured. Copyright (C) 1997 Elsevier B.V. Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report 18 new laser lines from (CH3OH)-C-13 generated in an optically pumped far-infrared laser; the laser lines are in the range of 54.2-420 mu m and are all characterized in wavelength, polarization relative to the pumping CO2 radiation, and pump offset relative to the CO2 center frequency, the frequencies of seven of these new lines along with 10 previously reported lines were measured by an accurate heterodyne technique, mixing them in a metal-insulator-metal (MIM) point contact diode, with another laser line of known frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the discovery of 57 new fir laser lines from (CD3OH)-C-13 molecule optically pumped by a waveguide CO2 laser of 300 MHz tunability. For all lines, precise frequency offset measurements between the CO2 line center and the center of the absorbing (CD3OH)-C-13 line were performed using the transferred Lamb-Dip technique. We have also measured directly the frequency of seven FIR laser lines by heterodyning with already known laser lines.We present a complete list of all known laser lines (134) and frequency measurements (24) for this molecule.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the frequency measurements of 18 optically pumped far-infrared (FIR) laser lines generated from CD3OH and (CH3OH)-C-13. We use the heterodyne technique of mixing FIR laser radiations and microwave radiation on a metal-insulator-metal point-contact tunnel diode to determine the FIR laser frequencies. Two FIR laser systems, consisting of CO2 waveguide pump lasers and Fabry-Perot FIR laser cavities, were used as optical sources. (C) 1997 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A unique high temporal frequency dataset from an irrigated cotton-wheat rotation was used to test the agroecosystem model DayCent to simulate daily N2O emissions from sub-tropical vertisols under different irrigation intensities. DayCent was able to simulate the effect of different irrigation intensities on N2O fluxes and yield, although it tended to overestimate seasonal fluxes during the cotton season. DayCent accurately predicted soil moisture dynamics and the timing and magnitude of high fluxes associated with fertilizer additions and irrigation events. At the daily scale we found a good correlation of predicted vs. measured N2O fluxes (r2 = 0.52), confirming that DayCent can be used to test agricultural practices for mitigating N2O emission from irrigated cropping systems. A 25 year scenario analysis indicated that N2O losses from irrigated cotton-wheat rotations on black vertisols in Australia can be substantially reduced by an optimized fertilizer and irrigation management system (i.e. frequent irrigation, avoidance of excessive fertiliser application), while sustaining maximum yield potentials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method of frequency-shifting for a diode laser is realized. Using a sample-and-hold circuit, the error signal can be held by the circuit during frequency shifting. It can avoid the restraint of locking or even lock-losing caused by the servo circuit when we input a step-up voltage into piezoelectric transition (PZT) to achieve laser frequency-shifting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Length frequency distributions of the sea bream collected during the period 1953 to 1958 have been analysed. The increase in average sizes of the sea bream with depth suggests a movement to deeper waters with increase in size. By numbers, the sea bream is more abundant between 21 and 30 fathoms than in deeper areas. The recruitment was continuous and regular. There is no sign of entry or progression of a dominant brood throughout the period under study. Length frequency distribution shows three distinct modes. The first mode occurs regularly but does not progress beyond 40cm, recruitment being balanced by natural and fishing mortality. The other two which are not regular are probably the result of fishing outside regular areas. Short sections of “growth” lines which fit into one another when extrapolated, are evident. The larger lines obtained by extrapolation are parallel to one another. These tentative "growth lines" indicate that this species which enters the fishing grounds, when 15 cm or larger in length are exploited by the trawl fishery for a period of three to four years. This species appears to be six months old when it enters the fishing grounds and increases in length by about 37.5 cm in the next 30 months. Later growth slows down. The average size of the specimens sampled continued to get smaller from 1953 till 1957. It is shown that this reduction in size is due to increased fishing effort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methyl alcohol is the most important lasing molecule in the Far-Infrared (FIR) spectral region, and the most widely used for investigation and for applications. Since the last critical review of 1984, over seventy papers have been published dealing with the FIR laser lines and the infrared spectroscopy of CH3OH. In 1984 we could list about 330 FIR laser lines, 98 of which were measured in frequency and 105 assigned. Since then more than 70 papers were published increasing the number of the known laser lines to 575 (103 measured in frequency). Also the FIR and IR spectroscopy was largely improved thanks to the analysis of high resolution FT spectra, and the number of the correctly assigned laser lines has been increased to 224. The wavenumbers of the assigned lines can now be predicted with an accuracy of about 0.001 cm-1 or better, thus approaching the accuracy of the experimental frequency measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have measured internal friction and frequency as a function of temperature in molybdenum containing oxygen and nitrogen in solid solution. These measurements were performed by a torsion pendulum operating in the temperature range of 300 K to 700 K with oscillation frequency about 1.0 Hz. The results showed the complex relaxation process identifying the stress induced ordering of oxygen and nitrogen atom around the molybdenum atoms of the metallic matrix.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the influence of thickness and aging on the intrinsic fluorescence of sealing materials and their ability to block fluorescence from the underlying surface as assessed using a laser fluorescence device. Cavities of 0.5 mm and 1 mm depth were drilled into acrylic boards which were placed over two surfaces with different fluorescence properties: a low-fluorescence surface, to assess the intrinsic fluorescence of the sealing materials, and a high-fluorescence surface, to assess the fluorescence-blocking ability of the sealing materials. Ten cavities of each depth were filled with different sealing materials: Adper Scotchbond Multi-Purpose, Adper Single Bond 2, FluroShield, Conseal f and UltraSeal XT Plus. Fluorescence was measured with a DIAGNOdent pen at five different time points: empty cavity, after polymerization, and 1 day, 1 week and 1 month after filling. The individual values after polymerization, as well as the area under the curve for the different periods were submitted to ANOVA and the Tukey test (p < 0.05). At 0.5 mm, Scotchbond, FluroShield and UltraSeal showed insignificant changes in intrinsic fluorescence with aging and lower fluorescence after polymerization than Single Bond and Conseal. At 1 mm, Scotchbond and FluroShield showed the lowest intrinsic fluorescence, but only Scotchbond showed no chagnes in fluorescence with aging. At both depths, Scotchbond blocked significantly less fluorescence. All sealing materials blocked more fluorescence when applied to a depth of 1 mm. At 0.5 mm, fissure sealants blocked more fluorescence than adhesives, and did not show significant changes with aging. Scotchbond had the least affect on the fluorescence from the underlying surface and would probably have the least affect on the monitoring of sealed dental caries by laser fluorescence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: (1) To assess spinal cord blood flow (SCBF) during surgical treatment of disk extrusion in dogs and (2) to investigate associations between SCBF, clinical signs, presurgical MRI images, and 24-hour surgical outcome. STUDY DESIGN: Cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n=12). METHODS: Diagnosis was based on clinical signs and MRI findings, and confirmed at surgery. Regional SCBF was measured intraoperatively by laser-Doppler flowmetry before, immediately after surgical spinal cord decompression, and after 15 minutes of lavaging the lesion. Care was taken to ensure a standardized surgical procedure to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found in all dogs (Wilcoxon's signed-rank test; P=.05) immediately after spinal cord decompression and after 15 minutes. Changes in SCBF were not associated with duration of clinical signs; initial or 24-hour neurologic status; or degree of spinal cord compression assessed by MRI. CONCLUSION: SCBF increases immediately after spinal cord decompression in dogs with disk herniation; however, increased SCBF was not associated with a diminished 24-hour neurologic status. CLINICAL RELEVANCE: An increase in SCBF does not appear to be either associated with the degree of spinal cord compression or of a magnitude sufficient to outweigh the benefit of surgical decompression by resulting in clinically relevant changes in 24-hour outcome.