123 resultados para Implantology
Resumo:
Introduction: Third molar extraction is the most frequent procedure in oral surgery. The present study evaluates the indication of third molar extraction as established by the primary care dentist (PCD) and the oral surgeon, and compares the justification for extraction with the principal reason for patient consultation. Patients and method: A descriptive study was made of 319 patients subjected to surgical removal of a third molar in the context of the Master of Oral Surgery and Implantology (Barcelona University Dental School, Barcelona, Spain) between July 2004 and March 2005. The following parameters were evaluated: sex, age, molar, type of impaction, position according to the classifications of Pell and Gregory and of Winter, and the reasons justifying extraction. Results: The lower third molars were the most commonly extracted molars (73.7%). A total of 69.6% of the teeth were covered by soft tissues only. Fifty-six percent of the lower molars corresponded to Pell and Gregory Class IIB, while 42.1% were in the vertical position. The most common reason for patient reference to our Service of Oral Surgery on the part of the PCD was prophylactic removal (51.0% versus 46.1% in the case of the oral surgeon). Discussion and conclusions. Our results show prophylaxis to be the principal indication of third molar extraction, followed by orthodontic reasons. Regarding third molars with associated clinical symptoms or signs, infectious disease-including pericoronitis- was the pathology most often observed by the oral surgeon, followed by caries. This order of frequency was seen to invert in the case of third molars referred for extraction by the PCD. A vertical position predominated among the third molars with associated pathology
Resumo:
Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. All cases were planned and operated upon with the guided surgery technique. Results: A total of 122 implants were placed in 14 males and 5 females. The intraoperative surgical complications comprised a lack of primary stability, while the postoperative complications consisted of infections and a lack of implant osteointegration. Ten implants failed. The prosthetic complications in turn comprised loosening of the provisional prosthesis screws, prosthesis tooth fracture, and a lack of passive fit of the immediate prosthesis. The degree of patient satisfaction was evaluated using a verbal scale. Conclusions: Implant restoration with the guided surgery technique and immediate functional loading is a predictable procedure, provided patient selection and the surgical technique are adequate, affording lesser postoperative morbidity and increased patient satisfaction thanks to the immediate restoration of esthetics and function
Resumo:
The application of engineering knowledge in dentistry has helped the understanding of biomechanics aspects related to osseointegrated implants. Several techniques have been used to evaluate the biomechanical load oil implants comprising the use of photoelastic stress analysis, finite element stress analysis, and strain-gauge analysis. Therefore, the purpose of this Study was to describe engineering methods used in dentistry to evaluate the biomechanical behavior of osseointegrated implants. Photoelasticity provides good qualitative information oil the overall location and concentration of stresses but produces limited quantitative information. The method serves as ail important tool for determining the critical stress points in a material and is often used for determining stress concentration factors in irregular geometries. The application of strain-gauge method oil dental implants is based oil the use of electrical resistance strain gauges and its associated equipment and provides both in vitro and vivo measurements strains under static and dynamic loads. However, strain-gauge method provides only the data regarding strain at the gauge. Finite element analysis can Simulate stress using a computer-created model to calculate stress, strain, and displacement. Such analysis has the advantage of allowing several conditions to be changed easily and allows measurement of stress distribution around implants at optional points that are difficult to examine clinically All the 3 methodologies call be useful to evaluate biomechanical implant behavior close to the clinical condition but the researcher should have enough knowledge in model fabrication (experimental delineation) and results analysis.
Resumo:
Purpose: To identify the trend of authorship in dental implant by exploring the prevalence of coauthored articles and to investigate the collaboration efforts, trends in funding involved in original articles, and their relationships. Materials: Articles published in the Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each included articles, number of authors, collaboration efforts, and extramural funding were recorded. Descriptive and analytical statistics (alpha = 0.05), including logistic regression analysis and chi(2) test, were used. Results: From a total of 2085 articles, 1503 met the inclusion criteria. Publications with 5 or more authors increased over time (P = 0.813). The amount of collaboration among different disciplines, institutions, and countries all increased. The greatest increase of collaboration was seen among institutions (P = 0.09). Non-funding studies decreased over time (P = 0.031). There was a strong association between collaboration and funding for the manuscripts during the years studied (OR, 1.5). Conclusion: The number of authors per articles and collaborative studies increased over time in implant-related journals. Collaborative studies were more likely to be funded. (Implant Dent 2011;20:68-75)
Resumo:
The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.
Resumo:
In modern implant dentistry there are several clinical indications for laser surgery. Different laser systems have a considerable spectrum of application in soft and hard peri-implant tissues. The literature was searched for clinical application of different laser wavelengths in peri-implant tissues: second-stage surgery of submerged implants, treatment of infrabony defects, removal of peri-implant hyperplastic overgrowths, and, possibly, the preparation of bone cavities for implant placement. This report describes the state-of-the-art application of different laser systems in modern implant dentistry for the treatment of peri-implant lesions and decontamination of implant surfaces. Our study evaluated in vitro examinations, clinical experience and long-term clinical studies. The exact selection of the appropriate laser system and wavelength was dependent on the scientific evaluation of recent literature and the level of changes in implant and tissue temperatures during laser application. The significant reduction in bacteria on the implant surface and the peri-implant tissues during irradiation and the cutting effects associated with the coagulation properties of the lasers are the main reasons for laser application in the treatment of peri-implant lesions and the successful long-term prognosis of failing oral implants. The various applications of lasers in implant dentistry are dependent on the wavelength and laser-tissue interactions.
Resumo:
OBJECTIVES Abstracts of systematic reviews are of critical importance, as consumers of research often do not access the full text. This study aimed to assess the reporting quality of systematic review (SR) abstracts in leading oral implantology journals. METHODS Six specialty journals were screened for SRs between 2008 and 2012. A 16-item checklist, based on the PRISMA statement, was used to examine the completeness of abstract reporting. RESULTS Ninety-three SR abstracts were included in this study. The majority were published in Clinical Oral Implants Research (43%). The mean overall reporting quality score was 72.5% (95% CI: 70.8-74.2). Most abstracts were structured (97.9%), adequately reporting objectives (97.9%) and conclusions (93.6%). Conversely, inadequate reporting of methods of the study, background (79.6%), appraisal (65.6%), and data synthesis (65.6%) were observed. Registration of reviews was not reported in any of the included abstracts. Multivariate analysis revealed no difference in reporting quality with respect to continent, number of authors, or meta-analysis conduct. CONCLUSIONS The results of this study suggest that the reporting quality of systematic review abstracts in implantology journals requires further improvement. CLINICAL SIGNIFICANCE Better reporting of SR abstracts is particularly important in ensuring the reliability of research findings, ultimately promoting the practice of evidence-based dentistry. Optimal reporting of SR abstracts should be encouraged, preferably by endorsing the PRISMA for abstracts guidelines.
Resumo:
PURPOSE Confidence intervals (CIs) are integral to the interpretation of the precision and clinical relevance of research findings. The aim of this study was to ascertain the frequency of reporting of CIs in leading prosthodontic and dental implantology journals and to explore possible factors associated with improved reporting. MATERIALS AND METHODS Thirty issues of nine journals in prosthodontics and implant dentistry were accessed, covering the years 2005 to 2012: The Journal of Prosthetic Dentistry, Journal of Oral Rehabilitation, The International Journal of Prosthodontics, The International Journal of Periodontics & Restorative Dentistry, Clinical Oral Implants Research, Clinical Implant Dentistry and Related Research, The International Journal of Oral & Maxillofacial Implants, Implant Dentistry, and Journal of Dentistry. Articles were screened and the reporting of CIs and P values recorded. Other information including study design, region of authorship, involvement of methodologists, and ethical approval was also obtained. Univariable and multivariable logistic regression was used to identify characteristics associated with reporting of CIs. RESULTS Interrater agreement for the data extraction performed was excellent (kappa = 0.88; 95% CI: 0.87 to 0.89). CI reporting was limited, with mean reporting across journals of 14%. CI reporting was associated with journal type, study design, and involvement of a methodologist or statistician. CONCLUSIONS Reporting of CI in implant dentistry and prosthodontic journals requires improvement. Improved reporting will aid appraisal of the clinical relevance of research findings by providing a range of values within which the effect size lies, thus giving the end user the opportunity to interpret the results in relation to clinical practice.
Resumo:
AIM Abstracts of randomized clinical trials are extremely important as trial appraisal is often based on the information included here. The objective of this study was to assess the quality of the reporting of RCT abstracts in journals of Oral Implantology. MATERIAL AND METHODS Six leading Implantology journals were screened for RCTs between years 2008 and 2012. A 21-item modified CONSORT for abstracts checklist was used to examine the completeness of abstract reporting. Descriptive statistics and linear regression modeling were employed for data analysis. RESULTS One hundred and sixty three RCT abstracts were included in this study. The majority of the RCTs were published in the Clinical Oral Implants Research (42.9%). The mean overall reporting quality score was 58.6% (95% CI: 57.6-59.7). The highest score was noted in the European Journal of Oral Implantology (63.8%; 95% CI: 61.8-65.8). Multivariate analysis demonstrated that abstract quality score was related to publication journal and number of research centers involved. Most abstracts adequately reported interventions (89.0%), objectives (77.9%) and conclusions (74.8%) while failed to report randomization procedures, allocation concealment, effect estimate, confidence intervals, and funding. Registration of RCTs was not reported in any of the abstracts. CONCLUSIONS The reporting quality in abstracts of RCTs published in Oral Implantology journals needs to be improved. Editors and authors should be encouraged to endorse the CONSORT for abstracts guidelines in order to achieve optimal quality in abstract reporting.
Resumo:
The purpose of this study was to examine the reporting quality of randomised controlled trials (RCTs) published in prosthodontic and implantology journals. Thirty issues of nine journals in prosthodontics and implant dentistry were searched for RCTs, covering the years 2005-2012: The Journal of Prosthetic Dentistry, Journal of Oral Rehabilitation, The International Journal of Prosthodontics, The International Journal of Periodontics & Restorative Dentistry, Clinical Oral Implants Research, Clinical Implant Dentistry & Related Research, The International Journal of Oral & Maxillofacial Implants, Implant Dentistry and Journal of Dentistry. The reporting quality was assessed using a modified Consolidated Standards of Reporting Trials (CONSORT) statement checklist. Data were analysed using descriptive statistics followed by univariable and multivariable examination of statistical associations (α = 0·05). A total of 147 RCTs were identified with a mean CONSORT score of 69·4 (s.d. = 9·7). Significant differences were found among journals with the Journal of Oral Rehabilitation achieving the highest score (80·6, s.d. = 5·5) followed by Clinical Oral Implants Research (73·7, s.d. = 8·3). Involvement of a statistician/methodologist was significantly associated with increased CONSORT scores. Overall, the reporting quality of RCTs in major prosthodontic and implantology journals requires improvement. This is of paramount importance considering that optimal reporting of RCTs is an important prerequisite for clinical decision-making.
Resumo:
Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.
Resumo:
This study evaluated the biomechanical and microscopic response of previously grafted bone to titanium implants. The lower incisors of 16 rabbits were surgically extracted, and bilateral perforations communicating with the remaining sockets were created distally. A socket/perforation defect on each mandible was chosen at random to be immediately filled with a xenogenic graft, whereas the contralateral perforation was left to heal naturally and served as a paired control. After 60 days, titanium implants were installed in the previously operated areas. After periods of 2 and 6 months, the animals were killed, and the force necessary to retrieve implants as well as the bone-implant contact (BIC) and bone mass (BM) were quantified and statistically compared by 2-way analysis of variance and Tukey`s test (alpha = .05). No significant differences in removal torque were observed, either by time or by treatment condition. Differences in BIC and BM between experimental and control groups were not statistically significant through the intervals studied (P < .05). The presence of a xenogenic graft did not influence the microscopic tissue response to titanium implants or fixation into newly formed or mature bone.
Resumo:
Objective: Determine the presence of"burnout" syndrome and characteristic personality patterns in the students and faculty of three graduate programs in Dentistry at the University of Barcelona: Department of Oral Surgery and Implantology, Department of Orthodontics and Department of Integrated Dentistry. Materials and Methods: The study was carried out in 78 dentists. The level of"burnout" was evaluated using the Maslach Burnout Inventory, socio-demographic variables and, finally, the personality test. Results: Oral surgeons constituted the group of highlevel"burnout". The profile of an individual with a propensity to"burn out" is a single man, with a median age of 27, that is in the first years of the graduate program and that combines studies with 30 hours of clinical practice and/or other work (p<0,05). Narcissistic and borderline are the types of personality most frequently found in the individuals that present"burnout" syndrome (p<0,05). Conclusions: In general, no high levels of"burnout" were registered in the studied population, only 2-3%, if applying strict definition of"burnout", and 10% if these criteria were amplified. We believe it is necessary to identify the individuals with a tendency towards"burnout", in order to establish preventive measures and avoid future negative behaviour at work as well as at the personal level.