997 resultados para Ip Method
Resumo:
OBJECTIVES: Evaluate the sensitivity/specificity of immunoperoxidase method in comparison with the standard immunofluorescence. MATERIAL AND METHODS: Retrospective review of 87 biopsies made for allograft dysfunction. Immunofluorescence (IF) was performed in frozen allograft biopsies using monoclonal antibody anti-C4d from Quidel®. The indirect immunoperoxidase (IP) technique was performed in paraffin-embebbed tissue with polyclonal antiserum from Serotec®. Biopsies were independently evaluated by two nephropathologist according Banff 2007 classification. RESULTS: By IF, peritubular C4d deposition were detected in 60 biopsies and absent in 27 biopsies. The evaluation of biopsy by IP was less precise due to the presence of background and unspecific staining. We find 13.8% (12/87) of false negative and Banff classification concordance in 79.3% (69/87) of cases (table1). The ROC curve study reveal a specificity of 100% and sensitivity of 80.0 % of IP method in relation to the gold standard (area under curve:0.900; 95% Confidence interval :0.817-0.954; p=0.0001). Banff Classification C4d Cases Immunofluorescence Immunoperoxidase n =87 Diffuse Negative 3 (3.4%) Focal Negative 9 (10.3%) Negative Negative 27 (31.0%) Diffuse Diffuse 33 (37.9%) Focal Focal 9 (10.3%) Diffuse Focal 6 (6.9%) CONCLUSION: The IP method presents a good specificity, but lesser sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring more experience of the observer than IF method. If frozen tissue is unavailable, the use of IP for C4d detection is acceptable.
Resumo:
Différentes translocations génomiques sont fréquemment associées à l'apparition de leucémies myéloïdes aiguës (LMA). Ces translocations génomiques résultent de l’assemblage de deux gènes conduisant à la production d'une protéine de fusion. C'est le cas de la translocation t (3; 5) (q25.1; q34) impliquant le suppresseur tumoral NPM et l'oncogène MLF1 donnant naissance à la protéine de fusion NPM-MLF1. Généralement, les gènes impliqués dans ces translocations contrôlent la croissance cellulaire, la différenciation ou la survie cellulaire. Cependant, pour NPM-MLF1 les causes du gain ou de la perte de fonction associée à la translocation demeurent inconnues car nous ne savons pas comment cette translocation peut favoriser ou participer à l'avènement de la LMA. Le but de ce travail est d’analyser le rôle de NPM-MLF1 dans le cancer et d’examiner comment son activité contribue à la leucémie en faisant des études d’interactions protéine/protéine. En effet, l’étude de la fonction d’une protéine implique souvent de connaître ses partenaires d’interactions. Pour ce faire, la technique de double hybride dans la souche de levure AH109 a été utilisée. Tout d’abord, les ADN complémentaires (ADNc) de MLF1, NPM1 et de NPM-MLF1, MLF1-Like (une partie de MLF1 de l’acide aminé 94 à 157) normaux et mutés du domaine MTG8-Like constitué des acides aminés (a.a.) 151 à 164 de MLF1 (excepté NPM) ont été clonés dans un vecteur d'expression de levure pGBKT7. Les ADNc de GFI-1, mSin3A, PLZF, HDAC1 et HDAC3 ont été clonés dans le plasmide pGADT7 de façon à créer des protéines de fusion synthétiques avec le domaine de liaison à l'ADN et de trans-activation de la protéine GAL4. Le plasmide pGBKT7 possède un gène TRP1 et pGADT7 un gène LEU2 qui permettent la sélection des clones insérés dans la levure. Aussi, le pGBKT7 a un épitope c-myc et pGADT7 un épitope HA qui permet de voir l’expression des protéines par buvardage de type Western. Après la transformation des levures les interactions protéine/protéine ont été observées en vérifiant l’expression des gènes rapporteurs HIS3, LacZ, MEL1, ADE2 de la levure en utilisant des milieux de sélection YPD/-Leu/-Trp, YPD/-Leu/-Trp/-His, YPD/-Leu/-Trp/-His/-Ade, YPD/-Leu/-Trp/+ X-Gal, YPD/-Leu/-Trp/ + X-α-Gal. Ensuite, les interactions trouvées par double-hybride ont été vérifiées dans les cellules érythroleucémiques K562 par immuno-précipitation (IP) de protéines suivies de buvardages Westerns avec les anticorps appropriés. NPM-MLF1, MLF1, MTG8, MLF1-Like surexprimés dans les cellules K562 ont été clonés dans le plasmide pOZ-FH-N. pOZ-FH-N possède un récepteur IL-2 qui permet de sélectionner les cellules qui l’expriment ainsi qu’un tag Flag-HA qui permet de voir l’expression des protéines par buvardage-Western. Les résultats du double-hybride suggèrent une interaction faible de NPM-MLF1 avec HDAC1, HDAC3 et mSin3A ainsi qu’une interaction qui semble plus évidente entre NPM-MLF1 et PLZF, GFI-1. NPM interagit avec GFI-1 et mSin3A. Aussi, MLF1 et MLF1-Like interagissent avec HDAC1, HDAC3, GFI-1, PLZF mais pas avec mSin3A. Les IP suggèrent que NPM-MLF1 interagit avec HDAC1, HDAC3, mSin3A et PLZF. MLF1 et MLF1-Like interagissent avec HDAC1, HDAC3 et mSin3A. L’interaction de NPM-MLF1 avec GFI-1, MLF1 et MLF1-Like avec PLZF et GFI-1 n’a pas encore été vérifiée par IP. Ainsi, nos observations permettent de suggérer que NPM-MF1, MLF1 et NPM pourraient jouer un rôle dans la transcription et la régulation de l’expression de certains gènes importants dans l’hématopoïèse et une variété de processus cellulaires parce qu’ils interagissent avec différents corépresseurs. En déterminant les partenaires protéiques de MLF1, NPM et NPM-MLF1, leurs fonctions et comment NPM-MLF1 influence et modifie le fonctionnement cellulaire normal; il sera possible de renverser le processus de LMA favorisé par la t (3; 5) NPM-MLF1 par la technologie d’interférence à l’ARN.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Immunoprecipitation (IP) is one of the most widely used and selective techniques for protein purification. Here, a miniaturised, polymer-supported immunoprecipitation (µIP) method for the on-chip purification of proteins from complex mixtures is described. A 4 µl PDMS column functionalised with covalently bound antibodies was created and all critical aspects of the µIP protocol (antibody immobilisation, blocking of potential non-specific adsorption sites, sample incubation and washing conditions) were assessed and optimised. The optimised µIP method was used to obtain purified fractions of affinity-tagged protein from a bacterial lysate.
Resumo:
It is well known that trichomes protect plant organs, and several studies have investigated their role in the adaptation of plants to harsh environments. Recent studies have shown that the production of hydrophilic substances by glandular trichomes and the deposition of this secretion on young organs may facilitate water retention, thus preventing desiccation and favouring organ growth until the plant develops other protective mechanisms. Lychnophora diamantinana is a species endemic to the Brazilian 'campos rupestres' (rocky fields), a region characterized by intense solar radiation and water deficits. This study sought to investigate trichomes and the origin of the substances observed on the stem apices of L. diamantinana. Samples of stem apices, young and expanded leaves were studied using standard techniques, including light microscopy and scanning and transmission electron microscopy. Histochemical tests were used to identify the major groups of metabolites present in the trichomes and the hyaline material deposited on the apices. Non-glandular trichomes and glandular trichomes were observed. The material deposited on the stem apices was hyaline, highly hydrophilic and viscous. This hyaline material primarily consists of carbohydrates that result from the partial degradation of the cell wall of uniseriate trichomes. This degradation occurs at the same time that glandular trichomes secrete terpenoids, phenolic compounds and proteins. These results suggest that the non-glandular trichomes on the leaves of L. diamantinana help protect the young organ, particularly against desiccation, by deposition of highly hydrated substances on the apices. Furthermore, the secretion of glandular trichomes probably repels herbivore and pathogen attacks.
Resumo:
It is difficult to get the decision about an opinion after many users get the meeting in same place. It used to spend too much time in order to find solve some problem because of the various opinions of each other. TAmI (Group Decision Making Toolkit) is the System to Group Decision in Ambient Intelligence [1]. This program was composed with IGATA [2], WebMeeting and the related Database system. But, because it is sent without any encryption in IP / Password, it can be opened to attacker. They can use the IP / Password to the bad purpose. As the result, although they make the wrong result, the joined member can’t know them. Therefore, in this paper, we studied the applying method of user’s authentication into TAmI.
Resumo:
Injectable biomaterials with in situ cross-linking reactions have been suggested to minimize the invasiveness associated with most implantation procedures. However, problems related with the rapid liquid-to-gel transition reaction can arise because it is difficult to predict the reliability of the reaction and its end products, as well as to mitigate cytotoxicity to the surrounding tissues. An alternative minimally invasive approach to deliver solid implants in vivo is based on injectable microparticles, which can be processed in vitro with high fidelity and reliability, while showing low cytotoxicity. Their delivery to the defect can be performed by injection through a small diameter syringe needle. We present a new methodology for the continuous, solvent- and oil-free production of photopolymerizable microparticles containing encapsulated human dermal fibroblasts. A precursor solution of cells in photo-reactive PEG-fibrinogen (PF) polymer was transported through a transparent injector exposed to light-irradiation before being atomized in a jet-in-air nozzle. Shear rheometry data provided the cross-linking kinetics of each PF/cell solution, which was then used to determine the amount of irradiation required to partially polymerize the mixture prior to atomization. The partially polymerized drops fell into a gelation bath for further polymerization. The system was capable of producing cell-laden microparticles with high cellular viability, with an average diameter of between 88.1 µm to 347.1 µm and a dispersity of between 1.1 and 2.4, depending on the parameters chosen.
Resumo:
Tämä diplomityö tutkii turvallisia etäyhteystapoja yritysverkkoihin. Samanaikasesti kuin Internettiin liitetyt langattomat verkot, kuten langattomat lähiverkot ja pakettikytkentäiset matkapuhelinverkot, tulevat yhä yleisemmiksi, mahdollisuus etäyhteksien luomiseen näiden verkkojen kautta tulee yhä suositummaksi. Vaikka tietoverkot kehittyvät, pysyvät niitä uhkaavat yleisluontoiset uhat samoina. IP pohjaiset VPN-verkot ovat sopiva tapa suojata Internetin ylitse tapahtuvia etäyhteksiä. Eri VPN-ratkaisuja on kuitenkin tarjolla laaja valikoima. Oikean tyyppisen VPN-ratkaisun valinta on kriittistä, jotta yrityksen etäyhteystarpeet saadaan täytettyä. Diplomityö esittelee eräänä vaihtoehtona miten Pocket PC 2002 PDA laitetta ja Windows XP Professional käyttöjärjestelmää voidaan käyttää edullisen VPN ratkaisun toteuttamiseen.
Resumo:
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 mu L s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), mu A) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): ip = (-20.5 +/- 0.3) Cparaquat -(0.02 +/- 0.03). The limits of detection and quantification were 2.0 and 7.0 mu g L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.
Resumo:
Com o intuito de utilizar uma rede com protocolo IP para a implementação de malhas fechadas de controle, este trabalho propõe-se a realizar um estudo da operação de um sistema de controle dinâmico distribuído, comparando-o com a operação de um sistema de controle local convencional. Em geral, a decisão de projetar uma arquitetura de controle distribuído é feita baseada na simplicidade, na redução dos custos e confiabilidade; portanto, um diferencial bastante importante é a utilização da rede IP. O objetivo de uma rede de controle não é transmitir dados digitais, mas dados analógicos amostrados. Assim, métricas usuais em redes de computadores, como quantidade de dados e taxa de transferências, tornam-se secundárias em uma rede de controle. São propostas técnicas para tratar os pacotes que sofrem atrasos e recuperar o desempenho do sistema de controle através da rede IP. A chave para este método é realizar a estimação do conteúdo dos pacotes que sofrem atrasos com base no modelo dinâmico do sistema, mantendo o sistema com um nível adequado de desempenho. O sistema considerado é o controle de um manipulador antropomórfico com dois braços e uma cabeça de visão estéreo totalizando 18 juntas. Os resultados obtidos mostram que se pode recuperar boa parte do desempenho do sistema.
Resumo:
OBJETIVO: Comparar os tempos de geração e digitação de laudos radiológicos entre um sistema eletrônico baseado na tecnologia de voz sobre o protocolo de internet (VoIP) e o sistema tradicional, em que o radiologista escreve o laudo à mão. MATERIAIS E MÉTODOS: Foi necessário modelar, construir e implantar o sistema eletrônico proposto, capaz de gravar o laudo em formato de áudio digital, e compará-lo com o tradicional já existente. Por meio de formulários, radiologistas e digitadores anotaram os tempos de geração e digitação dos laudos nos dois sistemas. RESULTADOS: Comparadas as médias dos tempos entre os sistemas, o eletrônico apresentou redução de 20% (p = 0,0410) do tempo médio de geração do laudo em comparação com o sistema tradicional. O tradicional foi mais eficiente em relação ao tempo de digitação, uma vez que a média de tempo do eletrônico foi três vezes maior (p < 0,0001). CONCLUSÃO: Os resultados mostraram diferença estatisticamente significante entre os sistemas comparados, sendo que o eletrônico foi mais eficiente do que o tradicional em relação ao tempo de geração dos laudos, porém, em relação ao tempo de digitação, o tradicional apresentou melhores resultados.
Resumo:
Pós-graduação em Agronomia (Horticultura) - FCA
Efeitos do strike das estruturas geológicas de duas dimensões nas pseudos-seções de IP resistividade
Resumo:
Os levantamentos de IP-resistividade efetuados na Serra dos Carajás não foram executados ortogonalmente às estruturas geológicas, pois utilizaram linhas anteriormente abertas pelas equipes de geoquímica. Este fato motivou este estudo teórico da influência da direção das linhas de medidas de IP-resistividade em relação ao "strike" da estrutura. Foi usado o programa de elementos finitos de Rijo (1977), desenvolvido para levantamentos perpendiculares às estruturas com as adaptações necessárias. A modificação principal foi na rotina de transformação inversa de Fourier. Para o caso simples dos levantamentos perpendiculares, a transformada inversa é uma integral discreta com apenas sete pontos. No entanto, para as medidas obliquas, o integrando é oscilatório, e portanto, a integral a ser calculada é mais complexa. Foi adaptado um método apresentado por Ting e Luke (1981), usando dezoito pontos em cada integração. Foi constatado que o efeito da direção da linha em relação ao "strike" é desprezível para ângulos maiores que 60 graus. Para ângulos menores, o efeito consiste no alongamento da anomalia, com pequenas alterações em seu centro. Não há uma maneira simples de compensar este efeito com mudanças nos parâmetros do modelo.
Resumo:
In this work, crystalline titanium dioxide (TiO2) nanoparticles with variable average crystallite sizes (e.g., 8 nm) and surface areas (e.g., 192 m² g-1) were synthesized in pure anatase phase using H2O2 to reduce the hydrolysis rate of the titanium ions. An isopropanol (IP) solution was employed as the reaction medium. The TiO2 nanoparticles were characterized by powder X-ray diffraction analysis (XRD), Raman spectroscopy and transmission electron microscopy (TEM). By changing the synthesis parameters it was possible to control nanoparticle size and avoid the coalescence process. A dependence of the Raman wavenumber on the nanocrystal sizes was determined, which is quite useful for a quick check of the size of TiO2 nanocrystals.
Resumo:
Possibilities for investigations of 43 varieties of file formats (objects), joined in 10 groups; 89 information attacks, joined in 33 groups and 73 methods of compression, joined in 10 groups are described in the paper. Experimental, expert, possible and real relations between attacks’ groups, method’ groups and objects’ groups are determined by means of matrix transformations and the respective maximum and potential sets are defined. At the end assessments and conclusions for future investigation are proposed.