929 resultados para Infrasound and low frequency noise-exposure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Vibroacoustic disease (VAD) is a systematic pathology characterized by the abnormal growth of extra-cellular matrices in the absence of infl ammatory processes, namely collagen and elastin, both of which are abundant in the basement membrane zone of the vocal folds. VAD can develop due to long-term exposure to infrasound and low-frequency noise (ILFN, <500 Hz). Mendes et al. (2006, 2008 and 2012) revealed that ILFN-exposed males and females presented an increased fundamental frequency (F0), decreased jitter %, and reduced maximum phonation frequency range, when compared with normative data. Temporal measures of maximum phonation time and S/Z ratio were generally reduced. Study Aims: Herein, the same voice acoustic parameters of 48 males, 36 airline pilots and 12 cabin crewmembers (age range 25-60 years) were studied, and the effects and interaction of age and years of ILFN exposure were investigated within those parameters. ILFN-exposure time (i.e. years of professional activity) ranged from 3.5 to 36 years. Materials and Methods: Spoken and sung phonatory tasks were recorded with a DA-P1 Tascam DAT and a C420III PP AKG head-worn microphone, positioned at 3 cm from the mouth. Acoustic analyses were performed using KayPENTAX Computer Speech Lab and Multi-Dimensional Voice Program. Results: Results revealed that even though pilots and cabin crewmembers were exposed to occupational environments with distinct (ILFN-rich) acoustical frequency distributions and sound pressure levels, differences in the vocal acoustic parameters were not evident. Analyzing data from both professional groups (N = 48) revealed that F0 increased signifi cantly with the number of years of professional activity. Conclusion: These results strongly suggest that the number of years of professional activity (i.e. total ILFN exposure time) had a signifi cant effect on F0. Furthermore, they may refl ect the histological changes specifi cally observed on the vocal folds of ILFN-exposed professionals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Long-term exposure to infrasound and low frequency noise (ILFN <500 Hz, including infrasound) can lead to the development of vibroacoustic disease (VAD). VAD is a systemic pathology characterized by the abnormal growth of extracellular matrices in the absence of inflammatory processes, namely of collagen and elastin, both of which are abundant in the basement membrane zone of the vocal folds. ILFN-exposed workers include pilots, cabin crewmembers, restaurant workers, ship machinists and, in previous studies, even though they did not present vocal symptoms, ILFN-exposed workers had significant different voice acoustic patterns (perturbation and temporal measures) when compared with normative population. Study Aims: The present study investigates the effects of age and years of occupational ILFN-exposure on voice acoustic parameters of 37 cabin crewmembers: 12 males and 25 females. Specifically, the goals of this study are to: 1) Verify if acoustic parameters change over the age and years of ILFN-exposure and 2) Determine if there is any interaction between age and years of ILFNexposure on voice acoustic parameters of crewmembers. Materials and Methods: Spoken phonatory tasks were recorded with a C420III PP AKG head-worn microphone and a DA-P1 Tascam DAT. Acoustic analyses were performed using KayPENTAX Computer Speech Lab and Multi-Dimensional Voice Program. Acoustic parameters included speaking fundamental frequency, perturbation measures (jitter, shimmer and harmonicto- noise ratio), temporal measures (maximum phonation time and s/z ratio) and voice tremor frequency. Results: One-way ANOVA analysis revealed that as the number of ILFN-exposure years increased male cabin crewmembers presented significant different shimmer values of /i/ as well as tremor frequency of /u/. Females presented significantly different jitter % of /i, a, O/ (p <0.05). Lastly, Two-way ANOVA analysis revealed that for females, there was a significant interaction between age and occupational ILFN-exposure for voice acoustic parameters, namely for jitter’s mean for /a, O/ and shimmer’s (%) mean for /a, i/ (p <0.05). Discussion and Conclusion: These perturbation measure patterns may be indicative of histological changes within the vocal folds as a result of ILFN-exposure. The results of this study suggest that voice acoustic analysis may be an important tool for confirming ILFN-induced health effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of the titanium nitride (TIN) gate electrode thickness has been investigated in n and p channel SOI multiple gate field effect transistors (MuGFETs) through low frequency noise charge pumping and static measurements as well as capacitance-voltage curves The results suggest that a thicker TIN metal gate electrode gives rise to a higher EOT a lower mobility and a higher interface trap density The devices have also been studied for different back gate biases where the GIFBE onset occurs at lower front-gate voltage for thinner TIN metal gate thickness and at higher V(GF) In addition it is demonstrated that post deposition nitridation of the MOCVD HfSiO gate dielectric exhibits an unexpected trend with TIN gate electrode thickness where a continuous variation of EOT and an increase on the degradation of the interface quality are observed (C) 2010 Elsevier Ltd All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proceedings Institute of Acoustics (UK); vol. 25, nº2, p. 72-78.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Discussing urban planning requires rethinking sustainability in cities and building healthy environments. Historically, some aspects of advancing the urban way of life have not been considered important in city planning. This is particularly the case where technological advances have led to conflicting land use, as with the installation of power poles and building electrical substations near residential areas. This research aims to discuss and rethink sustainability in cities, focusing on the environmental impact of low-frequency noise and electromagnetic radiation on human health. It presents data from a case study in an urban space in northern Portugal, and focuses on four guiding questions: Can power poles and power lines cause noise? Do power poles and power lines cause discomfort? Do power poles and power lines cause discomfort due to noise? Can power poles and power lines affect human health? To answer these questions, we undertook research between 2014 and 2015 that was comprised of two approaches. The first approach consisted of evaluating the noise of nine points divided into two groups â near the sourceâ (e.g., up to 50 m from power poles) and â away from the sourceâ (e.g., more than 250 m away from the source). In the second approach, noise levels were measured for 72 h in houses located up to 20 m from the source. The groups consist of residents living within the distance range specified for each group. The measurement values were compared with the proposed criteria for assessing low-frequency noise using the DEFRA Guidance (University of Salford). In the first approach, the noise caused discomfort, regardless of the group. In the second approach, the noise had fluctuating characteristics, which led us to conclude that the noise caused discomfort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For many years, RF and analog integrated circuits have been mainly developed using bipolar and compound semiconductor technologies due to their better performance. In the last years, the advance made in CMOS technology allowed analog and RF circuits to be built with such a technology, but the use of CMOS technology in RF application instead of bipolar technology has brought more issues in terms of noise. The noise cannot be completely eliminated and will therefore ultimately limit the accuracy of measurements and set a lower limit on how small signals can be detected and processed in an electronic circuit. One kind of noise which affects MOS transistors much more than bipolar ones is the low-frequency noise. In MOSFETs, low-frequency noise is mainly of two kinds: flicker or 1/f noise and random telegraph signal noise (RTS). The objective of this thesis is to characterize and to model the low-frequency noise by studying RTS and flicker noise under both constant and switched bias conditions. The effect of different biasing schemes on both RTS and flicker noise in time and frequency domain has been investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-frequency noise in an electrolyte-insulator- semiconductor (EIS) structure functionalized with multilayers of polyamidoamine (PAMAM) dendrimer and single-walled carbon nanotubes (SWNT) is studied. The noise spectral density exhibits 1/f(gamma) dependence with the power factor of gamma approximate to 0.8 and gamma = 0.8-1.8 for the bare and functionalized EIS sensor, respectively. The gate-voltage noise spectral density is practically independent of the pH value of the solution and increases with increasing gate voltage or gate-leakage current. It has been revealed that functionalization of an EIS structure with a PAMAM/SWNTs multilayer leads to an essential reduction of the 1/f noise. To interpret the noise behavior in bare and functionalized EIS devices, a gate-current noise model for capacitive EIS structures based on an equivalent flatband-voltage fluctuation concept has been developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Transcutaneous electrical nerve stimulation (TENS) is an effective adjunctive therapy for postoperative pain; however, effects of different frequencies Of stimulation have not been systematically investigated. Laparoscopic sterilization (LS) causes significant pain in the early postoperative period and requires substantial postoperative medication. Therefore, we studied the effects of TENS on postoperative pain after LS through placement of Yoon fallopian rings in a prospective, randomized, double-blinded, and placebo-controlled study. Methods: Sixty-four patients undergoing LS for uterine tube ligation were randomly allocated to receive either active TENS or placebo TENS. Postoperative pain was evaluated using a standard I I-point numeric rating scale and the McGill Pain Questionnaire (MPQ)-pain rating index and number of words chosen. Both high frequency (100 Hz) and low frequency (4 Hz) TENS, at strong, but comfortable sensory intensity, were applied for 20 minutes through 4 electrodes placed around the surgical incision immediately after Surgery. Pain was assessed before and after application of TENS when patients were at postanesthesia care unit (PACU). Results: Both high and low frequency TENS significantly decreased postoperative pain intensity when compared with before administration of TENS using the numeric rating scale (P = 0.001), pain rating index (P = 0.001), and number of words chosen (P 0.001) compared with placebo TENS (P = 0.001). TENS in combination with standard pharmacologic analgesic treatment was efficacious for postoperative pain relief after LS. Conclusions: We recommend regular use of multimodal therapy with TENS and analgesic drugs after LS with placement of Yoon rings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatitis B virus (HBV) molecular profiles were determined for 44 patients who were infected with human immunodeficiency virus (HIV) type 1 and had antibodies to the hepatitis B core antigen (anti-HBc), with and without other HBV serological markers. In this population, 70% of the patients were under lamivudine treatment as a component of antiretroviral therapy. HBV DNA was detected in 14 (32%) patients. Eight out of 12 (67%) HBsAg positive samples, 3/10 (30%) anti-HBc only samples, and 3/22 (14%) anti-HBs positive samples were HBV DNA positive. HBV DNA loads, measured by real time polymerase chain reaction, were much higher in the HBsAg positive patients (mean, 2.5 × 10(9) copies/ml) than in the negative ones (HBV occult infection; mean, 2.7 × 10(5) copies/ml). Nine out of the 14 HBV DNA positive patients were under lamivudine treatment. Lamivudine resistant mutations in the polymerase gene were detected in only three patients, all of them belonging to the subgroup of five HBsAg positive, HBV DNA positive patients. A low mean HBV load (2.7 × 10(5) copies/ml) and an absence of lamivudine resistant mutations were observed among the cases of HBV occult infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments have been performed using a simplified, Newtonian forced, global circulation model to investigate how variability of the tropospheric jet can be characterized by examining the combined fluctuations of the two leading modes of annular variability. Eddy forcing of this variability is analyzed in the phase space of the leading modes using the vertically integrated momentum budget. The nature of the annular variability and eddy forcing depends on the time scale. At low frequencies the zonal flow and baroclinic eddies are in quasi equilibrium and anomalies propagate poleward. The eddies are shown primarily to reinforce the anomalous state and are closely balanced by the linear damping, leaving slow evolution as a residual. At high frequencies the flow is strongly evolving and anomalies are initiated on the poleward side of the tropospheric jet and propagate equatorward. The eddies are shown to drive this evolution strongly: eddy location and amplitude reflect the past baroclinicity, while eddy feedback on the zonal flow may be interpreted in terms of wave breaking associated with baroclinic life cycles in lateral shear.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Starting from the classical Saltzman two-dimensional convection equations, we derive via a severe spectral truncation a minimal 10 ODE system which includes the thermal effect of viscous dissipation. Neglecting this process leads to a dynamical system which includes a decoupled generalized Lorenz system. The consideration of this process breaks an important symmetry and couples the dynamics of fast and slow variables, with the ensuing modifications to the structural properties of the attractor and of the spectral features. When the relevant nondimensional number (Eckert number Ec) is different from zero, an additional time scale of O(Ec−1) is introduced in the system, as shown with standard multiscale analysis and made clear by several numerical evidences. Moreover, the system is ergodic and hyperbolic, the slow variables feature long-term memory with 1/f3/2 power spectra, and the fast variables feature amplitude modulation. Increasing the strength of the thermal-viscous feedback has a stabilizing effect, as both the metric entropy and the Kaplan-Yorke attractor dimension decrease monotonically with Ec. The analyzed system features very rich dynamics: it overcomes some of the limitations of the Lorenz system and might have prototypical value in relevant processes in complex systems dynamics, such as the interaction between slow and fast variables, the presence of long-term memory, and the associated extreme value statistics. This analysis shows how neglecting the coupling of slow and fast variables only on the basis of scale analysis can be catastrophic. In fact, this leads to spurious invariances that affect essential dynamical properties (ergodicity, hyperbolicity) and that cause the model losing ability in describing intrinsically multiscale processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-frequency multipath is still one of the major challenges for high precision GPS relative positioning. In kinematic applications, mainly, due to geometry changes, the low-frequency multipath is difficult to be removed or modeled. Spectral analysis has a powerful technique to analyze this kind of non-stationary signals: the wavelet transform. However, some processes and specific ways of processing are necessary to work together in order to detect and efficiently mitigate low-frequency multipath. In this paper, these processes are discussed. Some experiments were carried out in a kinematic mode with a controlled and known vehicle movement. The data were collected in the presence of a reflector surface placed close to the vehicle to cause, mainly, low-frequency multipath. From theanalyses realized, the results in terms of double difference residuals and statistical tests showed that the proposed methodology is very efficient to detect and mitigate low-frequency multipath effects. © 2008 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Myocardium damage during Chagas' disease results from the immunological imbalance between pro-and production of anti-inflammatory cytokines and has been explained based on the Th1-Th2 dichotomy and regulatory T cell activity. Recently, we demonstrated that IL-17 produced during experimental T. cruzi infection regulates Th1 cells differentiation and parasite induced myocarditis. Here, we investigated the role of IL-17 and regulatory T cell during human Chagas' disease. Methodology/Principal Findings: First, we observed CD4(+)IL-17(+) T cells in culture of peripheral blood mononuclear cells (PBMC) from Chagas' disease patients and we evaluated Th1, Th2, Th17 cytokine profile production in the PBMC cells from Chagas' disease patients (cardiomyopathy-free, and with mild, moderate or severe cardiomyopathy) cultured with T. cruzi antigen. Cultures of PBMC from patients with moderate and severe cardiomyopathy produced high levels of TNF-alpha, IFN-gamma and low levels of IL-10, when compared to mild cardiomyopathy or cardiomyopathy-free patients. Flow cytometry analysis showed higher CD4(+)IL-17(+) cells in PBMC cultured from patients without or with mild cardiomyopathy, in comparison to patients with moderate or severe cardiomyopathy. We then analyzed the presence and function of regulatory T cells in all patients. All groups of Chagas' disease patients presented the same frequency of CD4(+)CD25(+) regulatory T cells. However, CD4(+)CD25(+) T cells from patients with mild cardiomyopathy or cardiomyopathy-free showed higher suppressive activity than those with moderate and severe cardiomyopathy. IFN-gamma levels during chronic Chagas' disease are inversely correlated to the LVEF (P = 0.007, r = -0.614), while regulatory T cell activity is directly correlated with LVEF (P = 0.022, r = 0.500). Conclusion/Significance: These results indicate that reduced production of the cytokines IL-10 and IL-17 in association with high levels of IFN-gamma and TNF-alpha is correlated with the severity of the Chagas' disease cardiomyopathy, and the immunological imbalance observed may be causally related with deficient suppressor activity of regulatory T cells that controls myocardial inflammation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: As a previous study revealed, arts speech therapy (AST) affects cardiorespiratory interaction [1]. The aim of the present study was to investigate whether AST also has effects on brain oxygenation and hemodynamics measured non-invasively using near-infrared spectroscopy (NIRS). Material and methods: NIRS measurements were performed on 17 subjects (8 men and 9 women, mean age: 35.6 ± 12.7 y) during AST. Each measurement lasted 35 min, comprising 8 min pre-baseline, 10 min recitation and 20 min post-baseline. For each subject, measurements were performed for three different AST recitation tasks (recitation of alliterative, hexameter and prose verse). Relative concentration changes of oxyhemoglobin (Δ[O2Hb]) and deoxyhemoglobin (Δ[HHb]) as well as the tissue oxygenation index (TOI) were measured using a Hamamatsu NIRO300 NIRS device and a sensor placed on the subjects forehead. Movement artifacts were removed using a novel method [2]. Statistical analysis (Wilcoxon test) was applied to the data to investigate (i) if the recitation causes changes in the median values and/or in the Mayer wave power spectral density (MW-PSD, range: 0.07–0.13 Hz) of Δ[O2Hb], Δ[HHb] or TOI, and (ii) if these changes vary between the 3 recitation forms. Results: For all three recitation styles a significant (p < 0.05) decrease in Δ[O2Hb] and TOI was found, indicating a decrease in blood flow. These decreases did not vary significantly between the three styles. MW-PSD increased significantly for Δ[O2Hb] when reciting the hexameter and prose verse, and for Δ[HHb] and TOI when reciting alliterations and hexameter, representing an increase in Mayer waves. The MW-PSD increase for Δ[O2Hb] was significantly larger for the hexameter verse compared to alliterative and prose verse Conclusion: The study showed that AST affects brain hemodynamics (oxygenation, blood flow and Mayer waves). Recitation caused a significant decrease in cerebral blood flow for all recitation styles as well as an increase in Mayer waves, particularly for the hexameter, which may indicate a sympathetic activation. References 1. D. Cysarz, D. von Bonin, H. Lackner, P. Heusser, M. Moser, H. Bettermann. Am J Physiol Heart Circ Physiol, 287 (2) (2004), pp. H579–H587 2. F. Scholkmann, S. Spichtig, T. Muehlemann, M. Wolf. Physiol Meas, 31 (5) (2010), pp. 649–662