Resumo:
Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.
Resumo:
El objetivo del estudio es evaluar el remodelado estructural y funcional de las arterias pulmonares asociado a insuficiencia respiratoria crónica severa, mediante ecografía intravascular (IVUS). Se incluyeron 80 pacientes en estudio pretrasplante pulmonar a los que se les realizó cateterismo cardiaco derecho e IVUS de una arteria pulmonar de mediano calibre. A través del IVUS se determinó el módulo elástico, pulsatilidad y porcentaje de fibrosis arterial. La insuficiencia respiratoria crónica se asoció a una vasculopatía arterial pulmonar severa, independientemente de la presencia de hipertensión pulmonar. Los pacientes con EPOC (enfermedad pulmonar obstructiva crónica) presentaban un mayor grado de fibrosis arterial, mientras que los pacientes con EPID (enfermedad pulmonar intersticial difusa) presentaban mayor rigidez arterial.
Resumo:
This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated. We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be solved.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
Intravascular ultrasound (IVUS) phantoms are important to calibrate and evaluate many IVUS imaging processing tasks. However, phantom generation is never the primary focus of related works; hence, it cannot be well covered, and is usually based on more than one platform, which may not be accessible to investigators. Therefore, we present a framework for creating representative IVUS phantoms, for different intraluminal pressures, based on the finite element method and Field II. First, a coronary cross-section model is selected. Second, the coronary regions are identified to apply the properties. Third, the corresponding mesh is generated. Fourth, the intraluminal force is applied and the deformation computed. Finally, the speckle noise is incorporated. The framework was tested taking into account IVUS contrast, noise and strains. The outcomes are in line with related studies and expected values. Moreover, the framework toolbox is freely accessible and fully implemented in a single platform. (E-mail: fernando.okara@gmail.com) (c) 2012 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Mode of access: Internet.
Resumo:
Intravascular ultrasound (IVUS) image segmentation can provide more detailed vessel and plaque information, resulting in better diagnostics, evaluation and therapy planning. A novel automatic segmentation proposal is described herein; the method relies on a binary morphological object reconstruction to segment the coronary wall in IVUS images. First, a preprocessing followed by a feature extraction block are performed, allowing for the desired information to be extracted. Afterward, binary versions of the desired objects are reconstructed, and their contours are extracted to segment the image. The effectiveness is demonstrated by segmenting 1300 images, in which the outcomes had a strong correlation to their corresponding gold standard. Moreover, the results were also corroborated statistically by having as high as 92.72% and 91.9% of true positive area fraction for the lumen and media adventitia border, respectively. In addition, this approach can be adapted easily and applied to other related modalities, such as intravascular optical coherence tomography and intravascular magnetic resonance imaging. (E-mail: matheuscardosomg@hotmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Aims: We aimed to evaluate if the co-localisation of calcium and necrosis in intravascular ultrasound virtual histology (IVUS-VH) is due to artefact, and whether this effect can be mathematically estimated. Methods and results: We hypothesised that, in case calcium induces an artefactual coding of necrosis, any addition in calcium content would generate an artificial increment in the necrotic tissue. Stent struts were used to simulate the ""added calcium"". The change in the amount and in the spatial localisation of necrotic tissue was evaluated before and after stenting (n=17 coronary lesions) by means of a especially developed imaging software. The area of ""calcium"" increased from a median of 0.04 mm(2) at baseline to 0.76 mm(2) after stenting (p<0.01). In parallel the median necrotic content increased from 0.19 mm(2) to 0.59 mm(2) (p<0.01). The ""added"" calcium strongly predicted a proportional increase in necrosis-coded tissue in the areas surrounding the calcium-like spots (model R(2)=0.70; p<0.001). Conclusions: Artificial addition of calcium-like elements to the atherosclerotic plaque led to an increase in necrotic tissue in virtual histology that is probably artefactual. The overestimation of necrotic tissue by calcium strictly followed a linear pattern, indicating that it may be amenable to mathematical correction.
Resumo:
Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica. A presente dissertação foi desenvolvida no Erasmus Medical Center em Roterdão, Holanda
Resumo:
AbstractIntroduction:Cardiac allograft vasculopathy (CAV) is a major limitation for long-term survival of patients undergoing heart transplantation (HT). Some immunosuppressants can reduce the risk of CAV.Objectives:The primary objective was to evaluate the variation in the volumetric growth of the intimal layer measured by intracoronary ultrasound (IVUS) after 1 year in patients who received basiliximab compared with that in a control group.Methods:Thirteen patients treated at a single center between 2007 and 2009 were analyzed retrospectively. Evaluations were performed with IVUS, measuring the volume of a coronary segment within the first 30 days and 1 year after HT. Vasculopathy was characterized by the volume of the intima of the vessel.Results:Thirteen patients included (7 in the basiliximab group and 6 in the control group). On IVUS assessment, the control group was found to have greater vessel volume (120–185.43 mm3 vs. 127.77–131.32 mm3; p = 0.051). Intimal layer growth (i.e., CAV) was also higher in the control group (27.30–49.15 mm3 [∆80%] vs. 20.23–26.69 mm3[∆33%]; p = 0.015). Univariate regression analysis revealed that plaque volume and prior atherosclerosis of the donor were not related to intima growth (r = 0.15, p = 0.96), whereas positive remodeling was directly proportional to the volumetric growth of the intima (r = 0.85, p < 0.001).Conclusion:Routine induction therapy with basiliximab was associated with reduced growth of the intima of the vessel during the first year after HT.
Resumo:
Background:Vascular remodeling, the dynamic dimensional change in face of stress, can assume different directions as well as magnitudes in atherosclerotic disease. Classical measurements rely on reference to segments at a distance, risking inappropriate comparison between dislike vessel portions.Objective:to explore a new method for quantifying vessel remodeling, based on the comparison between a given target segment and its inferred normal dimensions.Methods:Geometric parameters and plaque composition were determined in 67 patients using three-vessel intravascular ultrasound with virtual histology (IVUS-VH). Coronary vessel remodeling at cross-section (n = 27.639) and lesion (n = 618) levels was assessed using classical metrics and a novel analytic algorithm based on the fractional vessel remodeling index (FVRI), which quantifies the total change in arterial wall dimensions related to the estimated normal dimension of the vessel. A prediction model was built to estimate the normal dimension of the vessel for calculation of FVRI.Results:According to the new algorithm, “Ectatic” remodeling pattern was least common, “Complete compensatory” remodeling was present in approximately half of the instances, and “Negative” and “Incomplete compensatory” remodeling types were detected in the remaining. Compared to a traditional diagnostic scheme, FVRI-based classification seemed to better discriminate plaque composition by IVUS-VH.Conclusion:Quantitative assessment of coronary remodeling using target segment dimensions offers a promising approach to evaluate the vessel response to plaque growth/regression.
Resumo:
Purpose: The purpose of this study was to compare the plaque morphology between coronary and peripheral arteries using intravascular ultrasound (IVUS). Methods: IVUS was performed in 68 patients with coronary and 93 with peripheral artery lesions (29 carotid, 50 renal, and 14 iliac). Plaques were classified as fibroatheroma (VH-FA) (further subclassified as thin-capped [VH-TCFA] and thick-capped [VH-ThCFA]), fibrocalcific plaque (VH-FC) and pathological intimal thickening (VH-PIT). Results: Plaque rupture (13% of coronary, 7% of carotid, 6% of renal, and 7% of iliac arteries; P=NS) and VH-TCFA (37% of coronary, 24% of carotid, 16% of renal, and 7% of iliac arteries; P=0.02) was observed in all arteries. Compared to coronary arteries, VH-FA was less frequently observed in renal (P<0.001) and iliac arteries (P<0.006), while VH-PIT and VH-FC were prevalent in both of these peripheral arteries. Lesions with positive remodeling demonstrated more characteristics of VH-FA in coronary, carotid, and renal arteries compared to those with intermediate/negative remodeling (all P<0.01). There was positive relationship between RI and percent necrotic core area in all four arteries. Conclusions: Atherosclerotic plaque phenotypes were heterogeneous among four different arteries. In contrast, the associations of remodeling mode with plaque phenotype and composition were similar among the various arterial beds.
Resumo:
OBJECTIVE: : Intravascular ultrasound (IVUS) generates high definition circumferential cross-sectional images and provides real-time readout of vascular dimensions, including visualization of vessel branches. We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up. METHODS: : Out of consecutive 203 patients with descending thoracic aortic aneurysm, 89 (43.8%) received endovascular treatment [mean age, 68 ± 8 years; range, 29-82; male, 79 (88.7%); female, 10 (11.3%)] without using angiography during the endovascular procedure. IVUS (6 F, 12.5 MHz probe or 10 F 9 MHz) coupled with fluoroscopy for the placement of radiopaque markers was used for target site identification, landing zone measurement, device positioning, and assessment of endovascular repair. RESULTS: : Hospital mortality was 4/89 (4.5%). Number of devices implanted in each patient was 1.2 (range, 1-3). X-ray exposure time was 12 ± 8 minutes. Median procedure time was 63 ± 20 minutes. Conversion to open surgery was necessary in one patient (1.1%) because of aortic dissection. In nine patients (10.1%) left subclavian artery was covered because of a short neck. Two patients (2.2%) had vascular access lesions and required surgical repair. One patient developed paraplegia (1.1%). Early endoleak was observed in eight patients (8.9%) and 4 (4.5%) required additional procedures (proximal or distal extensions). Late conversion was necessary in one patient (1.1%). CONCLUSIONS: : IVUS provides all information necessary for device selection, target site identification as well as safe and correct deployment of thoracic endoprostheses and makes periprocedural angiography unnecessary, thus avoiding the risk of renal failure because of contrast medium.