992 resultados para Ise, Rosa Christina Haag, 1856-


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An account of the lives of the author's parents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hillyard et al.'s Beyond Criminology: Taking Crime Seriously is an innovative collection that attempts to take criminology beyond state definitions of crime to discourses involving harm, or what the editors refer to as ‘zemiology’, or what could be called ‘social harm theory’. The central theme of the book is that ‘it makes no sense to separate out harms, which can be defined as criminal, from all other types of harm’ (p. 2). At long last, ‘harm’ is discussed with the theoretical and practical integrity it deserves as an academic and intellectual narrative. For too long it has been ignored or omitted from the criminological lexicon. This book ensures that it captures centre stage within analyses that refocus the agenda to deleterious acts not always covered by the state legislature...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Examining the late style of a writer is like skirting around quicksand. End-of-career reflection can subvert long standing critical accounts; revisionist publishing histories or newly minted archival work can do likewise. And, as Nancy J. Troy suggests, an artist’s last thoughts are rarely planned as such (15). In the case of Christina Stead any consideration of late style is made more difficult because, chronologically speaking, her ‘late’ works were written some 20 years before her death in 1983. Thus chronology can be deceptive, as Nicholas Delbanco points out in Lastingness: The Art of Old Age. Stead’s last novel, I’m Dying Laughing The Humourist, was completed, at least in rough draft form in 1966, when Stead was 64, but friends and readers suggested many changes. The book was published posthumously in 1986. Stead’s work is receiving increasing critical attention so a discussion of her ‘late style’ is important, particularly given that her fiction seems to refuse so many attempts at category-making. This perspective reveals two interesting aspects of her late work: first her consistent engagement with the problems of age for women, and in particular women writers, and second, the consequence of a life-long attention to the representation of dialogic sound in her novels, a preoccupation that results in what can be termed an aural signature. My discussion refers to Edward Said’s and Nicholas Delbanco’s ideas about late style by way of a focus on selective biographical issues and Stead’s engagement with radical politics before moving to an examination of what can be called an aural signature in several novels. Her fiction demonstrates one of the agreed markers of late style: she was constantly looking forward and looking back through innovation in form and content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To estimate refractive indices used with the Lenstar biometer. Methods: Axial lengths of model eyes were determined using an IOLMaster biometer and a Lenstar; comparing these lengths gave an overall eye index for the Lenstar. Using the Lenstar Graphical User interface, we determined that boundaries between media could be manipulated so that there were opposite changes in optical pathlength on either side of the boundary and specified changes in distances determined the ratios of media indices. These ratios were combined with the overall eye index to estimate indices. Results: The IOLMaster and Lenstar produced axial length estimates to within ±0.01 mm. Estimations of group refractive indices were 1.340, 1.341, 1.415 and 1.354 for cornea, aqueous, lens and overall eye, respectively. The aqueous and lens indices, but not those for the cornea, are similar to schematic eye indices and reasonable lens indices. Conclusion: The Lenstar appears to use different refractive indices for different ocular media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: