973 resultados para Implantable Infusion pumps


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Technology assessment is a comprehensive form of policy research that examines the short- and long-term social consequences of the application or use of technology" (US Congress 1967).^ This study explored a research methodology appropriate for technology assessment (TA) within the health industry. The case studied was utilization of external Small-Volume Infusion Pumps (SVIP) at a cancer treatment and research center. Primary and secondary data were collected in three project phases. In Phase I, hospital prescription records (N = 14,979) represented SVIP adoption and utilization for the years 1982-1984. The Candidate Adoption-Use (CA-U) diffusion paradigm developed for this study was germane. Compared to classic and unorthodox curves, CA-U more accurately simulated empiric experience. The hospital SVIP 1983-1984 trends denoted assurance in prescribing chemotherapy and concomitant balloon SVIP efficacy and efficiency. Abandonment of battery pumps was predicted while exponential demand for balloon SVIP was forecast for 1985-1987. In Phase II, patients using SVIP (N = 117) were prospectively surveyed from July to October 1984; the data represented a single episode of therapy. The questionnaire and indices, specifically designed to measure the impact of SVIP, evinced face validity. Compeer group data were from pre-SVIP case reviews rather than from an inpatient sample. Statistically significant results indicated that outpatients using SVIP interacted socially more than inpatients using the alternative technology. Additionally, the hospital's education program effectively taught clients to discriminate between self care and professional SVIP services. In these contexts, there was sufficient evidence that the alternative technology restricted patients activity whereas SVIP permitted patients to function more independently and in a social lifestyle, thus adding quality to life. In Phase III, diffusion forecast and patient survey findings were combined with direct observation of clinic services to profile some economic dimensions of SVIP. These three project phases provide a foundation for executing: (1) cost effectiveness analysis of external versus internal infusors, (2) institutional resource allocation, and (3) technology deployment to epidemiology-significant communities. The models and methods tested in this research of clinical technology assessment are innovative and do assess biotechnology. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução. Apesar das evidências dos efeitos imunomodulatórios da morfina, não há na literatura estudos que tenham comparado a interação entre citocinas, imunidade celular (linfócitos T, B e NK) e a administração prolongada de morfina administrada pelas vias oral ou intratecal em doentes com dor crônica neuropática não relacionada ao câncer. Foram avaliados de forma transversal e comparativa 50 doentes com diagnóstico de dor lombar crônica e com presença de radiculopatia (dor neuropática) previamente operados para tratar hérnia discal lombar (Síndrome Dolorosa Pós- Laminectomia), sendo 18 doentes tratados prolongadamente com infusão de morfina pela via intratecal com uso de sistema implantável no compartimento subaracnóideo (grupo intratecal); 17 doentes tratados prolongadamente com morfina pela via oral (n=17) e 15 doentes tratados com fármacos mas sem opióides (grupo sem opioide). Foram analisadas as concentração das citocinas IL-2, IL-4, IL-8, TNFalfa, IFNy, IL-5, GM-CSF, IL-6, IL-10 e IL-1beta no plasma e no líquido cefalorraquidiano; imunofenotipagem de linfócitos T, B e células NK e avaliados os Índice de Escalonamento de Opióide (em percentagem de opióide utilizada e em mg), dose cumulativa de morfina (mg), duração do tratamento em meses, dose final de morfina utilizada (em mg), e equivalente de morfina por via oral (em mg). Resultados. Não houve diferença estatisticamente significativa entre o número de linfócitos T, B e NK nos doentes com morfina administrada pelas vias IT, VO e os não usuários de morfina. Houve correlação positiva entre as concentrações de linfócitos T CD4 e o Índice de Escalonamento de Opióide (em % e mg) nos doentes tratados com morfina por via intratecal. Houve correlação negativa entre as concentrações de células NK (CD56+) e o Índice de Escalonamento de Opióide (em % e mg) nos doentes tratados com morfina por via intratecal. Houve correlação positiva entre o número de células NK (CD56+) e a dose cumulativa de morfina (em mg) administrada pelas vias intratecal e oral. Houve correlação positiva entre as concentrações de linfócitos T CD8 e a duração do tratamento em meses nos doentes tratados com morfina pela via oral. As concentrações de IL-8 e IL-1beta foram maiores no LCR do que no plasma em todos os doentes da amostra analisada. As concentrações de IFNy no LCR foram maiores nos doentes que utilizavam morfina pela via oral e nos não usuários de morfina do que nos que a utilizavam pela via intratecal. As concentrações de plasmáticas de IL-5 foram maiores nos doentes utilizavam morfina pela via oral ou intratecal do que nos que não a utilizavam. A concentração de IL-5 no LCR correlacionou-se negativamente com a magnitude da dor de acordo com a EVA nos doentes tratados com morfina pelas via oral ou intratecal. Nos doentes tratados com morfina pelas via oral ou intratecal, a concentração de IL-2 no LCR correlacionou-se positivamente com a magnitude da dor de acordo com a EVA e negativamente com o Índice de Escalonamento de Opióide (em % e mg) e a dose cumulativa de morfina (em mg). As concentrações plasmáticas de GMCSF foram maiores nos doentes utilizavam morfina pela via oral ou intratecal do que nos não a utilizavam. A concentração de TNFalfa no LCR nos doentes tratados com morfina pela via intratecal correlacionou-se negativamente com o Índice de Escalonamento de Opióide (em % e mg), a dose cumulativa de morfina (em mg) e dose equivalente por via oral (em mg) de morfina. A concentração plasmática das citocinas IL-6 e IL-10 correlacionou-se negativamente com a duração do tratamento (em meses) nos doentes tratados com morfina administrada pela via oral. O Índice de Escalonamento de Opióide (em mg e %) correlacionou-se negativamente com as concentrações no LCR de IL-2 e TNFalfa nos doentes tratados com morfina administrada pela via intratecal. O Índice de Escalonamento de Opióide (em mg e %) correlacionou-se negativamente com as concentrações no LCR de IL-2 e IL-5 nos doentes tratados com morfina administrada pela via oral. Houve correlação negativa entre a intensidade da dor de acordo com a EVA e as concentrações de IL-5 e IL-2 no LCR nos doentes tratados com morfina administrada pelas vias oral e intratecal. Houve correlação negativa entre a intensidade da dor de acordo com a EVA e as concentrações plasmáticas de IL-4 nos doentes tratados com morfina administrada pela via intratecal. Houve correlação negativa entre a intensidade da dor de acordo com a EVA e as concentrações plasmáticas de IL-1beta nos doentes tratados com morfina administrada pela via intratecal. Conclusões: Os resultados sugerem associações entre citocinas e imunidade celular (células T , B e NK) e o tratamento prolongado com morfina administrada pela via oral ou intratecal. Estes resultados podem contribuir para a compreensão da imunomodulação da morfina administrada por diferentes vias em doentes com dor neuropática crônica não oncológica . São necessários mais estudos sobre os efeitos da morfina sobre o sistema imunológico

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diabetic macular oedema (DMO) is a leading cause of vision loss in the working-age population worldwide. Corticosteroid drugs have been demonstrated to inhibit the expression of both the vascular endothelial growth factor (VEGF) gene and other anti-inflammatory mediators, such as prostaglandins. Triamcinolone, fluocinolone and dexamethasone are the main steroids that have been studied for the treatment of macular oedema. Over the last few years, several studies have suggested an important role for dexamethasone in the management of DMO. The dexamethasone intravitreal implant (DEX implant) (Ozurdex®; Allergan, Inc., Irvine, CA) is a novel approach approved by the US Food and Drug Administration (FDA) and by the EU for the intravitreal treatment of macular oedema after branch or central retinal vein occlusion, and for the treatment of non-infectious uveitis affecting the posterior segment of the eye. We reviewed manuscripts that had investigated the pharmacokinetics, efficacy and safety of the DEX implant regarding DMO treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND:   Complications associated with intrathecal pumps may be linked to the surgical procedure, the implanted device, or the medication itself.¦CASE REPORTS:   Three patients treated chronically with intrathecal clonidine presented with clonidine overdose due to inadvertent extravasation during the refilling procedure. All patients experienced loss of consciousness and severe systemic hypertension that required aggressive parenteral treatment.¦DISCUSSION:   Clonidine is an alpha-2 agonist with a nearly 100% bioavailability after oral or rectal administration. With high plasma concentration secondary to massive systemic overdose, the specificity for the alpha-2 receptor is lost and an alpha-1 agonist activity predominates and causes marked hypertension. Management of clonidine overdose consists of supportive therapy guided by signs and symptoms.¦CONCLUSION:   Inadvertent injection into the subcutaneous pocket rather than the reservoir is rare but very dangerous as the drug cannot be retrieved and massive doses are involved. Signs and symptoms of systemic overdose with drugs commonly used in implanted drugs delivery system should be well known to ensure early diagnosis and treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether infusion line compliance contributes to irregular drug delivery during vertical displacement of syringe pumps. DESIGN: Five different commercially available infusion lines were studied at infusion rates of 0.5, 1.0, and 1.5 ml/h. Zero drug delivery time was measured after acute line loop formation (70 cm) using an electronic balance. Compliance of each infusion line was calculated using a pressure transducer and measurement of the occlusion release bolus at 300 mmHg occlusion pressure. Finally, the influence of infusion line compliance on drug delivery during acute lowering of the syringe pump was studied using low- and high-compliance infusion lines. RESULTS: Acute line loop formation resulted in zero drug delivery time from 5.1 +/- 1.5 to 44.0 +/- 6.8 s at flow rates of 0.5 ml/h. Increased flow rates significantly reduced loop-induced flow variability. A close correlation was found between zero drug delivery time and calculated infusion line compliance at 0.5 ml/h (linear regression R2 = 0.79). Lowering of the syringe pump 50 cm prolonged zero drug delivery time from 295.8 +/- 20.7 s with the low-compliance tube to 463.3 +/- 24.0 s with the high-compliance infusion line. CONCLUSIONS: Infusion line compliance contributes to irregular drug delivery associated with vertical displacement of syringe pumps. Siphoning of the infusion line during patient care should be avoided, and flow rates of 1 ml/h or higher are recommended. Low-compliance infusion lines are indicated whenever highly short-acting vasoactive drugs at low delivery rates are administered.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Studies in cocaine-dependent human subjects have shown differences in white matter on diffusion tensor imaging (DTI) compared with non-drug-using controls. It is not known whether the differences in fractional anisotropy (FA) seen on DTI in white matter regions of cocaine-dependent humans result from a pre-existing predilection for drug use or purely from cocaine abuse. To study the effect of cocaine on brain white matter, DTI was performed on 24 rats after continuous infusion of cocaine or saline for 4 weeks, followed by brain histology. Voxel-based morphometry analysis showed an 18% FA decrease in the splenium of the corpus callosum (CC) in cocaine-treated animals relative to saline controls. On histology, significant increase in neurofilament expression (125%) and decrease in myelin basic protein (40%) were observed in the same region in cocaine-treated animals. This study supports the hypothesis that chronic cocaine use alters white matter integrity in human CC. Unlike humans, where the FA in the genu differed between cocaine users and non-users, the splenium was affected in rats. These differences between rodent and human findings could be due to several factors that include differences in the brain structure and function between species and/or the dose, timing, and duration of cocaine administration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

One of the challenges to biomedical engineers proposed by researchers in neuroscience is brain machine interaction. The nervous system communicates by interpreting electrochemical signals, and implantable circuits make decisions in order to interact with the biological environment. It is well known that Parkinson’s disease is related to a deficit of dopamine (DA). Different methods has been employed to control dopamine concentration like magnetic or electrical stimulators or drugs. In this work was automatically controlled the neurotransmitter concentration since this is not currently employed. To do that, four systems were designed and developed: deep brain stimulation (DBS), transmagnetic stimulation (TMS), Infusion Pump Control (IPC) for drug delivery, and fast scan cyclic voltammetry (FSCV) (sensing circuits which detect varying concentrations of neurotransmitters like dopamine caused by these stimulations). Some softwares also were developed for data display and analysis in synchronously with current events in the experiments. This allowed the use of infusion pumps and their flexibility is such that DBS or TMS can be used in single mode and other stimulation techniques and combinations like lights, sounds, etc. The developed system allows to control automatically the concentration of DA. The resolution of the system is around 0.4 µmol/L with time correction of concentration adjustable between 1 and 90 seconds. The system allows controlling DA concentrations between 1 and 10 µmol/L, with an error about +/- 0.8 µmol/L. Although designed to control DA concentration, the system can be used to control, the concentration of other substances. It is proposed to continue the closed loop development with FSCV and DBS (or TMS, or infusion) using parkinsonian animals models.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Prolonged infusions have been shown to be safer and potentially more effective than bolus regimens of 5-fluorouracil (5-FU) as treatment for metastatic colorectal cancer (mCRC). However, infusional 5-FU requires central venous access and costly infusion pumps. Oral fluoropyrimidines enable longer exposures to 5-FU with increased convenience. Tegafur - uracil (UFT) with leucovorin (LV) given thrice daily has improved safety plus comparable survival and response rates to bolus 5-FU/LV. We conducted a phase II clinical study in 98 patients with mCRC to evaluate if UFT with LV given twice daily provided comparable time to progression ( TTP), efficacy and tolerability to that reported for thrice daily in two phase III clinical studies. Secondary objectives included overall response rate ( ORR) and overall survival ( OS). Median TTP was 3.8 months, when compared with 3.5 months for thrice daily. The ORR ( 11%) and median OS ( 12.8 months) with twice daily administration were similar to that of thrice daily administration ( 12% and 12.4 months). The incidence of grade 3/4 treatment-related diarrhoea was 30% on the twice daily and 21% on the thrice daily schedule. These results suggest that twice daily administration has similar efficacy and tolerability to thrice daily administration and is an acceptable alternative for patients who would benefit from UFT with LV therapy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

LB11058 is a new synthetic cephalosporin with good affinity for staphylococcal penicillin-binding protein 2a (PBP2a). LB11058 was tested in vitro and in rats with experimental aortic endocarditis against three methicillin-resistant Staphylococcus aureus (MRSA) strains, one penicillinase-negative strain (strain COL), and two penicillinase-producing strains (COL-Bla+ and P8-Hom). The MICs of LB11058 for the organisms were 1 mg/liter. The MICs of vancomycin and ceftriaxone were 1 and >/=64 mg/liter, respectively. In population analysis profiles, none of the MRSA strains grew at >/=2 mg of LB11058/liter. Rats with endocarditis were treated for 5 days. LB11058 was highly bound to serum proteins in rats (>/=98%). However, binding was saturable above a threshold of 250 mg/liter. Therefore, continuous concentrations of 250 mg/liter in serum were infused to ensure a free fraction (>/=5 mg/liter) above the drug's MIC for the entire infusion period. Control treatments included simulation of human serum kinetics produced by intravenous vancomycin (1 g twice daily, free drug concentration above MIC, >/=90% of infusion period) or ceftriaxone (2 g/24 h, free drug concentrations above the MIC, 0% of infusion period). LB11058 successfully treated 10 of 10 (100%) and 13 of 14 (93%) of rats infected with COL-Bla+ and P8-Hom, respectively. This was comparable to vancomycin (sterilization of 8 of 12 [66%] and 6 of 8 [75%] rats, respectively). Ceftriaxone was inactive. Low concentrations of LB11058 (5 and 10 mg/liter, continuously infused) in serum were ineffective, as predicted by the pharmacodynamic parameters. At appropriate doses, LB11058 was highly effective both in vitro and in vivo. This finding supports the development of this beta-lactam with high PBP2a affinity for the treatment of MRSA infections.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O número de artroplastia total de quadril (ATQ) bilateral tem aumentado a cada ano. Analgesia pós-operatória pela infusão contínua perineural com anestésico local tem se mostrado favorável quando comparada com analgesia sistêmica. O uso de bombas elastoméricas tem aumentado a satisfação do paciente quando em comparação com os modelos eletrônicos. O objetivo deste relato foi descrever um caso de analgesia contínua bilateral do plexo lombar via posterior, com infusão contínua através de bomba elastomérica, em paciente submetido à uma artroplastia bilateral de quadril. RELATO do CASO: Paciente feminina, 46 anos, 65 kg, 162 cm, com artrite reumatoide e hipertensão arterial, estado físico ASA II, escalada para ser submetida a ATQ bilateral em um único estágio. Uso de corticosteroide por 13 anos. Hemoglobina = 10,1 g.dL-1, hematócrito = 32,7%. Monitoração de rotina. Raquianestesia com 15 mg de bupivacaína 0,5% isobárica. Anestesia geral com propofol (PFS) e remifentanil e intubação sem bloqueadores neuromusculares. ATQ direita e no final, bloqueio plexo lombar com estimulador e conjunto agulha 150 mm e injeção de 20 mL bupivacaína 0,2% e passagem de cateter. ATQ esquerda e, no final, mesmo procedimento. Estudado dispersão do anestésico e contraste. Instalado bomba elastomérica com bupivacaína 0,1% (400 mL) em velocidade de 14 mL.h-1. Transferida para Unidade de Cuidados Intensivos (UCI). Vinte e quatro horas após, nova bomba com a mesma solução. Nenhum bolus durante 50 horas. Após remoção de cateter, dor controlada por via oral com cetoprofeno e dipirona. CONCLUSÕES: O bloqueio bilateral contínuo periférico com infusão de bupivacaína a 0,1% com bombas elastoméricas é um procedimento seguro e efetivo em adultos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper introduces an extended hierarchical task analysis (HTA) methodology devised to evaluate and compare user interfaces on volumetric infusion pumps. The pumps were studied along the dimensions of overall usability and propensity for generating human error. With HTA as our framework, we analyzed six pumps on a variety of common tasks using Norman’s Action theory. The introduced method of evaluation divides the problem space between the external world of the device interface and the user’s internal cognitive world, allowing for predictions of potential user errors at the human-device level. In this paper, one detailed analysis is provided as an example, comparing two different pumps on two separate tasks. The results demonstrate the inherent variation, often the cause of usage errors, found with infusion pumps being used in hospitals today. The reported methodology is a useful tool for evaluating human performance and predicting potential user errors with infusion pumps and other simple medical devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Healthcare has been slow in using human factors principles to reduce medical errors. The Center for Devices and Radiological Health (CDRH) recognizes that a lack of attention to human factors during product development may lead to errors that have the potential for patient injury, or even death. In response to the need for reducing medication errors, the National Coordinating Council for Medication Errors Reporting and Prevention (NCC MERP) released the NCC MERP taxonomy that provides a standard language for reporting medication errors. This project maps the NCC MERP taxonomy of medication error to MedWatch medical errors involving infusion pumps. Of particular interest are human factors associated with medical device errors. The NCC MERP taxonomy of medication errors is limited in mapping information from MEDWATCH because of the focus on the medical device and the format of reporting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Continuous subcutaneous insulin infusion (CSII) treatment among children with type 1 diabetes is increasing in Sweden. However, studies evaluating glycaemic control in children using CSII show inconsistent results. Omitting bolus insulin doses using CSII may cause reduced glycaemic control among adolescents. The distribution of responsibility for diabetes self-management between children and parents is often unclear and needs clarification. There is much published support for continued parental involvement and shared diabetes management during adolescence. Guided Self-Determination (GSD) is an empowerment-based, person-centred, reflection and problem solving method intended to guide the patient to become self-sufficient and develop life skills for managing difficulties in diabetes self-management. This method has been adapted for adolescents and parents as Guided Self-Determination-Young (GSD-Y). This study aims to evaluate the effect of an intervention with GSD-Y in groups of adolescents starting on insulin pumps and their parents on diabetes-related family conflicts, perceived health and quality of life (QoL), and metabolic control. Here, we describe the protocol and plans for study enrolment. Methods. This study is designed as a randomized, controlled, prospective, multicentre study. Eighty patients between 12-18 years of age who are planning to start CSII will be included. All adolescents and their parents will receive standard insulin pump training. The education intervention will be conducted when CSII is to be started and at four appointments in the first 4 months after starting CSII. The primary outcome is haemoglobin A1c levels. Secondary outcomes are perceived health and QoL, frequency of blood glucose self-monitoring and bolus doses, and usage of carbohydrate counting. The following instruments will be used to evaluate perceived health and QoL: Disabkids, 'Check your health', the Diabetes Family Conflict Scale and the Swedish Diabetes Empowerment Scale. Outcomes will be evaluated within and between groups by comparing data at baseline, and at 6 and 12 months after starting treatment. Results and discussion. In this study, we will assess the effect of starting an insulin pump together with the model of Guided Self-Determination to determine whether this approach leads to retention of improved glycaemic control, QoL, responsibility distribution and reduced diabetes-related conflicts in the family. Trial registration: Current controlled trials: ISRCTN22444034