961 resultados para Implanted electrodes
Resumo:
External sources The National Institute for Health Research (NIHR), UK. This project was supported byNIHR via Cochrane Infrastructure, Cochrane Programme Grant or Cochrane Incentive funding to the Incontinence Group. The views and opinions expressed therein are those of the authors and do not necessarily reflect those of the Systematic Reviews Programme, NIHR, National Health Service (NHS) or the Department of Health. NHS Grampian Endowment Research Grants, UK. This project was also supported by NHS Grampian Endowment Research Grants.
Subthalamic nucleus deep brain stimulation for Parkinson's disease : "Are we where we think we are ?
Resumo:
ABSTRACT High frequency electrical deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a worldwide recognized therapy for the motor symptoms of Parkinson's disease in fluctuating patients who are progressively disabled despite medical treatment adjustments. However, such improvements emerge despite a lack of understanding of either the precise role of STN in human motor control or the mechanism(s) of action of DBS. Through the question "are we where we think we are", this thesis is first dedicated to the control of the position of the preoperatively defined target and of the implanted electrodes on magnetic resonance imaging (MRI). This anatomical approach will provide a way to identify more precisely the structure(s) involved by electrical stimulation. Then, a study of the correlation existing between the position of the preoperative target and the position of the electrode is performed. In this part, a unique opportunity is given to identify factors that may affect these correlation results. Finally, the whole work represents a « quality assessment » of the crucial steps of STN DBS: first, the target and the implanted electrode localisation procedures that have been developed in collaboration with the Radiological department; second the implantation procedure that has been performed nowadays on more than 50 parkinsonian patients in the Neurosurgical department of the Centre Hospitalier Universitaire Vaudois in collaboration with the Neurological department. This work is especially addressed to the multidisciplinary medical team involved in the surgical treatment of movement disorders, including also neurophysiologists, neuropsychologists and psychiatrists. RESUME La stimulation électrique à haute fréquence du noyau sous-thalamique est à ce jour mondialement reconnue pour le traitement des symptômes moteurs de la maladie de Parkinson chez des patients sévèrement atteints et chez qui la réponse fluctuante au traitement médicamenteux ne peut être améliorée de façon satisfaisante. Cependant, les résultats observés surviennent malgré une compréhension approximative et controversée du rôle réel du noyau sous-thalamique dans le contrôle du mouvement volontaire aussi bien que des mécanismes d'action de la stimulation cérébrale profonde. A travers la question « sommes-nous où nous pensons être », cette thèse est tout d'abord consacrée à l'étude du contrôle de la position de la cible définie avant l'intervention et de la position des électrodes implantées sur l'imagerie par résonance magnétique (IRM). Cette approche anatomique permettra d'identifier plus précisément la (les) structure(s) influencées par la stimulation électrique. Ensuite, une étude de la corrélation existant entre la position de la cible préopératoire et la position des électrodes implantées est effectuée. Elle a pour but de mettre en évidence les facteurs influençant les résultats de cette corrélation. Enfin, le travail dans son ensemble est un « contrôle de qualité » des étapes cruciales de la stimulation du noyau sous-thalamique : premièrement, des méthodes de localisation de la cible et des électrodes implantées effectuées sur IRM, développées en collaboration avec le service de Radiologie ; deuxièmement, de la méthode d'implantation utilisée à ce jour chez plus de 50 patients dans le service de Neurochirurgie du Centre Hospitalier Universitaire Vaudois en collaboration avec le service de Neurologie. Ce travail s'adresse spécialement aux équipes médicales pluridisciplinaires impliquées dans le traitement chirurgical des mouvements anormaux, incluant également des neurophysiologistes, des neuropsychologues et des psychiatres.
Resumo:
Limbic encephalitis (LE) with waxing and waning neuropsychiatric manifestations including behavioral, personality, psychiatric, and memory changes can evolve over days to months. Many features of LE show remarkable overlap with the characteristics of mesial-temporal (limbic) status epilepticus (MTLSE or LSE). With LE, these prolonged impaired states are assumed not to be due to ongoing epileptic activity or MTLSE, because scalp EEGs usually show no epileptiform spike-wave activity; cycling behavioral and motor changes are attributed to LE; there may be little immediate improvement with antiepileptic drugs (AEDs); and of course, implanted electrodes are rarely used. Conversely, it is known that in pre-surgical patients with refractory limbic epilepsy, implanted electrodes have revealed limbic seizures that cannot be seen at the scalp. This paper assembles a chain of inferences to advance the proposition that refractory LE might represent LSE more often than is thought, and that implanted electrodes should be considered in some cases. We present two cases that suggest that LE was also LSE, one of which warranted implanted electrodes (case 1).
Resumo:
The purpose of the present study was to modulate the secretion of insulin and glucagon in Beagle dogs by stimulation of nerves innervating the intact and partly dysfunctional pancreas. Three 33-electrode spiral cuffs were implanted on the vagus, splanchnic and pancreatic nerves in each of two animals. Partial dysfunction of the pancreas was induced with alloxan. The nerves were stimulated using rectangular, charge-balanced, biphasic, and constant current pulses (200 µs, 1 mA, 20 Hz, with a 100-µs delay between biphasic phases). Blood samples from the femoral artery were drawn before the experiment, at the beginning of stimulation, after 5 min of stimulation, and 5 min after the end of stimulation. Radioimmunoassay data showed that in the intact pancreas stimulation of the vagal nerve increased insulin (+99.2 µU/ml) and glucagon (+18.7 pg/ml) secretion and decreased C-peptide secretion (-0.15 ng/ml). Splanchnic nerve stimulation increased insulin (+1.7 µU/ml), C-peptide (+0.01 ng/ml), and glucagon (+50 pg/ml) secretion, whereas pancreatic nerve stimulation did not cause a marked change in any of the three hormones. In the partly dysfunctional pancreas, vagus nerve stimulation increased insulin (+15.5 µU/ml), glucagon (+11 pg/ml), and C-peptide (+0.03 ng/ml) secretion. Splanchnic nerve stimulation reduced insulin secretion (-2.5 µU/ml) and increased glucagon (+58.7 pg/ml) and C-peptide (+0.39 ng/ml) secretion, and pancreatic nerve stimulation increased insulin (+0.2 µU/ml), glucagon (+5.2 pg/ml), and C-peptide (+0.08 ng/ml) secretion. It was concluded that vagal nerve stimulation can significantly increase insulin secretion for a prolonged period of time in intact and in partly dysfunctional pancreas.
Resumo:
This paper explores the development of multi-feature classification techniques used to identify tremor-related characteristics in the Parkinsonian patient. Local field potentials were recorded from the subthalamic nucleus and the globus pallidus internus of eight Parkinsonian patients through the implanted electrodes of a Deep brain stimulation (DBS) device prior to device internalization. A range of signal processing techniques were evaluated with respect to their tremor detection capability and used as inputs in a multi-feature neural network classifier to identify the activity of Parkinsonian tremor. The results of this study show that a trained multi-feature neural network is able, under certain conditions, to achieve excellent detection accuracy on patients unseen during training. Overall the tremor detection accuracy was mixed, although an accuracy of over 86% was achieved in four out of the eight patients.
Resumo:
Parkinson is a neurodegenerative disease, in which tremor is the main symptom. This paper investigates the use of different classification methods to identify tremors experienced by Parkinsonian patients.Some previous research has focussed tremor analysis on external body signals (e.g., electromyography, accelerometer signals, etc.). Our advantage is that we have access to sub-cortical data, which facilitates the applicability of the obtained results into real medical devices since we are dealing with brain signals directly. Local field potentials (LFP) were recorded in the subthalamic nucleus of 7 Parkinsonian patients through the implanted electrodes of a deep brain stimulation (DBS) device prior to its internalization. Measured LFP signals were preprocessed by means of splinting, down sampling, filtering, normalization and rec-tification. Then, feature extraction was conducted through a multi-level decomposition via a wavelettrans form. Finally, artificial intelligence techniques were applied to feature selection, clustering of tremor types, and tremor detection.The key contribution of this paper is to present initial results which indicate, to a high degree of certainty, that there appear to be two distinct subgroups of patients within the group-1 of patients according to the Consensus Statement of the Movement Disorder Society on Tremor. Such results may well lead to different resultant treatments for the patients involved, depending on how their tremor has been classified. Moreover, we propose a new approach for demand driven stimulation, in which tremor detection is also based on the subtype of tremor the patient has. Applying this knowledge to the tremor detection problem, it can be concluded that the results improve when patient clustering is applied prior to detection.
Resumo:
Neocortical spindling that frequently occurs in rats during wakefulness was studied to evaluate the hypotheses that spindle bursts are either the electrophysiological manifestation of a short-lasting sleep episode that briefly interrupts wakefulness (due to an urge to sleep) or a short decrease of the vigilance level. In order to evaluate sleep need, the latency to the onset of natural sleep, the percentual composition of the sleep-wakefulness cycles, and the durations and intervals of desynchronized sleep episodes were determined in six male Wistar rats weighing 250-350 g and having chronically implanted electrodes for frontal electrocorticogram and cervical electromyogram. These animals were selected on the basis of spindling manifestation during wakefulness. The occurrence of spindling during a period of repeated painful tail-pinching was subsequently measured to determine the vigilance level in the same animals. Two rats were also studied during forced immobilization for the same purpose. Sleep parameters were found to be normal in all rats studied, thus excluding the hypothesis that spindling in wakefulness is a manifestation of a high sleep need. Spindling also occurred in both situations requiring a high level of vigilance (frequent tail-pinching and forced immobilization). Natural sleep cycles never started with this type of spindling, which is not related to the typical synchronization patterns of synchronized deep, the frequency of the potentials that make up spindles in wakefulness were systematically 1 to 2 Hz lower than those of synchronized sleep in all animals studied. The possibility that spindling during wakefulness may be associated to brief episodes of distraction is discussed.
Resumo:
Recent animal studies highlighting the relationship between functional imaging signals and the underlying neuronal activity have revealed the potential capabilities of non-invasive methods. However, the valuable exchange of information between animal and human studies remains restricted by the limited evidence of direct physiological links between species. In this study we used magnetoencephalography (MEG) to investigate the occurrence of 30-70 Hz (gamma) oscillations in human visual cortex, induced by the presentation of visual stimuli of varying contrast. These oscillations, well described in the animal literature, were observed in retinotopically concordant locations of visual cortex and show striking similarity to those found in primate visual cortex using surgically implanted electrodes. The amplitude of the gamma oscillations increases linearly with stimulus contrast in strong correlation with the gamma oscillations found in the local field potential (LFP) of the macaque. We demonstrate that non-invasive magnetic field measurements of gamma oscillations in human visual cortex concur with invasive measures of activation in primate visual cortex, suggesting both a direct representation of underlying neuronal activity and a concurrence between human and primate cortical activity. © 2005 Elsevier Inc. All rights reserved.
Resumo:
Theta rhythm consists of an electrophysiological hippocampal oscillation present in mammalian species (4-12 Hz with variations across species). This oscillation is present during active waking and is also prevalent in local field potentials (LFP) during rapid eye movement sleep (REM sleep). Several studies have shown that theta rhythm is important in cognitive tasks and that the medial septum is a key region for its occurrence. The septum sends cholinergic, GABAergic and glutamatergic projections to the hippocampus, which in turn projects axons to the septum. Besides the septum, other regions are involved in regulating theta rhythm, forming a complex network of interactions among brain areas that result in theta rhythm. Optogenetics is a recently developed method that has been widely used in various research areas. It allows us to manipulate the electrical activity of neurons through light stimulation. One of the existing techniques consists in using a viral vector to induce the neuronal expression of ion channels associated with the light-sensitive molecule rhodopsin (e.g. ChR2). Once infected, the neurons become sensitive to light of a particular wavelength. The present M. Sc. research aimed to perform luminous stimulation of the brain in anesthetized and freely behaving animals using chronically implanted electrodes and optical fibers in animals infected with a viral vector for ChR2 expression. Surgical viral injections were performed in the medial septum; histological results confirmed the expression of ChR2 by way of the presence of the eYFP reporter protein in the septum and also in hippocampal processes. Moreover, we performed acute experiments with luminous stimulation of the medial septum and LFP recordings of the septum and hippocampus of anesthetized animals. Action potentials were recorded in the septum. In these experiments we observed a significant increase in the firing rates of septal neurons during luminous stimulation (n = 300 trials). Furthermore, we found an early light-evoked response in the hippocampal LFP. Chronic experiments with luminous stimulation of the medial septum and hippocampus in freely behaving animals were also performed in combination with LFP recordings. We found that the luminous stimulation of the septum is able to induce theta rhythm in the hippocampus. Together, the results demonstrate that the luminous stimulation of the medial septum in optogenetically-modified animals causes relevant electrophysiological changes in the septum and the hippocampus.
Resumo:
OBJECTIVE Cochlear implants (CI) are standard treatment for prelingually deafened children and postlingually deafened adults. Computed tomography (CT) is the standard method for postoperative imaging of the electrode position. CT scans accurately reflect electrode depth and position, which is essential prior to use. However, routine CT examinations expose patients to radiation, which is especially problematic in children. We examined whether new CT protocols could reduce radiation doses while preserving diagnostic accuracy. METHODS To investigate whether electrode position can be assessed by low-dose CT protocols, a cadaveric lamb model was used because the inner ear morphology is similar to humans. The scans were performed at various volumetric CT dose-indexes CTDIvol)/kV combinations. For each constant CTDIvol the tube voltage was varied (i.e., 80, 100, 120 and 140kV). This procedure was repeated at different CTDIvol values (21mGy, 11mGy, 5.5mGy, 2.8mGy and 1.8mGy). To keep the CTDIvol constant at different tube voltages, the tube current values were adjusted. Independent evaluations of the images were performed by two experienced and blinded neuroradiologists. The criteria diagnostic usefulness, image quality and artifacts (scaled 1-4) were assessed in 14 cochlear-implanted cadaveric lamb heads with variable tube voltages. RESULTS Results showed that the standard CT dose could be substantially reduced without sacrificing diagnostic accuracy of electrode position. The assessment of the CI electrode position was feasible in almost all cases up to a CTDIvol of 2-3mGy. The number of artifacts did not increase for images within this dose range as compared to higher dosages. The extent of the artifacts caused by the implanted metal-containing CI electrode does not depend on the radiation dose and is not perceptibly influenced by changes in the tube voltage. Summarizing the evaluation of the CI electrode position is possible even at a very low radiation dose. CONCLUSIONS CT imaging of the temporal bone for postoperative electrode position control of the CI is possible with a very low and significantly radiation dose. The tube current-time product and voltage can be reduced by 50% without increasing artifacts. Low-dose postoperative CT scans are sufficient for localizing the CI electrode.
Resumo:
Synthesis and functionalization of large-area graphene and its structural, electrical and electrochemical properties has been investigated. First, the graphene films, grown by thermal chemical vapor deposition (CVD), contain three to five atomic layers of graphene, as confirmed by Raman spectroscopy and high-resolution transmission electron microscopy. Furthermore, the graphene film is treated with CF4 reactive-ion plasma to dope fluorine ions into graphene lattice as confirmed by X-ray photoelectron spectroscopy (XPS) and UV-photoemission spectroscopy (UPS). Electrochemical characterization reveals that the catalytic activity of graphene for iodine reduction enhanced with increasing plasma treatment time, which is attributed to increase in catalytic sites of graphene for charge transfer. The fluorinated graphene is characterized as a counter-electrode (CE) in a dye-sensitized solar cell (DSSC) which shows ~ 2.56% photon to electron conversion efficiency with ~11 mAcm−2 current density. Second, the large scale graphene film is covalently functionalized with HNO3 for high efficiency electro-catalytic electrode for DSSC. The XPS and UPS confirm the covalent attachment of C-OH, C(O)OH and NO3- moieties with carbon atoms through sp2-sp3 hybridization and Fermi level shift of graphene occurs under different doping concentrations, respectively. Finally, CoS-implanted graphene (G-CoS) film was prepared using CVD followed by SILAR method. The G-CoS electro-catalytic electrodes are characterized in a DSSC CE and is found to be highly electro-catalytic towards iodine reduction with low charge transfer resistance (Rct ~5.05 Ωcm 2) and high exchange current density (J0~2.50 mAcm -2). The improved performance compared to the pristine graphene is attributed to the increased number of active catalytic sites of G-CoS and highly conducting path of graphene. We also studied the synthesis and characterization of graphene-carbon nanotube (CNT) hybrid film consisting of graphene supported by vertical CNTs on a Si substrate. The hybrid film is inverted and transferred to flexible substrates for its application in flexible electronics, demonstrating a distinguishable variation of electrical conductivity for both tension and compression. Furthermore, both turn-on field and total emission current was found to depend strongly on the bending radius of the film and were found to vary in ranges of 0.8 - 3.1 V/μm and 4.2 - 0.4 mA, respectively.
Resumo:
TiO2 and TiO2/WO3 electrodes, irradiated by a solar simulator in configurations for heterogeneous photocatalysis (HP) and electrochemically-assisted HP (EHP), were used to remediate aqueous solutions containing 10 mg L(-1) (34 μmol L(-1)) of 17-α-ethinylestradiol (EE2), active component of most oral contraceptives. The photocatalysts consisted of 4.5 μm thick porous films of TiO2 and TiO2/WO3 (molar ratio W/Ti of 12%) deposited on transparent electrodes from aqueous suspensions of TiO2 particles and WO3 precursors, followed by thermal treatment at 450 (°)C. First, an energy diagram was organized with photoelectrochemical and UV-Vis absorption spectroscopy data and revealed that EE2 could be directly oxidized by the photogenerated holes at the semiconductor surfaces, considering the relative HOMO level for EE2 and the semiconductor valence band edges. Also, for the irradiated hybrid photocatalyst, electrons in TiO2 should be transferred to WO3 conduction band, while holes move toward TiO2 valence band, improving charge separation. The remediated EE2 solutions were analyzed by fluorescence, HPLC and total organic carbon measurements. As expected from the energy diagram, both photocatalysts promoted the EE2 oxidation in HP configuration; after 4 h, the EE2 concentration decayed to 6.2 mg L(-1) (35% of EE2 removal) with irradiated TiO2 while TiO2/WO3 electrode resulted in 45% EE2 removal. A higher performance was achieved in EHP systems, when a Pt wire was introduced as a counter-electrode and the photoelectrodes were biased at +0.7 V; then, the EE2 removal corresponded to 48 and 54% for the TiO2 and TiO2/WO3, respectively. The hybrid TiO2/WO3, when compared to TiO2 electrode, exhibited enhanced sunlight harvesting and improved separation of photogenerated charge carriers, resulting in higher performance for removing this contaminant of emerging concern from aqueous solution.
Resumo:
Two experiments evaluated an operant procedure for establishing stimulus control using auditory and electrical stimuli as a baseline for measuring the electrical current threshold of electrodes implanted in the cochlea. Twenty-one prelingually deaf children, users of cochlear implants, learned a Go/No Go auditory discrimination task (i.e., pressing a button in the presence of the stimulus but not in its absence). When the simple discrimination baseline became stable, the electrical current was manipulated in descending and ascending series according to an adapted staircase method. Thresholds were determined for three electrodes, one in each location in the cochlea (basal, medial, and apical). Stimulus control was maintained within a certain range of decreasing electrical current but was eventually disrupted. Increasing the current recovered stimulus control, thus allowing the determination of a range of electrical currents that could be defined as the threshold. The present study demonstrated the feasibility of the operant procedure combined with a psychophysical method for threshold assessment, thus contributing to the routine fitting and maintenance of cochlear implants within the limitations of a hospital setting.
Resumo:
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.
Resumo:
A modified method for the calculation of the normalized faradaic charge (q fN) is proposed. The method involves the simulation of an oxidation process, by cyclic voltammetry, by employing potentials in the oxygen evolution reaction region. The method is applicable to organic species whose oxidation is not manifested by a defined oxidation peak at conductive oxide electrodes. The variation of q fN for electrodes of nominal composition Ti/RuX Sn1-X O2 (x = 0.3, 0.2 and 0.1), Ti/Ir0.3Ti0.7O2 and Ti/Ru0.3Ti0.7O2 in the presence of various concentrations of formaldehyde was analyzed. It was observed that electrodes containing SnO2 are the most active for formaldehyde oxidation. Subsequently, in order to test the validity of the proposed model, galvanostatic electrolyses (40 mA cm-2) of two different formaldehyde concentrations (0.10 and 0.01 mol dm-3) were performed. The results are in agreement with the proposed model and indicate that this new method can be used to determine the relative activity of conductive oxide electrodes. In agreement with previous studies, it can be concluded that not only the nature of the electrode material, but also the organic species in solution and its concentration are important factors to be considered in the oxidation of organic compounds.