777 resultados para Intraocular lenses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate the long-term graft survival in patients with flexible open-loop anterior chamber intraocular lenses (AC IOL). Methods. We retrospectively reviewed the records of patients with aphakic/pseudophakic bullous keratopathy who underwent penetrating keratoplasty and flexible open-loop AC IOL implantation in our institution from 1983 to 1988. Results. 79 eyes from 77 patients were included in the study. Mean follow-up was 50 months (range 1 to 123 months). At last follow-up 61 eyes (77.2%) had clear grafts. Among them, the visual acuity was = 20/40 in 14 eyes (23.0%), 20/50-20/100 in 22 eyes (36.1%), 20/200-20/400 in 9 eyes (14.8%) and = CF in 16 (26.2%). Increment of glaucoma medications and/or glaucoma surgery was the most frequent complication (37 eyes, 46,8%). Cystoid macular edema was newly diagnosed in 10 eyes (12.7%). Conclusions. Flexible, open-loop anterior chamber lens are a viable option in the treatment of patients with aphakic or pseudophakic bullous keratopathy undergoing penetrating keratoplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate the long-term graft survival and complications of flexible, open-loop anterior-chamber intraocular lenses in patients with penetrating keratoplasty for pseudophakic or aphakic bullous keratopathy. Methods. We reviewed charts of all consecutive patients who underwent penetrating keratoplasty for pseudophakic or aphakic bullous keratopathy combined with implantation of a flexible, open-loop, anterior-chamber intraocular lens at our institution between 1983 and 1988. One-hundred one eyes of 99 patients were evaluated. Graft-survival rates were calculated by using the Kaplan-Meier actuarial method. Results. Mean follow-up was 49.8 months (range. 1-144). The probability of graft survival at 1, 2, 4, 6, and 8 years was 93, 87, 78, 65, and 65%, respectively. A total of 25 (24.8%) grafts failed. Progressive corneal edema without signs of rejection was the most common finding in patients with failed grafts (10 eyes, 40%). The most frequent complication observed was newly diagnosed or worsening of preexisting glaucoma (46 eyes, 45.5%). Conclusions. Our long-term results support flexible, open-loop anterior-chamber intraocular lenses as a reasonable option, at the time of penetrating keratoplasty, in patients with pseudophakic and aphakic bullous keratopathy.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Secondary intraocular lens (IOL) implantation is exposed to an increased risk of complications, including endophthalmitis and retinal detachment. The present analysis compares the outcomes and complications experienced in our own series of patients. PATIENTS AND METHODS: We retrospectively reviewed a consecutive series of secondary posterior chamber IOL implantations performed in a single centre, two surgeon setting over a period of 8 years and with a follow up-time of at least 4 months. RESULTS: Between 1997 and 2005, 75 patients received a sulcus-supported secondary IOL without suture fixation, whereas suture fixation was required in 137 instances. Visual acuity improved in both groups (group 1: from 0.36 +/- 0.39 (0.01-1.2) to 0.73 +/- 0.33 (0.02-1.0; p = 0.18); group 2: from 0.33 +/- 0.34 (0.02-1.0) to 0.46 +/- 0.33 (0.01-1.0; p = 0.006), but more pronounced in eyes not requiring suture fixation (p = 0.012). IOL placement was more likely to be combined with endophacoemulsification in the not suture-fixed IOLs (12.7 vs. 5.3 %). In contrast, retinal tears (10.6 vs. 8.6 %, respectively) and retinal detachment (5.3 vs. 2.2 %, respectively) were equally distributed. In the early postoperative phase, IOP was lower in suture-fixed eyes, which showed a higher incidence of minor intraocular haemorrhages and cystoid macular edema (5.3 vs. 8.0 %); late complications up to 5 years postoperatively were equally distributed. CONCLUSION: A preoperatively less complicated anterior segment situation and a lower incidence of postoperative macular edema may account for a better visual outcome after placement of a sulcus supported IOLs without suturing. If required, suture fixation may be performed without exposing the eye to an increased risk of late postoperative complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: We report the clinical, morphological, and ultrastructural findings of 13 consecutively explanted opacified Hydroview(R) (hydrogel) intraocular lenses (IOLs). Our purpose was to provide a comprehensive account on the possible factors involved in late postoperative opacification of these IOLs. PATIENTS AND METHODS: Thirteen consecutive opacified hydrogel IOLs (Hydroview H 60 M, Bausch ; Lomb) were explanted due to the significant visual impairment they caused. The IOLs underwent macroscopical examination, transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and electrophoresis for protein detection. Three unused control Hydroview IOLs served for comparison. RESULTS: Macroscopical examination showed a diffuse or localized grey-whitish opacification within the IOL optic. TEM confirmed the presence of lesions inside the optic in all the explanted IOLs and revealed 3 patterns of deep deposits: a) diffuse, thick, granular, electron-dense ones; b) small, thin, lattice-like ones, with prominent electron-lucent areas; and c) elongated electron-dense formations surrounded by electron-lucent halos. SEM showed surface deposits on four IOLs. EDS revealed oxygen and carbon in all IOLs and documented calcium, phosphorus, silicon and/or iron in the deposits. Two of the patients with iron in their IOLs had eye surgery prior to their phacoemulsification. Iron correlated well with the second TEM pattern of deep lesions, whereas calcium with the third TEM pattern. No protein bands were detected on electrophoresis. Control lenses did not show any ultrastructural or chemical abnormality. CONCLUSIONS: The present study supports the presence of chemical alterations inside the polymer of the optic in late postoperative opacification of Hydroview IOLs. This opacification does not follow a unique pathway but may present under different ultrastructular patterns depending on the responsible factors. Mechanical stress during surgery may initiate a sequence of events where ions such as calcium, phosphorus, silicon, and/or iron, participate in a biochemical cascade that leads to gradual alteration of the polymer network. Intraocular inflammation due to previous operation may be a factor inducing opacification through increase of iron-binding capacity in the aqueous humour. Calcification accounts only partially for the opacification noted in this type of IOL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). SETTING Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. DESIGN Prospective comparative observational study. METHODS Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. RESULTS Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). CONCLUSIONS Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare disk halo size in response to a glare source in eyes with an aspheric apodized diffractive multifocal intraocular lens (IOL) or aspheric monofocal IOL. SETTING: Rementeria Ophthalmological Clinic, Madrid, Spain. DESIGN: Prospective randomized masked study. METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in eyes that had cataract surgery and bilateral implantion of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were recorded. Monocular uncorrected distance visual acutity (UDVA) and corrected distance visual acuity (CDVA) were measured using high-contrast (96%) and low-contrast (10%) logMAR letter charts. RESULTS: The study comprised 39 eyes of 39 subjects (aged 70 to 80 years); 21 eyes had a multifocal IOL and 18 eyes a monofocal IOL. The mean halo radius was 35 arcmin larger in the multifocal IOL group than the monofocal group (P<.05). Greater halo effects were reported in the multifocal IOL group (P<.05). The mean monocular high-contrast UDVA and low-contrast UDVA did not vary significantly between groups, whereas the mean monocular high-contrast CDVA and low-contrast CDVA were significantly worse at 0.12 logMAR and 0.13 logMAR in the multifocal than in the monofocal IOL group, respectively (P <.01). A significant positive correlation was detected by multiple linear regression between the halo radius and low-contrast UDVA in the multifocal IOL group (r = 0.72, P<.001). CONCLUSIONS: The diffractive multifocal IOL gave rise to a larger disk halo size, which was correlated with a worse low-contrast UDVA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presbyopia is an age-related physiological condition that causes a gradual loss in the ability to focus on near objects, secondary to changes in zonular fibers, ciliary muscle and crystalline lens. Different surgical approaches are being pursued to surgically compensate presbyopia, such as corneal techniques or implantation of multifocal intraocular lenses (IOLs); however, their inability to restore accommodation has led to the development of single-optic positional accommodative IOLs. The axial shift, with the contraction of the ciliary muscle, of these IOLs increases the refractive power of the eye, improving the level of uncorrected near vision. Single-optic positional accommodative IOLs present few disturbances and larger ocular aberrations that improve near vision. However, reduced amplitudes of accommodation are obtained, little IOL shifts are measured and overall visual outcomes are limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The correction of presbyopia and restoration of true accommodative function to the ageing eye is the focus of much ongoing research and clinical work. A range of accommodating intraocular lenses (AIOLs) implanted during cataract surgery has been developed and they are designed to change either their position or shape in response to ciliary muscle contraction to generate an increase in dioptric power. Two main design concepts exist. First, axial shift concepts rely on anterior axial movement of one or two optics creating accommodative ability. Second, curvature change designs are designed to provide significant amplitudes of accommodation with little physical displacement. Single-optic devices have been used most widely, although the true accommodative ability provided by forward shift of the optic appears limited and recent findings indicate that alternative factors such as flexing of the optic to alter ocular aberrations may be responsible for the enhanced near vision reported in published studies. Techniques for analysing the performance of AIOLs have not been standardised and clinical studies have reported findings using a wide range of both subjective and objective methods, making it difficult to gauge the success of these implants. There is a need for longitudinal studies using objective methods to assess long-term performance of AIOLs and to determine if true accommodation is restored by the designs available. While dual-optic and curvature change IOLs are designed to provide greater amplitudes of accommodation than is possible with single-optic devices, several of these implants are in the early stages of development and require significant further work before human use is possible. A number of challenges remain and must be addressed before the ultimate goal of restoring youthful levels of accommodation to the presbyopic eye can be achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Editorial

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Premium intraocular lenses (IOLs) aim to surgically correct astigmatism and presbyopia following cataract extraction, optimising vision and eliminating the need for cataract surgery in later years. It is usual to fully correct astigmatism and to provide visual correction for distance and near when prescribing spectacles and contact lenses, however for correction with the lens implanted during cataract surgery, patients are required to purchase the premium IOLs and pay surgery fees outside the National Health Service in the UK. The benefit of using toric IOLs was thus demonstrated, both in standard visual tests and real-world situations. Orientation of toric IOLs during implantation is critical and the benefit of using conjunctival blood vessels for alignment was shown. The issue of centration of IOLs relative to the pupil was also investigated, showing changes with the amount of dilation and repeat dilation evaluation, which must be considered during surgery to optimize the visual performance of premium IOLs. Presbyopia is a global issue, of growing importance as life expectancy increases, with no real long-term cure. Despite enhanced lifestyles, changes in diet and improved medical care, presbyopia still presents in modern life as a significant visual impairment. The onset of presbyopia was found to vary with risk factors including alcohol consumption, smoking, UV exposure and even weight as well as age. A new technique to make measurement of accommodation more objective and robust was explored, although needs for further design modifications were identified. Due to dysphotopsia and lack of intermediate vision through most multifocal IOL designs, the development of a trifocal IOL was shown to minimize these aspects. The current thesis, therefore, emphasises the challenges of premium IOL surgery and need for refinement for optimum visual outcome in addition to outlining how premium IOLs may provide long-term and successful correction of astigmatism and presbyopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A standardised defocus area metric and reading performance index metric were devised for the evaluation of the range of focus and the reading ability of subjects implanted with presbyopic correcting IOLs. The range of clear vision after implantation of an MIOL is extended by a second focal point; however, this results in the prevalence of dysphotopsia. A bespoke halometer was designed and validated to assess this photopic phenomenon. There is a lack of standardisation in the methods used for determining IOL orientation and thus rotation. A repeatable, objective method was developed to allow the accurate assessment of IOL rotation, which was used to determine the rotational and positional stability of a closed loop haptic IOL. A new commercially available biometry device was validated for use with subjects prior to cataract surgery. The optical low coherence reflectometry instrument proved to be a valid method for assessing ocular biometry and covered a wider range of ocular parameters in comparison with previous instruments. The advantages of MIOLs were shown to include an extended range of clear vision translating into greater reading ability. However, an increased prevalence of dysphotopsia was shown with a bespoke halometer, which was dependent on the MIOL optic design. Implantation of a single optic accommodating IOL did not improve reading ability but achieved high subjective ratings of near vision. The closed-loop haptic IOL displayed excellent rotational stability in the late period but relatively poor rotational stability in the early period post implantation. The orientation error was compounded by the high frequency of positional misalignment leading to an extensive overall misalignment of the IOL. This thesis demonstrates the functionality of new IOL lens designs and the importance of standardised testing methods, thus providing a greater understanding of the consequences of implanting these IOLs. Consequently, the findings of the thesis will influence future designs of IOLs and testing methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A number of clinical techniques are available to assess the visual and optical performance of the eye. This report aims to review the advantages and limitations of techniques used in previous studies of patients implanted with intraocular lenses (IOLs), whose designs are ever increasing in optical complexity. Although useful, in-vitro measurements of IOL optical quality cannot account for the wide range of biological variation in ocular anatomy and corneal optics, which will impact on the visual outcome achieved. This further highlights the need for a standardised series of visual performance tests that can be applied to a wide range of IOL designs. The conclusions of this report intend to assistresearchers in developing a comprehensive series of investigations to evaluate IOL performance. Repeatable and reproducible in-vivo assessments of visual and optical performance are desirable to further develop IOL concepts and designs, in the hope of improving current postoperative visual satisfaction. © 2013 Nova Science Publishers, Inc.