869 resultados para Knee prosthesis replacement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared revision and mortality rates of 4668 patients undergoing primary total hip and knee replacement between 1989 and 2007 at a University Hospital in New Zealand. The mean age at the time of surgery was 69 years (16 to 100). A total of 1175 patients (25%) had died at follow-up at a mean of ten years post-operatively. The mean age of those who died within ten years of surgery was 74.4 years (29 to 97) at time of surgery. No change in comorbidity score or age of the patients receiving joint replacement was noted during the study period. No association of revision or death could be proven with higher comorbidity scoring, grade of surgeon, or patient gender. We found that patients younger than 50 years at the time of surgery have a greater chance of requiring a revision than of dying, those around 58 years of age have a 50:50 chance of needing a revision, and in those older than 62 years the prosthesis will normally outlast the patient. Patients over 77 years old have a greater than 90% chance of dying than requiring a revision whereas those around 47 years are on average twice as likely to require a revision than die. This information can be used to rationalise the need for long-term surveillance and during the informed consent process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: This study aims to address medical and non-medical direct costs and health outcomes of bilateral and unilateral total knee replacement from the patients' perspective during the first year post-surgery. Methods: Osteoarthritis patients undergoing primary unilateral total knee or bilateral total knee replacement (TKR) surgery at three Sydney hospitals were eligible. Patients completed questionnaires pre-operatively to record expenses during the previous three months and health status immediately prior to surgery. Patients then maintained detailed prospective cost diaries and completed SF-36 and WOMAC Index each three months for the first post-operative year. Results: Pre-operatively, no significant differences in health status were found between patients undergoing unilateral TKR and bilateral TKR. Both unilateral and bilateral TKR patients showed improvements in pain, stiffness and function from pre-surgery to 12 months post-surgery. Patients who had bilateral TKR spent an average of 12.3 days in acute hospital and patients who had unilateral TKR 13.6 days. Totally uncemented prostheses were used in 6% of unilateral replacements and 48% of bilateral replacements. In hospital, patients who had bilateral TKR experienced significantly more complications, mainly thromboembolic, than patients who had unilateral TKR. Regression analysis showed that for every one point increase in the pre-operative SF-36 physical score (i.e. improving physical status) out-of-pocket costs decreased by 94%. Out-of-pocket costs for female patients were 3.3 times greater than for males. Conclusion: Patients undergoing bilateral TKR and unilateral TKR had a similar length of stay in hospital and similar out-of-pocket expenditures. Bilateral replacement patients reported better physical function and general health with fewer health care visits one year post procedure. Patients requiring bilateral TKR have some additional information to aid their decision making. While their risk of peri-operative complications is higher, they have an excellent chance of good health outcomes at 12 months and are not going to be doubly 'out-of-pocket' for the experience. (C) 2004 OsteoArthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We carried out a descriptive, retrospective study with a sample side of 121 patients with Legión® prosthesis replacement in our Vírgen del Rocío hospital area, in the city of Seville, from May of 2008 until March of 2011. This study included epidemiological data as well as technical information about the process performed, including post-operative pain, mobility and functional results using a functional assessment scale and series of radiological studies. Average follow-up was 19 months, with a mean age of 71 years and 87% women. We obtained an average of 20.41º for articular balance obtained, correction of prior deformities by restoring the tibia-femoral axis to the anatomic e balance articular angle; we resolved bone loss prior to replacement and carried out an adequate balance of the inter-lineal joint. 66% of the patients continued with no post-operative pain, with the other 33% reporting slight to moderate pain. With regards to pain at the point of the stem, we have found no significant relationship with the incidence angle of the stem on the cortical or with the type of cement. We observed a 74% rate of intervention without complications, with complications being rupture of the patellar tendon in one patient, one case of peri-prosthesis fracture, two iatrogenic avulsion fractures of the anterior tibial tuberosity and seven infections (4 were diagnosed previously).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

After a total knee replacement, inadequate rehabilitation is associated with poor physical outcomes and a reduced longevity of the knee prosthesis. We have developed a low-bandwidth telemedicine system to enable rehabilitation services to be delivered directly to the home of patients in rural and remote areas. We have examined the experience of clinical physiotherapists and of 31 participants who received treatment via the system. High levels of satisfaction were reported by participants (mean responses >7 on a 10 cm visual analogue scale). The service was found to be effective, safe and easy to use, and it integrated well into current clinical practice. The study demonstrates the potential for delivering physiotherapy services via low-bandwidth Internet connections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Total knee arthroplasty (TKA) imposes many risks. TKA infection is not the most frequent complication, but is probably the most serious one. Two-step review is the procedure of choice in deep knee prosthesis infection. On the other hand, aseptic prosthesis detachment represents almost half of the primary arthroplasty review indications, Patient`s satisfaction level might diminish after reviews. Objective: The objective of this study was to compare the quality of life and final result of TKA review for septic and aseptic failures. Methods: The patients were assessed using the HSS and SF-36 scores. The patients were divided in two groups: one group submitted to two-step review (septic) and the other to one-step review (aseptic). The analysis of the data obtained shows better scores for the second group in HSS and in 06 of 08 domains of SF-36 classification. Conclusions: The on-step review of total knee arthroplasty leads to better functional outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: In total knee arthroplasty, the minimally-invasive approach has been claimed to enable earlier rehabilitation because it spares the femoral quadriceps muscle. To check the influence of preserving the extensor apparatus during surgery, the strength of knee extension and flexion muscles was evaluated in patients submitted to total knee arthroplasty with different approaches. Materials and Methods: The values of maximum torque and total work obtained by isokinetic dynamometry six months after surgery were compared for the Minimally invasive surgery group constituted of 12 individuals submitted to total knee arthroplasty by the minimally invasive surgical approach and the Control group, constituted of eight patients submitted to total knee arthroplasty by the transquadricipital approach, between January 2005 and July 2006. Results: Statistical analysis of the absolute values for maximum torque and total work adjusted for body weights did not show differences between both groups. Conclusion: There was no difference in the extension and flexion strength of the knee muscles six months after surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The usual complications of total knee arthroplasty include thrombo-embolism, infection, and loosening. We report an unusual and potentially serious complication of an intramedullary guide lodging within the femoral canal during the procedure. Considering the risk of fracture and additional exposure, the guide was not removed and was cut in situ. The rest of the operation was completed successfully and the patient made an uneventfully recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total knee arthroplasty (TKA) remains the preferred treatment for patients with invalidating osteoarthritis. It allows these patients to find once again a satisfactory quality of life. These results are reflected by the increasing number of interventions performed each year and in always younger patients. The objective of this review of the scientific literature was to determine the long-term quantitatively and qualitatively results of TKA and determine the parameters which could influence the long-term outcome. There does not seem to be any clear arguments in favor of one type of implant or surgical technique. One also notices that TKA in females and older patients seem to have longer lifespan, estimated to approximately 15 years. The most frequent complication remains aseptic loosening followed by infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years' follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years). Improvements in most gait parameters at five years' follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.