990 resultados para Isolated Orbital Floor Blow-out Fractures
Resumo:
Background: This is the first report of involvement of Australian and New Zealand oral and maxillofacial surgeons in the management of isolated orbital floor blow-out fractures and was conducted to obtain comparisons with the results from a recent similar survey of British oral and maxillofacial surgeons. Methods: A questionnaire survey was sent to all 113 practising members of the Australian and New Zealand Association of Oral and Maxillofacial Surgeons in April 2002 with a second mailout 1 month later. Results: Sixty-nine per cent of the respondents were referred isolated orbital floor blow-out fractures for manage-ment, and just over half of these respondents estimated that 50% or more of the cases went to surgery. The materials most commonly used in orbital floor reconstruction were resorbable membrane for small defects and autologous bone for large defects. Conclusion: As in Britain, management of isolated orbital floor blow-out fractures comprises part of the surgical spectrum for many oral and maxillofacial surgeons in Australia and New Zealand. The management protocol was observed to be very similar between the two groups.
Resumo:
To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction.
Resumo:
The aim of this study was to evaluate the difference between the effects of a 5-day and a 1-day course of antibiotics on the incidence of postoperative infection after displaced fractures of the orbit. A total of 62 patients with orbital blow-out fractures were randomly assigned to two groups, both of which were given amoxicillin/clavulanic acid 1.2g intravenously every 8h from the time of admission to 24h postoperatively. The 5-day group were then given amoxicillin/clavulanic acid 625mg orally every 8h for 4 further days. The 1-day group were given placebo orally at the same time intervals. Follow up appointments were 1, 2, 4, 6, and 12 weeks, and 6 months, postoperatively. An infection in the orbital region was the primary end point. Sixty of the 62 patients completed the study. Two of the 29 patients in the 5-day group (6.8%) and 1/31 patients in the 1-day group (3.2%) developed local infections. In the 5-day group 1 patient developed diarrhoea. In the 1-day group 1 patient developed a rash on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. We conclude that in displaced orbital fractures a postoperative 1-day course of antibiotics is as effective in preventing infective complications as a 5-day regimen.
Resumo:
Background: An experimental study was done to assess the ability of the vegetal polymer miniplates and screws to repair defects of the orbital floor.Methods: An artificial standard-sized defect was created in the bony floor of right orbit of 45 albino rabbits. The animals were divided into three experimental groups: control group (G1) involving animals with orbital floor defect and no treatment; titanium group (G2) containing animals with orbital floor defect repaired by titanium miniplates and screws; vegetal polymer group (G3) composed of animals with similar orbital floor defects repaired by vegetal polymer miniplates and screws. Throughout the course of the experiment, the animals were clinically evaluated. At 15, 30 and 60 days after surgery, the animals were killed. They were X-rayed immediately after the floor defect and at the moment of sacrifice. Histological and morphometric evaluation of inflammatory reaction and bone healing was done. Data were statistically evaluated.Results: No implants were extruded. Bone consolidation was similar in G2 and G3 and better than in G1 group animals. Inflammatory reaction was most pronounced in animals of G3 15 days after surgery, and it subsided over time.Conclusion: Vegetal polymer miniplates and screws induces small inflammatory reaction and had the ability to stimulate bone growth with good integration in the orbital floor defect allowing to consider the vegetal polymer adequate option to treat orbital floor defects. Future studies involving long-term follow-up and biomechanical tests to evaluate material resistance to traction are needed.
Resumo:
PURPOSE: To compare the effect of intravitreal and orbital floor triamcinolone acetonide (TA) on macular edema, visual outcome, and course of postoperative inflammation after cataract surgery in uveitis patients. DESIGN: Prospective, randomized clinical trial. METHODS: Monocenter study (40 patients) with chronic endogenous uveitis who underwent phacoemulsification with intraocular lens implantation with either 4 mg intravitreal TA (n = 20) or 40 mg orbital floor TA (n = 20). The primary outcome was influence on cystoid macular edema (CME). Secondary outcome measures were best-corrected visual acuity (BCVA), anterior chamber cell grade, laser flare photometry, giant cell deposition, posterior capsule opacification (PCO), and intraocular pressure. RESULTS: Mean central foveal thickness decreased in the intravitreal TA group and increased in the orbital floor TA group (P < .001 at one and three months). CME improved in 50% of patients after intravitreal TA, whereas it was unchanged after orbital floor TA (difference between the groups at three months, P = .049). Mean BCVA (logarithm of the minimal angle of resolution) improved postoperatively (P < .001) from 0.76 and 0.74 to 0.22 and 0.23 in the intravitreal TA and orbital floor TA group, respectively. Anterior chamber cell count at one month was lower in the intravitreal TA than in the orbital floor TA group (P = .02). Laser flare photometry values and giant cell numbers were slightly higher after orbital floor TA than after intravitreal TA. The groups did not differ with respect to PCO rate and ocular hypertension. CONCLUSIONS: The CME improvement and anti-inflammatory effect after intravitreal TA was better than after orbital floor TA injection in cataract surgery in uveitis patients.
Resumo:
Mode of access: Internet.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
Objective: The objective of the study was to compare the functional and aesthetic results of fractured orbital wall reconstruction with an auricular cartilage graft or absorbable polyacid copolymer. Materials and Methods: Twenty patients with blow-out orbital fracture/orbital floor associated or not with the medial wall were assessed by the same craniofacial surgical group. All were evaluated preoperatively and postoperatively by an ophthalmologist for diplopia, enophthalmos, exophthalmos, sensitivity, ophthalmic reflexes, intraocular pressure, and visual field. The patients were subjected to a preoperative facial multislice computed tomographic scan, repeated 6 months after surgery. Eight patients underwent reconstruction with an auricular cartilage graft, and 12 patients, with blade absorbable polyacid copolymer. Subtarsal access was used for all patients. Results: Two patients showed temporary ectropion, 1 in each group. All patients presented satisfactory ocular function, and all tests revealed good orbital delineation, orbital symmetry, periorbital sinus individualization, and reduction of blow-out. Conclusions: The blow-out orbital wall reconstruction can be performed with the use of an auricular cartilage or with a blade absorbable copolymer without differences regarding functional or aesthetic complications and sequelae.
Resumo:
Fractures or the medial wall of the orbit are uncommon and clinical signs are often discreet. This report was focused on isolated fractures of the medial wall of the orbit. Blow-out trauma is usually the cause. In these cases the clinical signs ranged from simple ecchymosis to blindness by haematoma of the orbital cone. Computed tomography is a major tool for diagnosis and making therapeutic indications for these fractures. Treatment depends on the oculomotor involvements as measured by forced duction tests.
Resumo:
Background: Management of orbitozygomatic fractures forms part of the scope of practice of many oral and maxillofacial Surgeons. As aspects of management vary among surgeons who treat such injuries, this confidential study was undertaken to examine some of the protocols of Australian and New Zealand oral and maxillofacial surgeons. Results: Eighty-one per cent of the respondents treated orbitozygomatic fractures and on average. each treated approximately 24 cases per year. Also, about one in five cases required orbital floor exploration. Further, the preferred imaging baseline was computed tomography plus plain X-rays. while the preferred implant materials for orbital floor reconstruction were autologous bone and resorbable membrane. The incidence of postoperative retrobulbar haemorrhage was estimated at approximately 1:1000. Conclusion: Most oral and maxillofacial surgeons treat orbitozygomatic injuries as part of their surgical scope.