881 resultados para Internal arteriovenous fistula


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A case of iatrogenic fistula from the right internal mammary artery to the subclavian vein following subclavian vein catheterization is reported. The patient had undergone percutaneous Intracath catheterization of the subclavian vein to treat hypovolemic shock during the surgical treatment of ectopic pregnancy. She had remained symptom-free for 7 years and then started to complain of effort dyspnea. The patient was found to have a thrill and a bruit at the subclavian region, and arteriography demonstrated a fistula between the right internal mammary artery and the subclavian vein. The fistula was successfully closed by embolization with a percutaneous detachable balloon catheter. © 1993.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The arteriovenous fistula (AVF) is characterized by enhanced blood flow and is the most widely used vascular access for chronic haemodialysis (Sivanesan et al., 1998). A large proportion of the AVF late failures are related to local haemodynamics (Sivanesan et al., 1999a). As in AVF, blood flow dynamics plays an important role in growth, rupture, and surgical treatment of aneurysm. Several techniques have been used to study the flow patterns in simplified models of vascular anastomose and aneurysm. In the present investigation, Computational Fluid Dynamics (CFD) is used to analyze the flow patterns in AVF and aneurysm through the velocity waveform obtained from experimental surgeries in dogs (Galego et al., 2000), as well as intra-operative blood flow recordings of patients with radiocephalic AVF ( Sivanesan et al., 1999b) and physiological pulses (Aires, 1991), respectively. The flow patterns in AVF for dog and patient surgeries data are qualitatively similar. Perturbation, recirculation and separation zones appeared during cardiac cycle, and these were intensified in the diastole phase for the AVF and aneurysm models. The values of wall shear stress presented in this investigation of AVF and aneurysm models oscillated in the range that can both cause damage to endothelial cells and develop atherosclerosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arteriovenous fistula involving renal artery and inferior vena cava are rare. We report the case of a 47-year-old woman with a chronic arteriovenous fistula between right renal artery and inferior vena cava due to a penetrating trauma. Another finding was a vena cava aneurysm caused by the fistula. The patient was successfully treated with a covered stent in the renal artery. Diagnosis and postoperative control have been documented with CT scan. Endovascular techniques may be effective and minimally invasive option for treatment and renal preservation in renal-cava arteriovenous fistulae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AVFs may be considered the best type of venous access for chronic hemodialysis in pediatric patients with more than 20 kg who are not likely to receive a kidney transplant or be transitioned to peritoneal dialysis within one yr. The aim of the study was to report the experience in the creation of AVFs in pediatric candidates for renal transplantation using microsurgical vascular techniques, with emphasis on the details of the surgical technique. Forty children underwent 50 fistula creations - 31 radial-cephalic, 11 brachial-cephalic, five brachial-basilic and three saphenous-femoral. The vein was anastomosed to the artery in an end-to-lateral fashion by using two separate 8/0 prolene running sutures. The overall patency rate was 76.0%:22 (70.9%) of the radial-cephalic fistulas, nine (81.8%) of the brachial-cephalic, five (100.0%) of the brachial-basilic and two (66.6%) of the saphenous-femoral. There was no significant difference in patency rates between the brachial-cephalic, brachial-basilic and radial-cephalic fistulas. The incidences of fistula patency were not different for patients weighing < 20 kg compared with patients weighing > 20 kg. AVF remains as a satisfactory method for providing hemodialysis in children. The utilization of microsurgical techniques with some technical refinements described herein permits the achievement of high fistula patency rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The perimedullary arteriovenous fistulas are located on the pial surface and are usually supplied by spinal medullary arteries, that is, either by the anterior or posterior spinal arteries, with no intervening nidus between the feeder arteries and the venous drainage. The clinical findings are, more commonly, caused by progressive radiculomedullary ischemic processes secondary to steal vascular mechanism. As the vascular supply to the spinal cord and to the arteriovenous fistulas (AVF) is not shared with one another, the vascular steal phenomenon cannot be implicated in this case`s physiopathology. Most probably, the mass effect caused by the giant venous dilatation was the pathophysiological mechanism involved in this lesion Case report The authors describe the case of a 6-year-old girl with an intradural ventral arteriovenous fistula, with a giant venous dilatation, fed directly by L2 and L3 radiculomedullary arteries at the conus medullaris. There was no arterial supply to the fistula from the anterior or posterior spinal arteries. Selective spinal angiography showed an arteriovenous fistula supplied directly by two radiculomedullary arteries, with a large draining vein caudally. Interposing the arterial and venous vessels was a giant venous aneurysmal dilatation located ventral to the conus medullaris and extending from L3 to T6. The patient was successfully treated by a surgical approach through a laminotomy from L3 to T11. Conclusion The type IV-C spinal arteriovenous malformations or perimedullary AVFs are rare lesions predominately described at the conus medullaris with various types of angio-architecture and controversial treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To determine the blood recirculation ratio in the vascular access of patients on hemodialysis, and to calculate the Kt/Vs obtained with the different techniques of arteriovenous fistula punctures. Materials and Methods. A total of 174 patients were divided according to the technique used for arteriovenous fistula puncture: group 1, needles in opposite directions and with a distance of 5 cm or more between them; group 2, needles in opposite directions but with a distance of less than 5 cm; group 3, unidirectional needles with both directed to the heart and with a distance of 5 cm or more; group 4, unidirectional needles but separated by a distance of less than 5 cm between needles; and group 5, patients carrying a temporary venous catheter. Blood samples were collected for urea analysis, pre and post-dialysis for Kt/V rate, and other samples for calculation of the access recirculation. Results. Group 1 presented the lowest rate of access recirculation (8.51 +/- 4.90%) and the best Kt/V (1.71 +/- 0.36), while group 4 presented the worst access recirculation (20.68 +/- 4.92%) and Kt/V (1.16 +/- 0.26). All groups differed significantly from group 4 (p < 0.05), except group 5 with regard for Kt/V parameter. Discussion. The technique of arteriovenous fistula puncture is an essential factor to decrease the access recirculation and assure better results of measurement of hemodialysis adequacy. On the basis of the results obtained, insertion of the needles in the same direction and with a distance of less than 5 cm between them should be avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the case of a 21-year-old male with high-output heart failure due to a femoral arteriovenous fistula caused by a firearm wound. A new balloon expandable stent covered with polytetrafluorethylene was implanted in the artery to occlude the arteriovenous fistula. The fistula was immediately occluded and the artery remained patent. On the following day, the patient felt much better, with no symptoms of heart failure. Additional follow-up is required to assure the usefulness of this less invasive procedure in the treatment of arteriovenous fistulas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the case of a 3-year-old female patient, who, since birth, had cyanosis difficult to explain with usual diagnostic tests. The only findings on physical examination were cyanosis and clubbing of her fingers. Chest computerized tomography showed images of excessive attenuation in the right lung, which resembled arteriovenous fistulae that were later confirmed on cardiac catheterization. The fistulous trajectories were then embolized with 7 Gianturco coils, which resulted in an immediate increase in the arterial saturation of blood oxygen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM OF THE STUDY: To analyse the course of upper limb edema in patients with an arteriovenous fistula used for dialysis and to analyse the available therapeutic options. STUDY DESIGN: Retrospective study of patients with this type of edema, who were treated in our institution from 1992 to 1996. PATIENTS AND METHODS: Seven consecutive patients with an arterioveinous fistula treated for edema of the upper extremity, were reviewed. The fistula was created at the elbow in 6 patients and at the forearm in 1. The edema appeared immediately after operation in 4 patients and after a delay in 3 patients. Stenosis (3 patients) or occlusion (2 patients) of the subclavian vein was documented in 5 patients who were investigated by angiography. RESULTS: The edema regressed spontaneously in 4 patients because collaterals developed in 3 patients, and the fistula thrombosed in 1 patient. Surgical intervention allowed regression of the edema in the other 3 patients: excessive output of the fistula was reduced in 2 patients and an axillojugular bypass was performed in 1 patient. The fistula remained effective in 6 patients. Another fistula was performed on the contralateral arm in 1 patient. CONCLUSION: Non-operative management is recommended in patients who develop edema immediately after creation of the fistula, because spontaneous regression is likely. Measures aimed at reducing the output of the fistula or enhancing the venous capacities of the arm are required when edema appears at a later stage. The fistula can be saved in the majority of cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapport de Synthèse : Introduction : Depuis plus de 50 ans, les fistules artérioveineuses radiocéphaliques (FAV) restent le meilleur accès d'hémodialyse en termes de perméabilité et de complications. Néanmoins, l'échec précoce dû aux thromboses ou à la non maturation entraîne leur abandon chez un nombre significatif de patients. Cette étude prospective est destinée à investiguer la mesure peropératoire du débit sanguin dans les FAV comme valeur prédictive d'échec précoce. Méthode : Nous avons sélectionné des patients nécessitant la confection d'une FAV pour hémodialyse en se basant sur le repérage veineux effectué par ultrason dans la période préopératoire. La mesure du débit sanguin dans la FAV a été réalisée systématiquement après la réalisation de l'anastomose en utilisant une sonde mesurant le temps de transit des globules rouges. Durant le suivi, le débit a été estimé par ultrason à des intervalles réguliers. Résultats : Nous avons réalisés 58 FAV chez 58 patients avec un suivi moyen de 30 jours. La thrombose et non maturation a été observée chez 8 patients (14%) et 4 patients (7%) respectivement. La valeur de débit peropératoire des fistules sans échec précoce était significativement plus élevée que dans les fistules avec échec précoce (230 v. 98 mL/min ; Ρ = 0.007), tout comme à une semaine (753 vs 228 mL/min ; P=0.0008) et 4 semaines (915 vs 245 mL/min, P<0.0001j. La mesure du débit avec une valeur seuil à 120 mL/min présente une sensibilité de 67%, une spécificité de 75% et une valeur prédictive positive de 91%. Conclusions : Un débit sanguin < 120mL/min a une bonne valeur prédictive positive d'échec précoce dans les FAV. Durant la procédure, cette valeur seuil, doit être utilisée pour sélectionner de manière appropriée les FAV nécessitant durant la même intervention une correction immédiate afin d'améliorer le débit. Une étude consécutive devra investiguer les origines des débits faibles des FAV objectivés durant leur confection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy. DESIGN: A retrospective study over a 20-month period from a single centre. PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included. METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage. RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation. CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: An upper limb arteriovenous (AV) fistula is the access of choice for haemodialysis (HD). There have been few reports of saphenofemoral AV fistulas (SFAVF) over the last 10-20 years because of previous suggestions of poor patencies and needling difficulties. Here, we describe our clinical experience with SFAVF.Methods: SFAVFs were evaluated using the following variables: immediate results, early and late complications, intraoperative and postoperative complications (up to day 30), efficiency of the fistula after the onset of needling and complications associated to its use.Results: Fifty-six SFAVF fistulas were created in 48 patients. Eight patients had two fistulas: 8 patent (16%), 10 transplanted (20%), 12 deaths (24%), 1 low flow (2%) and 20 thrombosis (39%) (first two months of preparation). One patient had severe hypotension during surgery, which caused thrombosis of the fistula, which was successfully thrombectomised, four thrombosed fistulae were successfully thrombectomised and revised on the first postoperative day. After 59 months of follow-up, primary patency was 44%.Conclusion: SFAVF is an adequate alternative for patients without the possibility for other access in the upper limbs, allowing efficient dialysis with good long-term patency with a low complication rate.