775 resultados para Incremental protocol


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyze the effect of running intensity on stride length (SL), stride frequency (SF), stride time (ST) and the electromyographic signal of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), tibialis anterior (TA), biceps femoris (BF) and gastrocnemius lateralis (GL) muscles. Methods: Nine well-trained runners performed an incremental protocol with an initial velocity of 10km.h-1, and increments of 1km.h-1 every 3minutes until exhaustion. The electromyographic activity, SL, SF, ST, inter-stride coefficient of variation, and association between kinematic and electromyographic parameters were calculated at 60%, 80% and 100% of maximum running velocity. Results: SL, SF and electromyographic activity of the RF, VM, VL and GL increased and the ST decreased with increased running speed. Electromyographic variability of VL and VM was higher than GL, and variability was lower in TA than all other muscles. The inter-stride variability of muscle activation was associated with kinematic parameters, and their variability, differently as running speed increased. Conclusion: The incremental protocol increased electromyographic activity differently among lower limb muscles; increased SF and SL, and decreased ST, without changing the variability of these variables. Muscle activation variability was correlated with kinematic parameters, but the relationships among these measures varied with running intensity. © 2013 .

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Muscle fatigue is described as a cause of injuries among the many related to the running practice. Therefore, the purpose of this study was to analyze the behavior of the amplitude (RMS) and median frequency (MF) of EMG signal of the iliocostalis (CI), rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM) biceps femoris (long head) (BFCL), tibialis anterior (TA) and gastrocnemius (lateral) (LNG) from the right lower limb, and the behavior of the parameters of amplitude (AP) and frequency (PF) spent in different percentages of the maximum speed during incremental protocol of treadmill running. 10 volunteers participated in this study, athletes, male, aged between 18 and 30 years with no history of injury in lower limbs and similar anthropometry. The protocol consisted of a treadmill test with initial velocity of 10 km.h-¹ and increments of 1 km.h-¹ each three minutes until volitional exhaustion, without rest interval. Synchronized collections were made of electromyographic and kinematic data. The signals were obtained through an acquisition module of biological signals (Telemyo 900 - Noraxon - USA) and software (Myoresearch - Noraxon - USA) calibrated with a sampling frequency of 1000 Hz, gain 2000 times. The raw data were filtered with a 60Hz notch filter, high pass and low pass 20Hz to 500Hz. To capture the image was used a digital video recorder (model NV-GS320, PANASONIC brand), and for image scanning and kinematic data collection was used the software Peak Motus 9.0 (ViconPeak). To obtain the values of RMS and FM analyzed the last ten passes of each speed through a specific routine (Matlab). To obtain these variables AP (m) and FP (stride I min) were analyzed for the last ten past each speed, using specific software (Peak Motus 9.0). After verification of data normality (Shapiro-Wilk) and homogeneity of the data (Levene), the comparison ...(Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Supplementation with propionyl-L-carnitine (PLC) may be of use in improving the exercise capacity of people with peripheral arterial disease. Methods: After a 2-wk exercise familiarization phase, seven subjects displaying intermittent claudication were studied over a 12-wk period consisting of three 4-wk phases, baseline (B), supplementation (S), and placebo (P). PLC was supplemented at 2 g(.)d(-1), and subjects were blinded to the order of supplementation. Unilateral calf strength and endurance were assessed weekly. Walking performance was assessed at the end of each phase using an incremental protocol, during which respiratory gases were collected. Results: Although there was not a significant increase in maximal walking time (similar to 14%) in the whole group, walking time improved to a greater extent than the individual baseline coefficient of variation in four of the seven subjects. The changes in walking performance were correlated with changes in the respiratory exchange ratio both at steady state (r = 0.59) and maximal exercise (r = 0.79). Muscle strength increased significantly from 695 +/- 198 N to 812 +/- 249 N by the end of S. Changes in calf strength from B to S were modestly related to changes in walking performance (r = 0.56). No improvements in calf endurance were detected throughout the study. Conclusions: These preliminary data suggest that, in addition to walking performance, muscle strength can be increased in PAD patients after 4 wk of supplementation with propionyl-L-carnitine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Buchheit, M, Al Haddad, H, Millet GP, Lepretre, PM, Newton, M, and Ahmaidi, S. Cardiorespiratory and cardiac autonomic responses to 30-15 Intermittent Fitness Test in team sport players. J Strength Cond Res 23(1): xxx-xxx, 2009-The 30-15 Intermittent Fitness Test (30-15IFT) is an attractive alternative to classic continuous incremental field tests for defining a reference velocity for interval training prescription in team sport athletes. The aim of the present study was to compare cardiorespiratory and autonomic responses to 30-15IFT with those observed during a standard continuous test (CT). In 20 team sport players (20.9 +/- 2.2 years), cardiopulmonary parameters were measured during exercise and for 10 minutes after both tests. Final running velocity, peak lactate ([La]peak), and rating of perceived exertion (RPE) were also measured. Parasympathetic function was assessed during the postexercise recovery phase via heart rate (HR) recovery time constant (HRRtau) and HR variability (HRV) vagal-related indices. At exhaustion, no difference was observed in peak oxygen uptake (&OV0312;o2peak), respiratory exchange ratio, HR, or RPE between 30-15IFT and CT. In contrast, 30-15IFT led to significantly higher minute ventilation, [La]peak, and final velocity than CT (p < 0.05 for all parameters). All maximal cardiorespiratory variables observed during both tests were moderately to well correlated (e.g., r = 0.76, p = 0.001 for &OV0312;o2peak). Regarding ventilatory thresholds (VThs), all cardiorespiratory measurements were similar and well correlated between the 2 tests. Parasympathetic function was lower after 30-15IFT than after CT, as indicated by significantly longer HHRtau (81.9 +/- 18.2 vs. 60.5 +/- 19.5 for 30-15IFT and CT, respectively, p < 0.001) and lower HRV vagal-related indices (i.e., the root mean square of successive R-R intervals differences [rMSSD]: 4.1 +/- 2.4 and 7.0 +/- 4.9 milliseconds, p < 0.05). In conclusion, the 30-15IFT is accurate for assessing VThs and &OV0312;o2peak, but it alters postexercise parasympathetic function more than a continuous incremental protocol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to analyze the electromyographic signal of the rectus femuris (RF), vastus lateralis (VL), biceps femuris (BF), tibialis anterior (TA), and gastrocnemius lateralis (GL) muscles of seven male volunteers, during different running velocities; and determine and compare the EMG(FT) (electromyographic fatigue threshold), LT (lactate threshold) and AT (anaerobic threshold). The running protocol started with a velocity of 10 km.h(-1) and each three minutes elapsed occurred an increments of 1 km.h(-1) until the exhaustion, with an 30 second interval between each velocity increment to collect 25 mu l of blood. The increase of RMS values was verified in the RF in the velocities of 12 km.h(-1) to 14 km.h(-1). The EMG(FT) showed similarity between the muscles and in the indexes were found the following significant differences: AT > LT; EMG(FT) RF and EMG(FT) VL < AT and EMG(FT) VL and EMG(FT) BF > LT. These data confirmed the viability of using the EMGFT as a possible indicator to analyze the muscle fatigue.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The actual study goal is to test the Ellestad and Weltman protocol concordance in the prediction of VO2max in Futsal athletes. There was no significant difference between the two protocols, there was significant correlation between methods, but the Bland & Altman plotting shown very high amplitude in the Confident Interval at 95%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We observed 82 healthy subjects, from both sexes, aged between 19 and 77 years. All subjects performed two different tests: for being scientifically acknowledged, the first one was used as a reference and it was a stress test (CPX). During the entire test, heart rate and gas exchange were recorded continuously; the second, the actual object of this study, was a submaximal test (TOP). Only heart rate was recorded continuously. The main purpose was to determinate an index of physical fitness as result of TOP. CPX test allowed us to individuate anaerobic threshold. We used an incremental protocol of 10/20 Watt/min, different by age. For our TOP test we used an RHC400 UPRIGHT BIKE, by Air Machine. Each subject was monitored for heart frequency. After 2 minutes of resting period there was a first step: 3 minutes of pedalling at a constant rate of 60 RPM, (40 watts for elder subjects and 60 watts for the younger ones). Then, the subject was allowed to rest for a recovery phase of 5 minutes. Third and last step consisted of 3 minutes of pedalling again at 60 RPM but now set to 60 watts for elder subjects and 80 watts for the young subjects. Finally another five minutes of recovery. A good correlation was found between TOP and CPX results especially between punctua l heart rate reserve (HRR’) and anaerobic threshold parameters such as Watt, VO2, VCO2 . HRR’ was obtained by subtracting maximal heart rate during TOP from maximal theoretic heart rate (206,9-(0,67*age)). Data were analyzed through cluster analysis in order to obtain 3 homogeneous groups. The first group contains the least fit subjects (inactive, women, elderly). The other groups contain the “average fit” and the fittest subjects (active, men, younger). Concordance between test resulted in 83,23%. Afterwards, a linear combinations of the most relevant variables gave us a formula to classify people in the correct group. The most relevant result is that this submaximal test is able to discriminate subjects with different physical condition and to provide information (index) about physical fitness through HRR’. Compared to a traditional incremental stress test, the very low load of TOP, short duration and extended resting period, make this new method suitable to very different people. To better define the TOP index, it is necessary to enlarge our subject sample especially by diversifying the age range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. The aim of the present study was to investigate the validity of the Lactate Minimum Test (LMT) for the determination of peak VO2 on a cycle ergometer and to determine the submaximal oxygen uptake (VO2) and pulmonary ventilation (VE) responses in an incremental exercise test when it is preceded by high intensity exercise (i.e., during a LMT).Methods. Ten trained male athletes (triathletes and cyclists) performed 2 exercise tests in random order on an electromagnetic cycle ergometer: 1) Control Test (CT): an incremental test with an initial work rate of 100 W, and with 25 W increments at 3-min intervals, until voluntary exhaustion; 2) LMT: an incremental test identical to the CT, except that it was preceded by 2 supramaximal bouts of 30-sec (similar to120% VO(2)peak) with a 30-sec rest to induce lactic acidosis. This test started 8 min after the induction of acidosis.Results. There was no significant difference in peak VO2 (65.6+/-7.4 ml.kg(-1).min(-1); 63.8+/-7.5 ml.kg(-1).min(-1) to CT and LMT, respectively). However, the maximal power output (POmax) reached was significantly higher in CT (300.6+/-15.7 W) than in the LMT (283.2+/-16.0 W).VO2 and VE were significantly increased at initial power outputs in LMT.Conclusion. Although the LMT alters the submaximal physiological responses during the incremental phase (greater initial metabolic cost), this protocol is valid to evaluate peak VO2, although the POmax reached is also reduced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)