960 resultados para Indoor and outdoor air
Resumo:
A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.
Resumo:
The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m(-3)]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16A degrees C and above 25A degrees C caused a reduction in the concentration (CFU m(-3)) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.
Resumo:
A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.
Resumo:
An investigation was undertaken to determine the chemical characterization of inhalable particulate matter in the Houston area, with special emphasis on source identification and apportionment of outdoor and indoor atmospheric aerosols using multivariate statistical analyses.^ Fine (<2.5 (mu)m) particle aerosol samples were collected by means of dichotomous samplers at two fixed site (Clear Lake and Sunnyside) ambient monitoring stations and one mobile monitoring van in the Houston area during June-October 1981 as part of the Houston Asthma Study. The mobile van allowed particulate sampling to take place both inside and outside of twelve homes.^ The samples collected for 12-h sampling on a 7 AM-7 PM and 7 PM-7 AM (CDT) schedule were analyzed for mass, trace elements, and two anions. Mass was determined gravimetrically. An energy-dispersive X-ray fluorescence (XRF) spectrometer was used for determination of elemental composition. Ion chromatography (IC) was used to determine sulfate and nitrate.^ Average chemical compositions of fine aerosol at each site were presented. Sulfate was found to be the largest single component in the fine fraction mass, comprising approximately 30% of the fine mass outdoors and 12% indoors, respectively.^ Principal components analysis (PCA) was applied to identify sources of aerosols and to assess the role of meteorological factors on the variation in particulate samples. The results suggested that meteorological parameters were not associated with sources of aerosol samples collected at these Houston sites.^ Source factor contributions to fine mass were calculated using a combination of PCA and stepwise multivariate regression analysis. It was found that much of the total fine mass was apparently contributed by sulfate-related aerosols. The average contributions to the fine mass coming from the sulfate-related aerosols were 56% of the Houston outdoor ambient fine particulate matter and 26% of the indoor fine particulate matter.^ Characterization of indoor aerosol in residential environments was compared with the results for outdoor aerosols. It was suggested that much of the indoor aerosol may be due to outdoor sources, but there may be important contributions from common indoor sources in the home environment such as smoking and gas cooking. ^
Resumo:
The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91 per cent of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30 per cent of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m−3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19 per cent higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m−3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70 per cent) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations
Resumo:
Introdução e objetivo: A exposição à luz natural tem efeitos relevantes no sistema de temporização biológica. Pode-se supor que essa exposição poderia promover um ajuste melhor entre os ritmos biológicos e os horários de início de trabalho entre trabalhadores diurnos de ambientes externos. O objetivo deste estudo foi comparar a matutinidade/vespertinidade e a relação entre o horário de trabalho real e o ideal em trabalhadores diurnos expostos a condições de iluminação distintas. Métodos: O estudo foi conduzido com dois grupos de trabalhadores (n=49) que residiam em uma área rural e tinham condições sociais similares. Um grupo trabalhava em ambiente interno (n=20, idade média 30,8 anos (21-50); desvio padrão=9,8) e o outro grupo trabalhava em ambiente externo (n=29, idade média 30,8 anos (17- 50); desvio padrão=10,0). Os trabalhadores preencheram um questionário de matutinidade/vespertinidade (MEQ). Foi realizada uma ANOVA de um fator com o intuito de comparar os escores do MEQ entre os dois grupos de trabalhadores. Resultados: Como esperado, o Grupo do Ambiente Externo (GAE) apresentou média de escores mais elevada que o Grupo do Ambiente Interno (GAI), o que significa uma tendência à matutinidade (GAE: 58,4±7,9; GAI; 47,4±6,4), com significância estatística (F=26,22; p<0,001). De acordo com os dados relatados em relação aos horários de trabalho, o GAE gostaria de atrasar seu horário de trabalho em 31 minutos, em média, enquanto que o GAI gostaria de atrasar em 96 minutos seu horário de trabalho (F=7,71; p<0,01). Conclusões: Os resultados desse estudo sugerem que a exposição à luz natural pode promover um ajuste melhor aos horários de início de trabalho matutinos
Resumo:
Sporotrichosis is a subcutaneous mycosis and is also a zoonosis (sapro- and anthropozoonosis). The objective of the present study was to determine the occurrence of sporotrichosis in domestic cats and in wild or exotic felines in captivity through the isolation of Sporothrix spp. from claw impressions in a culture medium. The samples included 132 felines, of which 120 (91.0 %) were domestic cats, 11 (8.3 %) were wild felines, and one (0.7 %) was an exotic felid. Twenty-one (17.5 %) were outdoor cats. Of the total, 89 (67.4 %) had contact with other animals of the same species. It was possible to isolate Sporothrix schenckii from the claws of one (0.7 %) of the felids probed; this animal exhibited generalised sporotrichosis and had infected a female veterinarian. The potential pathogenic agents Microsporum canis and Malassezia pachydermatis were isolated in 12.1 and 5.3 % of the animals, respectively. The following anemophilous fungi, which were considered to be contaminants, were also isolated: Penicillium sp. (28 or 21.2 %), Aspergillus sp. (13 or 9.8 %), Rhodotorula sp. (5 or 3.8 %), Candida sp. (5 or 3.8 %), Trichoderma sp. (1 or 0.7 %), and Acremonium sp. (1 or 0.7 %). Due to the low magnitude of occurrence (0.7 %) of Sporothrix in feline claws, the potential of the cats evaluated in this study to be sources of infection in the city of São Paulo is considerably low.
Resumo:
Terrestrial radioactivity for most individual is the major contributor to the total dose and is mostly provided by 238U, 232Th and 40K radionuclides. In particular indoor radioactivity is principally due to 222Rn, a radioactive noble gas descendent of 238U, second cause of lung cancer after cigarettes smoking. Vulsini Volcanic District is a well known quaternary volcanic area located between the northern Latium and southern Tuscany (Central Italy). It is characterized by an high natural radiation background resulting from the high concentrations of 238U, 232Th and 40K in the volcanic products. In this context, subduction-related metasomatic enrichment of incompatible elements in the mantle source coupled with magma differentiation within the upper crust has given rise to U, Th and K enriched melts. Almost every ancient village and town located in this part of Italy has been built with volcanic rocks pertaining to the Vulsini Volcanic District. The radiological risk of living in this area has been estimated considering separately: a. the risk associated with buildings made of volcanic products and built on volcanic rock substrates b. the risk associated to soil characteristics. The former has been evaluated both using direct 222Rn indoor measurements and simulations of “standard rooms” built with the tuffs and lavas from the Vulsini Volcanic District investigated in this work. The latter has been carried out by using in situ measurements of 222Rn activity in the soil gases. A radon risk map for the Bolsena village has been developed using soil radon measurements integrating geological information. Data of airborne radioactivity in ambient aerosol at two elevated stations in Emilia Romagna (North Italy) under the influence of Fukushima plume have been collected, effective doses have been calculated and an extensive comparison between doses associated with artificial and natural sources in different area have been described and discussed.
Resumo:
Photovoltaic modules based on thin film technology are gaining importance in the photovoltaic market, and module installers and plant owners have increasingly begun to request methods of performing module quality control. These modules pose additional problems for measuring power under standard test conditions (STC), beyond problems caused by the temperature of the module and the ambient variables. The main difficulty is that the modules’ power rates may vary depending both on the amount of time they have been exposed to the sun during recent hours and on their history of sunlight exposure. In order to assess the current state of the module, it is necessary to know its sunlight exposure history. Thus, an easily accomplishable testing method that ensures the repeatability of the measurements of the power generated is needed. This paper examines different tests performed on commercial thin film PV modules of CIS, a-Si and CdTe technologies in order to find the best way to obtain measurements. A method for obtaining indoor measurements of these technologies that takes into account periods of sunlight exposure is proposed. Special attention is paid to CdTe as a fast growing technology in the market.
Resumo:
Mode of access: Internet.
Resumo:
Traffic emissions and tobacco smoke are considered two main sources of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air. In this study, the impact of these sources on the level of fine particulate matter (PM2.5) and on the distribution of 15 PAHs regarded as priority pollutants by the US-EPA on PM2.5 were evaluated and compared. Outdoor and indoor PM2.5 samples were collected during winter 2008 in Oporto city in Portugal, for sampling periods of 12 and 24 hours, respectively. The outdoor PM2.5 were sampled at one site directly influenced by traffic emissions and the indoor PM2.5 samples were collected at one home directly influenced by tobacco smoke and another one without smoke. A methodology based on microwave-assisted extraction and liquid chromatography with fluorescence detection was applied for the efficient PAHs determination in indoor and outdoor PM2.5. PAHs in indoor PM2.5 concentrations were significantly influenced by the presence of traffic and tobacco smoking emissions. The mean of ΣPAHs in the outdoor traffic PM2.5 was not significantly different from the value attained in the indoor without smoking site. The tobacco smoke increased significantly PAHs concentrations on average about 1000 times more, when compared with the outdoor profile samples suggesting that tobacco smoking may be the most important source of indoor PAHs pollution.
Resumo:
Background/Objectives Ambient air pollution can alter cytokine concentrations as shown in vitro and following short-term exposure to high air pollution levels in vivo. Exposure to pollution during late pregnancy has been shown to affect fetal lymphocytic immunophenotypes. However, effects of prenatal exposure to moderate levels of air pollutants on cytokine regulation in cord blood of healthy infants are unknown. Methods In a birth cohort of 265 healthy term-born neonates, we assessed maternal exposure to particles with an aerodynamic diameter of 10 µm or less (PM10), as well as to indoor air pollution during the last trimester, specifically the last 21, 14, 7, 3 and 1 days of pregnancy. As a proxy for traffic-related air pollution, we determined the distance of mothers' homes to major roads. We measured cytokine and chemokine levels (MCP-1, IL-6, IL-10, IL-1ß, TNF-α and GM-CSF) in cord blood serum using LUMINEX technology. Their association with pollution levels was assessed using regression analysis, adjusted for possible confounders. Results Mean (95%-CI) PM10 exposure for the last 7 days of pregnancy was 18.3 (10.3–38.4 µg/m3). PM10 exposure during the last 3 days of pregnancy was significantly associated with reduced IL-10 and during the last 3 months of pregnancy with increased IL-1ß levels in cord blood after adjustment for relevant confounders. Maternal smoking was associated with reduced IL-6 levels. For the other cytokines no association was found. Conclusions Our results suggest that even naturally occurring prenatal exposure to moderate amounts of indoor and outdoor air pollution may lead to changes in cord blood cytokine levels in a population based cohort.
Resumo:
INTRODUÇÃO: O arco e flecha é um esporte estático que requer força e resistência da parte superior do corpo, sendo que a habilidade do arqueiro é definida pela capacidade de atirar a flecha no alvo em um intervalo de tempo com precisão. A contração muscular gerada durante a execução do gesto esportivo propicia o aumento da temperatura corporal, da oxidação de glicose e da sudorese, podendo esta ser potencializada pelas condições climáticas às quais o atleta é exposto. Todos estes fatores alteram a percepção de esforço e a própria geração de força, impondo um estresse negativo à performance. OBJETIVOS: Avaliar e relacionar o estado de hidratação de atletas de arco e flecha com alterações fisiológicas e de força intervenientes no rendimento competitivo. MÉTODOS: Participaram 11 arqueiros em duas competições distintas (indoor e outdoor). Foram mensurados parâmetros relacionados ao estado de hidratação, glicemia, percepção de esforço subjetivo e alteração na força de preensão palmar. RESULTADOS: Os atletas analisados apresentaram alterações significativas nos parâmetros relacionados ao estado hídrico em diferentes dias, provavelmente relacionadas às condições climáticas adversas na competição outdoor (34ºC e 60% URA) em relação à competição indoor (22ºC e 90% URA). O mesmo não foi observado para a glicemia. CONCLUSÃO: Este trabalho é o primeiro a comprovar a relação direta entre fatores climáticos e de rendimento em arqueiros de alto nível durante evento competitivo, assim como a evidenciar quais métodos não invasivos seriam os mais indicados para a avaliação do impacto destas alterações.