985 resultados para Kernladungsradius, Laser Spektroskopie, Isotopieverschiebung, Halokern, Lithium


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nuclear charge radii of short-lived isotopes can be probed in a nuclear-model independent way via isotope shift measurements. For this purpose a novel technique was developed at GSI, Darmstadt. It combines two-photon laser spectroscopy in the 2s-3s electronic transition of lithium, resonance ionization, and detection via quadrupole mass spectrometry. In this way an accuracy of 5e-5 which is necessary for the extraction of nuclear charge radii, and an overall detection efficiency of 1e-4 is reached. This allowed an isotope shift measurement of Li-11 for the first time at the TRIUMF facility in Vancouver. Additionally, uncertainties in the isotope shift for all other lithium isotopes were reduced by about a factor of four compared to previous measurements at GSI. Results were combined with recent theoretical mass shift calculations in three-electron systems and root-mean-square nuclear charge radii of all lithium isotopes, particulary of the two-neutron halo nucleus Li-11, were determined. Obtained charge radii decrease continuously from Li-6 to Li-9, while a strong increase between Li-9 and Li-11 is observed. This is compared to predictions of various nuclear models and it is found that a multicluster model gives the best overall agreement. Within this model, the increase in charge radius between Li-9 and Li-11is to a large extend caused by intrinsic excitation of the Li-9-like core while the neutron-halo correlation contributes only to a small extend.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have studied the dynamics of warm dense Li with near-elastic x-ray scattering. Li foils were heated and compressed using shock waves driven by 4-ns-long laser pulses. Separate 1-ns-long laser pulses were used to generate a bright source of 2.96 keV Cl Ly-alpha photons for x-ray scattering, and the spectrum of scattered photons was recorded at a scattering angle of 120 degrees using a highly oriented pyrolytic graphite crystal operated in the von Hamos geometry. A variable delay between the heater and backlighter laser beams measured the scattering time evolution. Comparison with radiation-hydrodynamics simulations shows that the plasma is highly coupled during the first several nanoseconds, then relaxes to a moderate coupling state at later times. Near-elastic scattering amplitudes have been successfully simulated using the screened one-component plasma model. Our main finding is that the near-elastic scattering amplitudes are quite sensitive to the mean ionization state Z and by extension to the choice of ionization model in the radiation-hydrodynamics simulations used to predict plasma properties within the shocked Li.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Barium lithium fluoride nanocrystals were synthesized in cetyltrimethylammonium bromide (CTAB)/2-octanol/water microemulsion systems. The impurity peaks in XRD patterns were not determined. The result of SEM confirmed that the average sizes and shape of the BaLiF3 nanocrystals. The formation of BaLiF3 and particles size were strongly affected by water content. With increasing water content and reaction times, the size of the particle. increases. Meanwhile, the solvent was also found to play a key role in the synthesis of the BaLiF3 nanocrystals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ethanol with added water may be found during the process of assessing its physical and chemical properties. This addition can damage automotive vehicle engines and also may contribute to tax evasion. The present contribution describes a method based on a photothermal transparent transducer to determine the water content in ethanol. A chamber with a window of lithium tantalate coated with a thin layer of indium tin oxide was used, and a 1450-nm laser diode was employed as the excitation source. The results indicated a nearly linear response of the apparatus, as a function of the water content in water/ethanol solutions ranging from 0 to 100 (vol.%). The results for the dependency of the photothermal signal on the laser power and chopping frequency suggested that reliable results can be obtained using laser power and chopping rates above 100 mW and 10 Hz, respectively. The results reported here may be useful in the development of an alternative method that can provide real-time data on the water concentration in ethanol in a rapid, portable and unambiguous way, and that can be easily used in laboratory analyses or in gas stations. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An dem Schwerionenspeicherring TSR (MPI für Kernphysik, Heidelberg) wurde ein 7 Li +-Ionenstrahl geringer Dichte durch RF-Bunchen und Laserkühlung präpariert.Die Phasenraumverteilung in dem Strahl wurde durch Laser- spektroskopie an Ionen im metastabilen Zustand untersucht. Ein umlaufsynchrones, zeitaufgelöstes Meßverfahren für das Fluoreszenzlicht ermöglichte die Bestimmung der räumlichen Struktur mit dieser rein optischen Methode.Durch einen speziellen Präparationsschritt wurden die Ionen im Grundzustand aus dem Speicherring entfernt. Der sonst dominierende Heizeffekt der strahlinternen Streuung war dadurch vernachlässigbar und es konnte eine Temperatur von 160 mK erreicht werden.Der präparierte Ionenstrahl bietet besondere Eigenschaften im Hinblick auf Präzisionsexperimente, bei denen mit möglichst ungestörten Ionen gearbeitet werden soll. Es wird gezeigt, daß die Phasenraumverteilung der Ionen nicht mehr durch Ion-Ion-Wechselwirkungen bestimmt ist und daß der verbleibende Heizmechanismus durch die Streuung am Restgas erklärt werden kann.1993 wurde durch Laserspektroskopie an 7 Li + im TSR die spezielle Relativitätstheorie im Hinblick auf die relativistische Zeitdilatation experimentell getestet. In diesem Zusammenhang wird das zu erwartende Ergebnis eines Experimentes diskutiert, das, basierend auf den in dieser Arbeit vorgestellten Verfahren, einen erneuten Test der relativistischen Zeitdilatation mit verbesserter Genauigkeit durchführen könnte.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die theoretische und experimentelle Untersuchung von wasserstoffähnlichen Systemen hat in den letzten hundert Jahren immer wieder sowohl die experimentelle als auch die theoretische Physik entscheidend vorangebracht. Formulierung und Test der Quantenelektrodynamik (QED) standen und stehen in engen Zusammenhang mit der Untersuchung wasserstoffähnlicher Systeme. Gegenwärtig sind besonders wasserstoffähnliche Systeme schwerer Ionen von Interesse, um die QED in den extrem starken Feldern in Kernnähe zu testen. Laserspektroskopische Messungen der Hyperfeinstrukturaufspaltung des Grundzustandes bieten eine hohe Genauigkeit, ihre Interpretation wird jedoch durch die Unsicherheit in der Größe der Kernstruktureffekte erschwert. Beseitigt werden können diese durch die Kombination der Aufspaltung in wasserstoff- und lithiumähnlichen Ionen des gleichen Nuklids. In den letzten zwei Jahrzehnten scheiterten mehrere dadurch motivierte Versuche, den HFS-Übergang in lithiumähnlichen 209Bi80+ zu finden. Im Rahmen dieser Arbeit wurde kollineare Laserspektroskopie bei etwa 70% der Lichtgeschwindigkeit an 209Bi82+ und 209Bi80+ -Ionen im Experimentier- Speicherring an der GSI in Darmstadt durchgeführt. Dabei wurde der Übergang im lithiumähnlichen Bismut erstmals beobachtet und dessen Übergangswellenlänge zu 1554,74(74) nm bestimmt. Ein eigens für dieses Experiment optimiertes Fluoreszenz-Nachweissystem stellte dabei die entscheidende Verbesserung gegenüber den gescheiterten Vorgängerexperimenten dar. Der Wellenlängenfehler ist dominiert von der Unsicherheit der Ionengeschwindigkeit, die für die Transformation in das Ruhesystem der Ionen entscheidend ist. Für deren Bestimmung wurden drei Ansätze verfolgt: Die Geschwindigkeit wurde aus der Elektronenkühlerspannung bestimmt, aus dem Produkt von Orbitlänge und Umlauffrequenz und aus dem relativistischen Dopplereffekt unter Annahme der Korrektheit des früher bestimmten Überganges in wasserstoffähnlichen Bismut. Die Spannungskalibration des Elektronenkühlers wurde im Rahmen dieser Arbeit erstmals kritisch evaluiert und bislang unterschätzte systematische Unsicherheiten aufgezeigt, die derzeit einen aussagekräftigen QED-Test verhindern. Umgekehrt konnte unter Verwendung der QED-Berechnungen eine Ionengeschwindigkeit berechnet werden, die ein genaueres und konsistenteres Resultat für die Übergangswellenlängen beider Ionenspezies liefert. Daraus ergibt sich eine Diskrepanz zu dem früher bestimmten Wert des Überganges in wasserstoffähnlichen Bismut, die es weiter zu untersuchen gilt.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10^(−10). Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10^(−9) contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes (6,7)^Li was performed in order to determine the absolute frequency of the 2S → 3S transition. The achieved relative accuracy of 2×10^(−10) is improved by one order of magnitude compared to previous measurements. The results provide an opportunity to determine the nuclear charge radius of the stable and short-lived isotopes in a pure optical way but this requires an improvement of the theoretical calculations by two orders of magnitude. The second experiment presented here was performed at ISOLDE/CERN, where the absolute transition frequencies of the D1 and D2 lines in beryllium ions for the isotopes (7,9,10,11)^Be were measured with an accuracy of about 1 MHz. Therefore, an advanced collinear laser spectroscopy technique involving two counter-propagating frequency-stabilized laser beams with a known absolute frequency was developed. The extracted isotope shifts were combined with recent accurate mass shift calculations and the root-mean square nuclear charge radii of (7,10)^Be and the one-neutron halo nucleus 11^Be were determined. Obtained charge radii are decreasing from 7^Be to 10^Be and increasing again for 11^Be. While the monotone decrease can be explained by a nucleon clustering inside the nucleus, the pronounced increase between 10^Be and 11^Be can be interpreted as a combination of two contributions: the center-of-mass motion of the 10^Be core and a change of intrinsic structure of the core. To disentangle these two contributions, the results from nuclear reaction measurements were used and indicate that the center-of-mass motion is the dominant effect. Additionally, the splitting isotope shift, i.e. the difference in the isotope shifts between the D1 and D2 fine structure transitions, was determined. This shows a good consistency with the theoretical calculations and provides a valuable check of the beryllium experiment.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Die kollineare Laserspektroskopie hat sich in den vergangenen drei Jahrzehnten zur Bestimmung der Kernladungsradien mittelschwerer und schwerer kurzlebiger Atomkerne in ausgezeichneter Weise bewährt. Auf die Isotope sehr leichter Elemente konnte sie allerdings erst kürzlich erweitert werden. Dieser Bereich der Nuklidkarte ist von besonderem Interesse, denn die ersten ab-initio Modelle der Kernphysik, die den Aufbau eines Atomkerns basierend auf individuellen Nukleonen und realistischenWechselwirkungspotentialen beschreiben, sind gegenwärtig nur für die leichtesten Elemente anwendbar. Außerdem existiertrnin dieser Region eine besonders exotische Form von Atomkernen, die sogenanntenrnHalokerne. Die Isotopenkette der Berylliumisotope zeichnet sich durch das Auftreten des Ein-Neutronen Halokerns 11Be und des Zwei- oder Vier-Neutronen-Halos 14Be aus. Dem Isotop 12Be kommt durch seine Position zwischen diesen beiden Exoten und den im Schalenmodell erwarteten magischen Schalenabschluss N = 8 eine besondere Bedeutung zu.rnIm Rahmen dieser Arbeit wurden mehrere frequenzstabilisierte Lasersysteme für die kollineare Laserspektroskopie aufgebaut. An TRIGA-SPEC stehen nun unter anderem ein frequenzverdoppeltes Diodenlasersystem mit Trapezverstärker und frequenzkammstabilisierter Titan-Saphirlaser mit Frequenzverdopplungsstufe für die Spektroskopie an refraktären Elementen oberhalb von Molybdän zur Verfügung, die für erste Testexperimente eingesetzt wurden. Außerdem wurde die effiziente Frequenzvervierfachung eines Titan-Saphirlasers demonstriert. An ISOLDE/CERN wurde ein frequenzkammstabilisierter und ein jodstabilisierter Farbstofflaser installiert und für die Laserspektroskopie an 9,10,11,12Be eingesetzt. Durch das verbesserte Lasersystem und den Einsatz eines verzögerten Koinzidenznachweises für Photonen und Ionen gelang es die Empfindlichkeitrnder Berylliumspektroskopie um mehr als zwei Größenordnungen zu steigern und damit die früheren Messungen an 7−11Be erstmals auf das Isotop 12Be auszuweiten. Außerdem wurde die Genauigkeit der absoluten Übergangsfrequenzen und der Isotopieverschiebungen der Isotope 9,10,11Be signifikant verbessert.rnDurch den Vergleich mit Ergebnissen des Fermionic Molecular Dynamics Modells kann der Trend der Ladungsradien der leichteren Isotope durch die ausgeprägte Clusterstruktur der Berylliumkerne erklärt werden. Für 12Be wird ersichtlich, dass der Grundzustand durch eine (sd)2 Konfiguration statt der vom Schalenmodell erwarteten p2 Konfiguration dominiert wird. Dies ist ein klares Indiz für das bereits zuvor beobachtete Verschwinden des N = 8 Schalenabschlusses bei 12Be.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A laser beam at wavelength 647 nm is focused on a sample of 5 mol% MgO-doped lithium niobate crystal for domain inversion by a conventional external electric field. In this case, a reduction of 36% in the electric field required for domain nucleation (nucleation field) is observed. To the best of our knowledge, it is the longest wavelength reported for laser-induced domain inversion. This extends the spectrum of laser inducing, and the experimental results are helpful to understand the nucleation dynamics under laser illumination. The dependence of nucleation fields on intensities of laser beams is analysed in experiments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A compact continuous-wave blue laser has been demonstrated by direct frequency doubling of a laser diode with a periodically poled lithium niobate (PPLN) waveguide crystal. The optimum PPLN temperature is near 28 degreesC, and the dependence of waveguide crystals on crystal temperature is less sensitive than that of bulk crystals. A total of 14.8 mW of 488-nm laser power has been achieved. (C) 2005 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

X-ray laser fluorescence spectroscopy of the 2s-2p transition in Li-like ions is promising to become a widely applicable tool to provide information on the nuclear charge radii of stable and radioactive isotopes. For performing such experiments at the Experimental Storage Ring ESR, and the future NESR within the FAIR Project, a grazing incidence pumped (GRIP) x-ray laser (XRL) was set up at GSI Darmstadt using PHELIX (Petawatt High Energy Laser for heavy Ions eXperiments). The experiments demonstrated that lasing using the GRIP geometry could be achieved with relatively low pump energy, a prerequisite for higher repetition rate. In the first chapter the need of a plasma XRL is motivated and a short history of the plasma XRL is presented. The distinctive characteristic of the GRIP method is the controlled deposition of the pump laser energy into the desired plasma density region. While up to now the analysis performed were mostly concerned with the plasma density at the turning point of the main pump pulse, in this thesis it is demonstrated that also the energy deposition is significantly modified for the GRIP method, being sensitive in different ways to a large number of parameters. In the second chapter, the theoretical description of the plasma evolution, active medium and XRL emission properties are reviewed. In addition an innovative analysis of the laser absorption in plasma which includes an inverse Bremsstrahlung (IB) correction factor is presented. The third chapter gives an overview of the experimental set-up and diagnostics, providing an analytical formula for the average and instantaneous traveling wave speed generated with a tilted, on-axis spherical mirror, the only focusing system used up to now in GRIP XRL. The fourth chapter describes the experimental optimization and results. The emphasis is on the effect of the incidence angle of the main pump pulse on the absorption in plasma and on output and gain in different lasing lines. This is compared to the theoretical results for two different incidence angles. Significant corrections for the temperature evolution during the main pump pulse due to the incidence angle are demonstrated in comparison to a simple analytical model which does not take into account the pumping geometry. A much better agreement is reached by the model developed in this thesis. An interesting result is also the appearance of a central dip in the spatially resolved keV emission which was observed in the XRL experiments for the first time and correlates well with previous near field imaging and plasma density profile measurements. In the conclusion also an outlook to the generation of shorter wavelength XRL’s is given.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We study waveguide fabrication in lithium-niobo-phosphate glass, aiming at a practical method of single-stage fabrication of nonlinear integrated-optics devices. We observed chemical transformations or material redistribution during the course of high repetition rate femtosecond laser inscription. We believe that the laser-induced ultrafast heating and cooling followed by elements diffusion on a microscopic scale opens the way toward the engineering non-equilibrium sates of matter and thus can further enhance Refractive Index (RI) contrasts by virtue of changing glass composition in and around the fs tracks. © 2014 Optical Society of America.