932 resultados para Illinois School for the Visually Impaired


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to identify, describe, and analyse strategies used by a teacher to support the mobility of students with visual impairment in various school environments. A female student with visual impairment in Brazil, aged 5 years, and her classroom teacher participated in the study. Their interactions were videotaped, and later, their dialogue and actions were transcribed. Six themes of analysis were elaborated, one for each support strategy used by the teacher. The results revealed that the strategies employed by the teacher often hampered the child’s orientation and mobility. This was probably the result of a lack of assistance by professionals specialised in Orientation and Mobility, as stipulated in Brazilian legislation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSES: To describe and interpret teachers' opinions about and responsiveness to guidance on optical aids for low vision. METHODS: It was conducted a cross-sectional analytical study. The convenience, non-random sample consisted of 58 teachers from the public school network of the city of Campinas. It was constructed and applied a structured questionnaire, available online at the assessed website. For qualitative data collection it was conducted an exploratory study using the focus group technique. RESULTS: Responses expressed, for the most part, a marked interest in the website, its easiness of access, and the comprehensive nature of the information provided. Most people reported frequent use of the Internet to seek information, and found it easier to access the Internet at home. Among the qualitative aspects of the evaluation, we should mention the perceived importance of the website as a source of information, despite some criticism about the accessibility and reliability of the information found on the Internet. CONCLUSION: Teachers' need for training to deal with visually impaired students and their positive response to advice and information lead to the conclusion that web-based guidelines on the use of optical aids were considered beneficial to ease the understanding of visual impairment and the rehabilitation of the affected subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on the findings of a study on improving interaction design for visually impaired students, focusing upon the cognitive criteria for information visualisation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE:

This study explored the gaze patterns of fully sighted and visually impaired subjects during the high-risk activity of crossing the street.

METHODS:

Gaze behavior of 12 fully sighted subjects, nine with visual impairment resulting from age-related macular degeneration and 12 with impairment resulting from glaucoma, was monitored using a portable eye tracker as they crossed at two unfamiliar intersections.

RESULTS:

All subject groups fixated primarily on vehicles and crossing elements but changed their fixation behavior as they moved from "walking to the curb" to "standing at the curb" and to "crossing the street." A comparison of where subjects fixated in the 4-second time period before crossing showed that the fully sighted who waited for the light to change fixated on the light, whereas the fully sighted who crossed early fixated primarily on vehicles. Visually impaired subjects crossing early or waiting for the light fixate primarily on vehicles.

CONCLUSIONS:

Vision status affects fixation allocation while performing the high-risk activity of street crossing. Crossing decision-making strategy corresponds to fixation behavior only for the fully sighted subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present a real-time obstacle detection system for the mobility improvement for the visually impaired using a handheld Smartphone. Though there are many existing assistants for the visually impaired, there is not a single one that is low cost, ultra-portable, non-intrusive and able to detect the low-height objects on the floor. This paper proposes a system to detect any objects attached to the floor regardless of their height. Unlike some existing systems where only histogram or edge information is used, the proposed system combines both cues and overcomes some limitations of existing systems. The obstacles on the floor in front of the user can be reliably detected in real time using the proposed system implemented on a Smartphone. The proposed system has been tested in different types of floor conditions and a field trial on five blind participants has been conducted. The experimental results demonstrate its reliability in comparison to existing systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The filling of printed forms has always been an issue for the visually impaired. Though optical character recognition technology has helped many blind people to ‘read’ the world, there is not a single device that allows them to fill out a paper-based form without a human assistant. The task of filling forms is however an essential part of their daily lives, for example, for access to social security or benefits. This paper describes a solution that allows a blind person to complete paper-based forms, pervasively and independently, using only off-the-shelf equipment including a Smartphone, a clipboard with sliding ruler, and a ballpoint pen. A dynamic color fiduciary (point of reference) marker is designed so that it can be moved by the user to any part of the form such that all regions can be “visited”. This dynamic color fiduciary marker is robust to camera focus and partial occlusion, allowing flexibility in handling the Smartphone with embedded camera. Feedback is given to the blind user via both voice and tone to facilitate efficient guidance in filling out the form. Experimental results have shown that this prototype can help visually impaired people to fill out a form independently.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visually impaired people show superior abilities in various perception tasks such as auditory attention, auditory temporal resolution, auditory spatial tuning, and odor discrimination. However, with the use of psychophysical methods, auditory and olfactory detection thresholds typically do not differ between visually impaired and sighted participants. Using a motion platform we investigated thresholds of passive whole-body motion discrimination in nine visually impaired participants and nine age-matched sighted controls. Participants were rotated in yaw, tilted in roll, and translated along the y-axis at two different frequencies (0.3 Hz and 2 Hz). An adaptive 3-down 1-up staircase procedure was used along with a two-alternative direction (leftward vs. rightward) discrimination task. Superior performance of visually impaired participants was found in the 0.3 Hz roll tilt condition. No differences between the visually impaired and controls were observed in all other types of motion. The superior performance in the 0.3 Hz roll tilt condition could reflect differences in the integration of extra-vestibular cues and increased sensitivity towards changes in the direction of the gravito-inertial force. In the absence of visual information, roll tilts entail a more pronounced risk of falling, and this could eventually account for the group difference. It is argued that differences in experimental procedures (i.e. detection vs. discrimination of stimuli) explain the discrepant findings across perceptual tasks comparing blind and sighted participants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite the close interrelation between vestibular and visual processing (e.g., vestibulo-ocular reflex), surprisingly little is known about vestibular function in visually impaired people. In this study, we investigated thresholds of passive whole-body motion discrimination (leftward vs. rightward) in nine visually impaired participants and nine age-matched sighted controls. Participants were rotated in yaw, tilted in roll, and translated along the interaural axis at two different frequencies (0.33 and 2 Hz) by means of a motion platform. Superior performance of visually impaired participants was found in the 0.33 Hz roll tilt condition. No differences were observed in the other motion conditions. Roll tilts stimulate the semicircular canals and otoliths simultaneously. The results could thus reflect a specific improvement in canal–otolith integration in the visually impaired and are consistent with the compensatory hypothesis, which implies that the visually impaired are able to compensate the absence of visual input.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.