948 resultados para Irregular corneas
Resumo:
PURPOSE: To evaluate in a pilot study the visual, refractive, corneal topographic, and aberrometric changes after wavefront-guided LASIK or photorefractive keratectomy (PRK) using a high-resolution aberrometer to calculate the treatment for aberrated eyes. METHODS: Twenty aberrated eyes of 18 patients undergoing wavefront-guided LASIK or PRK using the VISX STARS4IR excimer laser and the iDesign aberrometer (Abbott Medical Optics, Inc., Santa Ana, CA) were enrolled in this prospective study. Three groups were differentiated: keratoconus post-CXL group including 11 keratoconic eyes (10 patients), post-LASIK group including 5 eyes (5 patients) with previous decentered LASIK treatments, and post-RK group including 4 eyes (3 patients) with previous radial keratotomy. Visual, refractive, contrast sensitivity, corneal topographic, and ocular aberrometric changes were evaluated during a 6-month follow-up. RESULTS: An improvement in uncorrected (UDVA) and corrected visual acuity (CDVA) associated with a reduction in the spherical equivalent was observed in the three groups, but was only statistically significant in the keratoconus post-CXL and post-LASIK groups (P ≤ .04). All eyes gained one or more lines of CDVA after surgery. Improvements in contrast sensitivity were observed in the three groups, but they were only statistically significant in the keratoconus post-CXL and post-LASIK groups (P ≤ .04). Regarding aberrations, a reduction was observed in trefoil aberrations in the keratoconus post-CXL group (P = .05) and significant reductions in higher-order and primary coma aberrations in the post-LASIK group (P = .04). CONCLUSIONS: Wavefront-guided laser enhancements using the evaluated platform seem to be safe and effective to restore the visual function in aberrated eyes.
Resumo:
PURPOSE: To compare the performance of dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in measuring intraocular pressure in eyes with irregular corneas. METHODS: GAT and DCT measures were taken in 30 keratoconus and 29 postkeratoplasty eyes of 35 patients after pachymetry and corneal topography. Regression and correlation analyses were performed between both tonometry methods and between tonometry methods and corneal parameters. Bland-Altman plots were constructed. RESULTS: DCT values were significantly higher than GAT values in both study groups: +4.1 +/- 2.3 mm Hg (mean +/- SD) in keratoconus and +3.1 +/- 2.5 mm Hg after keratoplasty. In contrast to DCT, GAT values were significantly higher in postkeratoplasty eyes than in keratoconus. The correlation between the 2 tonometry methods was moderate in keratoconus (Kendall correlation coefficient, tau = 0.34) as well in postkeratoplasty eyes (tau = 0.66). The +/-1.96 SD span of the DCT-GAT differences showed a considerable range: -0.42 to +8.70 mm Hg in keratoconus and -1.87 to +7.98 mm Hg in postkeratoplasty eyes. In the keratoconus group, neither DCT nor GAT correlated significantly with any of the corneal parameters. In the postkeratoplasty group, both DCT and GAT measures showed a moderate positive correlation with corneal steepness, but only DCT had a significant negative correlation with the central corneal thickness (tau = -0.33). CONCLUSIONS: DCT measured significantly higher intraocular pressures than GAT in keratoconus and postkeratoplasty eyes. DCT and GAT measures varied considerably, and DCT was not less dependent on biomechanical properties of irregular corneas than GAT.
Resumo:
I was recently part of a small committee looking at higher qualifications in contact lens practice and the discussion turned to future technologies. There was mention of different materials and different applications of contact lenses. Drug delivery with contact lenses was discussed as this has been talked about in the literature for a while. The first paper I could find that talked about using contact lenses for drug delivery dates back over 40 years. There was a review paper in CLAE in 2008 that looked specifically at this too [1]. However, where are these products? Why are we not seeing them in the market place? Maybe the technology is not quite there yet, or maybe patents are prohibiting usage or maybe the market is not big enough to develop such products? We do have lenses on the market with slow release of lubricating agents but not therapeutic agents used for ocular or systemic conditions. Contact lenses with pathogen detectors may be part of our contact lens armoury of the future and again we can already see papers in the literature that have trialled this technology for glucose monitoring in diabetics or lactate concentration in the tear film. Future contact lenses may incorporate better optics based on aberration control and we see this starting to emerge with aspheric designs designed to minimise spherical aberration. Irregular corneas can be fitted with topography based designs and again this technology exists and is being used by some manufacturers in their designs already. Moreover, the topography based fitting of irregular corneas is certainly something we see a lot of today and CLAE has seen many articles related to this over the last decade or so. What about further into the future? Well one interesting area must the 3-dimensional contact lenses, or contact lenses with electronic devices built in that simulate a display screen. A little like the virtual display spectacles that are already sold by electronics companies. It does not take much of a stretch of the imagination to see a large electronic company taking this technology on and making it viable. Will we see people on the train watching movies on these electronic virtual reality contact lenses? I think we will, but when is harder to know.
Resumo:
PURPOSE: This study aimed to highlight structural corneal changes in a model of type 2 diabetes, using in vivo corneal confocal microscopy (CCM). The abnormalities were also characterized by transmission electron microscopy (TEM) and second harmonic generation (SHG) microscopy in rat and human corneas. METHODS: Goto-Kakizaki (GK) rats were observed at age 12 weeks (n = 3) and 1 year (n = 6), and compared to age-matched controls. After in vivo CCM examination, TEM and SHG microscopy were used to characterize the ultrastructure and the three-dimensional organization of the abnormalities. Human corneas from diabetic (n = 3) and nondiabetic (n = 3) patients were also included in the study. RESULTS: In the basal epithelium of GK rats, CCM revealed focal hyper-reflective areas, and histology showed proliferative cells with irregular basement membrane. In the anterior stroma, extracellular matrix modifications were detected by CCM and confirmed in histology. In the Descemet's membrane periphery of all the diabetic corneas, hyper-reflective deposits were highlighted using CCM and characterized as long-spacing collagen fibrils by TEM. SHG microscopy revealed these deposits with high contrast, allowing specific detection in diabetic human and rat corneas without preparation and characterization of their three-dimensional organization. CONCLUSION: Pathologic findings were observed early in the development of diabetes in GK rats. Similar abnormalities have been found in corneas from diabetic patients. TRANSLATIONAL RELEVANCE: This multidisciplinary study highlights diabetes-induced corneal abnormalities in an animal model, but also in diabetic donors. This could constitute a potential early marker for diagnosis of hyperglycemia-induced tissue changes.
Resumo:
PURPOSE: To evaluate the corneal vascularization (CV) and the clinical aspects induced by interlamellar graft with native (NCM) and anionic (ACM) collagen membranes in rabbits corneas. METHODS: An interlamellar graft with a 0.25 x 0.25 cm NCM (group 1) or ACM (group 2) fragment was performed in the right eye (treated eye). In the left eye, an estromal tunnel was done (control eye). Sixteen rabbits were used, and they were subdivided into two experimental groups of eight animals each. The clinical evaluation was performed at the 1st, 3rd, 7th, 15th and 30th postoperative days. Corneal vascularization analysis was performed after 30 days by the Images Analizator System Leica Qwin-550®. RESULTS: After 7 days, corneal vascularization was observed at about 2.25 ± 0.71 mm (NCM) and at about 1.0 ± 1.69 mm (ACM), respectively, from the limbus in direction to the central cornea. After 15 days, CV increased in both groups (5.25 ± 1.03 mm - NCM; 2.0 ± 2.39 mm - ACM) and then progressively decreased until day 30 (2.25 ± 2.10 mm - NCM; 0.75 ± 2.12 mm - ACM). The statistical analysis indicated that the averages of the distances from the limb vessels to the grafts observed after 7 and 15 days had not differed statistically (p=0.17), and after 15 and 30 postoperative days had a tendency to differ statistically (p=0.09). The control eyes did not present any changes. CONCLUSION: The interlamellar graft with native and anionic collagen membranes induced corneal vascularization when applied to rabbit corneas, but anionic collagen membrane induced a smaller corneal vascularization when compared to native collagen membrane. Although further studies are required, the results found in this study demonstrated the usefulness of interlamellar graft with native and anionic collagen membranes in keratoplasties. These membranes consists in one more graft option for the surgical treatment of corneal repair in rabbits and others animals, when other forms of medical and surgical treatment are not effective.
Resumo:
As technology improves human vision, some procedures currently performed may be causing a decrease of the natural UV protection of the cornea. A portable dual beam system prototype was assembled for physicians for clinical studies of these effects on the corneas endowing two types of 300-400 nm evaluations: 1, regularly donated corneas and 2, simulating refractive keratectomy by corneal lamellae removal. The system performs 500 measurements/s, providing +/- 0.25% precision for the transmittance. The measurements performed on the prototype are 95% in agreement with Cary 17 and HR4000CG-UV-NIR Ocean Optics spectrophotometers. Preliminary studies on cadaveric corneas demonstrate that, as the stromal layer is reduced (similar to 150 mu m depth), there is significant loss-an average of 7.1%.-of the cornea's natural UV protection. The prototype is being tested in an eye bank for routine evaluation of donor corneas. (C) 2010 Optical Society of America
Resumo:
This work deals with the problem of minimizing the waste of space that occurs on a rotational placement of a set of irregular two dimensional polygons inside a two dimensional container. This problem is approached with an heuristic based on simulated annealing. Traditional 14 external penalization"" techniques are avoided through the application of the no-fit polygon, that determinates the collision free area for each polygon before its placement. The simulated annealing controls: the rotation applied, the placement and the sequence of placement of the polygons. For each non placed polygon, a limited depth binary search is performed to find a scale factor that when applied to the polygon, would allow it to be fitted in the container. It is proposed a crystallization heuristic, in order to increase the number of accepted solutions. The bottom left and larger first deterministic heuristics were also studied. The proposed process is suited for non convex polygons and containers, the containers can have holes inside. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this study was to determine whether bone marrow-derived cells can differentiate into myofibroblasts, as defined by alpha-smooth muscle actin (SMA) expression, that arise in the corneal stroma after irregular phototherapeutic keratectomy and whose presence within the cornea is associated with corneal stromal haze. C578L/6J-GFP chimeric mice were generated through bone marrow transplantation from donor mice that expressed enhanced green fluorescent protein (GFP) in a high proportion of their bone marrow-derived cells. Twenty-four GFP chimeric mice underwent haze-generating corneal epithelial scrape followed by irregular phototherapeutic keratectomy (PTK) with an excimer laser in one eye. Mice were euthanized at 2 weeks or 4 weeks after PTK and the treated and control contralateral eyes were removed and cryo-preserved for sectioning for immunocytochemistry. Double immunocytochemistry for GFP and myofibroblast marker alpha-smooth muscle actin (SMA) were performed and the number of SMA+GFP+, SMA+GFP, SMA-GFP+ and SMA GFP cells, as well as the number of DAPI+ cell nuclei, per 400x field of stroma was determined in the central, mid-peripheral and peri-limbal cornea. In this mouse model, there were no SMA+ cells and only a few GFP+ cells detected in unwounded control corneas. No SMA+ cells were detected in the stroma at two weeks after irregular PTK, even though there were numerous GFP+ cells present. At 4 weeks after irregular PTK, all corneas developed mild to moderately severe corneal haze. In each of the three regions of the corneas examined, there were on average more than 9x more SMA+GFP+ than SMA+GFP myofibroblasts. This difference was significant (p < 0.01). There were significantly more (p < 0.01) SMA GFP+ cells, which likely include inflammatory cells, than SMA+GFP+ or SMA+GFP cells, although SMA GFP cells represent the largest population of cells in the corneas. In this mouse model, the majority of myofibroblasts developed from bone marrow-derived cells. It is possible that all myofibroblasts in these animals developed from bone marrow-derived cells since mouse chimeras produced using this method had only 60-95% of bone marrow-derived cells that were GFP+ and it is not possible to achieve 100% chimerization. This model, therefore, cannot exclude the possibility of myofibroblasts also developed from keratocytes and/or corneal fibroblasts. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The toadfishes Tetractenos hamiltoni and Torquigener pleurogramma (Tetraodontidae) possess occlusable yellow corneas. We examine the light transmission and location of the yellow/orange pigment throughout the cornea, the temporal properties of pigment migration and the ultrastructure of the pigmented processes during light- and dark-adaptation. Each species was dark-adapted during the day and light-adapted during the night and then exposed to either sun illumination or darkness for different lengths of time (0-70 min). Movement of corneal pigment could be induced in both species regardless of time of day or night. The pigment was able to migrate in a dorsal or ventral direction and changed from minimal to maximal pigmentation within 60 min. Three types of transmission curves were found with varying degrees of transmission in the 400-500 nm waveband, indicating that the pigment distribution is not uniform across the cornea; some areas of the cornea transmit near UV light, while others absorb blue light. The gradual change of the transmission characteristics in different areas of the cornea indicates the presence of different concentrations of a single type of pigment. Ultrastructural examination of the corneas showed that the layer containing the pigment is situated within the scleral cornea either surrounding (T. pleurogramma) or abutting (T. hamiltoni) an iridescent layer. Long sheet-like processes or chromatophores extending centrally from dorsal and ventral reservoirs are filled with pigment during the light-adapted state but empty in the dark-adapted state.
Resumo:
OBJECTIVE: To analyze the putative effect of type of shift and its interaction with leisure-time physical activity on cardiovascular risk factors in truck drivers.METHODS: A cross-sectional study was undertaken on 57 male truck drivers working at a transportation company, of whom 31 worked irregular shifts and 26 worked on the day-shift. Participants recorded their physical activity using the International Physical Activity Questionnaire along with measurements of blood pressure, body mass index and waist-hip ratio. Participants also provided a fasting blood sample for analysis of lipid-related outcomes. Data were analyzed using a factorial model which was covariate-controlled for age, smoking, work demand, control at work and social support.RESULTS: Most of the irregular-shift and day-shift workers worked more than 8 hours per day (67.7% and 73.1%, respectively). The mean duration of experience working the irregular schedule was 15.7 years. Day-shift workers had never engaged in irregular-shift work and had been working as a truck driver for 10.8 years on average. The irregular-shift drivers had lower work demand but less control compared to day-shift drivers (p < 0.05). Moderately-active irregular-shift workers had higher systolic and diastolic arterial pressures (143.7 and 93.2 mmHg, respectively) than moderately-active day-shift workers (116 and 73.3 mmHg, respectively) (p < 0.05) as well as higher total cholesterol concentrations (232.1 and 145 mg/dl, respectively) (p = 0.01). Irrespective of their physical activity, irregular-shift drivers had higher total cholesterol and LDL-cholesterol concentrations (211.8 and 135.7 mg/dl, respectively) than day-shift workers (161.9 and 96.7 mg/dl, respectively (ANCOVA, p < 0.05).CONCLUSIONS: Truck drivers are exposed to cardiovascular risk factors due to the characteristics of the job, such as high work demand, long working hours and time in this profession, regardless of shift type or leisure-time physical activity.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Informática
Resumo:
Face à estagnação da tecnologia uniprocessador registada na passada década, aos principais fabricantes de microprocessadores encontraram na tecnologia multi-core a resposta `as crescentes necessidades de processamento do mercado. Durante anos, os desenvolvedores de software viram as suas aplicações acompanhar os ganhos de performance conferidos por cada nova geração de processadores sequenciais, mas `a medida que a capacidade de processamento escala em função do número de processadores, a computação sequencial tem de ser decomposta em várias partes concorrentes que possam executar em paralelo, para que possam utilizar as unidades de processamento adicionais e completar mais rapidamente. A programação paralela implica um paradigma completamente distinto da programação sequencial. Ao contrário dos computadores sequenciais tipificados no modelo de Von Neumann, a heterogeneidade de arquiteturas paralelas requer modelos de programação paralela que abstraiam os programadores dos detalhes da arquitectura e simplifiquem o desenvolvimento de aplicações concorrentes. Os modelos de programação paralela mais populares incitam os programadores a identificar instruções concorrentes na sua lógica de programação, e a especificá-las sob a forma de tarefas que possam ser atribuídas a processadores distintos para executarem em simultâneo. Estas tarefas são tipicamente lançadas durante a execução, e atribuídas aos processadores pelo motor de execução subjacente. Como os requisitos de processamento costumam ser variáveis, e não são conhecidos a priori, o mapeamento de tarefas para processadores tem de ser determinado dinamicamente, em resposta a alterações imprevisíveis dos requisitos de execução. `A medida que o volume da computação cresce, torna-se cada vez menos viável garantir as suas restrições temporais em plataformas uniprocessador. Enquanto os sistemas de tempo real se começam a adaptar ao paradigma de computação paralela, há uma crescente aposta em integrar execuções de tempo real com aplicações interativas no mesmo hardware, num mundo em que a tecnologia se torna cada vez mais pequena, leve, ubíqua, e portável. Esta integração requer soluções de escalonamento que simultaneamente garantam os requisitos temporais das tarefas de tempo real e mantenham um nível aceitável de QoS para as restantes execuções. Para tal, torna-se imperativo que as aplicações de tempo real paralelizem, de forma a minimizar os seus tempos de resposta e maximizar a utilização dos recursos de processamento. Isto introduz uma nova dimensão ao problema do escalonamento, que tem de responder de forma correcta a novos requisitos de execução imprevisíveis e rapidamente conjeturar o mapeamento de tarefas que melhor beneficie os critérios de performance do sistema. A técnica de escalonamento baseado em servidores permite reservar uma fração da capacidade de processamento para a execução de tarefas de tempo real, e assegurar que os efeitos de latência na sua execução não afectam as reservas estipuladas para outras execuções. No caso de tarefas escalonadas pelo tempo de execução máximo, ou tarefas com tempos de execução variáveis, torna-se provável que a largura de banda estipulada não seja consumida por completo. Para melhorar a utilização do sistema, os algoritmos de partilha de largura de banda (capacity-sharing) doam a capacidade não utilizada para a execução de outras tarefas, mantendo as garantias de isolamento entre servidores. Com eficiência comprovada em termos de espaço, tempo, e comunicação, o mecanismo de work-stealing tem vindo a ganhar popularidade como metodologia para o escalonamento de tarefas com paralelismo dinâmico e irregular. O algoritmo p-CSWS combina escalonamento baseado em servidores com capacity-sharing e work-stealing para cobrir as necessidades de escalonamento dos sistemas abertos de tempo real. Enquanto o escalonamento em servidores permite partilhar os recursos de processamento sem interferências a nível dos atrasos, uma nova política de work-stealing que opera sobre o mecanismo de capacity-sharing aplica uma exploração de paralelismo que melhora os tempos de resposta das aplicações e melhora a utilização do sistema. Esta tese propõe uma implementação do algoritmo p-CSWS para o Linux. Em concordância com a estrutura modular do escalonador do Linux, ´e definida uma nova classe de escalonamento que visa avaliar a aplicabilidade da heurística p-CSWS em circunstâncias reais. Ultrapassados os obstáculos intrínsecos `a programação da kernel do Linux, os extensos testes experimentais provam que o p-CSWS ´e mais do que um conceito teórico atrativo, e que a exploração heurística de paralelismo proposta pelo algoritmo beneficia os tempos de resposta das aplicações de tempo real, bem como a performance e eficiência da plataforma multiprocessador.
Resumo:
Neste artigo analisa-se uma importante relação teórica nos estudos históricos sobre a forma urbana. Trata-se da relação que associa as formas urbanas regulares ao planeamento urbanístico e, pelo contrário, as formas urbanas irregulares à falta de planeamento urbanístico. Partindo da formulação inicial estabelecida nos textos inaugurais de história do urbanismo, procura-se verificar o impacto desta relação dicotómica na construção do conhecimento, para depois alcançar a transformação operada nas últimas décadas, que levou à sua refutação, utilizando para o efeito o contributo metodológico, teórico e conceptual de alguns estudos produzidos desde a segunda metade do século XX.