335 resultados para Intubation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To provide a detailed description of the nasopharyngeal intubation (NPI) technique and photographs, which should be helpful for those who may need to perform it for treating the airway obstruction in Robin sequence. Design: To describe and illustrate the NPI technique and the necessary considerations for its application. Setting: Hospital de Reabilitacao de Anomalias Craniofacial of University of Sao Paulo, Brazil. Result: The NPI procedure involves the use of a whitish, Portex, number 3.0 or 3.5, silicone tube, introduced 8 cm deep into the infant`s nostril and fixed with Micropore tape. The tube is to be removed at least twice a day for proper hygiene (with running water, detergent, and swabs) and should be changed every 7 days. This procedure is taught to the children`s parents or caretakers by the nurse during hospitalization. Conclusion: The technique is so simple that it can be performed by the parents themselves, allowing continuation of the treatment at home.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Upper airway stenosis (UAS) after endotracheal intubation is a common problem in children. Most literature refers to a surgical treatment for these lesions. Laryngotracheal reconstruction and cricotracheal resection are used for low- and high-grade stenosis, but decannulation is not always possible immediately after surgery. Purpose: The aim of this study was to verify the feasibility and results of endoscopic dilatations for treatment of subglottic stenosis. Method: The study encompassed a 12-year retrospective analysis of patients treated for UAS in a tertiary center. All children were symptomatic at the time of the endoscopic diagnosis. The stenosis was graded according to the Myer-Cotton criteria. Endoscopic dilatation was initiated immediately after the diagnosis. Children with grade IV stenosis underwent surgery. Results: Children with tracheal stenosis and no involvement of the subglottic area did not respond to endoscopic dilatations and underwent surgery. There were 45 children with grade I stenosis, 12 with grade II, 7 with grade III, and 4 with grade IV lesions. Patients with grade I, II, and III stenosis were a] I treated by endoscopic dilatations alone and were decannulated when asymptomatic. The average time for decannulation was 18.90 +/- 26.07 months for grade 1, 32.5 +/- 27.08 months for grade 11, and 27.57 +/- 20.60 months for grade III stenosis (P < .01, for grade II vs grade III). Conclusion: Grade I, II, and III subglottic stenoses can be safely managed by early endoscopic dilatations with a high rate of success and low rate of morbidity but require a significantly long period of treatment. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the prevalence of abnormal gastroesophageal reflux in infants with Robin sequence who had severe respiratory obstruction treated with nasopharyngeal intubation and to evaluate the efficacy of nonsurgical treatment. Design: Longitudinal prospective study. Setting: Hospital de Reabilitacao de Anomalias Craniofaciais, University of Sao Paulo, Brazil. Patients: Twenty infants with severe isolated Robin sequence treated with nasopharyngeal intubation. Interventions: We performed 24-hour esophageal pH monitoring on each child at 2, 4, and 6 months of age. Respiratory and feeding status were evaluated. We considered abnormal gastroesophageal reflux as reflux index values above the 95th percentile of the Vandenplas reference for normal children. Results: The prevalence of reflux index above the 95th percentile at the first exam was 6/20, a value significantly higher than the reference (5/103, p < .01). At the second and third exams, reflux index values were decreased. Ninety percent of the infants showed improvement of respiratory difficulty and developed oral feeding capacity. Conclusions: The prevalence of abnormal gastroesophageal reflux is higher in infants with severe cases of Robin sequence than in normal infants. Nonsurgical procedures improved respiratory and feeding difficulties of most of these infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : Contexte clinique et objectifs: l'intubation oro-trachéale peut être plus difficile chez les patients obèses morbides (index de masse corporelle BMI > 35 kg/m2) que chez les patients non-obèses. Récemment, de nouveaux instruments permettant une intubation assistée au moyen d'une caméra ont été développés. Notre expérience pratique avec la vidéolaryngoscopie nous a conduit à l'hypothèse que celle-ci pourrait améliorer la vision laryngoscopique chez cette population spécifique et de ce fait faciliter l'intubation. Le but de cette étude était donc d'évaluer le bénéfice du vidéolaryngoscope sur le grade de laryngoscopie chez le patient obèse morbide. Résultats : le grade laryngoscopique fut abaissé de manière significative avec le vidéolaryngoscope comparé à la vision directe avec un laryngoscope standard. Lorsque le grade laryngoscopique était plus grand que 1 à la laryngoscopie directe, il fut dans la grande majorité des cas (93% des patients) abaissé avec le vidéolaryngoscope. Chez les 7 % restant, le grade laryngoscopique resta identique. Conclusions : chez le patient obèse morbide, l'utilisation du vidéolaryngoscope améliore de manière significative la visualisation du larynx et de ce fait facilite l'intubation. Une application systématique de ce procédé pourrait donc permettre de réduire l'incidence d'une intubation difficile ainsi que ses conséquences chez cette population de patients. Summary : Background and objective: Tracheal intubation may be more difficult in morbidly obese patients (body mass index >35 kgM-2) than in the non-obese. Recently, new video-assisted intubation devices have been developed. After some experience with videolaryngoscopy, we hypothesized that it could improve the laryngoscopic view in this specific population and therefore facilitate intubation. The aim of this study was to assess the benefit of a videolaryngoscope on the grade of laryngoscopy in morbid obesity. Methods: We studied 80 morbidly obese patients undergoing bariatric surgery. They were randomly assigned to one of two groups. One group was intubated with the help of the videolaryngoscope and in the control group the screen of the videolaryngoscope was hidden to the intubating anaesthesiologist. The primary end-point of the study was to assess in both groups the Cormack and Lehane direct and indirect grades of laryngoscopy. The duration of intubation, the number of attempts needed as well as the minimal SPO2 reached during the intubation process were measured. Results: Grade of laryngoscopy was significantly lower with the videolaryngoscope compared with the direct vision (P < 0.001). When the grade of laryngoscopy was higher than one with the direct laryngoscopy (n = 30), it was lower in 28 cases with the videolaryngoscope and remained the same only in two cases (P < 0.001). The minimal SPO2 reached during the intubation was higher with the videolaryngoscope but it did not reach statistical significance. Conclusions: In morbidly obese patients, the use of the videolaryngoscope significantly improves the visualization of the larynx and thereby facilitates intubation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPPORT DE SYNTHÈSE : Chez les patients présentant une pathologie de la colonne cervicale, l'instrumentation des voies aériennes peut s'avérer délicate. En effet, l'impossibilité d'effectuer une extension de la nuque afin d'aligner correctement l'axe oro-pharyngo-trachéal, ainsi que l'ouverture de bouche limitée par la présence d'une minerve cervicale, rendent la laryngoscopie standard extrêmement difficile. Le but de cette étude est de démontrer que l'intubation oro-trachéale avec une minerve cervicale semi-rigide est possible à l'aide d'un vidéolaryngoscope récemment développé, le GlideScope®. Celui-ci est formé d'une lame courbe présentant une angulation accentuée à 60° à partir de son milieu, avec une petite caméra haute résolution et une source lumineuse enchâssées dans la partie inférieure au point d'inflexion. Différents travaux ont montré les avantages du GlideScope® par rapport à la lame de Macintosh standard "pour l'instrumentation des voies aériennes de routine ou en situation difficile. Après acceptation par la Commission d'Ethique, 50 patients, adultes consentants et programmés pour une intervention chirurgicale élective nécessitant une anesthésie générale ont été inclus dans cette étude. Malgré la présence d'une minerve cervicale semi-rigide Philadelphia® Patriot correctement positionnée et la tête fixée à la table d'opération, tous les patients ont pu être intubés a l'aide du GlideScope®. Aucune complication n'a été documentée pendant la procédure ou en post-opératoire. De plus, nous avons démontré que dans cette situation la visualisation des structures laryngées est significativement améliorée grâce au GlideScope®, par rapport à la lame de Macintosh utilisée lors de toute intubation standard. En conclusion, l'intubation oro-trachéale chez les patients ayant une minerve cervicale et la tête fixée est possible à l'aide du GlideScope®. La meilleure façon de sécuriser les voies aériennes chez les patients présentant une instabilité de la colonne cervicale est un sujet fortement débattu. L'utilisation du GlideScope® pourrait s'avérer une alternative intéressante, en particulier dans les situations d'urgence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot (R) cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope (R) and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack-Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients' tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43-61 s). The modified Cormack-Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi-rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical ventilation (MV) is life-saving but potentially harmful for lungs of premature infants. So far, animal models dealt with the acute impact of MV on immature lungs, but less with its delayed effects. We used a newborn rodent model including non-surgical and therefore reversible intubation with moderate ventilation and hypothesized that there might be distinct gene expression patterns after a ventilation-free recovery period compared to acute effects directly after MV. Newborn rat pups were subjected to 8 hr of MV with 60% oxygen (O(2) ), 24 hr after injection of lipopolysaccharide (LPS), intended to create a low inflammatory background as often recognized in preterm infants. Animals were separated in controls (CTRL), LPS injection (LPS), or full intervention with LPS and MV with 60% O(2) (LPS + MV + O(2) ). Lungs were recovered either directly following (T:0 hr) or 48 hr after MV (T:48 hr). Histologically, signs of ventilator-induced lung injury (VILI) were observed in LPS + MV + O(2) lungs at T:0 hr, while changes appeared similar to those known from patients with chronic lung disease (CLD) with fewer albeit larger gas exchange units, at T:48 hr. At T:0 hr, LPS + MV + O(2) increased gene expression of pro-inflammatory MIP-2. In parallel anti-inflammatory IL-1Ra gene expression was increased in LPS and LPS + MV + O(2) groups. At T:48 hr, pro- and anti-inflammatory genes had returned to their basal expression. MMP-2 gene expression was decreased in LPS and LPS + MV + O(2) groups at T:0 hr, but no longer at T:48 hr. MMP-9 gene expression levels were unchanged directly after MV. However, at T:48 hr, gene and protein expression increased in LPS + MV + O(2) group. In conclusion, this study demonstrates the feasibility of delayed outcome measurements after a ventilation-free period in newborn rats and may help to further understand the time-course of molecular changes following MV. The differences obtained from the two time points could be interpreted as an initial transitory increase of inflammation and a delayed impact of the intervention on structure-related genes. Pediatr Pulmonol. 2012; 47:1204-1214. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In patients with cervical spine injury, a cervical collar may prevent cervical spine movements but renders tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesized that despite the presence of a semi-rigid cervical collar and with the patient's head taped to the trolley, we would be able to intubate all patients with the GlideScopeR and its dedicated stylet. Methods: 50 adult patients (ASA 1 or 2, BMI ≤35 kg/m2) scheduled for elective surgical procedures requiring tracheal intubation were included. After standardized induction of general anesthesia and neuromuscular blockade, the neck was immobilized with an appropriately sized semi-rigid Philadelphia Patriot® cervical collar, the head was taped to the trolley. Laryngoscopy was attempted using a Macintosh laryngoscope blade 4 and the modified Cormack Lehane grade was noted. Subsequently, laryngoscopy with the GlideScopeR was graded and followed by oro-tracheal intubation. Results: All patients were successfully intubated with the GlideScopeR and its dedicated stylet. The median intubation time was 50 sec [43; 61]. The modified Cormack Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScopeR (p <0.0001), reaching 2a in most of patients. Maximal mouth opening was significantly reduced with the cervical collar applied, 4.5 cm [4.5; 5.0] vs. 2.0 cm [1.8; 2.0] (p <0.0001). Conclusions: The GlideScope® allows oro-tracheal intubation in patients having their cervical spine immobilized by a semi-rigid collar and their head taped to the trolley. It furthermore decreases significantly the modified Cormack Lehane grade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La prise en charge des voies aériennes est un aspect majeur de l'anesthésie dont le défaut de gestion reste la première cause de mortalité per-anesthésique. La fibroscopie reste à l'heure actuelle une technique clé pour la gestion des situations d'intubation difficiles, mais les fibroscopes standards réutilisables sont couteux, fragiles et doivent être nettoyés et désinfectés entre chaque utilisation. L'apparition sur le marché de l'Ambu ®aScope?2, vidéoscope souple à usage unique pourrait servir d'alternative si ses capacités d'intubation dans des situations cliniques difficiles étaient démontrées. Plusieurs études existaient démontrant l'efficacité de cet appareil sur des mannequins en situation standard ou difficile simulée, mais aucune n'avait testé son efficacité dans des situations difficiles sur patients réels, l'expérience dans se domaine se limitant à quelques case reports. Le but de cette étude était de comparer l'Ambu ®aScope?2 au fibroscope conventionnel dans des situations d'intubation difficiles sur patients réels. Après leur accord, 100 patients prévus pour une chirurgie élective nécessitant une intubation oro-trachéale ont été répartis de façon aléatoire en deux groupes homogènes de 50. La difficulté d'intubation était induite par la mise en place d'une minerve semi-rigide après anesthésie générale, empêchant ainsi toute mobilisation cervicale et limitant grandement l'ouverture de bouche. Les points de comparaisons étaient : Succès ou échec d'intubation, temps nécessaire pour la procédure, difficulté subjective du geste et qualité de vision des structures anatomiques. Tous les patients ont été intubés avec succès dans les deux groupes dans des délais tout à fait satisfaisant. Cependant, le temps nécessaire à l'obtention d'un positionnement correct du tube dans la trachée était significativement plus long avec l'Ambu ®aScope?2. Par ailleurs, la qualité de vision, tout en restant suffisante pour permettre l'intubation était globalement moins bonne avec l'appareil à usage unique. Quand à la difficulté subjective du geste, elle était plus souvent classée intermédiaire ou difficile dans ce groupe, sans pour autant que la différence soit significative. Les difficultés étaient principalement dues à un manque de mobilité de la partie flexible, l'absence de canal d'aspiration des sécrétions et une lentille de moins bonne qualité, troublant la vision au contacte de la salive. Bien que le taux de succès des intubations soit identique dans les deux groupes, il est probable que la solide expérience de l'anesthésiste en matière de fibroscopie ait permis de contourner les conditions plus difficiles du groupe de l'Ambu ®aScope?2 et ses performances techniques inférieures. Il est donc difficile de le recommander comme alternative équivalentes au fibroscope conventionnel pour les diverses situations d'intubation difficiles que l'on peut rencontre en clinique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Difficult tracheal intubation remains a constant and significant source of morbidity and mortality in anaesthetic practice. Insufficient airway assessment in the preoperative period continues to be a major cause of unanticipated difficult intubation. Although many risk factors have already been identified, preoperative airway evaluation is not always regarded as a standard procedure and the respective weight of each risk factor remains unclear. Moreover the predictive scores available are not sensitive, moderately specific and often operator-dependant. In order to improve the preoperative detection of patients at risk for difficult intubation, we developed a system for automated and objective evaluation of morphologic criteria of the face and neck using video recordings and advanced techniques borrowed from face recognition. Method and results: Frontal video sequences were recorded in 5 healthy volunteers. During the video recording, subjects were requested to perform maximal flexion-extension of the neck and to open wide the mouth with tongue pulled out. A robust and real-time face tracking system was then applied, allowing to automatically identify and map a grid of 55 control points on the face, which were tracked during head motion. These points located important features of the face, such as the eyebrows, the nose, the contours of the eyes and mouth, and the external contours, including the chin. Moreover, based on this face tracking, the orientation of the head could also be estimated at each frame of the video sequence. Thus, we could infer for each frame the pitch angle of the head pose (related to the vertical rotation of the head) and obtain the degree of head extension. Morphological criteria used in the most frequent cited predictive scores were also extracted, such as mouth opening, degree of visibility of the uvula or thyreo-mental distance. Discussion and conclusion: Preliminary results suggest the high feasibility of the technique. The next step will be the application of the same automated and objective evaluation to patients who will undergo tracheal intubation. The difficulties related to intubation will be then correlated to the biometric characteristics of the patients. The objective in mind is to analyze the biometrics data with artificial intelligence algorithms to build a highly sensitive and specific predictive test.