981 resultados para Infrared surface exams
Resumo:
We demonstrate surface plasmon resonance (SPR) fiber devices based upon ultraviolet inscription of a grating-type structure into both single-layered and multilayered thin films deposited on the flat side of a lapped D-shaped fiber. The single-layered devices were fabricated from germanium, while the multilayered ones comprised layers of germanium, silica, and silver. Some of the devices operated in air with high coupling efficiency in excess of 40 dB and an estimated index sensitivity of Delta lambda/Delta n = 90 mn from 1 to 1.15 index range, while others provided an index sensitivity of Delta lambda/Delta n = 6790 mn for refractive indices from 1.33 to 1.37. (C) 2009 Optical Society of America
Resumo:
We demonstrate the use of tilted fiber gratings to assist with the generation of infrared surface plasmons on a metal film coating the flat of a D-shaped fiber. The wavelength of the strong (>25 dB) resonance is tunable over similar to 1000 nm by adjusting the polarization state of the light and is highly sensitive to the refractive index of any aqueous medium surrounding the fiber (sensitivity= 3365 nm).
Resumo:
We demonstrate the use of tilted fiber gratings to assist the generation of localized infrared surface plasmons with short propagation lengths and a sensitivity of d lambda/dn = 3365 nm in the aqueous index regime. It was also found that the resonances could be spectrally tuned over 1000 nm at the same spatial region with high coupling efficiency (in excess of 25 dB) by altering the polarization of the light illuminating the device.
Resumo:
We demonstrate the use of tilted fiber gratings to assist the generation of localized infrared surface Plasmons with short propagation lengths and a sensitivity of dλ/dn = 3365 nm in the aqueous index regime. It was also found that the resonances could be spectrally tuned over 1000 nm at the same spatial region with high coupling efficiency (in excess of 25 dB) by altering the polarization of the light illuminating the device. © 2007 Optical Society of America.
Resumo:
This paper focusses on the study of the underdrawings of 16th century easel paintings attributed to the workshop of the Portuguese-Flemish Master Frei Carlos. This investigation encompasses multidisciplinary research that relates the results of surface exams (infrared reflectography, standard light photography and infrared photography) with analytical investigations. The surface analysis of Frei Carlos’ underdrawings by infrared reflectography has shown heterogeneous work, revealing two different situations: (1) an abundant and expressive underdrawing, revealing a Flemish influence and (2) a simple and outlined underdrawing. This preliminary research raised an important question related to this Portuguese-Flemish workshop and to the analytical approach: Is the underdrawing's heterogeneity, as observed in the reflectograms, related to different artists or is this rather an effect that is produced due to the use of different materials in the underdrawing's execution? Consequently, if different materials were used, how can we have access to the hidden underdrawings? In order to understand the reasons for this dissemblance, chemical analysis of micro-samples collected in underdrawing areas and representing both situations were carried out by optical microscopy, micro Fourier transform infrared spectroscopy (μ-FTIR), scanning electron microscopy coupled with energy dispersive X-ray spectrometry (SEM-EDX) and micro-Raman spectroscopy (μ-Raman). Taking into account the different possibilities and practical and theoretical limitations of surface and punctual examinations in the study of easel painting underdrawings, the methodology of research was adjusted, sometimes resulting in a re-analysis of experimental results. This research shows the importance of combining multispectral surface exams and chemical analysis in the understanding of the artistic creative processes of 16th century easel paintings.
Resumo:
Este trabalho de investigação centra-se no contributo dos exames de superfície e nas análises micro-analíticas no estudo de vinte e uma pinturas atribuídas à oficina de Frei Carlos, um dos grandes Mestres Luso-Flamengos ativos em território Nacional durante a primeira metade do século XVI. A "Pintura Luso-Flamenga" é uma expressão comummente usada na história da pintura Portuguesa do primeiro terço do século XVI e no seu sentido mais básico designa o trabalho de mestres flamengos que se instalaram em Portugal durante o reinado de D. Manuel I (1495- 1521) contribuindo decisivamente para o processo de renovação da pintura Portuguesa na época. O estudo integrado combina a pesquisa histórica em fontes documentais com exames de superfície e de caracterização material das obras de arte. O estudo material das pinturas foi realizado através de microscopia ótica, microscopia de infravermelhos com transformada de Fourier, espectroscopia de micro-Raman, microscopia eletrónica de varrimento acoplada com espectrometria de energia dispersiva de raios X, micro- difração de raios-X, cromatografia líquida de alta eficiência e pirólise acoplada à cromatografia gasosa /espectrometria de massa. Esta investigação envolveu técnicas complementares de análise de superfície e de ponto no estudo técnico e material das preparações, imprimitura, desenho subjacente, camadas pictóricas e sucessões estratigráficas, dando a conhecer os materiais utilizados na execução técnica das pinturas e evidenciando especificidades técnicas da produção artística. Este estudo pretende inclusivamente evidenciar alguns detalhes técnicos do artista que possivelmente estão relacionados com a herança das práticas Flamengas. O conhecimento de algumas particularidades da técnica deste Mestre também permitiu estabelecer comparações com duas pinturas que haviam sido atribuídas, com algumas reservas, a esta oficina de pintura Luso-Flamenga. Mais recentemente, como resultado de um estudo colaborativo, foi realizada uma ampla campanha de reflectografia infravermelhos, introduzindo novos dados acerca da execução técnica do desenho subjacente, o que contribuiu para diferenciar, nestas duas pinturas, outra "mão", atribuída então a um seguidor de Frei Carlos. Esta investigação introduz um novo e profundo conhecimento sobre a Oficina de Frei Carlos, permitindo estabelecer comparações com a obra do seu seguidor e com uma pintura também atribuída a esta oficina e que incorpora o Museu da National Gallery (NG5594), evidenciando os materiais utilizados na técnica de produção artística e especificidades técnicas aliadas aos processos criativos/ construtivos que permitem estabelecer os pontos de contacto e de diferenciação entre estas obras; Varieties and styles in the works attributed to Frei Carlos - new perspectives Abstract: This investigation is focused on the contributions of surface exams and micro-analytical research in the study of twenty one paintings attributed to Frei Carlos workshop, one of the most important Portuguese-Flemish painters active in our country during the first half of sixteen Century. "Portuguese-Flemish Painting" is a common expression used in the history of Portuguese painting of the first third of the sixteenth century and in its most basic meaning designates the work of Flemish masters who settled in Portugal during the reign of King Manuel I (1495-1521) contributing decisively to the process of renewal of Portuguese painting at the time. The integrated approach combines historical research on documental sources with surface examination and material characterization of the paintings by using state-of-art analytical techniques. Microanalysis was carried out by optical microscopy, micro-Fourier-transform infrared-spectroscopy, micro-Raman spectroscopy, scanning electron microscopy coupled with energy dispersive X-ray spectrometry, micro-X-ray diffraction analysis, high performance liquid chromatography and Pyrolysis gas chromatography mass spectrometry. This complementary surface and analytical research was involved in the technical and material characterization of grounds, underdrawings, primings, paint layers and its multi-layered build-up, providing access to the painter´s materials used in the technical execution of the paintings and details of the technique of artistic production. This study also intends to expose some usual details of the artist’s technique which are possibly related to the Master´s Flemish influence. The knowledge of some particularities of the Master´s technique also allowed a new comparison with two paintings that had been attributed with some reserves to this Portuguese-Flemish workshop. More recently, as a result of a collaborative study, an extensive infrared reflectography campaign was made, giving new data concerning underdrawings technical execution and contributing to differentiate, in these two paintings, another “hand”, attributed to a follower of Frei Carlos. Complementary analytical research also added a new and deep insight into Frei Carlos workshop, his follower and a panel that still attributed to Frei Carlos workshop that integrates the National Gallery´s Museum (NG5594), evidencing the materials used in technical production, their models and sources of artistic inspiration, techniques and pictorial construction procedures that could specifically relate or distinguish between them.
Resumo:
UNLABELLED: Cleavage of influenza virus hemagglutinin (HA) by host cell proteases is necessary for viral activation and infectivity. In humans and mice, members of the type II transmembrane protease family (TTSP), e.g., TMPRSS2, TMPRSS4, and TMPRSS11d (HAT), have been shown to cleave influenza virus HA for viral activation and infectivityin vitro Recently, we reported that inactivation of a single HA-activating protease gene,Tmprss2, in knockout mice inhibits the spread of H1N1 influenza viruses. However, after infection ofTmprss2knockout mice with an H3N2 influenza virus, only a slight increase in survival was observed, and mice still lost body weight. In this study, we investigated an additional trypsin-like protease, TMPRSS4. Both TMPRSS2 and TMPRSS4 are expressed in the same cell types of the mouse lung. Deletion ofTmprss4alone in knockout mice does not protect them from body weight loss and death upon infection with H3N2 influenza virus. In contrast,Tmprss2(-/-)Tmprss4(-/-)double-knockout mice showed a remarkably reduced virus spread and lung pathology, in addition to reduced body weight loss and mortality. Thus, our results identified TMPRSS4 as a second host cell protease that, in addition to TMPRSS2, is able to activate the HA of H3N2 influenza virusin vivo IMPORTANCE: Influenza epidemics and recurring pandemics are responsible for significant global morbidity and mortality. Due to high variability of the virus genome, resistance to available antiviral drugs is frequently observed, and new targets for treatment of influenza are needed. Host cell factors essential for processing of the virus hemagglutinin represent very suitable drug targets because the virus is dependent on these host factors for replication. We reported previously thatTmprss2-deficient mice are protected against H1N1 virus infections, but only marginal protection against H3N2 virus infections was observed. Here we show that deletion of two host protease genes,Tmprss2andTmprss4, strongly reduced viral spread as well as lung pathology and resulted in increased survival after H3N2 virus infection. Thus, TMPRSS4 represents another host cell factor that is involved in cleavage activation of H3N2 influenza virusesin vivo.
Resumo:
The parameters for the newly discovered open cluster Alessi 95 are established on the basis of available photometric and spectroscopic data, in conjunction with new observations. Colour excesses for spectroscopically observed B- and A-type stars near SU Cas follow a reddening relation described by E(U-B)/E(B-V) = 0.83 + 0.02E(B-V), implying a value of R=AV/E(B-V) ? 2.8 for the associated dust. Alessi 95 has a mean reddening of E(B-V)(B0) = 0.35 +/- 0.02 s.e., an intrinsic distance modulus of V0-MV= 8.16 +/- 0.04 s.e. (+/- 0.21 s.d.), d= 429 +/- 8 pc, and an estimated age of 108.2 yr from zero-age main sequence (ZAMS) fitting of available UBV, CCD BV, NOMAD, and Two Micron All Sky Survey JHKs observations of cluster stars. SU Cas is a likely cluster member, with an inferred space reddening of E(B-V) = 0.33 +/- 0.02 and a luminosity of < MV >=-3.15 +/- 0.07 s.e., consistent with overtone pulsation (PFM= 2.75 d), as also implied by the Cepheids light-curve parameters, rate of period increase and Hipparcos parallaxes for cluster stars. There is excellent agreement of the distance estimates for SU Cas inferred from cluster ZAMS fitting, its pulsation parallax derived from the infrared surface brightness technique and Hipparcos parallaxes, which all agree to within a few per cent.
Resumo:
The Sea and Land Surface Temperature Radiometer (SLSTR) is a nine channel visible and infrared high precision radiometer designed to provide climate data of global sea and land surface temperatures. The SLSTR payload is destined to fly on the Ocean and Medium-Resolution Land Mission for the ESA/EU Global Monitoring for Environment and Security (GMES) Programme Sentinel-3 mission to measure the sea and land temperature and topography for near real-time environmental and atmospheric climate monitoring of the Earth. In this paper we describe the optical layout of infrared optics in the instrument, spectral thin-film multilayer design, and system channel throughput analysis for the combined interference filter and dichroic beamsplitter coatings to discriminate wavelengths at 3.74, 10.85 & 12.0 μm. The rationale for selection of thin-film materials, deposition technique, and environmental testing, inclusive of humidity, thermal cycling and ionizing radiation testing are also described.
Resumo:
We show that retrievals of sea surface temperature from satellite infrared imagery are prone to two forms of systematic error: prior error (familiar from the theory of atmospheric sounding) and error arising from nonlinearity. These errors have different complex geographical variations, related to the differing geographical distributions of the main geophysical variables that determine clear-sky brightness-temperatures over the oceans. We show that such errors arise as an intrinsic consequence of the form of the retrieval (rather than as a consequence of sub-optimally specified retrieval coefficients, as is often assumed) and that the pattern of observed errors can be simulated in detail using radiative-transfer modelling. The prior error has the linear form familiar from atmospheric sounding. A quadratic equation for nonlinearity error is derived, and it is verified that the nonlinearity error exhibits predominantly quadratic behaviour in this case.
Resumo:
The retrieval (estimation) of sea surface temperatures (SSTs) from space-based infrared observations is increasingly performed using retrieval coefficients derived from radiative transfer simulations of top-of-atmosphere brightness temperatures (BTs). Typically, an estimate of SST is formed from a weighted combination of BTs at a few wavelengths, plus an offset. This paper addresses two questions about the radiative transfer modeling approach to deriving these weighting and offset coefficients. How precisely specified do the coefficients need to be in order to obtain the required SST accuracy (e.g., scatter <0.3 K in week-average SST, bias <0.1 K)? And how precisely is it actually possible to specify them using current forward models? The conclusions are that weighting coefficients can be obtained with adequate precision, while the offset coefficient will often require an empirical adjustment of the order of a few tenths of a kelvin against validation data. Thus, a rational approach to defining retrieval coefficients is one of radiative transfer modeling followed by offset adjustment. The need for this approach is illustrated from experience in defining SST retrieval schemes for operational meteorological satellites. A strategy is described for obtaining the required offset adjustment, and the paper highlights some of the subtler aspects involved with reference to the example of SST retrievals from the imager on the geostationary satellite GOES-8.
Resumo:
The time dependence of the concentration of CO2 in an electrochemical thin layer cavity is studied with Fourier transform infrared spectroscopy (FTIR) in order to evaluate the extent to which the thin layer cavity is diffusionally decoupled from the surrounding bulk electrolyte. For the model system of CO on Pt(111) in 0.1 M HClO4, it is found that the concentration of CO2, formed by electro-oxidation of CO, equilibrates rapidly with the surrounding bulk electrolyte. This rapid equilibration indicates that there is diffusion out of the thin layer, even on the short time scales of typical infrared experiments (1-3 min). However, since the measured CO2 absorbance intensity as a function of time is reproducible to within 10%, a new time-dependent method for surface coverage calibration using solution-phase species is proposed.
Resumo:
The oscillatory electro-oxidation of methanol was studied by means of in situ infrared (IR) spectroscopy in the attenuated total reflection (ATR) configuration using a platinum film on a Si prism as working electrode. The surface-enhanced infrared absorption (SEIRA) effect considerably improves the spectroscopic resolution, allowing at following the coverage of some adsorbing species during the galvanostatic oscillations. Carbon monoxide was the main adsorbed specie observed in the induction period and within the oscillatory regime. The system was investigated at two distinct time-scales and its dynamics characterized accordingly. During the induction period the main transformation observed as the system move through the phase space towards the oscillatory region was the decrease of the coverage of adsorbed carbon, coupled to the increase of the electrode potential. Similar transition characterizes the evolution within the oscillatory region, but at a considerably slower rate. Experiments with higher time resolution revealed that the electrode potential oscillates in-phase with the frequency of the linearly adsorbed CO vibration and that the amount of adsorbed CO oscillates with small amplitude. Adsorbed formate was found to play, if any, a very small role. Results are discussed and compared with other systems. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This study aims to determine the entrance surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence (TL) dosimetry. Twenty seven radiologic exams of dogs of different breed and sizes were performed. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO(4):Dy) produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN). The entrance surface skin dose range evaluated in this type of procedure was between 0.43 mGy to small size dogs and 4.22 mGy to big size dogs with repeated exams. The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (C) 2010 Elsevier Ltd. All rights reserved.