963 resultados para Indoor air quality (IAQ)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The indoor air quality (IAQ) in buildings is currently assessed by measurement of pollutants during building operation for comparison with air quality standards. Current practice at the design stage tries to minimise potential indoor air quality impacts of new building materials and contents by selecting low-emission materials. However low-emission materials are not always available, and even when used the aggregated pollutant concentrations from such materials are generally overlooked. This paper presents an innovative tool for estimating indoor air pollutant concentrations at the design stage, based on emissions over time from large area building materials, furniture and office equipment. The estimator considers volatile organic compounds, formaldehyde and airborne particles from indoor materials and office equipment and the contribution of outdoor urban air pollutants affected by urban location and ventilation system filtration. The estimated pollutants are for a single, fully mixed and ventilated zone in an office building with acceptable levels derived from Australian and international health-based standards. The model acquires its dimensional data for the indoor spaces from a 3D CAD model via IFC files and the emission data from a building products/contents emissions database. This paper describes the underlying approach to estimating indoor air quality and discusses the benefits of such an approach for designers and the occupants of buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapid growth in the global population requires expansion of building stock, which in turn calls for increased energy demand. This demand varies in time and also between different buildings, yet, conventional methods are only able to provide mean energy levels per zone and are unable to capture this inhomogeneity, which is important to conserve energy. An additional challenge is that some of the attempts to conserve energy, through for example lowering of ventilation rates, have been shown to exacerbate another problem, which is unacceptable indoor air quality (IAQ). The rise of sensing technology over the past decade has shown potential to address both these issues simultaneously by providing high–resolution tempo–spatial data to systematically analyse the energy demand and its consumption as well as the impacts of measures taken to control energy consumption on IAQ. However, challenges remain in the development of affordable services for data analysis, deployment of large–scale real–time sensing network and responding through Building Energy Management Systems. This article presents the fundamental drivers behind the rise of sensing technology for the management of energy and IAQ in urban built environments, highlights major challenges for their large–scale deployment and identifies the research gaps that should be closed by future investigations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of sustainable assessment methods in the UK is on the rise, anticipating the future regulatory trajectory towards zero carbon by 2016. The indisputable influence of sustainable rating tools on UK building regulations conveys the importance of evaluating their effectiveness in achieving true sustainable design, without adversely effecting human health and wellbeing. This paper reviews indoor air-quality (IAQ) issues addressed by UK sustainable assessment tools, and the potential trade-offs between building energy conservation and IAQ. The barriers to effective adoption of IAQ strategies are investigated, including recommendations, suggestions, and future research needs. The review identified a fundamental lack of IAQ criteria in sustainable assessment tools aimed at the residential sector. The consideration of occupants’ health and well-being should be paramount in any assessment scheme, and should not be overshadowed or obscured by the drive towards energy efficiency. A balance is essential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tem havido uma preocupação crescente com a qualidade do ar interior (QAI) nas escolas em muitos países. Muitos estudos epidemiológicos têm encontrado diferenças regionais entre ambientes interiores. Apesar da elevada incidência de asma e rinite na população infantil, praticamente nada se sabia sobre a QAI em escolas portuguesas. A percepção dos problemas de QAI é crucial para avaliar os riscos para a saúde e rendimento dos estudantes, e para sugerir meios de reduzir a exposição a poluentes indesejáveis. Neste estudo procurou-se obter as concentrações de poluentes de interesse em estabelecimentos de ensino do 1º ciclo de Lisboa e Aveiro, estimar o estado atual de casos de asma e rinite em escolas primárias da capital, avaliar a influência de diferentes materiais das salas de aula/construção e hábitos escolares na QAI, identificar potenciais fontes de poluentes nos interiores e exteriores das salas de aula e propor medidas mitigadoras. Catorze escolas de Lisboa foram visitadas para obter a caracterização física das construções em termos de estrutura, ventilação, materiais de acabamento, produtos de limpeza, densidade de ocupação e potenciais fontes interiores de poluição. Os estudantes foram questionados sobre os seus hábitos e sintomas respiratórios através de inquéritos do modelo ISAAC (International Study of Asthma and Allergies in Childhood). Durante a primavera, outono e inverno (2008-2010), nas salas de aula e pátios, foram monitorizados, por amostragem passiva, compostos orgânicos voláteis (COVs), carbonilos e dióxido de azoto (NO2). Foram também medidos parâmetros de conforto e níveis de microrganismos. Duas escolas localizadas, uma no centro da cidade e outra na região suburbana, em Aveiro foram estudadas em 2010. Parâmetros de conforto, microrganismos, COVs, NO2, material particulado (PM10) foram medidos no interior e no exterior de ambas escolas. Os iões solúveis, carbono orgânico e elementar (OC e EC), e compostos orgânicos presentes no material particulado foram subsequentemente analisados em laboratório. Uma medida mitigadora - fitoremediação - foi avaliada na escola do centro da cidade de Aveiro em 2011. Os resultados do estudo mostraram que a QAI é pior do que a do ar exterior. Em geral, os níveis de CO2 e dos bioaerosóis excederam os níveis máximos aceitáveis para o conforto dos ocupantes estipulado pelas regulamentações portuguesas. Quase todos os COVs e carbonilos identificados mostraram razões interior/exterior (I/E) maiores que uma unidade, o que demonstra a importante contribuição de fontes interiores em todas as escolas. As razões I/E das concentrações de NO2 nunca excederam a unidade. Os níveis interiores diários de PM10 foram sempre maiores que os exteriores, exceto nos fins de semana. Após a colocação de plantas numa das salas de aula, observou-se uma redução estatisticamente significativa nos níveis de CO2, COVs, carbonilos, PM10, OC, e dos iões nitrato, sulfato, amónia, cálcio e carbonato. A possível redução dos níveis de poluentes no interior após a colocação de plantas pode representar uma solução de baixo custo para reduzir a exposição a muitos compostos, melhorar o rendimento e aumentar o bem estar dos alunos e professores em sala de aula.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor Air Quality (IAQ) can have significant implications for health, productivity, job performance, and operating cost. Professional experience in the field of indoor air quality suggests that high expectations (better than nationally established standards) (American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE)) of workplace indoor air quality lead to increase air quality complaints. To determine whether there is a positive association between expectations and indoor air quality complaints, a one-time descriptive and analytical cross-sectional pilot study was conducted. Area Safety Liaisons (n = 330) at University of Texas Health Science Center – Houston were asked to answer a questionnaire regarding their expectations of four workplace indoor air quality indicators i.e., (temperature, relative humidity, carbon dioxide, and carbon monoxide) and if they experienced and reported indoor air quality problems. A chi-square test for independence was used to evaluate associations among the variables of interest. The response rate was 54% (n = 177). Results did not show significant associations between expectation and indoor air quality. However, a greater proportion of Area Safety Liaisons who expected indoor air quality indicators to be better than the established standard experienced greater indoor air quality problems. Similarly, a slightly higher proportion of Area Liaisons who expected indoor air quality indicators to be better than the standard reported greater indoor air quality complaints. ^ The findings indicated that a greater proportion of Area Safety Liaisons with high expectations (conditions that are beyond what is considered normal and acceptable by ASHRAE) experienced greater indoor air quality discomfort. This result suggests a positive association between high expectations and experienced and reported indoor air quality complaints. Future studies may be able to address whether the frequency of complaints and resulting investigations can be reduced through information and education about what are acceptable conditions.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poor hospital indoor air quality (IAQ) may lead to hospital-acquired infections, sick hospital syndrome and various occupational hazards. Air-control measures are crucial for reducing dissemination of airborne biological particles in hospitals. The objective of this study was to perform a survey of bioaerosol quality in different sites in a Portuguese Hospital, namely the operating theater (OT), the emergency service (ES) and the surgical ward (SW). Aerobic mesophilic bacterial counts (BCs) and fungal load (FL) were assessed by impaction directly onto tryptic soy agar and malt extract agar supplemented with antibiotic chloramphenicol (0.05%) plates, respectively using a MAS-100 air sampler. The ES revealed the highest airborne microbial concentrations (BC range 240-736 CFU/m(3) CFU/m(3); FL range 27-933 CFU/m(3)), exceeding, at several sampling sites, conformity criteria defined in national legislation [6]. Bacterial concentrations in the SW (BC range 99-495 CFU/m(3)) and the OT (BC range 12-170 CFU/m(3)) were under recommended criteria. While fungal levels were below 1 CFU/m(3) in the OT, in the SW (range 1-32 CFU/m(3)), there existed a site with fungal indoor concentrations higher than those detected outdoors. Airborne Gram-positive cocci were the most frequent phenotype (88%) detected from the measured bacterial population in all indoor environments. Staphylococcus (51%) and Micrococcus (37%) were dominant among the bacterial genera identified in the present study. Concerning indoor fungal characterization, the prevalent genera were Penicillium (41%) and Aspergillus (24%). Regular monitoring is essential for assessing air control efficiency and for detecting irregular introduction of airborne particles via clothing of visitors and medical staff or carriage by personal and medical materials. Furthermore, microbiological survey data should be used to clearly define specific air quality guidelines for controlled environments in hospital settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5 , PM10 , bacteria and fungi, carbon dioxide (CO2 ), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000 ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5 μg/m(3) ) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cross-sectional survey was conducted to characterize the indoor air quality (IAQ) in schools and its relationship with children's respiratory symptoms. Concentrations of volatile organic compounds (VOC), aldehydes, PM2.5, PM10, carbon dioxide, bacteria and fungi were assessed in 73 classrooms from 20 public primary schools located in Porto, Portugal. Children who attended the selected classrooms (n = 1134) were evaluated by a standardised health questionnaire completed by the legal guardians; spirometry and exhaled nitric oxide tests. The results indicated that no classrooms presented individual VOC pollutant concentrations higher than the WHO IAQ guidelines or by INDEX recommendations; while PM2.5, PM10 and bacteria levels exceeded the WHO air quality guidelines or national limit values. High levels of total VOC, acetaldehyde, PM2.5 and PM10 were associated with higher odds of wheezing in children. Thus, indoor air pollutants, some even at low exposure levels, were related with the development of respiratory symptoms. The results pointed out that it is crucial to take into account the unique characteristics of the public primary schools, to develop appropriate control strategies in order to reduce the exposure to indoor air pollutants and, therefore, to minimize the adverse health effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor environmental conditions in classrooms, in particular temperature and indoor air quality, influence students’ health, attitude and performance. In recent years, several studies regarding indoor environmental quality of classrooms were published and natural ventilation proved to have great potential, particularly in southern European climate. This research aimed to evaluate indoor environmental conditions in eight schools and to assess their improvement potential by simple natural ventilation strategies. Temperature, relative humidity and carbon dioxide concentration were measured in 32 classrooms. Ventilation performance of the classrooms was characterized using two techniques, first by fan pressurization measurements of the envelope airtightness and later by tracer gas measurements of the air change rate assuming different envelope conditions. A total of 110 tracer gas measurements were made and the results validated ventilation protocols that were tested afterward. The results of the ventilation protocol implementation were encouraging and, overall, a decrease on the CO2 concentration was observed without modifying the comfort conditions. Nevertheless, additional measurements must be performed for winter conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Characterization of indoor air quality in school classrooms is crucial to children’s health and performance. The present study was undertaken to characterize the indoor air quality in six naturally ventilated classrooms of three schools in Cassino (Italy). Indoor particle number, mass, black carbon, CO2 and radon concentrations, as well as outdoor particle number were measured within school hours during the winter and spring season. The study found the concentrations of indoor particle number were influenced by the concentrations in the outdoors; highest BC values were detected in classrooms during peak traffic time. The effect of different seasons’ airing mode on the indoor air quality was also detected. The ratio between indoor and outdoor particles was of 0.85 ± 0.10 in winter, under airing conditions of short opening window periods, and 1.00 ± 0.15 in spring when the windows were opened for longer periods. This was associated to a higher degree of penetration of outdoor particles due to longer period of window opening. Lower CO2 levels were found in classrooms in spring (908 ppm) than in winter (2206 ppm). Additionally, a greater reduction in radon concentrations was found in spring. In addition, high PM10 levels were found in classrooms during break time due to re-suspension of coarse particles. Keywords: classroom; Ni/Nout ratio; airing by opening windows; particle number

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a significant lack of indoor air quality research in low energy homes. This study compared the indoor air quality of eight
newly built case study homes constructed to similar levels of air-tightness and insulation; with two different ventilation strategies (four homes with Mechanical Ventilation with Heat Recovery (MVHR) systems/Code level 4 and four homes naturally ventilated/Code level 3). Indoor air quality measurements were conducted over a 24 h period in the living room and main bedroom of each home during the summer and winter seasons. Simultaneous outside measurements and an occupant diary were also employed during the measurement period. Occupant interviews were conducted to gain information on perceived indoor air quality, occupant behaviour and building related illnesses. Knowledge of the MVHR system including ventilation related behaviour was also studied. Results suggest indoor air quality problems in both the mechanically ventilated and naturally ventilated homes, with significant issues identified regarding occupant use in the social homes