989 resultados para Kinematic Data


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: In recent years, there have been investigations concerning upper-limbs kinematics by various devices. The latest generation of smartphones often includes inertial sensors with subunits which can detect inertial kinematics. The use of smartphones is presented as a convenient and portable analysis method for studying kinematics in terms of angular mobility and linear acceleration Objective: The aim of this study was to study humerus kinematics through six physical properties that correspond to angular mobility and acceleration in the three axes of space, obtained by a smartphone. Methods: This cross-sectional study recruited healthy young adult subjects. Descriptive and anthropometric independent variables related to age, gender, weight, size, and BMI were included. Six physical properties were included corresponding to two dependent variables for each of three special axes: mobility angle (degrees) and lineal acceleration (meters/seconds2), which were obtained thought the inertial measurement sensor embedded in the iPhone4 smartphone equipped with three two elements for the detection of kinematic variables: a gyroscope and an accelerometer. Apple uses an LIS302DL accelerometer in the iPhone4. The application used to obtain kinematic data was xSensor Pro, Crossbow Technology, Inc., available at the Apple AppStore. The iPhone4 has storage capacity of 20MB. The data-sampling rate was set to 32 Hz, and the data for each analytical task was transmitted as email for analysis and postprocessing The iPhone4 was placed in the right half of the body of each subject located in the middle third of the humerus slightly posterior snugly secured by a neoprene fixation belt. Tasks were explained concisely and clearly. The beginning and the end were decided by a verbal order by the researcher. Participants were placed standing, starting from neutral position, performing the following analytical tasks: 180º right shoulder abduction (eight repetitions) and, after a break of about 3 minutes, 180º right shoulder flexion (eight repetitions). Both tasks were performed with the elbow extended, wrist in neutral position and the palmar area of the hand toward the midline at the beginning and end of the movement. Results: A total of 11 subjects (8 men, 3 woman) were measured, whose mean of age was 24.7 years (SD = 4.22 years) and their average BMI was 22.64 Kg/m2 (SD = 2.29 Kg/m2). The mean of angular mobility collected by the smartphone was bigger in pitch axis for flexion (= 157.28°, SD= 12.35°) and abduction (= 151.71°, SD= 9.70°). With regard to acceleration, the highest peak mean value was shown in the Y motion axis during flexion (= 19.5°/s2, SD = 0.8°/s2) and abduction (= 19.4°/s2, SD = 0.8°/s2). Also, descriptive graphics of analytical tasks performed were obtained. Conclusions: This study shows how humerus contributes to upper-limb motion and it identified movement patterns. Therefore, it supports smartphone as a useful device to analyze upper-limb kinematics. Thanks to this study it´s possible to develop a simple application that facilitates the evaluation of the patient.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The frequently observed lopsidedness of the distribution of stars and gas in disc galaxies is still considered as a major problem in galaxy dynamics. It is even discussed as an imprint of the formation history of discs and the evolution of baryons in dark matter haloes. Here, we analyse a selected sample of 70 galaxies from the Westerbork Hi Survey of Spiral and Irregular Galaxies. The Hi data allow us to follow the morphology and the kinematics out to very large radii. In the present paper, we present the rotation curves and study the kinematic asymmetry. We extract the rotation curves of the receding and approaching sides separately and show that the kinematic behaviour of disc galaxies can be classified into five different types: symmetric velocity fields where the rotation curves of the receding and approaching sides are almost identical; global distortions where the rotation velocities of the receding and approaching sides have an offset that is constant with radius; local distortions leading to large deviations in the inner and negligible deviations in the outer parts (and vice versa); and distortions that divide the galaxies into two kinematic systems that are visible in terms of the different behaviour of the rotation curves of the receding and approaching sides, which leads to a crossing and a change in side. The kinematic lopsidedness is measured from the maximum rotation velocities, averaged over the plateau of the rotation curves. This gives a good estimate of the global lopsidedness in the outer parts of the sample galaxies. We find that the mean value of the perturbation parameter denoting the lopsided potential as obtained from the kinematic data is 0.056. Altogether, 36% of the sample galaxies are globally lopsided, which can be interpreted as the disc responding to a halo that was distorted by a tidal encounter. In Paper II, we study the morphological lopsidedness of the same sample of galaxies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study investigated kinematic patterns in clinically normal German Shepherd dogs (GSDs) compared to those with hip dysplasia and with no clinical signs of lameness. Two groups of GSDs, including 10 clinically healthy dogs (G1) and 10 with hip dysplasia (G2), were trotted on a treadmill at a constant speed. Kinematic data were collected by a 3-camera system and analysed by a motion-analysis program. Flexion and extension joint angles and angular velocities were determined for the shoulder, elbow, carpal, hip, stifle, and tarsal joints.Within each group, the differences between the right and left limbs in all kinematic variables were not significant. Minimum angle, angular displacement and minimum angular velocity did not differ between groups. Significant differences were observed in the maximum angular velocity and maximum angle of the hip joint (dysplastic. >. healthy), and in the maximum angular velocity of the carpal joint (healthy. >. dysplastic). It was concluded that, when trotting on a treadmill, dysplastic dogs with no signs of lameness may present joint kinematic alterations in the hind as well as the forelimbs. © 2012 Elsevier Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Quantitative measures of human movement quality are important for discriminating healthy and pathological conditions and for expressing the outcomes and clinically important changes in subjects' functional state. However the most frequently used instruments for the upper extremity functional assessment are clinical scales, that previously have been standardized and validated, but have a high subjective component depending on the observer who scores the test. But they are not enough to assess motor strategies used during movements, and their use in combination with other more objective measures is necessary. The objective of the present review is to provide an overview on objective metrics found in literature with the aim of quantifying the upper extremity performance during functional tasks, regardless of the equipment or system used for registering kinematic data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is often postulated that an increased hip to shoulder differential angle (`X-Factor') during the early downswing better utilises the stretch-shorten cycle and improves golf performance. The current study aims to examine the potential relationship between the X-Factor and performance during the tee-shot. Seven golfers with handicaps between 0 and 10 strokes comprised the low-handicap group, whilst the high-handicap group consisted of eight golfers with handicaps between 11 and 20 strokes. The golfers performed 20 drives and three-dimensional kinematic data were used to quantify hip and shoulder rotation and the subsequent X-Factor. Compared with the low-handicap group, the high-handicap golfers tended to demonstrate greater hip rotation at the top of the backswing and recorded reduced maximum X-Factor values. The inconsistencies evident in the literature may suggest that a universal method of measuring rotational angles during the golf swing would be beneficial for future studies, particularly when considering potential injury.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To describe barefoot, shod and in-shoe kinematics during stance phase of walking gait in a normal arched adult population. An equal sample of males and females (n = 24) was recruited. In order to quantify the effect of footwear independent of technical design features, an ASICS shoe (Onitsuka Tiger-Mexico 66, Japan) was used in this study. Markers were applied to three conditions; barefoot, shod, and in-shoe. The calibration markers were used to define static pose. The order of testing was randomised. Participants completed five trials in each condition. Kinematic data were captured using a 12 camera VICON MX40 motion capture system at 100 Hz and processed in Visual3D. A previously developed model was used to describe joint angles [1]. A univariate two-way ANOVA was used to identify any differences between the pairs of conditions. Post-hoc Sheffé tests were used to further interrogate the data for differences. At peak hallux dorsiflexion (Figure 1), during propulsion, the metatarsophalangeal joint (MPTJ) was significantly more dorsiflexed in the barefoot condition compared to the shod condition (p = 0.004). At the same gait event, the tibiocalcaneal joint (TCJ) was significantly more plantarflexed than both the shod and in-shoe conditions (p < 0.001), and the tarsometatarsal joint (TMTJ) was significantly less dorsiflexed in the barefoot condition compared to the shod and in-shoe conditions (p < 0.001). The findings of the current study demonstrate that footwear has significant effects on sagittal plane MPTJ joint dorsiflexion at peak hallux dorsiflexion, which results in compensations at proximal foot joints.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rehabilitation programs of bone-anchorage prostheses relying either on the OPRA (Integrum, Sweden) or the ILP (Orthodynamics, Germany) fixation involve some forms of static load bearing exercises (LBE). So far, most of biomechanical studies of these static LBEs focused on the direct measurements of the actual forces and moments applied on the OPRA fixation of individuals with transfemoral amputation (TFA). To date, the proof-of-concept of an apparatus to conduct these kinetic measurements has been presented, along with some preliminary data. The understanding of the kinetic data is essential to improve rehabilitation programs as well as the design of upcoming loading frames. However, kinetic information alone is difficult to interpret without concomitant kinematic data. The purpose of this preliminary study was to introduce a qualitative analysis describing the different body postures during LBE for a group of TFAs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Agility is an essential part of many athletic activities. Currently, agility drill duration is the sole criterion used for evaluation of agility performance. The relationship between drill duration and factors such as acceleration, deceleration and change of direction, however, has not been fully explored. This paper provides a mathematical description of the relationship between velocity and radius of curvatures in an agility drill through implementation of a power law (PL). Two groups of skilled and unskilled participants performed a cyclic forward/backward shuttle agility test. Kinematic data was recorded using motion capture system at a sampling rate of 200 Hz. The logarithmic relationship between tangential velocity and radius of curvature of participant trajectories in both groups was established using the PL. The slope of the regression line was found to be 0.26 and 0.36, for the skilled and unskilled groups, respectively. The magnitudes of regression line slope for both groups were approximately 0.3 which is close to the expected 1/3 value. Results are an indication of how the PL could be implemented in an agility drill thus opening the way for establishment of a more representative measure of agility performance instead of drill duration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pentoxifylline (PF) is used to enhance motility of spermatozoa from infertile human subjects. We have previously shown that 0.45 mM PF improved capacitation of spermatozoa and fertilization of oocytes in vitro in hamsters. The present study was carried out to assess PF- induced changes in motility kinematics of hamster spermatozoa by a computer-aided sperm analyser (CASA) and determine the timing of onset of hyperactivation (HA) and acrosome reaction (AR) in PF-treated spermatozoa. Motility kinematics were analysed by CASA for 0-8 h in the absence or presence of 0.45 mM PF in Tyrode's medium supplemented with lactate, pyruvate and polyvinyl alcohol (TLP-PVA) or in TLP-PVA with bovine serum albumin (TALP-PVA). Conventional assessment was also made on the percentage of motility and quality of motility of spermatozoa; values were expressed as sperm motility index (SMI). Both in TALP-PVA and TLP-PVA, PF markedly increased SMI, especially the quality of motility (P < 0.02) by 2-3 h which was sustained up to 6 h. The motility kinematic data of PF-treated spermatozoa in TALP-PVA showed that average path velocity, curvilinear velocity and amplitude of lateral head displacement significantly (P < 0.05) increased as early as 2 h, with the expected decrease in straightness (STR) and linearity (LIN). Similar changes were also observed with PF-treated spermatozoa in TLP-PVA. Moreover, the percentage of hyperactivated spermatozoa in PF-treated samples was significantly (P < 0.001) higher than the untreated control at 2 h. To determine whether PF could induce AR, independent of bovine serum albumin, quantitative AR was assessed by observing the presence or absence of acrosomal cap on viable spermatozoa. PF significantly (P < 0.001) increased the percentage of AR as early as 2 h, reaching maximum at 4 h both in TALP-PVA (P < 0.05) and in TLP-PVA (P < 0.001). These results show that, in hamsters, PF induces early onset (by 2 h) of HA and AR and increases the proportion of spermatozoa undergoing physiological maturation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi avaliar comparativamente parâmetros biomecânicos (tanto antropométricos, quanto cinemáticos) de dados obtidos a partir do console Microsoft Kinect (2010). A avaliação destes parâmetros foi realizada para validar seu uso para obter informações complementares à Análise Ergonomica do Trabalho (AET) e em outras pesquisas, cujos objetivos envolvem o diagnóstico de uso de produtos ou ambientes de trabalho a partir da análises posturais e interações da população que o utiliza. A pesquisa com este console em particular é justificada uma vez que seu lançamento modificou o cenário da biomecânica, já que se trata de um equipamento acessível e portátil. Porém, sua precisão em relação à outros equipamentos ainda está em aberto, sendo inclusive, objeto de estudo de muitas pesquisas em andamento. Os dados obtidos por meio de sistemas de captura de movimentos tridimensionais permitem a avaliação de produtos, atividades e análises de interações homem-objeto. No campo do Design, é uma importante realização, uma vez que permite que profissionais tenham acesso à ferramenta que, anteriormente, era limitada à nichos especializados. O console foi comparado com o sistema de captura de movimentos inercial MVN Biomech (XSENS TECHNOLOGIES) e com o tradicional registro por meio de vídeo. Para obter dados do console Kinect, um software disponível no mercado foi selecionado a partir de critérios predefinidos para obter dados cinemáticos do console. Dois experimentos laboratoriais foram realizados: o primeiro, teve como objetivo obter dados operacionais dos equipamentos e suas limitações de uso; e o segundo foi realizado de forma a obter dados biomecânicos e compará-los a partir de três parâmetros estáticos e um dinâmico. Os parâmetros estáticos envolveram ângulos articulares e segmentares em posturas selecionadas e dimensões segmentares, onde a proposta foi avaliar dados antropométricos e as características do modelo biomecânico referente à manter os corpos rígidos durante a movimentação. O parâmetro dinâmico foi realizado de forma a obter dados de deslocamento global das articulações em movimentações selecionadas. Para possibilitar esta análise, uma plataforma digital foi desenvolvida, constituindo um campo neutro para o tratamento dos dados. A plataforma mantém os dados originais dos sistemas, permitindo a distinção entre os modelos biomecânicos e a retirada de dados que possam ser comparados. Os experimentos realizados permitiram avaliar a usabilidade do console, fornecendo diretrizes para seu uso. Para avaliar a utilização do console em ambientes reais de trabalho, foram realizados registros preliminares em laboratórios químicos, os quais se mostraram viáveis se as limitações, semelhantes às de sistemas baseados em tecnologia ótica, sejam consideradas. Futuras análises devem ser conduzidas para validar estatisticamente os resultados obtidos. Porém, considerando o objetivo do trabalho, pode-se concluir que o sistema avaliado é uma alternativa confiável no contexto proposto.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The critical phase, in jumping events in track and field, appears to be between touchdown and take-off. Since obvious similarities exist between the take off phase in both long jump and pole vault, numerous 3D kinematics and electromyographic studies have only looked at long jump. Currently there are few detailed kinematics electromyographic data on the pole vault take-off phase. The aim of this study was therefore to characterise kinematics and electromyographic variables during the take-off phase to provide a better understanding of this phase in pole vaulting and its role in performance outcome. Material and methods: Six pole-vaulters took part in the study. Kinematics data were captured with retro reflective markers fixed on the body. Hip, knee and ankle angle were calculated. Differential bipolar surface electrodes were placed on the following muscles of the take-off leg: tibialis anterior, lateral gastrocnemius, vastus lateralis, rectus femoris, bicep femoris and gluteus maximus. EMG activity was synchronously acquired with the kinematic data. EMG data were rectified and smoothed using a second order low pass Butterworth Bidirectional filter (resulting in a 4th order filter) with a cut-off frequency of 14 Hz. Results: Evolution of hip, knee and ankle angle show no significant differences during the last step before touchdown, the take-off phase and the beginning of fly phase. Meanwhile, strong differences in EMG signal are noted inter and intra pole vaulter. However for a same subject the EMG activities seem to converge to some phase locked point. Discussion: All pole vaulters have approximately the same visible coordination This coordination reflects a different muscular control among pole vaulters but also for a considered pole vaulter. These phase locked point could be considered as invariant of motor control i.e. a prerequisite for a normal sequence of the movement and performance realization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: A síndrome dolorosa miofascial é um dos principais problemas encontrados na prática clínica, tendo como principais características os pontos gatilho (PG), ativos ou latentes. Os PG latentes têm uma elevada prevalência na musculatura da cintura escapular, nomeadamente ao nível do trapézio superior (TS), influenciando o controlo motor do ombro. A compressão isquémica aplicada no PG do TS poderá influenciar o comportamento muscular dos sinergistas durante o movimento de abdução no plano da omoplata. Objetivos: Este estudo visa estudar a influência da compressão isquémica aplicada no PG do TS na magnitude de ativação dos músculos TS, trapézio inferior (TI), grande dentado (GD), infra-espinhoso (IE) e deltóide médio (DM), assim como a relação muscular através da razão entre o TS e os restantes músculos em análise, durante o movimento de abdução no plano da omoplata. Métodos: O presente estudo é experimental, aleatório e controlado. Foram criados dois grupos, grupo controlo (GC) (n=14) e grupo experimental (GE) (n=15), a partir de uma amostra de 67 indivíduos. No GC foi aplicado um procedimento placebo e no GE foi aplicada no PG latente do TS a técnica de compressão isquémica. Antes e após a intervenção foi recolhida a atividade eletromiográfica dos músculos em análise, assim como os dados cinemáticos, durante o movimento de elevação do ombro no plano da omoplata. Para a análise registou-se a amplitude máxima de abdução e foi analisada a atividade muscular individual dos músculos em estudo assim como a razão entre o TS e os restantes músculos. Esta análise foi realizada em intervalos de 30° até ao final do movimento. Resultados: Não se verificaram diferenças na amplitude máxima de abdução, nem entre grupos (1º momento p=0,608, t=0,816; 2º momento p=0,119; t=1,252) nem entre os dois momentos em cada grupo (GC, t=-1,119; p=0,256; GE, t=-1,604, p=0,135). Na magnitude de ativação individual de cada músculo também não se verificaram diferenças significativas com a aplicação da técnica, tendo-se verificado no DM uma tendência para o aumento da ativação aquando da intervenção, ao longo de todo o arco de movimento, em comparação com a pré-intervenção, já no GC de controlo não se verificaram alterações entre momentos. Também na análise da razão entre músculos não se verificaram diferenças entre grupos. Conclusão: A intervenção realizada não influenciou nenhum dos parâmetros em análise do complexo articular do ombro nem a amplitude de movimento de abdução.