872 resultados para INTERNAL CONTAMINATION
Resumo:
To evaluate the checkerboard DNA-DNA hybridization method for detection and quantitation of bacteria from the internal parts of dental implants and to compare bacterial leakage from implants connected either to cast or to pre-machined abutments. Nine plastic abutments cast in a Ni-Cr alloy and nine pre-machined Co-Cr alloy abutments with plastic sleeves cast in Ni-Cr were connected to Branemark-compatible implants. A group of nine implants was used as control. The implants were inoculated with 3 mu l of a solution containing 10(8) cells/ml of Streptococcus sobrinus. Bacterial samples were immediately collected from the control implants while assemblies were completely immersed in 5 ml of sterile Tripty Soy Broth (TSB) medium. After 14 days of anaerobic incubation, occurrence of leakage at the implant-abutment interface was evaluated by assessing contamination of the TSB medium. Internal contamination of the implants was evaluated with the checkerboard DNA-DNA hybridization method. DNA-DNA hybridization was sensitive enough to detect and quantify the microorganism from the internal parts of the implants. No differences in leakage and in internal contamination were found between cast and pre-machined abutments. Bacterial scores in the control group were significantly higher than in the other groups (P < 0.05). Bacterial leakage through the implant-abutment interface does not significantly differ when cast or pre-machined abutments are used. The checkerboard DNA-DNA hybridization technique is suitable for the evaluation of the internal contamination of dental implants although further studies are necessary to validate the use of computational methods for the improvement of the test accuracy. To cite this article:do Nascimento C, Barbosa RES, Issa JPM, Watanabe E, Ito IY, Albuquerque Junior RF. Use of checkerboard DNA-DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments.Clin. Oral Impl. Res. 20, 2009; 571-577.doi: 10.1111/j.1600-0501.2008.01663.x.
Resumo:
The aim of this in vitro study was to evaluate bacterial leakage along the implant-abutment interface under unloaded conditions. Twelve premachined abutments with plastic sleeves and 12 dental implants were used in this study. Prior to tests of bacterial leakage, samples from the inner parts of the implants were collected with sterile microbrushes to serve as negative controls for contamination. After casting, the abutments were tightened to 32 Ncm on the implants. The assemblies were immersed in 2.0 mL of human saliva and incubated for 7 days. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all the implants evaluated. Aggregatibacter actinomycetemcomitans and Capnocytophaga gingivalis were the most incident species. No microorganisms were found in the samples recovered from the implants before contamination testing (negative control). Bacterial species from human saliva may penetrate the implant-abutment interface under unloaded conditions. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:782-787
Resumo:
Olkiluodon ja Loviisan ydinvoimalaitoksilla syntyvä käytetty ydinpolttoaine tullaan kapseloimaan ja loppusijoittamaan Posiva Oy:n kapselointi- ja loppusijoituslaitoksella, joka rakennetaan Olkiluotoon. Käytetyn polttoaineen käsittelyssä on huomioitava säteilytyöhön liittyviä säteilysuojelunäkökohtia. Kapseloinnissa ja loppusijoituksessa käsitellään vaarallisia säteilylähteitä, joista merkittävimmät ovat käytetty ydinpolttoaine ja täyden loppusijoituskapselin röntgentarkastuslaitteisto. Posivan laitosten käyttötoiminnalle muodostetaan tässä diplomityössä säteilysuojelun vaatimusmäärittely. Kapseloinnin ja loppusijoituksen säteilytyövaiheet käsitellään yksitellen säteilysuojelun näkökulmasta. Työvaiheille määritetään tarpeelliset säteilysuojelutoimenpiteet ja työvaiheiden suorittamisen säteilysuojeluvaatimukset. Molempien laitosten valvonta-aluejärjestelyjä ja säteilyolosuhteiden vyöhykejakoa tarkennetaan. Työssä määritetään vyöhyke- ja aluerajoilla vaadittavat säteilysuojelutoiminnot sekä kontaminaationhallinnan laatuvaatimukset. Työssä käsitellään myös operatiivisen säteilysuojelun toimenpiteiden laatuvaatimuksia ja tarvittavaa säteilysuojelun sisäistä ohjeistoa. Työn tuloksena on kapselointi- ja loppusijoituslaitoksen käyttötoiminnan operatiivisten säteilysuojelutoimenpiteiden kuvaus. Kapselointi- ja loppusijoituslaitosten säteilysuojelua toteutetaan käyttövaiheen työnsuunnittelulla, operatiivisilla säteilysuojelutoimilla ja rakenteellisin keinoin. Työntekijöiden säteilyannokset minimoidaan välttämällä oleskelua kohonneen säteilytason alueilla. Kapselin röntgentarkastuslaitteiston käytön säteilyturvallisuus on varmistettava ja laitosten käyttötoiminta ei saa aiheuttaa työntekijöille sisäistä säteilyannosta. Useista työvaiheista ja käyttötoiminnan poikkeustilanteista on tehtävä jatkoanalyyseja työntekijöiden säteilysuojelun näkökulmasta.
Resumo:
Purpose: Bacterial leakage along the implant-abutment interface, with consequent species harboring the inner parts of two-part dental implant systems, has been reported in the literature. The aim of this in vitro study was to evaluate bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loaded and unloaded conditions using DNA Checkerboard. Materials and Methods: Sixty denial implants-20 each of external-hexagon, internal-hexagon, and Morse cone-connection designs-and their conical abutments were used in this study. Each group was subdivided into two groups of 10 loaded and 10 unloaded implants. The assemblies were immersed in human saliva and either (1) loaded with 500,000 cycles at 120 N (experimental group) or (2) incubated in static conditions for 7 days at 35 degrees C (unloaded control group). Results: Microorganisms were found in the internal surfaces of all types of connections. The Morse cone connection presented the lowest count of microorganisms in both the unloaded and loaded groups. Loaded implants presented with higher counts of microorganisms than unloaded implants for external- and internal-hex connections. Conclusion: Bacterial species from human saliva may penetrate along the implant-abutment interface under both unloaded and loaded conditions for all connections evaluated. Morse cone-connection implants showed the lowest counts of microorganisms for both conditions. External- and internal-hex implants showed a higher incidence of bacteria and higher bacterial counts after simulated loading. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:551-560.
Resumo:
Objective Bacterial species have been found harboring the internal surface of dental implants as consequence of their failed connections. The aim of the present study was to compare the detection frequency of bacterial leakage from human saliva through the implantabutment interface, under non-loading conditions, using either DNA Checkerboard or culture method. Materials and methods Thirty dental implants with hexagonal platforms were connected to pre-machined abutments according to the manufacturers specifications. The assemblies were individually incubated in human saliva under anaerobic conditions for 7 similar to days at 37 degrees C. Afterward, contents from the inner parts of the implants were collected and evaluated with either DNA Checkerboard (s similar to=similar to 15) or culture (n similar to=similar to 15). Subsequently, identification and quantitation of bacterial species from saliva and implants were carried out for the group evaluated with the DNA Checkerboard method. Results Both DNA Checkerboard and culture showed positive signals of bacterial leakage in 6 of the 15 evaluated samples. Capnocytophaga gingivalis and Streptococcus mutans were the most frequently detected species harboring the internal surface of the implants followed by Veillonella parvula. Conclusion Occurrence of bacterial leakage along the implantabutment interface is comparably detected with both DNA Checkerboard hybridization and conventional culture methods.
Resumo:
Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 degrees C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p < 0.001). No differences were found between groups 1 and 2 (p > 0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.
Resumo:
Os tratamentos odontológicos com implantes dentários, têm sido bem documentados nos últimos 40 anos e com grandes sucessos. O implante dentário instalado no local de dentes perdidos deve envolver sempre um correto planejamento pelo médico dentista. Nesta área é muito importante o conhecimento do microbioma que envolve o implante dentário, desde seu planejamento até a reabilitação final. O tempo exato com que o microbioma se forma, assim como, os microrganismos presentes são fundamentais para a correta execução e êxito do implante. Contudo a contaminação interna dos implantes reabilitados, os componentes extracelulares de microrganismos, como as endotoxinas, têm uma enorme influência no sucesso dos implantes. Além disso, o conhecimento das superfícies dos implantes e a relação com a presença microbiana também muito importante. O presente estudo realizou uma revisão bibliográfica sobre o microbioma oral e sua relação com a infecção periimplantar, discutindo diversos estudos, tanto clássicos como atuais. Embora se possa concluir que o microbioma periimplantar é caracterizado pelo microbioma anterior à instalação dos implantes dentários, podemos referir a necessidade de mais estudos de modo a elucidar melhor o planejamento e a longevidade dos tratamentos com implantes dentários.
Resumo:
Purpose: This study tested the null hypothesis that different treatments of saliva-contaminated substrate would not affect microgap formation at the dentin walls of bonded restorations. Materials and Methods: Forty freshly extracted human molars received standardized Class V preparations on buccal and lingual surfaces. The specimens were assigned to four experimental groups (n = 20): [G1] no contamination (control group), [G2] saliva contamination (10 s) after etching followed by 5 s air stream; [G3] saliva contamination after etching and rinsed for 10 s; and [G4] re-etching for 10 s after saliva contamination. All specimens were restored with a one-bottle adhesive (Single Bond, 3M ESPE) and microhybrid composite resin (Filtek Z250, 3M ESPE) according to the manufacturer's instructions. The specimens were thermocycled, sectioned through the center of the restoration, and then processed for SEM. Microgaps were measured at the axial wall at 1500X magnification. The data were submitted to Kruskal-Wallis nonparametric statistical analysis at p < 0.05. Results: The data revealed that different groups resulted in a statistically significant difference (p < 0.01) in gap formation. Air drying [G2] and rinsing [G3] the saliva-contaminated dentin resulted in similar microgap values (p > 0.05). However, re-etching the dentin after saliva contamination [G4] increased microgap formation (p < 0.05) when compared with the groups G1 and G2. Although air drying and rinsing produced results comparable to noncontaminated dentin, the presence of microgaps was not completely eliminated. Conclusion: Contaminated saliva did not prevent hybrid layer formation; however, it did reduce the adaptation of the restorative material to bonded surfaces.
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.
Resumo:
Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half-lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. (123)I, (124)I, (125)I and (131)I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as (99m)Tc and those used in positron emission tomography imaging, i.e. (11)C, (15)O, (18)F and (68)Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. (67)Ga, (111)In and (201)Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. (90)Y and (169)Er, as well as beta emitters with low-intensity gamma rays, i.e. (153)Sm, (177)Lu, (186)Re and (188)Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic considerations.
Resumo:
OBJECTIVETo search for evidence of the efficiency of sodium hypochlorite on environmental surfaces in reducing contamination and prevention of healthcare-associated infection HAIs.METHODSystematic review in accordance with the Cochrane Collaboration.RESULTSWe analyzed 14 studies, all controlled trials, published between 1989-2013. Most studies resulted in inhibition of microorganism growth. Some decreased infection, microorganism resistance and colonization, loss of efficiency in the presence of dirty and surface-dried viruses.CONCLUSIONThe hypochlorite is an effective disinfectant, however, the issue of the direct relation with the reduction of HAIs remains. The absence of control for confounding variables in the analyzed studies made the meta-analysis performance inadequate. The evaluation of internal validity using CONSORT and TREND was not possible because its contents were not appropriate to laboratory and microbiological studies. As a result, there is an urgent need for developing specific protocol for evaluating such studies.
Resumo:
Introduction : Chez les nouveau-nés prématurés, l’hyper-alimentation intraveineuse (HAIV) contribue à leur survie, mais elle est aussi une source importante de molécules oxydantes. L’absence d’une protection adéquate contre la lumière ambiante génère in vitro, via la photo-excitation de la riboflavine, du H2O2, des peroxydes organiques et un dérivé peroxydé de la vitamine C, l’ascorbylperoxyde (AscOOH). Plusieurs données du laboratoire associent l’infusion d’HAIV à des désordres lipidiques dans notre modèle animal. L’hypothèse est donc que l’AscOOH a un pouvoir oxydant et est responsable de certains des effets biologiques observés. Mes objectifs sont les suivants : 1) développer une méthode de dosage de l’AscOOH; 2) démontrer, à l’aide du modèle animal bien établi au laboratoire, des relations entre la concentration tissulaire de cette molécule et des paramètres métaboliques et l’état redox au foie et dans la circulation; et 3) confirmer l’effet physiologique de l’AscOOH dans un modèle cellulaire. Méthode : Différents étalons internes potentiels ont été testés pour le dosage de l’AscOOH par spectrométrie de masse après séparation sur HPLC (LC-MS). Les phases mobiles et conditions chromatographiques ont été optimisées. Pour l’objectif 2, des cobayes de 3 jours de vie (n=11) ont reçu par voie intraveineuse une dose d’AscOOH (entre 0 et 3,3mM). Les animaux ont été sacrifiés au 4e jour de traitement pour le prélèvement de tissus. Les concentrations tissulaires d’AscOOH ont été déterminées au LC-MS. La triglycéridémie et la cholestérolémie ont été mesurées à l’aide d’un kit commercial par spectrophotométrie. Le glutathion oxydé et réduit ont été mesurés par électrophorèse capillaire. Les relations linéaires obtenues sont exprimées par le ratio des carrés (r2), et traitées par ANOVA. Résultats : La validation du dosage de l’AscOOH par LC-MS a été réalisée. Chez les animaux, la concentration urinaire d’AscOOH par créatinine corrèle positivement avec la dose reçue, négativement avec la lipidémie, et négativement avec le redox sanguin et érythrocytaire, indiquant un milieu moins oxydé. Conclusion : La concentration urinaire d’AscOOH peut donc être un reflet de l’oxydation de l’HAIV en clinique. Nos données chez l’animal suggèrent une interaction de l’AscOOH avec le métabolisme hépatique produisant une chute de la concentration plasmatique de cholestérol et de triglycérides. Le modèle cellulaire n’a pas permis d’élucider le mécanisme moléculaire de l’action de l’AscOOH sur le métabolisme.
Resumo:
The Early Paleozoic geodynamic evolution in SW Iberia is believed to have been dominated by the opening of the Rheic Ocean. The Rheic Ocean is generally accepted to have resulted from the drift of peri-Gondwanan terranes such as Avalonia from the northern margin of Gondwana during Late Cambrian-Early Ordovician times. The closure of the Rheic Ocean was the final result of a continent-continent collision between Gondwana and Laurussia that produced the Variscan orogen. The Ossa-Morena Zone is a peri-Gondwana terrane, which preserves spread fragments of ophiolites - the Internal Ossa-Morena Zones Ophiolite Sequences (IOMZOS). The final patchwork of the IOMZOS shows a complete oceanic lithospheric sequence with geochemical characteristics similar to the ocean-floor basalts, without any orogenic fingerprint and/or crustal contamination. The IOMZOS were obducted and imbricated with high pressure lithologies. Based on structural, petrological and whole-rock geochemical data, the authors argue that the IOMZOS represent fragments of the oceanic lithosphere from the Rheic Ocean. Zircon SHRIMP U-Pb geochronological data on metagabbros point to an age of ca. 480 Ma for IOMZOS, providing evidence of a well-developed ocean in SW Iberia during this period, reinforcing the interpretation of the Rheic Ocean as a wide ocean among the peri-Gondwanan terranes during Early Ordovician times.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)