929 resultados para Jamin shearing interferometer
Resumo:
The frame of a laser diode transmitter for intersatellite communication is concisely introduced. A simple, novel and visual method for measuring the diffraction-limited wavefront of the transmitter by a Jamin double-shearing interferometer is proposed. To verify the validity of the measurement, the far-field divergence of beam is additionally rigorously analysed in terms of the Fraunhofer diffraction. The measurement, the necessary analyses and discussion are given in detail. By directly measuring the fringe widths and quantitatively interpreting the interference fringes, the minimum detectable wavefront height (DWH) of the wavefront is only 0.2 gimel (the distance between the perfect plane wavefront and the actual wavefront at the transmitting aperture) and the corresponding divergence is only 65.84 mu rad. This indicates that the wavefront approaches the diffraction-limited condition. The results show that this interferometer is a powerful tool for testing the semiconductor laser beam's wavefront, especially the diffraction-limited wavefront.
Resumo:
We present a novel phase-shifting vectorial-shearing interferometer with a wedge plate phase-shifter. The interferometer is based on a modified Mach-Zehnder configuration; the common-path nature makes it capable of testing the wavefront of a short coherence-length light source, such as a laser diode. Vectorial shear (shearing in the x and y directions simultaneously) in an arbitrary direction is introduced by inserting two wedge plates orthogonally in two arms, respectively. One of the wedge plates is split into two parts (parallel part and wedge part); phase shift is produced by moving the wedge part in contact along the parallel part. The moving distance for a 2 pi phase shift is a few millimetres in specific conditions. The wedge plate phase-shifter increases the moving distance for phase shift and makes the control of phase shift relatively easy. We also discuss the lateral shear error and phase shift errors induced by wedge plates. The lateral shear error is small enough to be ignored; the phase shift error is determined mainly by the wedge angle error. Lastly, we give the experimental results of phase-shifting interference fringes in vectorial shear mode.
Resumo:
In order to measure the diffraction-limit wavefront, we present three types of common-path double-shearing interferometers based on the theory of double shearing. Two pairs of half-aperture or whole-aperture wedge plates are used to introduce opposite tilt to realize the double-shearing function. By comparing the fringe widths in two fields, the marginal wavefront aberration can be obtained. In the paper, we give three different configurations: half-aperture configuration, whole-field configuration and double-interferometer configuration. The half-aperture configuration has the features of high sensitivity, stabilization and easy alignment. For the whole-field configuration, the interference fringes are displayed in two whole fields. Consequently, the divergent or convergent characteristic and aberration types of a wavefront can be identified visually. The whole-field configuration can be changed to the double-interferometer configuration for continuous test. Both small and large wavefront aberrations can be measured by the double-interferometer configuration. The minimum detectable wavefront aberration (W-0)(min) comes to 0.03 lambda. Lastly, we present the experimental results for the three types of double-shearing interferometers.
Resumo:
在星间半导体激光通信系统中,如何检测发射光束波面的质量是个较难处理的问题,为了较好地解决这一问题,在简单介绍白光横向双剪切干涉仪的基础上,报道了用此干涉仪对近衍射极限半导体激光光束波面的检测,在此基础上推导出计算远场发散度的公式。实验测得近场光束的波高差为0.2A,通过夫朗和费衍射求得光束的发散度仅为64.8μrad,这表明光束接近光学衍射极限。同时,表明双剪切干涉仪灵敏度高、实用性好。
Resumo:
A new type of wave-front analysis method for the collimation testing of laser beams is proposed. A concept of wave-front height is defined, and, on this basis, the wave-front analysis method of circular aperture sampling is introduced. The wave-front height of the tested noncollimated wave can be estimated from the distance between two identical fiducial diffraction planes of the sampled wave, and then the divergence is determined. The design is detailed, and the experiment is demonstrated. The principle and experiment results of the method are presented. Owing to the simplicity of the method and its low cost, it is a promising method for checking the collimation of a laser beam with a large divergence. © 2005 Optical Society of America.
Resumo:
为了实现对激光波面的等光程测试,设计了一个新颖的相移矢量剪切干涉仪。该干涉仪以马赫一曾德尔结构为基础,为等光程干涉仪。通过在相干的两路光束中分别插入楔角方向正交放置的楔板实现矢量剪切;其中一块楔板分成两块(平板部分和楔板部分),楔板部分沿平板部分的表面移动,通过改变光程差来实现相移,2π相移所需的移动距离为几毫米的量级,该相移方法在相移精度控制上比较简单。文中还对楔板引入的横向剪切误差和相移误差进行了分析,最后给出了实验所得的一组相移干涉图。
Resumo:
在一种已有的角位移干涉测量技术的基础上,提出一种改进的角位移测量方法。通过选择合适的初始入射角,使从平板前后表面反射的两光束实现剪切干涉。采用一维位置探测器测量光束经透镜会聚后在探测器光敏面上的光点偏移量。根据干涉信号的相位和光点偏移量可以计算出被测物体的角位移。在该测量方案中,引入的一平面反射镜与被测物体的反射面形成光程差放大系统,提高了角位移测量灵敏度。分析了初始入射角对剪切比的影响,并讨论了基于该方案的角位移测量精度。实验结果表明,基于该技术的角位移重复测量精度达到10-8 rad数量级。
Resumo:
高重复频率热容主振荡功率放大器(MOPA)激光系统的工作过程一般只持续几秒至几十秒,在此过程中系统输出光束的波前畸变是动态变化的。采用环路径向剪切干涉(CRWSI)技术对高重复频率热容MOPA系统波前畸变的变化过程进行检测,并对系统的总体结构进行了设计。搭建了一个简化的实验系统,采用平凹透镜来代替光放大器产生波前畸变,并由此对环路径向剪切干涉仪的测量精度进行了验证。结果表明,实验测量结果与理论计算值之间的峰值误差为7.8%(0.02λ)。
Resumo:
A novel type of moving-corner-cube-pair interferometer is presented, and its principle and properties are studied. It consists of two moving corner cubes fixed together back to back as a single moving part (the moving-corner-cube-pair), four fixed plane mirrors and one beamsplitter. The optical path difference (OPD) is created by the straight reciprocating motion of the moving-corner-cube-pair, and the OPD value is eight times the physical shift value of the moving-corner-cube-pair. This novel type of interferometer has no tilt and shearing problems. It is almost ideal for the very-high-resolution infrared spectrometers.
Resumo:
Interferometry is a sensitive technique for recording tear film surface irregularities in a noninvasive manner. At the same time, the technique is hindered by natural eye movements resulting in measurement noise. Estimating tear film surface quality from interferograms can be reduced to a spatial-average-localized weighted estimate of the first harmonic of the interference fringes. However, previously reported estimation techniques proved to perform poorly in cases where the pattern fringes were significantly disturbed. This can occur in cases of measuring tear film surface quality on a contact lens on the eye or in a dry eye. We present a new estimation technique for extracting the first harmonic from the interference fringes that combines the traditional spectral estimation techniques with morphological image processing techniques. The proposed technique proves to be more robust to changes in interference fringes caused by natural eye movements and the degree of dryness of the contact lens and corneal surfaces than its predecessors, resulting in tear film surface quality estimates that are less noisy
Resumo:
There are several noninvasive techniques for assessing the kinetics of tear film, but no comparative studies have been conducted to evaluate their efficacies. Our aim is to test and compare techniques based on high-speed videokeratoscopy (HSV), dynamic wavefront sensing (DWS), and lateral shearing interferometry (LSI). Algorithms are developed to estimate the tear film build-up time TBLD, and the average tear film surface quality in the stable phase of the interblink interval TFSQAv. Moderate but significant correlations are found between TBLD measured with LSI and DWS based on vertical coma (Pearson's r2=0.34, p<0.01) and higher order rms (r2=0.31, p<0.01), as well as between TFSQAv measured with LSI and HSV (r2=0.35, p<0.01), and between LSI and DWS based on the rms fit error (r2=0.40, p<0.01). No significant correlation is found between HSV and DWS. All three techniques estimate tear film build-up time to be below 2.5 sec, and they achieve a remarkably close median value of 0.7 sec. HSV appears to be the most precise method for measuring tear film surface quality. LSI appears to be the most sensitive method for analyzing tear film build-up.
Resumo:
Purpose: To date, there have been no measuring techniques available that could clearly identify all phases of tear film surface kinetics in one interblink interval. ----- ----- Methods: Using a series of cases, we show that lateral shearing interferometry equipped with a set of robust parameter estimation techniques is able to characterize up to five different phases of tear film surface kinetics that include: (i) initial fast tear film build-up phase, (ii) further slower tear film build-up phase, (iii) tear film stability, (iv) tear film thinning, and (v), after a detected break-up, subsequent tear film deterioration. ----- ----- Results: Several representative examples are given for estimating tear film surface kinetics in measurements in which the subjects were asked to blink and keep their eyes open as long as they could. ----- ----- Conclusions: Lateral shearing interferometry is a noninvasive technique that provides means for temporal characterization of tear film surface kinetics and the opportunity for the analysis of the two-step tear film build-up process.