912 resultados para Imageamento Elétrico 3D
Resumo:
Este trabalho mostra os resultados obtidos com ensaios geofísicos realizados em uma área contaminada por hidrocarboneto no Polo Industrial de Cubatão - São Paulo, com objetivo de caracterizar as anomalias geoelétricas associadas à presença dos hidrocarbonetos, bem como delimitar e cubar tais anomalias. Para tanto, utilizou-se o método da eletrorresistividade, por meio das técnicas de Sondagem Elétrica Vertical (SEV) e Imageamento Elétrico 3D. Os resultados obtidos permitem indicar que a presença de hidrocarboneto está associada a anomalias condutivas devido aos produtos da biodegradação. As anomalias condutivas ocorrem de forma disseminada na área, totalizando um volume de 1365,3 m³; entretanto, este volume corresponde somente à presença de contaminante em fase residual.
Resumo:
Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.
Resumo:
In this paper we present the methodological procedures involved in the digital imaging in mesoscale of a block of travertines rock of quaternary age, originating from the city of Acquasanta, located in the Apennines, Italy. This rocky block, called T-Block, was stored in the courtyard of the Laboratório Experimental Petróleo "Kelsen Valente" (LabPetro), of Universidade Estadual de Campinas (UNICAMP), so that from it were performed Scientific studies, mainly for research groups universities and research centers working in brazilian areas of reservoir characterization and 3D digital imaging. The purpose of this work is the development of a Model Solid Digital, from the use of non-invasive techniques of digital 3D imaging of internal and external surfaces of the T-Block. For the imaging of the external surfaces technology has been used LIDAR (Light Detection and Range) and the imaging surface Interior was done using Ground Penetrating Radar (GPR), moreover, profiles were obtained with a Gamma Ray Gamae-spectômetro laptop. The goal of 3D digital imaging involved the identification and parameterization of surface geological and sedimentary facies that could represent heterogeneities depositional mesoscale, based on study of a block rocky with dimensions of approximately 1.60 m x 1.60 m x 2.70 m. The data acquired by means of terrestrial laser scanner made available georeferenced spatial information of the surface of the block (X, Y, Z), and varying the intensity values of the return laser beam and high resolution RGB data (3 mm x 3 mm), total points acquired 28,505,106. This information was used as an aid in the interpretation of radargrams and are ready to be displayed in rooms virtual reality. With the GPR was obtained 15 profiles of 2.3 m and 2 3D grids, each with 24 sections horizontal of 1.3 and 14 m vertical sections of 2.3 m, both the Antenna 900 MHz to about 2600 MHz antenna. Finally, the use of GPR associated with Laser Scanner enabled the identification and 3D mapping of 3 different radarfácies which were correlated with three sedimentary facies as had been defined at the outset. The 6 profiles showed gamma a low amplitude variation in the values of radioactivity. This is likely due to the fact of the sedimentary layers profiled have the same mineralogical composition, being composed by carbonate sediments, with no clay in siliciclastic pellitic layers or other mineral carrier elements radioactive
Resumo:
The aim of this work was to describe the methodological procedures that were mandatory to develop a 3D digital imaging of the external and internal geometry of the analogue outcrops from reservoirs and to build a Virtual Outcrop Model (VOM). The imaging process of the external geometry was acquired by using the Laser Scanner, the Geodesic GPS and the Total Station procedures. On the other hand, the imaging of the internal geometry was evaluated by GPR (Ground Penetrating Radar).The produced VOMs were adapted with much more detailed data with addition of the geological data and the gamma ray and permeability profiles. As a model for the use of the methodological procedures used on this work, the adapted VOM, two outcrops, located at the east part of the Parnaiba Basin, were selected. On the first one, rocks from the aeolian deposit of the Piaui Formation (Neo-carboniferous) and tidal flat deposits from the Pedra de Fogo Formation (Permian), which arises in a large outcrops located between Floriano and Teresina (Piauí), are present. The second area, located at the National Park of Sete Cidades, also at the Piauí, presents rocks from the Cabeças Formation deposited in fluvial-deltaic systems during the Late Devonian. From the data of the adapted VOMs it was possible to identify lines, surfaces and 3D geometry, and therefore, quantify the geometry of interest. Among the found parameterization values, a table containing the thickness and width, obtained in canal and lobes deposits at the outcrop Paredão and Biblioteca were the more relevant ones. In fact, this table can be used as an input for stochastic simulation of reservoirs. An example of the direct use of such table and their predicted radargrams was the identification of the bounding surface at the aeolian sites from the Piauí Formation. In spite of such radargrams supply only bi-dimensional data, the acquired lines followed of a mesh profile were used to add a third dimension to the imaging of the internal geometry. This phenomenon appears to be valid for all studied outcrops. As a conclusion, the tool here presented can became a new methodology in which the advantages of the digital imaging acquired from the Laser Scanner (precision, accuracy and speed of acquisition) were combined with the Total Station procedure (precision) using the classical digital photomosaic technique
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Este estudo foi realizado na Área de Depósito de Rejeitos Sólidos (ADRS) da ALBRAS (Alumínio Brasileiro S.A.), localizada no município de Barcarena, Estado do Pará. Os resultados alcançados permitiram estabelecer um padrão de caracterização da subsuperfície, a partir de medidas geofísicas, fornecendo informações sobre as camadas geológicas e sobre parâmetros hidrogeológicos, tais como direção e velocidade do fluxo subterrâneo. Na realização do trabalho foram utilizados três métodos geofísicos: os métodos elétricos (Potencial Espontâneo e Eletrorresitividade) e eletromagnético (Slingram). A distribuição dos potenciais medidos através do Método do Potencial Espontâneo indicaram o sentido do fluxo subterrâneo local. Durante o estudo, foi montado um experimento de infiltração de solução salina no solo e seu efeito foi monitorado através de imageamento elétrico. Esse experimento permitiu que se estimasse a velocidade e o sentido do fluxo subterrâneo local ao longo da linha de imageamento. Os modelos interpretativos obtidos através da inversão de dados de resistividade aparente obtidos em sondagens elétricas verticais apresentaram uma boa correlação com perfis de raios gama corridos em poços tubulares da área de estudo. Estas Sondagens Elétricas Verticais permitiram que se detalhasse as unidades litológicas rasas através da estimativa de seus valores de resistividade e espessura. A interpretação dos dados eletromagnéticos através da análise de perfis de medidas, sondagens eletromagnéticas e mapas de contornos permitiu identificar a presença de zonas mais condutivas (material argiloso) e zonas mais resistivas (material arenoso). Além disso, observou-se que o mapa de contornos para a freqüência de 14080 Hz apresentou uma boa correlação com o mapa de contornos do Potencial Espontâneo referente a mesma área.
Resumo:
O município de Porto Velho (RO) gera em torno de 220 toneladas de lixo urbano por dia, os quais são dispostos em área de “lixeira” desde 1993. Este trabalho apresenta os resultados da aplicação do método geofísico da eletrorresistividade, através das técnicas da sondagem elétrica vertical e imageamento elétrico (arranjos Schlumberger e dipolo-dipolo) que foram executadas na área da lixeira da cidade de Porto Velho (RO), com o objetivo de identificar a contaminação do solo e das águas subterrâneas. A geologia sobre a qual está assentado o aterro de Porto Velho é constituída por sedimentos do pleistoceno (argilo-arenosos com concreções lateríticas) assentados sobre rochas graníticas – fraturadas - da Formação Santo Antônio. Palavras-chave: Eletrorresistividade, imageamento elétrico, sondagem elétrica vertical, resíduos sólidos urbanos.