241 resultados para Implantable


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study described the formulation and characterisation of the viscoelastic, mechanical and mucoadhesive properties of thermoresponsive, binary polymeric systems composed of poloxamer (P407) and poly(acrylic acid, C974P) that were designed for use as a drug delivery platform within the oral cavity. Monopolymeric and binary polymeric formulations were prepared containing 10, 15 and 20% (w/w) poloxamer (407) and 0.10-0.25% (w/w) poly(acrylic acid, 934P). The flow theological and viscoelastic properties of the formulations were determined using controlled stress and oscillatory rheometry, respectively, the latter as a function of temperature. The mechanical and mucoadhesive properties (namely the force required to break the bond between the formulation and a pre-hydrated mucin disc) were determined using compression and tensile analysis, respectively. Binary systems composed of 10% (w/w) P407 and C934P were elastoviscous, were easily deformed under stress and did not exhibit mucoadhesion. Formulations containing 15 or 20% (w/w) Pluronic P407 and C934P exhibited a sol-gel temperature T(sol/gel), were viscoelastic and offered high elasticity and resistance to deformation at 37 degrees C. Conversely these formulations were elastoviscous and easily deformed at temperatures below the sol-gel transition temperature. The sol-gel transition temperatures of systems containing 15% (w/w) P407 were unaffected by the presence of C934P; however, increasing the concentration of C934P decreased the T(sol/gel) in formulations containing 20%(w/w) P407. Rheological synergy between P407 and C934P at 37 degrees C was observed and was accredited to secondary interactions between these polymers, in addition to hydrophobic interactions between P407 micelles. Importantly, formulations composed of 20% (w/w) P407 and C934P exhibited pronounced mucoadhesive properties. The ease of administration (below the T(sol/gel)) in conjunction with the viscoelastic (notably high elasticity) and mucoadhesive properties (at body temperature) render the formulations composed of 20% (w/w) P407 and C934P as potentially useful platforms for mucoadhesive, controlled topical drug delivery within the oral cavity. (c) 2009 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods: We assessed the outcome of 56 patients with Chagas` cardiomyopathy ([31 men]; mean age of 55 years; mean left ventricular ejection fraction [LVEF] 42%) presenting with either sustained ventricular tachycardia (VT) or nonsustained VT (NSVT), before therapy with implantable cardioverter-defibrillator was available at our center. Results: Over a mean follow-up of 38 +/- 16 months (range, 1-61 months), 16 patients (29%) died, 11 due to sudden cardiac death (SCD), and five from progressive heart failure. Survivors and nonsurvivors had comparable baseline characteristics, except for a lower LVEF (46 +/- 7% vs 31 +/- 9%, P < 0.001) and a higher New York Heart Association class (P = 0.003) in those who died during follow-up. Receiver-operator characteristic curve analysis showed that an LVEF cutoff value of 38% had the best accuracy for predicting all-cause mortality and an LVEF cutoff value of 40% had the best accuracy for prediction of SCD. Using the multivariate Cox regression analysis, LVEF < 40% was the only predictor of all-cause mortality (hazard ratio [HR] 12.22, 95% confidence interval [CI] 3.46-43.17, P = 0.0001) and SCD (HR 6.58, 95% CI 1.74-24.88, P = 0.005). Conclusions: Patients with Chagas` cardiomyopathy presenting with either sustained VT or NSVT run a major risk for mortality when had concomitant severe or even moderate LV systolic dysfunction. (PACE 2011; 54-62).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El desfibril•lador automàtic implantable evita la mort sobtada en prevenció secundària mentre que el benefici en prevenció primària és més discutit. L’objectiu del treball és conèixer la utilitat d’aquests aparells comparant prevenció primària i secundària. Des de l’any 2000 fins al 2008, s’han estudiat pacients amb miocardiopatia isquèmica i dilatada als que implantaven un desfibril•lador tant per prevenció primària i secundària. S’ha observat una infrautilització dels desfibril•ladors en la prevenció primària, però sobretot a la inclusió de pacients amb indicació MADIT II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. OBJECTIVES: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. DESIGN, SETTING, AND PATIENTS: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. MAIN OUTCOME MEASURES: In-hospital and 1-year mortality. RESULTS: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). CONCLUSIONS: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Many patients with an implantable cardioverter-defibrillator (ICD) have indications for magnetic resonance imaging (MRI). However, MRI is generally contraindicated in ICD patients because of potential risks from hazardous interactions between the MRI and ICD system. OBJECTIVE: The purpose of this study was to use preclinical computer modeling, animal studies, and bench and scanner testing to demonstrate the safety of an ICD system developed for 1.5-T whole-body MRI. METHODS: MRI hazards were assessed and mitigated using multiple approaches: design decisions to increase safety and reliability, modeling and simulation to quantify clinical MRI exposure levels, animal studies to quantify the physiologic effects of MRI exposure, and bench testing to evaluate safety margin. RESULTS: Modeling estimated the incidence of a chronic change in pacing capture threshold >0.5V and 1.0V to be less than 1 in 160,000 and less than 1 in 1,000,000 cases, respectively. Modeling also estimated the incidence of unintended cardiac stimulation to occur in less than 1 in 1,000,000 cases. Animal studies demonstrated no delay in ventricular fibrillation detection and no reduction in ventricular fibrillation amplitude at clinical MRI exposure levels, even with multiple exposures. Bench and scanner testing demonstrated performance and safety against all other MRI-induced hazards. CONCLUSION: A preclinical strategy that includes comprehensive computer modeling, animal studies, and bench and scanner testing predicts that an ICD system developed for the magnetic resonance environment is safe and poses very low risks when exposed to 1.5-T normal operating mode whole-body MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Port-a-Cath© (PAC) are totally implantable devices that offer an easy and long term access to venous circulation. They have been extensively used for intravenous therapy administration and are particularly well suited for chemotherapy in oncologic patients. Previous comparative studies have shown that these devices have the lowest catheter-related bloodstream infection rates among all intravascular access systems. However, bloodstream infection (BSI) still remains a major issue of port use and epidemiology data for PAC-associated BSI (PABSI) rates differ strongly depending on studies. Also, current literature about PABSI risk factors is scarce and sometimes controversial. Such heterogeneity may depend on type of studied population and local factors. Therefore, the aim of this study was to describe local epidemiology and risk factors for PABSI in adult patients in our tertiary- care university hospital. We conducted a retrospective cohort study in order to describe local epidemiology. We also performed a nested case-control study to identify local risk factors of PABSI. We analyzed medical files of adult patients who had a PAC implanted between January 1st, 2008 and December 31st, 2009 and looked for PABSI occurrence before May 1st, 2011 to define cases. Thirty nine PABSI occurred in this population with an attack rate of 5.8%. We estimated an incidence rate of 0.08/1000 PAC-days using the case-control study. PABSI causative agents were mainly Gram positive cocci (62%). We identified three predictive factors of PABSI by multivariate statistical analysis: neutropenia on outcome date (Odds Ratio [OR]: 4.05; 95% confidence interval [CI]:1.05- 15.66; p=0.042), diabetes (OR: 11.53; 95% CI: 1.07-124.70; p=0.044) and having another infection than PABSI on outcome date (OR: 6.35; 95% CI: 1.50-26.86; p=0.012). Patients suffering from acute or renal failure (OR: 4.26; 95% CI: 0.94-19.21; p=0.059) or wearing another invasive device (OR: 2.99; 95%CI:0.96-9.31; p=0.059) did not have a statistically increased risk for developing a PABSI according to classical threshold (p<0.05) but nevertheless remained close to significance. Our study demonstrated that local epidemiology and microbiology of PABSI in our institution was similar to previous reports. A larger prospective study is required to confirm our results or to test preventive measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mise au point sur le hotter implantable (Reveal®). Connaissances actuelles et implications thérapeutiques. La syncope est un problème fréquent touchant environ un tiers des adultes durant leur vie. C'est un motif de consultation habituel aux urgences et ses causes sont souvent multiples et rendent son diagnostic difficile. Malgré des investigations extensives et coûteuses la cause syncopale reste dans environ 30% des cas d'étiologie indéterminée. Les progrès récents dans le monitoring cardiaque à long terme ont permis d'inclure dans le choix des tests diagnostiques un outil très intéressant dans l'investigation de la syncope d'étiologie indéterminée (SOI). Il s'agit du moniteur ECG implantable (MEI) ou Reveal®. Il y a un peu plus de 10 ans un prototype de MEI a été implanté dans un petit collectif de patients souffrants de SOI récidivantes et a permis d'établir un diagnostic chez la plupart d'entre eux. Dès lors le système s'est modernisé avec une diminution importante de la taille et du poids permettant actuellement d'enregistrer le rythme cardiaque sur une durée de 18 à 24 mois. Le système peut stocker dans sa mémoire un tracé ECG soit à l'aide d'un activateur externe déclenché par le patient, soit de façon spontanée en présence d'un rythme cardiaque lent ou rapide. Son implantation se fait en anesthésie locale, en position sous-cutanée pectorale gauche. Les complications et les problèmes infectieux sont rares. Plusieurs études récentes se sont intéressées à l'apport diagnostique du MEI dans la prise en charge de la SOI. La plus grande porte sur un collectif de 206 patients. L'apport diagnostique des différentes études varie de 40% à 64%. Cependant la plupart de ces études ne comportaient pas de prise en charge standardisée ou avaient des critères d'inclusion précis. Nous nous sommes intéressés aux résultats de notre prise en charge de la syncope au cours de ces 6 dernières années. Une consultation spécialisée de la syncope a été mise en place en 1999. La consultation offre l'accès à tout le plateau technique propre à l'investigation de syncopes à savoir un tilt-test avec mesure continue non invasive de la pression artérielle, examens échocardiographiques et test d'effort. Si nécessaire, le bilan peut être complété par une étude électrophysiologique (EEP) et/ou une coronarographie: Tous les patients bénéficient d'une anamnèse ciblée suivi d'un examen clinique et d'un électrocardiogramme. Une échocardiographie n'est effectuée qu'en cas de suspicion de cardiopathie sous-jacente. Un holter ou R-test ne sont réalisés qu'en présence de syncopes ou palpitations fréquentes. Les investigations se poursuivent par un tilt test suivi d'un massage du sinus carotidien en position debout et couchée. Un test d'hyperventilation n'est pratiqué que chez les patients avec traits phobiques, dépressifs ou troubles de type panique. L'EEP n'est pratiquée que chez les patients dont la syncope reste d'étiologie indéterminée après investigations initiales et chez ceux souffrant d'une cardiopathie sous jacente documentée ; elle est aussi indiquée chez ceux dont le coeur est normal mais chez qui la syncope est associée à des traumatismes ou à l'origine d'un accident de voiture. Le MEI est proposé lorsque toutes les investigations initiales restent négatives, généralement chez les sujets ayant souffert de plus d'une syncope ou de complications sérieuses. Notre expérience pratique d'une consultation de la syncope ouverte au tout venant nous montre qu'une prise en charge standardisée non invasive permet d'identifier une cause syncopale chez plus de 60% des patients. Chez les patients souffrant de syncopes récidivantes ou traumatiques d'étiologie indéterminée après investigations conventionnelles, l'apport diagnostique du MEI est élevé (64%) durant un suivi moyen de 9 mois, ce qui permet d'identifier certaines causes syncopales écartées précédemment par des tests ciblés. Parmi ces dernières, retenons plus particulièrement les tachycardies nodales et crises d'épilepsie.