981 resultados para In-tube SPME


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN alpha(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN alpha(2a) analyses in plasma sample were carried out within 25 min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0 MIU mL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN alpha(2a) in plasma samples for therapeutic drug monitoring. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for determination of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in human plasma has been developed, validated, and further applied to pharmacokinetic study in pregnant women with gestational diabetes mellitus (GDM) subjected to epidural anesthesia. Important factors in the optimization of in-tube SPME performance are discussed, including the draw/eject sample volume, draw/eject cycle number, draw/eject flow rate, sample pH, and influence of plasma proteins. The limits of quantification of the in-tube SPME/LC method were 50 ng/mL for both metabolite and lidocaine. The interday and intraday precision had coefficients of variation lower than 8%, and accuracy ranged from 95 to 117%. The response of the in-tube SPME/LC method for analytes was linear over a dynamic range from 50 to 5000 ng/mL, with correlation coefficients higher than 0.9976. The developed in-tube SPME/LC method was successfully used to analyze lidocaine and its metabolite in plasma samples from pregnant women with GDM subjected to epidural anesthesia for pharmacokinetic study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os profissionais da área da saúde formam um dos grupos mais vulneráveis à infecção pelo Mycobacterium tuberculosis (Mtb). Segundo estimativas da Organização Mundial de Saúde (OMS), 8,8 milhões de pessoas estavam infectadas pelo Mtb e ocorreram 1,4 milhão de óbitos por tuberculose (TB) em 2010. A identificação de pessoas com Infecção Latente Tuberculosa (ILTB) é considerada pela OMS como uma prioridade no controle da doença, especialmente em países em desenvolvimento em que a incidência da doença ativa tem apresentado redução. O objetivo do presente trabalho foi avaliar, no Brasil, o custo-efetividade dos testes Prova Tuberculínica (PT) e Quantiferon TB Gold-In-Tube (QTF-GIT) no diagnóstico e tratamento da ILTB em profissionais de saúde atuantes na atenção básica, sob a perspectiva do Sistema Único de Saúde (SUS), comparando cinco estratégias que incluem o QTF-GIT, distintos pontos de corte para a PT e uso sequencial dos dois testes; e analisar o impacto do tabagismo sobre o risco de ILTB entre os profissionais de saúde, destacando-se a categoria da Enfermagem. Foi realizada uma avaliação econômica completa do tipo custo-efetividade, conduzida considerando uma coorte hipotética de 10.000 profissionais de saúde atuantes na atenção básica, com horizonte temporal restrito a um ano. Um modelo analítico de decisão, caracterizado por uma árvore de probabilidades de eventos, foi desenvolvido utilizando o software TreeAge ProTM 2013 para simular os resultados clínicos e impactos econômicos em saúde da nova tecnologia diagnóstica (QTF-GIT) versus a PT tradicional. Esse modelo simulou cinco estratégias diagnósticas para detecção e tratamento da ILTB: (a) PT, usando ponto de corte de 5mm; (b) PT, usando ponto de corte de 10 mm; (c) teste QTF-GIT; (d) PT, com ponto de corte de 5mm, seguida de teste QTF-GIT quando PT positiva; (e) PT, com ponto de corte de 10mm, seguida de teste QTF-GIT quando PT positiva. Foi realizada análise de sensibilidade determinística univariada. Na determinação dos fatores associados à ILTB, foi elaborado um modelo de regressão logística múltipla com seleção hierarquizada, utilizando o software Stata. A estratégia mais custo-efetiva foi a PT no ponto de corte ≥10mm, considerando como medida de desfecho tanto o número de indivíduos corretamente classificados pelos testes assim como o número de casos de TB evitados. A utilização isolada do QTF-GIT revelou-se a estratégia de menor eficiência, com RCEI= R$ 343,24 por profissional corretamente classificado pelo teste. Encontrou-se risco à ILTB significantemente maior para sexo masculino [OR=1,89; IC 95%:1,11-3,20], idade ≥ 41 anos [OR=1,56; IC 95%: 1.09-2,22], contato próximo com familiar com TB [OR=1,55; IC 95%: 1.02-2,36], status do tabagismo fumante [OR=1,75; IC 95%: 1.03-2,98] e categoria profissional da Enfermagem [OR=1,44; IC 95%: 1.02-2,03]. Concluiu-se que a PT no ponto de corte de 10mm é a estratégia diagnóstica mais custo-efetiva para ILTB entre os profissionais de saúde na atenção básica e que a ILTB está associada ao hábito do tabagismo e à categoria profissional de Enfermagem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Knowing one's HIV status is particularly important in the setting of recent tuberculosis (TB) exposure. Blood tests for assessment of tuberculosis infection, such as the QuantiFERON Gold in-tube test (QFT; Cellestis Limited, Carnegie, Victoria, Australia), offer the possibility of simultaneous screening for TB and HIV with a single blood draw. We performed a cross-sectional analysis of all contacts to a highly infectious TB case in a large meatpacking factory. Twenty-two percent were foreign-born and 73% were black. Contacts were tested with both tuberculin skin testing (TST) and QFT. HIV testing was offered on an opt-out basis. Persons with TST >or=10 mm, positive QFT, and/or positive HIV test were offered latent TB treatment. Three hundred twenty-six contacts were screened: TST results were available for 266 people and an additional 24 reported a prior positive TST for a total of 290 persons with any TST result (89.0%). Adequate QFT specimens were obtained for 312 (95.7%) of persons. Thirty-two persons had QFT results but did not return for TST reading. Twenty-two percent met the criteria for latent TB infection. Eighty-eight percent accepted HIV testing. Two (0.7%) were HIV seropositive; both individuals were already aware of their HIV status, but one had stopped care a year previously. None of the HIV-seropositive persons had latent TB, but all were offered latent TB treatment per standard guidelines. This demonstrates that opt-out HIV testing combined with QFT in a large TB contact investigation was feasible and useful. HIV testing was also widely accepted. Pairing QFT with opt-out HIV testing should be strongly considered when possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The screening and treatment of latent tuberculosis (TB) infection reduces the risk of progression to active disease and is currently recommended for HIV-infected patients. The aim of this study is to evaluate, in a low TB incidence setting, the potential contribution of an interferon-gamma release assay in response to the mycobacterial latency antigen Heparin-Binding Haemagglutinin (HBHA-IGRA), to the detection of Mycobacterium tuberculosis infection in HIV-infected patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is important that long superconducting tape must have desired strain tolerance (less reduction of Jc with applied strains) and stress tolerance (less reduction of JC in applied stresses) for its use as coils and magnets. Ag addition to the BPSCCO system has many advantages with its physical and chemical inertness to the system, reduces the processing temperature, and promotes the grain growth, grain alignment and connectivity. All these not only enhance the critical current density of the tapes but also improve the mechanical properties. But the published results show very much scattering on the type of Ag additive to be selected, method of addition and its optimum percentage. Also there are some negative reports in this regard. The present work has been undertaken to study the effect of silver addition in different forms (Ag powder, Ag2O, AgNO3) on the superconducting and mechanical properties of (Bi,Pb)-2223/Ag tapes and to find out a suitable form of Ag additive and its optimum percentage to have better superconducting and mechanical properties. Also it is the aim of the present work is to optimise the process parameters needed to prepare (Bi,Pb)-2223/Ag multifilamentary tapes of length ~ 12 m in solenoid and pancake coil forms with good critical current density and homogeneity of J C along the length of the tapes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a simple and accessible Teflon AF-2400 based tube-intube reactor, a series of pyrroles were synthesised in flow using the Paal–Knorr reaction of 1,4-diketones with gaseous ammonia. An inline flow titration technique allowed measurement of the ammonia concentration and its relationship to residence time and temperature.