28 resultados para Interchangeability
Resumo:
Introduction. Epilepsy is a condition characterized by signs and symptoms of neurological disorder. Lamotrigine has been widely used, mainly due to their greater tolerability and lower rate of drug interactions with other antiepileptic drugs however the newest antiepileptic drugs have high cost to patient. In Brazil there are three different sort of pharmaceutical equivalents (reference, generic and similar), and the Brazilian health care authorities offers to users the possibility to receive them free of charge. Moreover these pharmaceutical equivalents can change during the treatment of epilepsy because this authorities buy the cheapest by public tender two or three times a year. Aim. To evaluate the clinical and laboratory findings related to the most frequently used therapeutic equivalents of lamotrigine (reference drugs and similar products). Patients and methods. Two similar formulations (A and B) and one reference (C) were tested in nine epileptic refractory patients. The study was divided into three periods of 42 days, one for each formulation, and medical data about the frequency of seizures, the occurrence of side effects and measurement of plasma concentrations of lamotrigine were collected. Results. The average number of seizures/week and plasma concentration of lamotrigine for formulations A, B and C were not statistically significant differences. Three patients during the use of the formulation C presented mild and transitory side effects. Conclusion. Similar or reference drugs showed satisfactory results, however the interchangeability among the formulations raise the difficulty for the management of seizures in refractory epilepsy.
Resumo:
Epilepsy is the most common serious neurological disorder worldwide. Approximately 70% of patients with epilepsy have their seizures controlled by clinical and pharmacological treatment. This research evaluated the possible influence of interchangeability among therapeutic equivalents of LTG on the clinical condition and quality of life of refractory epileptic patients. The study was divided into three periods of 42 days, and an equivalent therapeutic LTG randomly dispensed for each period (two similars - formulations A and B, and the reference product - formulation C). The mean dose of LTG was 5.5 mg/kg/day. The presence of side effects tends to have a greater deleterious effect on quality of life of refractory epileptics compared to variations in number of seizures or changes in plasma concentrations. The results showed that independently of the drug prescribed, interchangeability among therapeutic equivalents can negatively impact epilepsy control.
Resumo:
Epilepsy is the most common serious neurological disorder worldwide. Approximately 70% of patients with epilepsy have their seizures controlled by clinical and pharmacological treatment. This research evaluated the possible influence of interchangeability among therapeutic equivalents of LTG on the clinical condition and quality of life of refractory epileptic patients. The study was divided into three periods of 42 days, and an equivalent therapeutic LTG randomly dispensed for each period (two similars - formulations A and B, and the reference product - formulation C). The mean dose of LTG was 5.5 mg/kg/day. The presence of side effects tends to have a greater deleterious effect on quality of life of refractory epileptics compared to variations in number of seizures or changes in plasma concentrations. The results showed that independently of the drug prescribed, interchangeability among therapeutic equivalents can negatively impact epilepsy control.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
The exchange of a prescribed drug by other similar, by generic products and even by custom products has become common practice in our country, often ignoring basic tenets of bioequivalence, interchangeability, stability and characteristics of the pharmaceutical compounds. In the case of drugs of narrow therapeutic index, such as levothyroxine, these problems are intensified, putting the effectiveness of treatment and patient health at serious risk. We review the pertinent legislation, emphasizing the characteristics of levothyroxine and adverse effects that limit the interchangeability of the compound.
Resumo:
Support for interoperability and interchangeability of software components which are part of a fieldbus automation system relies on the definition of open architectures, most of them involving proprietary technologies. Concurrently, standard, open and non-proprietary technologies, such as XML, SOAP, Web Services and the like, have greatly evolved and been diffused in the computing area. This article presents a FOUNDATION fieldbus (TM) device description technology named Open-EDD, based on XML and other related technologies (XLST, DOM using Xerces implementation, OO, XMIL Schema), proposing an open and nonproprietary alternative to the EDD (Electronic Device Description). This initial proposal includes defining Open-EDDML as the programming language of the technology in the FOUNDATION fieldbus (TM) protocol, implementing a compiler and a parser, and finally, integrating and testing the new technology using field devices and a commercial fieldbus configurator. This study attests that this new technology is feasible and can be applied to other configurators or HMI applications used in fieldbus automation systems. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.
Resumo:
[ANGLÈS] This project introduces GNSS-SDR, an open source Global Navigation Satellite System software-defined receiver. The lack of reconfigurability of current commercial-of-the-shelf receivers and the advent of new radionavigation signals and systems make software receivers an appealing approach to design new architectures and signal processing algorithms. With the aim of exploring the full potential of this forthcoming scenario with a plurality of new signal structures and frequency bands available for positioning, this paper describes the software architecture design and provides details about its implementation, targeting a multiband, multisystem GNSS receiver. The result is a testbed for GNSS signal processing that allows any kind of customization, including interchangeability of signal sources, signal processing algorithms, interoperability with other systems, output formats, and the offering of interfaces to all the intermediate signals, parameters and variables. The source code release under the GNU General Public License (GPL) secures practical usability, inspection, and continuous improvement by the research community, allowing the discussion based on tangible code and the analysis of results obtained with real signals. The source code is complemented by a development ecosystem, consisting of a website (http://gnss-sdr.org), as well as a revision control system, instructions for users and developers, and communication tools. The project shows in detail the design of the initial blocks of the Signal Processing Plane of the receiver: signal conditioner, the acquisition block and the receiver channel, the project also extends the functionality of the acquisition and tracking modules of the GNSS-SDR receiver to track the new Galileo E1 signals available. Each section provides a theoretical analysis, implementation details of each block and subsequent testing to confirm the calculations with both synthetically generated signals and with real signals from satellites in space.
Resumo:
Introduction: As part of the roadside development along the Interstate Highway System, the Iowa State Highway Commission has constructed eight pair of rest area facilities. Furthermore, two pair are presently under construction with an additional two pair proposed for letting in 1967. An additional nine and one-half pairs of rest areas are in the planning phase, a grand total of 45 rest Brea buildings. The facilities existing were planned and designed in a relatively short period of time. The rest area facilities are unusual in terms of water use, water demand rates, and the fact that there are no applicable guidelines from previous installations. Such facilities are a pioneering effort to furnish a service -which the travelling public desires and will use. The acceptance and current use of the existing facilities shows that the rest areas do provide a service the public will use and appreciate. The Iowa State Highway Commission is to be congratulated for this· pioneering effort. However there are problems, as should be expected when design of a new type of facility has no past operating experience to use as a guide. Another factor which enters is that a rest area facility is quite different and rather unrelated to engineering in the highway field of practice. Basically, the problems encountered can be resolved into several areas, namely 1) maintenance problems in equipment due to 2) insufficient capacity of several other elements of the water systems, and 3) no provisions for water quality control. This study and report is supposed to essentially cover the review of the rest areas, either existing and under construction or letting. However, the approach used has been somewhat different. Several basic economically feasible water system schemes have been developed which are· adaptable to the different well capacities and different water qualities encountered. These basic designs are used as a guide in recommending modifications to the existing rest area water systems, anticipating that the basic designs will be used for future facilities. The magnitude of the problems involved is shown by the fact that the projected water use and demand variations of each rest area building is equivalent to the water supply for a community of about 100 people. The problems of proper operation and maintenance of an eventual thirty to forty-five such facilities are gigantic. For successful operation the rest area water systems must have a high degree of standardization and interchangeability of all elements of the water systems, even if it means a limited degree of over-design in some rest area facilities.
Resumo:
Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.
Resumo:
PURPOSE: Slight physiological differences between acute exposure in normobaric hypoxia (NH) and hypobaric hypoxia (HH) have been reported. Taken together, these differences suggest different physiological responses to hypoxic exposure to a simulated altitude (NH) versus a terrestrial altitude (HH). For this purpose, in the present study, we aimed to directly compare the time-trial performance after acute hypoxia exposure (26 h, 3450 min) by the same subjects under three different conditions: NH, HH, and normobaric normoxia (NN). Based on all of the preceding studies examining the differences among these hypoxic conditions, we hypothesized greater performance impairment in HH than in NH. METHODS: The experimental design consisted of three sessions: NN (Sion: FiO2, 20.93), NH (Sion, hypoxic room: FiO2, 13.6%; barometric pressure, 716 mm Hg), and HH (Jungfraujoch: FiO2, 20.93; barometric pressure, 481 mm Hg). The performance was evaluated at the end of each session with a cycle time trial of 250 kJ. RESULTS: The mean time trial duration in NN was significantly shorter than under the two hypoxic conditions (P < 0.001). In addition, the mean duration in NH was significantly shorter than that in HH (P < 0.01). The mean pulse oxygen saturation during the time trial was significantly lower for HH than for NH (P < 0.05), and it was significantly higher in NN than for the two other sessions (P < 0.001). CONCLUSION: As previously suggested, HH seems to be a more stressful stimulus, and NH and HH should not be used interchangeability when endurance performance is the main objective. The principal factor in this performance difference between hypoxic conditions seemed to be the lower peripheral oxygen saturation in HH at rest, as well as during exercise.
Resumo:
El proceso administrativo y de compras de OPL Carga tiene algunas falencias entre ellas: fallas en la Comunicación entre el personal operativo, no se realizan llamadas internas usando con frecuencia el email, produciendo la saturación de solicitudes las cuales terminan sin ser resueltas en cuanto a roles se refiere, no hay enfoque de procesos en vista que no se tiene claras las tareas de cada cargo, adicionalmente no hay claridad en los subprocesos, perjudicando el proceso con el aumento de costos, pérdida de tiempo, las responsabilidades de los funcionario no todas las veces se ejecutan en el tiempo asignado, el liderazgo compartido presenta ambigüedades. Objetivos: Definir el trabajo en equipo en el proceso administrativo y de compras en OPL carga de Bucaramanga. La investigación que a realizar es de tipo descriptivo, busca descubrir las falencias o características que permiten diseñar y desarrollar un modelo de solución para los problemas del equipo de OPL Carga S.A.S. Materiales y métodos: La investigación efectuada es de tipo descriptivo, el objetivo es definir el modelo del trabajo en equipo y describir las falencias en el proceso administrativo y de compras en OPL carga de Bucaramanga, que permitan obtener un diagnóstico integral que conlleve a la implementación de estrategias de solución. Resultados: Se identificaron las falencias en los siguientes aspectos: Variable comunicación, rendimiento, destrezas complementarias, propósito significativo y meta específicas de los funcionarios en OPL carga sección administrativa. Conclusiones: El modelo de trabajo en equipo que OPL aplica es jerárquico, en el que se ofrece estabilidad, seguridad, se toman decisiones en forma piramidal, mediante la planeación de tareas, la colaboración, igualdad y respeto por los miembros, trabajando en pro de la solución de problemas. Se construyó un plano conceptual que permitió exponer la interpretación que la estudiante tiene de las teorías, investigaciones y antecedentes válidos para la comprensión del problema investigado. Área comunicacional: Coordinar acciones tendientes para que los funcionarios respondan a tiempo los emails atenientes a su trabajo. Área condiciones de trabajo: Clarificar y diseñar las reglas de comportamiento al interior de los equipos de trabajo que redunden en el mejoramiento del mismo y la búsqueda de soluciones oportunas. Área metas específicas: Procurar mediante auditorías el cumplimiento de las metas y objetivos propuestos por cada equipo de trabajo.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Sociais - FFC
Resumo:
The increasing demand for alternative fuels lead to the search for solutions to use these fuels in old equipments and bring for new equipments the necessity of alternative fuels based burners. As a solution for these necessity the Gas Interchangeability`s studies came in evidence, because it studies the possibility of changing one fuel for another without changing the initial condition. In integrated industries, as most of steel industries, there is a link between process, the byproducts of one process are used as fuel for other process. There are new conditions for the equipments, that will be developed for these fuels, but even in these industries there will be situations which the byproduct won`t be available, and the process cannot stop. Using the gas interchangeability`s concepts is possible to work with security in both cases. Using alternative fuels in fossil fuel based burners and having a back-up solution for new technology burner. But using these new solutions were verified that there are some cases which the interchangeability`s methods does not work with satisfactory results, and for this reason, this study came to develop a new concept for the Method of Wobbe Index to evaluate the possibility to increase the range of the satisfactory results