899 resultados para Jump-to-contact phenomena


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The transition from tunneling to metallic contact between two surfaces does not always involve a jump, but can be smooth. We have observed that the configuration and material composition of the electrodes before contact largely determine the presence or absence of a jump. Moreover, when jumps are found preferential values of conductance have been identified. Through a combination of experiments, molecular dynamics, and first-principles transport calculations these conductance values are identified with atomic contacts of either monomers, dimers, or double-bond contacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have studied experimentally jump-to-contact (JC) and jump-out-of-contact (JOC) phenomena in gold electrodes. JC can be observed at first contact when two metals approach each other, while JOC occurs in the last contact before breaking. When the indentation depth between the electrodes is limited to a certain value of conductance, a highly reproducible behaviour in the evolution of the conductance can be obtained for hundreds of cycles of formation and rupture. Molecular dynamics simulations of this process show how the two metallic electrodes are shaped into tips of a well-defined crystallographic structure formed through a mechanical annealing mechanism. We report a detailed analysis of the atomic configurations obtained before contact and rupture of these stable structures and obtained their conductance using first-principles quantum transport calculations. These results help us understand the values of conductance obtained experimentally in the JC and JOC phenomena and improve our understanding of atomic-sized contacts and the evolution of their structural characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First-order time remaining until a moving observer will pass an environmental element is optically specified in two different ways. The specification provided by global tau (based on the pattern of change of angular bearing) requires that the element is stationary and that the direction of motion is accurately detected, whereas the specification provided by composite tau (based on the patterns of change of optical size and optical distance) does not require either of these. We obtained converging evidence,for our hypothesis. that observers are sensitive to composite tau in four experiments involving, relative judgments of, time to, passage with forced-choice methodology. Discrimination performance was enhanced in the presence of a local expansion component, while being unaffected when the detection of the direction of heading was impaired. Observers relied on the information carried in composite tau rather than on the information carried in its constituent components. Finally, performance was similar under conditions of observer motion and conditions of object motion. Because composite tau specifies first-order time remaining for a large number of situations, the different ways in which it may be detected are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate estimates of the time-to-contact (TTC) of approaching objects are crucial for survival. We used an ecologically valid driving simulation to compare and contrast the neural substrates of egocentric (head-on approach) and allocentric (lateral approach) TTC tasks in a fully factorial, event-related fMRI design. Compared to colour control tasks, both egocentric and allocentric TTC tasks activated left ventral premotor cortex/frontal operculum and inferior parietal cortex, the same areas that have previously been implicated in temporal attentional orienting. Despite differences in visual and cognitive demands, both TTC and temporal orienting paradigms encourage the use of temporally predictive information to guide behaviour, suggesting these areas may form a core network for temporal prediction. We also demonstrated that the temporal derivative of the perceptual index tau (tau-dot) held predictive value for making collision judgements and varied inversely with activity in primary visual cortex (V1). Specifically, V1 activity increased with the increasing likelihood of reporting a collision, suggesting top-down attentional modulation of early visual processing areas as a function of subjective collision. Finally, egocentric viewpoints provoked a response bias for reporting collisions, rather than no-collisions, reflecting increased caution for head-on approaches. Associated increases in SMA activity suggest motor preparation mechanisms were engaged, despite the perceptual nature of the task.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present the capability of a new network of field mill sensors to monitor the atmospheric electric field at various locations in South America; we also show some early results. The main objective of the new network is to obtain the characteristic Universal Time diurnal curve of the atmospheric electric field in fair weather, known as the Carnegie curve. The Carnegie curve is closely related to the current sources flowing in the Global Atmospheric Electric Circuit so that another goal is the study of this relationship on various time scales (transient/monthly/seasonal/annual). Also, by operating this new network, we may also study departures of the Carnegie curve from its long term average value related to various solar, geophysical and atmospheric phenomena such as the solar cycle, solar flares and energetic charged particles, galactic cosmic rays, seismic activity and specific meteorological events. We then expect to have a better understanding of the influence of these phenomena on the Global Atmospheric Electric Circuit and its time-varying behavior.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The side mounting of the night-vision sensors on some helmet-mounted systems creates a situation of hyperstereopsis in which the binocular cues available to the operator are exaggerated such that distances around the point of fixation are increased. For a moving surface approaching the observer, the increased apparent distance created by hyperstereopsis should result in greater apparent speed of approach towards the surface and so an operator will have the impression they have reached the surface before contact actually occurs. We simulated motion towards a surface with hyperstereopsis and compared judgements of time to contact with that under normal stereopsis as well as under binocular viewing without stereopsis. We simulated approach of a large, random-field textured and found that time to contact estimates were shorter under the hyperstereoscopic condition than those under normal stereo and no stereo, indicating that hyperstereopsis may cause observers to underestimate time to contact leading operators to undershoot the ground plane when landing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The experiments reported in this thesis investigated the visual information used by observers to judge the time-to-contact (TTC) of approaching objects. The results provide support for the proposition that TTC judgements are based on retinal image expansion rate and observers' prior experience with the objects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To review the effects of contact lenses on the corneal surface.

Methods: A review of the literature and in-house research of corneal staining and its various forms of presentation.

Results: Corneal staining manifests in many different forms. The severity of staining or insult of the cornea is usually determined by the extent (area of coverage), density, and depth. The cause of staining is multifactorial, and its location is often linked to the type of lens that is being worn, the solution used to clean/disinfect the lens, the state of hydration of the soft lens, and the state of the cornea that has been affected by the lens.

Conclusions: Sodium fluorescein dye effectively highlights corneal integrity changes referred to as corneal staining. This review describes the manifestations, the cause, the mechanisms, and the methods of remediation of corneal staining.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Learned vocal signals could be important in the formation of prezygotic isolation between two hybridising taxa. This study examined whether vocal variation in the parrot Platycercus elegans facilitates the separation of individuals from two subspecies, P. e. elegans (CR) and P. e. flaveolus (YR). CR and YR have very different plumage coloration, respectively deep crimson and pale yellow, but hybridise where they meet creating an intermediate population (WS). In a factorial design playback experiment, we conducted 108 playback trials on three focal populations (YR, WS, CR), in and around this area of hybridisation, to test if they respond differently to contact calls from their own or another population. We also analysed whether differences in acoustic variables of the stimulus calls predicted the response to the call. We did not find any indication that individuals from the three focal populations responded differently to calls sampled from their own or another subspecies. We did find an effect of two of the five acoustic variables that we used to describe and classify contact calls from the three source populations. Specifically, duration of the stimulus call positively affected the response from individuals from WS and negatively the response from CR, and CR responded more to stimulus calls with a lower peak frequency. Overall, we found no indication that acoustic variation in contact calls on a subspecies level is involved in maintaining plumage colour differences between P. e. elegans and P. e. flaveolus subspecies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Poison centres offer rapid and comprehensive support for emergency physicians managing poisoned patients. This study investigates institutional, case-specific and poisoning-specific factors which influence the decision of emergency physicians to contact a poison centre. METHODS Retrospective, consecutive review of all poisoning-related admissions to the emergency departments (EDs) of a primary care hospital and a university hospital-based tertiary referral centre during 2007. Corresponding poison centre consultations were extracted from the poison centre database. Data were matched and analysed by logistic regression and generalised linear mixed models. RESULTS 545 poisonings were treated in the participating EDs (350 (64.2%) in the tertiary care centre, 195 (35.8%) in the primary care hospital). The poison centre was consulted in 62 (11.4%) cases (38 (61.3%) by the tertiary care centre and 24 (38.7%) by the primary care hospital). Factors significantly associated with poison centre consultation included gender (female vs male) (OR 2.99; 95% CI 1.69 to 5.29; p<0.001), number of ingested substances (>1 vs 1) (OR 2.84; 95% CI 1.65 to 4.9; p<0.001) and situation (accidental vs intentional) (OR 2.76; 95% CI 1.05 to 7.25; p=0.039). In contrast, age, medical history and hospital size did not influence poison centre consultation. Poison centre consultation was significantly higher during the week, and significantly less during night shifts. The poison centre was consulted significantly more when patients were admitted to intensive care units (OR 5.81; 95% CI 3.25 to 10.37; p<0.001). Asymptomatic and severe versus mild cases were associated with more frequent consultation (OR 4.48; 95% CI 1.78 to 11.26; p=0.001 and OR 2.76; 95% CI 1.42 to 5.38; p=0.003). CONCLUSIONS We found low rates of poison centre consultation by emergency physicians. It appears that intensive care unit admission and other factors reflecting either complexity or uncertainty of the clinical situation are the strongest predictors for poison centre consultation. Hospital size did not influence referral behaviour.