458 resultados para Incineration cemetery


Relevância:

60.00% 60.00%

Publicador:

Resumo:

El presente estudio tiene por objeto estudiar y analizar la vajilla y el instrumental metálico relacionados con los rituales de sacrificio y banquete funerario que se practicaron en el valle medio del Ebro durante los siglos centrales del Ier Milenio a. C. La investigación se ha centrado en la extensa información que proporciona la necrópolis de El Castillo (Castejón, Navarra), un espacio funerario que, por el momento, constituye una asombrosa excepción en un horizonte marcado por la ausencia o la parquedad de los datos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research of advanced technologies for energy generation contemplates a series of alternatives that are introduced both in the investigation of new energy sources and in the improvement and/or development of new components and systems. Even though significant reductions are observed in the amount of emissions, the proposed alternatives require the use of exhaust gases cleaning systems. The results of environmental analyses based on two configurations proposed for urban waste incineration are presented in this paper; the annexation of integer (Boolean) variables to the environomic model makes it possible to define the best gas cleaning routes based on exergetic cost minimisation criteria. In this first part, the results for steam cogeneration system analysis associated with the incineration of municipal solid wastes (MSW) is presented. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the first paper of this paper (Part I), conditions were presented for the gas cleaning technological route for environomic optimisation of a cogeneration system based in a thermal cycle with municipal solid waste incineration. In this second part, an environomic analysis is presented of a cogeneration system comprising a combined cycle composed of a gas cycle burning natural gas with a heat recovery steam generator with no supplementary burning and a steam cycle burning municipal solid wastes (MSW) to which will be added a pure back pressure steam turbine (another one) of pure condensation. This analysis aims to select, concerning some scenarios, the best atmospheric pollutant emission control routes (rc) according to the investment cost minimisation, operation and social damage criteria. In this study, a comparison is also performed with the results obtained in the Case Study presented in Part I. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy of a larvicide, temephos, for controlling Ae. aegypti was evaluated in a cemetery in Buenos Aires, Argentina. Breeding sites decreased from 18.4% in the first study period (Nov 1998 to May 1999, without temephos) to 2.2% in the second period (Nov 1999 to May 2000, two applications), and to 0.05% in the third one (Nov 2000 to May 2001, five applications). Ovitraps with eggs decreased from 17% in the first period to 5.8% in the second period, and to 2.9% in the third one. Results suggest that, in Buenos Aires, Ae. aegypti populations are highly susceptible to temephos. It is recommended to limit the use of temephos to prevent potential epidemics rather than for routine control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This introductory brief has been written as a response to a request for information on HIA and waste management, with particular reference to incineration. EU legislation forms the basis for much of Irish waste management policy. Waste Management – Taking Stock and Moving Forward (2004) sets targets for increased prevention and minimisation, encourages reuse and gives preference to recovery and recycling, which is in line with the EU’s Sixth Environmental Action Plan (2002). In the area of waste incineration, the Waste Incineration Directive (2000/76/EC) has been transposed into Irish law and sets operating requirements for the incineration of waste.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cemeteries are ideal urban areas to study the importance of different types of containers as breeding sites of Aedes aegypti (L.). In the present study, the suitability of plastic, glass, ceramic and metal containers was evaluated in four patches within a cemetery of Buenos Aires City, Argentina. Between October 1998 and May 2000, we found 215 breeding sites of Ae. aegypti out of 13,022 water-filled containers examined. In two patches containing microenvironments sheltered from the sun, the use of the different types of containers was proportional to the offer (correlation coefficient = 0.99, P < 0.05 in both cases). In the remaining patches, plastic and metal containers were the most and less frequent breeding sites, respectively (P < 0.001 in both cases). The number of immatures per breeding site (median = 4.5) did not show significant differences among the four types of containers examined (H3, 215 = 1.216, P = 0.749). Differences found in patches from a same cemetery suggest that different microenvironmental conditions affect the suitability of each type of container for Ae. aegypti breeding. Plastic containers appeared as key breeding sites that should be removed to reduce the Ae. aegypti population in the study area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the excavations of the XIX century Meadowlark cemetery (Manhattan, Kansas, US), samples of sediments were taken from around five skeletons, and analyzed to detect intestinal parasites. No helminth eggs were found, but immunological ELISA tests for Entamoeba histolytica were positive in three samples. The immunological techniques have been successfully used in paleoparasitology to detect protozoan infections. Amoebiasis could have been a severe disease in the past, especially where poor sanitary conditions prevailed, and there is evidence that this cemetery may have been used in a situation where poor sanitary conditions may have prevailed. The presence of this protozoan in US during the late XIX century gives information on the health of the population and provides additional data on the parasite's evolution since its appearance in the New World.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of the administration of spaces assigned by municipalities for the burial of the dead, this article provides a critical analysis of the techniques for the governance of political collectives of citizens implemented by public authorities. More broadly, this article shows how funerary practices (i.e. the social practices surrounding death-the rituals, the legislation, etc.) can be used to develop a critical reading of the social relations that structure the social production of space. To this end, the authors use the conceptual tools provided by critical legal geography to explore the controversy surrounding the development of a 'carré confessionnel' (denominational area) within the Bois-de-Vaux Cemetery in Lausanne, Switzerland. Here, a focus on the techniques that allow 'nomosphere' technicians to convene a subset of the citizens within the public space reveals the administration of cemeteries as a means of governance, a method for mobilising bodies and a paradoxical means of managing flux.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigative report produced by Iowa Citizens' Aide/Ombudsman

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iowa’s spring flooding is expected to be severe, especially along the western part of the state involving the Missouri River. River levels are expected to reach flood stage and preparations are already underway to prevent or minimize damage as a result of the impending flooding. This advisory will primarily affect Woodbury, Monona, Harrison, Pottawattamie, Mills and Fremont Counties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dioxins and furans, PCDD/Fs, are highly toxic substances formed in post combustion zones in furnaces. PCDD/F emissions are regulated by a waste incineration directive which relates also to co-incineration plants. Several observations of dioxin and furan enhancements in wet scrub- bers have been reported previously. This is thought to be due to the so-called "memory effect" which occurs when dioxins and furans absorb into plastic material in scrubbers and desorb when ambient circumstances alter significantly. At the co-incineration plant involved, dioxins and furans are controlled with a wet scrubber, the tower packing of which is made of plastic in which activated carbon particles are dispersed. This should avoid the memory effect and act as a dioxin and furan sink since dioxins and furans are absorbed irreversibly into the packing ma- terial. In this case, the tower packing in the scrubber is covered with a white layer that has been found to be mainly aluminium. The aim of this thesis was to determine the aluminium balance and the dioxin and furan behaviour in the scrubber and, thus, the impacts that the foul- ing has on dioxin and furan removal. The source of aluminium, reasons for fouling and further actions to minimize its impacts on dioxin and furan removal were also to be discovered. Measurements in various media around the scrubber and in fuels were made and a profile analysis of PCDD/F and mass balance calculations were carried out. PCDD/F content de- creased in the scrubber. The reduced PCDD/F was not discharged into scrubbing water. The removal mechanism seems to work in spite of the fouling, at least with low PCDD/F loads. Most of the PCDD/F in excess water originates from the Kymijoki River which is used as feeding water in the scrubber. Fouling turned out to consist mainly of aluminium hydroxides. Sludge combusted in the furnace was found to be a significant source of aluminium. Ways to minimize the fouling would be adjustment of pH to a proper lever, installation of a mechanical filter to catch the loose material from the scrubbing water and affecting the aluminium content of the sludge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion reduces the lifetime of municipal solid waste incineration (MSWI) superheater tubes more than any other cause. It can be minimized by the careful selection of those materials that are most resistant to corrosion under operating conditions. Since thousands of different materials are already known and many more are developed every year, here the selection methodology developed by Prof. Ashby of the University of Cambridge was used to evaluate the performance of different materials to be used as MSWI superheater tubes. The proposed materials can operate at steam pressures and temperatures over 40 bars and 400ºC, respectively. Two case studies are presented: one makes a balanced selection between mechanical properties and cost per thermal unit; and the other focuses on increasing tube lifetime. The balanced selection showed that AISI 410 martensitic stainless steel (wrought, hard tempered) is the best candidate with a good combination of corrosion resistance, a relatively low price (0.83-0.92 e/kg) and a good thermal conductivity (23-27 W/m K). Meanwhile, Nitronic 50/XM-19 stainless steel is the most promising candidate for longterm selection, as it presents high corrosion resistance with a relatively low price (4.86-5.14 e/kg) compared to Ni-alloys.