905 resultados para Interfragmentary Motion
Resumo:
Most forms of tissue healing depend critically on revascularisation. In soft tissues and in vitro, mechanical stimuli have been shown to promote vessel-forming activity. However, in bone defects, increased interfragmentary motion impairs vascular regeneration. Because these effects seem contradictory, we aimed to determine whether a range of mechanical stimuli exists in which angiogenesis is favoured. A series of cyclic strain magnitudes were applied to a Matrigel-based “tube formation” assay and the total lengths of networks formed by human microvascular endothelial cells measured at 24 h. Network lengths were reduced at all strain levels, compared to unstretched controls. However, the levels of pro-angiogenic matrix metalloproteases-2 and -9 in the corresponding conditioned media were unchanged by strain, and vascular endothelial growth factor was uniformly elevated in stretched conditions. By repeating the assay with the addition of conditioned media from mesenchymal stem cells cultivated in similar conditions, paracrine stimuli were shown to increase network lengths, but not to alter the negative effect of cyclic stretching. Together, these results demonstrate that directly applied periodic strains can inhibit endothelial organisation in vitro, and suggest that this may be due to physical disruption rather than biochemical modulation. Most importantly, the results indicate that the straining of endothelial cells and their assembly into vascular-like structures must be studied simultaneously to adequately characterise the mechanical influence on vessel formation.
Resumo:
Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.
Resumo:
BACKGROUND Trans-olecranon chevron osteotomies (COs) remain the gold standard surgical approach to type C fractures of the distal humerus. This technique is associated with a high complication rate and development of an extra-articular olecranon osteotomy may be advantageous. The aim of this study was to compare the load to failure of COs with extra-articular oblique osteotomies (OOs) as well as modified, extra-articular step osteotomies (SOs). METHODS These three osteotomies and their subsequent fixation utilizing a standardized tension band wiring technique were tested in 42 composite analog ulnae models at 20° and 70° of flexion. Triceps loading was simulated with a servo hydraulic testing machine. All specimens were isometrically loaded until failure. Kinematic and force data, as well as interfragmentary motion were recorded. RESULTS At 70°, CO failed at a mean load of 963N (SD 104N), the OO at 1512N (SD 208N) and the SO at 1484N (SD 153N), (P<0.001). At 20°, CO failed at a mean load of 707N (SD 104N) and OO at 1009N (SD 85N) (P=0.006). The highest load to failure was observed for the SO, which was 1277N (SD 172N). The load to failure of the SO was significantly higher than the CO as well as the OO. CONCLUSION Extra-articular osteotomies showed a significantly higher load to failure in comparison to traditional CO. At near full extension (20° of flexion), this biomechanical advantage was further enhanced by a step-cut modification of the extra-articular oblique osteotomy.
Resumo:
Person tracking systems to date have either relied on motion detection or optical flow as a basis for person detection and tracking. As yet, systems have not been developed that utilise both these techniques. We propose a person tracking system that uses both, made possible by a novel hybrid optical flow-motion detection technique that we have developed. This provides the system with two methods of person detection, helping to avoid missed detections and the need to predict position, which can lead to errors in tracking and mistakes when handling occlusion situations. Our results show that our system is able to track people accurately, with an average error less than four pixels, and that our system outperforms the current CAVIAR benchmark system.
Resumo:
In sport and exercise biomechanics, forward dynamics analyses or simulations have frequently been used in attempts to establish optimal techniques for performance of a wide range of motor activities. However, the accuracy and validity of these simulations is largely dependent on the complexity of the mathematical model used to represent the neuromusculoskeletal system. It could be argued that complex mathematical models are superior to simple mathematical models as they enable basic mechanical insights to be made and individual-specific optimal movement solutions to be identified. Contrary to some claims in the literature, however, we suggest that it is currently not possible to identify the complete optimal solution for a given motor activity. For a complete optimization of human motion, dynamical systems theory implies that mathematical models must incorporate a much wider range of organismic, environmental and task constraints. These ideas encapsulate why sports medicine specialists need to adopt more individualized clinical assessment procedures in interpreting why performers' movement patterns may differ.
Resumo:
Although placing reflective markers on pedestrians’ major joints can make pedestrians more conspicuous to drivers at night, it has been suggested that this “biological motion” effect may be reduced when visual clutter is present. We tested whether extraneous points of light affected the ability of 12 younger and 12 older drivers to see pedestrians as they drove on a closed road at night. Pedestrians wore black clothing alone or with retroreflective markings in four different configurations. One pedestrian walked in place and was surrounded by clutter on half of the trials. Another was always surrounded by visual clutter but either walked in place or stood still. Clothing configuration, pedestrian motion, and driver age influenced conspicuity but clutter did not. The results confirm that even in the presence of visual clutter pedestrians wearing biological motion configurations are recognized more often and at greater distances than when they wear a reflective vest.
Resumo:
3D Motion capture is a medium that plots motion, typically human motion, converting it into a form that can be represented digitally. It is a fast evolving field and recent inertial technology may provide new artistic possibilities for its use in live performance. Although not often used in this context, motion capture has a combination of attributes that can provide unique forms of collaboration with performance arts. The inertial motion capture suit used for this study has orientation sensors placed at strategic points on the body to map body motion. Its portability, real-time performance, ease of use, and its immunity from line-of-sight problems inherent in optical systems suggest it would work well as a live performance technology. Many animation techniques can be used in real-time. This research examines a broad cross-section of these techniques using four practice-led cases to assess the suitability of inertial motion capture to live performance. Although each case explores different visual possibilities, all make use of the performativity of the medium, using either an improvisational format or interactivity among stage, audience and screen that would be difficult to emulate any other way. A real-time environment is not capable of reproducing the depth and sophistication of animation people have come to expect through media. These environments take many hours to render. In time the combination of what can be produced in real-time and the tools available in a 3D environment will no doubt create their own tree of aesthetic directions in live performance. The case study looks at the potential of interactivity that this technology offers.