983 resultados para Indoor environment
Resumo:
Atmospheric pollutants can have serious impacts on the preservation of São Paulo's tangible cultural heritage. The purpose of this paper is to report the results of a monitoring campaign focussed on particulate matter (PM) that was conducted in three of the most important museums of the São Paulo megacity (Brazil): the Museu de Arqueologia e Etnologia (MAE-USP), the Museu Paulista (MP-USP), and the Pinacoteca do Estado de São Paulo (PE). These museums exhibit indoor PM and black carbon (BC) concentrations consistent with their urban locations and their specific methods for managing the indoor environment.
Resumo:
Intelligent buildings should provide a multi-sensory experience so that visual, aural, tactile, olfactory and gustatory senses are stimulated appropriately. A lack of environmental stimuli produces a boring and unsatisfying environment. It is now known that the environment affects people at deeper levels than, say, health and safety, and consequently it can modify moods and work performance. A holistic approach is proposed which recognizes that the physical environment together with social, organizational and personal factors can enhance the productivity of occupants. This approach provides a footprint for the design of healthier and more sustainable workplaces.
Resumo:
A wireless sensor network (WSN) is a group of sensors linked by wireless medium to perform distributed sensing tasks. WSNs have attracted a wide interest from academia and industry alike due to their diversity of applications, including home automation, smart environment, and emergency services, in various buildings. The primary goal of a WSN is to collect data sensed by sensors. These data are characteristic of being heavily noisy, exhibiting temporal and spatial correlation. In order to extract useful information from such data, as this paper will demonstrate, people need to utilise various techniques to analyse the data. Data mining is a process in which a wide spectrum of data analysis methods is used. It is applied in the paper to analyse data collected from WSNs monitoring an indoor environment in a building. A case study is given to demonstrate how data mining can be used to optimise the use of the office space in a building.
Resumo:
People's interaction with the indoor environment plays a significant role in energy consumption in buildings. Mismatching and delaying occupants' feedback on the indoor environment to the building energy management system is the major barrier to the efficient energy management of buildings. There is an increasing trend towards the application of digital technology to support control systems in order to achieve energy efficiency in buildings. This article introduces a holistic, integrated, building energy management model called `smart sensor, optimum decision and intelligent control' (SMODIC). The model takes into account occupants' responses to the indoor environments in the control system. The model of optimal decision-making based on multiple criteria of indoor environments has been integrated into the whole system. The SMODIC model combines information technology and people centric concepts to achieve energy savings in buildings.
Resumo:
Buildings consume a large amount of energy, in both their use and production. Retrofitting aims to achieve a reduction in this energy consumption. However, there are concerns that retrofitting can cause negative impacts on the internal environment including poor thermal comfort and health issues. This research investigates the impact of retrofitting the façade of existing traditional buildings and the resulting impact on the indoor environment and occupant thermal comfort. A Case building located at the University of Reading has been monitored experimentally and modelled using IES software with monitored values as input conditions for the model. The proposed façade related retrofit options have been simulated and provide information on their effect on the indoor environment. The findings show a positive impact on the internal environment. The data shows a 16.2% improvement in thermal comfort after retrofit is simulated. This also achieved a 21.6% reduction in energy consumption from the existing building.
Resumo:
This paper presents the implementation of a modified particle filter for vision-based simultaneous localization and mapping of an autonomous robot in a structured indoor environment. Through this method, artificial landmarks such as multi-coloured cylinders can be tracked with a camera mounted on the robot, and the position of the robot can be estimated at the same time. Experimental results in simulation and in real environments show that this approach has advantages over the extended Kalman filter with ambiguous data association and various levels of odometric noise.
Resumo:
This thesis examines the spatial and temporal variation in nitrogen dioxide (NO2) levels in Guernsey and the impacts on pre-existing asthmatics. Whilst air quality in Guernsey is generally good, the levels of NO2 exceed UK standards in several locations. The evidence indicates that people suffering from asthma have exacerbation of their symptoms if exposed to elevated levels of air pollutants including NO2, although this research has never been carried out in Guernsey before. In addition, exposure assessment of individuals is rarely carried out and research in this area is limited due to the complexity of undertaking such a study, which will include a combination of exposures in the home, the workplace and ambient exposures, which vary depending on the individual daily experience. For the first time in Guernsey, this research has examined NO2 levels in correlation with asthma patient admissions to hospital, assessment of NO2 exposures in typical homes and typical workplaces in Guernsey. The data showed a temporal correlation between NO2 levels and the number of hospital admissions and the trend from 2008-2012 was upwards. Statistical analysis of the data did not show a significant linear correlation due to the small size of the data sets. Exposure assessment of individuals showed a spatial variation in exposures in Guernsey and assessment in indoor environments showed that real-time analysis of NO2 levels needs to be undertaken if indoor micro environments for NO2 are the be assessed adequately. There was temporal and spatial variation in NO2 concentrations measured using diffusion tubes, which provide a monthly mean value, and analysers measuring NO2 concentrations in real time. The research shows that building layout and design are important factors for good air flow and ventilation and the dispersion of NO2 indoors. Environmental Health Officers have statutory responsibilities for ambient air quality, hygiene of buildings and workplace environments and this role needs to be co-ordinated with healthcare professionals to improve health outcomes for asthmatics. The outcome of the thesis was the development of a risk management framework for pre-existing asthmatics at work for use by regulators of workplaces and an information leaflet to assist in improving health outcomes for asthmatics in Guernsey.
Resumo:
El efecto de la frecuencia portadora sobre los valores propios de los sistemas MIMO (multiple-input multiple-output) es investigado experimentalmente en un entorno indoor, considerando condiciones de línea de vista (LOS: line-of-sight) y sin línea de vista (NLOS: non-line-of-sight). Los resultados muestran una reducción en la potencia media de los valores propios del sistema MIMO, lo cual es debido a un incremento en la correlación espacial entre los sub-canales cuando la frecuencia portadora se incrementa. Este efecto causa una reducción en la capacidad del sistema MIMO.
Resumo:
A physiological experiment was carried out in a naturally ventilated, non-HVAC indoor environment of a spacious experimental room. More than 300 healthy university students volunteered for this study. The purpose of the study was to investigate the human physiological indicators which could be used to characterise the indoor operative temperature changes in a building and their impact on human thermal comfort based on the different climatic characteristics people would experience in Chongqing, China. The study found that sensory nerve conduction velocity (SCV) could objectively provide a good indicator for assessment of the human response to changes in indoor operative temperatures in a naturally ventilated situation. The results showed that with the changes in the indoor operative temperatures, the changing trend in the nerve conduction velocity was basically the same as that of the skin temperature at the sensory nerve measuring segment (Tskin(scv)). There was good coherent consistency among the factors: indoor operative temperature, SCV and Tskin(scv) in a certain indoor operative temperature range. Through self-adaptation and self-feedback regulation, the human physiological indicators would produce certain adaptive changes to deal with the changes in indoor operative temperature. The findings of this study should provide the baseline data to inform guidelines for the development of thermal environment-related standards that could contribute to efficient use of energy in buildings in China.
Resumo:
Three-dimensional computational simulations are performed to examine indoor environment and micro-environment around human bodies in an office in terms of thermal environment and air quality. In this study, personal displacement ventilation (PDV), including two cases with all seats taken and two middle seats taken, is compared with overall displacement ventilation (ODV) of all seats taken under the condition that supply temperature is 24℃ and air change rate is 60 l/s per workstation. When using PDV, temperature stratification, the characteristic of displacement ventilation, is obviously observed at the position of occupant’s head and clearer in the case with all seats taken. Verticalertical ertical temperature temperature temperature temperature temperature differences below height of the head areare under under under 2℃ in two cases in two cases in two cases in two cases in two cases in two cases in two cases in two cases with all seats taken,and the temperature with PDV is higher than that with ODV. Verticalertical ertical temperature temperature temperature temperature temperature temperature difference is under 3 under 3under 3 under 3℃ in the case in the case in the case in the case in the case in the case in the case with two middle seats taken. CO2 concentration is lower th is lower th is lower this lower this lower than 2 g/man 2 g/m an 2 g/man 2 g/man 2 g/man 2 g/m 3 in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. The results indicate that PDV can be used in the room with big change of occupants’ number to satisfy the need of thermal comfort and air quality. When not all seats are taken, designers should increase supply air requirement or reduce its temperature for thermal comfort. INDEX TERMS
Resumo:
Introdução e objetivo: A exposição à luz natural tem efeitos relevantes no sistema de temporização biológica. Pode-se supor que essa exposição poderia promover um ajuste melhor entre os ritmos biológicos e os horários de início de trabalho entre trabalhadores diurnos de ambientes externos. O objetivo deste estudo foi comparar a matutinidade/vespertinidade e a relação entre o horário de trabalho real e o ideal em trabalhadores diurnos expostos a condições de iluminação distintas. Métodos: O estudo foi conduzido com dois grupos de trabalhadores (n=49) que residiam em uma área rural e tinham condições sociais similares. Um grupo trabalhava em ambiente interno (n=20, idade média 30,8 anos (21-50); desvio padrão=9,8) e o outro grupo trabalhava em ambiente externo (n=29, idade média 30,8 anos (17- 50); desvio padrão=10,0). Os trabalhadores preencheram um questionário de matutinidade/vespertinidade (MEQ). Foi realizada uma ANOVA de um fator com o intuito de comparar os escores do MEQ entre os dois grupos de trabalhadores. Resultados: Como esperado, o Grupo do Ambiente Externo (GAE) apresentou média de escores mais elevada que o Grupo do Ambiente Interno (GAI), o que significa uma tendência à matutinidade (GAE: 58,4±7,9; GAI; 47,4±6,4), com significância estatística (F=26,22; p<0,001). De acordo com os dados relatados em relação aos horários de trabalho, o GAE gostaria de atrasar seu horário de trabalho em 31 minutos, em média, enquanto que o GAI gostaria de atrasar em 96 minutos seu horário de trabalho (F=7,71; p<0,01). Conclusões: Os resultados desse estudo sugerem que a exposição à luz natural pode promover um ajuste melhor aos horários de início de trabalho matutinos
Resumo:
Preliminary study of insects associated to indoor body decay in Colombia. This is the first report studying insects associated to indoor body decay process of a white pig (Sus scrofa) (Artiodactyla, Suidae) in a controlled indoor environment in an urban area of Florencia city, Amazonia Piedmont, Colombia. For a period of 54 days, 9,220 individuals (immature and adults), distributed in 3 orders, 5 families, 10 genera, and 10 species were collected using entomological nets and tweezers. Five decaying stages are described (fresh, bloated, active decay, advanced decay and remains). During the fresh stage we recorded Cochliomyia macellaria (Fabricius, 1775), Chrysomya albiceps (Wiedemann, 1819), Ophyra aenescens (Wiedemann, 1830), Oxysarcodexia sp., Lepidodexia sp. and Lasiophanes sp.; during the bloating stage C. macellaria, C. albiceps, Lucilia eximia (Wiedemann, 1819), Hemilucillia semidiaphana (Rondani, 1850), Musca domestica Linnaeus, 1758, O. aenescens, Oxysarcodexia sp., Lepidodexia sp., Dermestes maculatus De Geer, 1774 and Lasiphanes sp.; during the active decay C. macellaria, C. albiceps, L. eximia, M. domestica, O. aenescens, Lepidodexia sp. D. maculatus and Lasiophanes sp.; during the advanced decay C. macellaria, C. albiceps, M. domestica, Lepidodexia sp. and Lasiophanes sp.; and during the remains stage C. albiceps, D. maculatus and Lasiophanes sp. The insects were sorted out in 3 ecological categories; necrophagous, predators and parasites and sarco-saprophagous. According to Chao and Jack estimators, total richness was observed on day 20, with 100% of the expected species.
Resumo:
A single-feed rectangular-ring microstrip antenna is proposed for indoor communication under the Bluetooth protocol. The dimensions of the antenna together with the location of the feed point are optimized through field simulations in order to cover the Bluetooth bandwidth and to avoid linear polarization. The performance and the efficiency of the antenna are illustrated in a real indoor environment