970 resultados para INK
Resumo:
To evaluate p16(INK) (4a) immunoexpression in CIN1 lesions looking for differences between cases that progress to CIN2/3 maintain CIN1 diagnosis, or spontaneously regress. Seventy-four CIN1 biopsies were studied. In the follow-up, a second biopsy was performed and 28.7% showed no lesion (regression), 37.9% maintained CIN1, and 33.4% progressed to CIN2/3. Immunostaining for p16(INK) (4a) was performed in the first biopsy and it was considered positive when there was strong and diffuse staining of the basal and parabasal layers. Pearson's chi-square was used to compare the groups (p ≤ 0.05). The age of the patients was similar. There was no significant difference in p16(INK) (4a) immunoexpression in the groups, however, statistical analyses showed a significant association when only the progression and regression groups were compared (p = 0.042). Considering p16(INK) (4a) positivity and the progression to CIN2/3, the sensitivity, specificity, positive, and negative predictive values in our cohort were 45%, 75%, 47%, and 94%, respectively. We emphasize that CIN1 with p16(INK) (4a) staining was associated with lesion progression, but the sensitivity was not high. However, the negative predictive value was more reliable (94%) and p16(INK) (4a) may represent a useful biomarker that can identify CIN1 lesions that need particular attention, complementing morphology.
Resumo:
The pore-opening size of MCM-41 is tailored to be in the microporous region using a chemical vapor deposition technique for selective tailoring. Although the pore opening is narrowed, the internal pore body of MCM-41 remains unchanged so the pore volume retains a substantial portion (80%) of its original value. The adsorption equilibrium of nitrogen and benzene in the modified MCM-41 shows a type I isotherm, which significantly improves the adsorption performance of MCM-41 for low-concentration volatile organic compounds. The adsorption kinetics of benzene in the modified MCM-41 is also studied.
Resumo:
Lithium-ion battery cathodes have been fabricated by screen-printing through the development of CLiFePO4 inks. It is shown that shear thinning polymer solutions in N-methyl-2-pyrrolidone (NMP) with Newtonian viscosity above 0.4 Pa s are the best binders for formulating a cathode paste with satisfactory film forming properties. The paste shows an elasticity of the order of 500 Pa and, after shear yielding, shows an apparent viscosity of the order of 3 Pa s for shear rates corresponding to those used during screen-printing. The screen-printed cathode produced with a thickness of 26 mm shows a homogeneous distribution of the active material, conductive additive and polymer binder. The total resistance and diffusion coefficient of the cathode are 450 V and 2.5 10 16cm2 s 1, respectively. The developed cathodes show an initial discharge capacity of 48.2 mAh g 1 at 5C and a discharge value of 39.8 mAh g 1 after 50 cycles. The capacity retention of 83% represents 23% of the theoretical value (charge and/or discharge process in twenty minutes), demonstrating the good performance of the battery. Thus, the developed C-LiFePO4 based inks allow to fabricate screen-printed cathodes suitable for printed lithium-ion batteries
Resumo:
The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.
Resumo:
Forensic examinations of ink have been performed since the beginning of the 20th century. Since the 1960s, the International Ink Library, maintained by the United States Secret Service, has supported those analyses. Until 2009, the search and identification of inks were essentially performed manually. This paper describes the results of a project designed to improve ink samples' analytical and search processes. The project focused on the development of improved standardization procedures to ensure the best possible reproducibility between analyses run on different HPTLC plates. The successful implementation of this new calibration method enabled the development of mathematical algorithms and of a software package to complement the existing ink library.
Resumo:
Resume : L'utilisation de l'encre comme indice en sciences forensiques est décrite et encadrée par une littérature abondante, comprenant entre autres deux standards de l'American Society for Testing and Materials (ASTM). La grande majorité de cette littérature se préoccupe de l'analyse des caractéristiques physiques ou chimiques des encres. Les standards ASTM proposent quelques principes de base qui concernent la comparaison et l'interprétation de la valeur d'indice des encres en sciences forensiques. L'étude de cette littérature et plus particulièrement des standards ASTM, en ayant a l'esprit les développements intervenus dans le domaine de l'interprétation de l'indice forensique, montre qu'il existe un potentiel certain pour l'amélioration de l'utilisation de l'indice encre et de son impact dans l'enquête criminelle. Cette thèse propose d'interpréter l'indice encre en se basant sur le cadre défini par le théorème de Bayes. Cette proposition a nécessité le développement d'un système d'assurance qualité pour l'analyse et la comparaison d'échantillons d'encre. Ce système d'assurance qualité tire parti d'un cadre théorique nouvellement défini. La méthodologie qui est proposée dans ce travail a été testée de manière compréhensive, en tirant parti d'un set de données spécialement créer pour l'occasion et d'outils importés de la biométrie. Cette recherche répond de manière convaincante à un problème concret généralement rencontré en sciences forensiques. L'information fournie par le criminaliste, lors de l'examen de traces, est souvent bridée, car celui-ci essaie de répondre à la mauvaise question. L'utilisation d'un cadre théorique explicite qui définit et formalise le goal de l'examen criminaliste, permet de déterminer les besoins technologiques et en matière de données. Le développement de cette technologie et la collection des données pertinentes peut être justifiées économiquement et achevée de manière scientifique. Abstract : The contribution of ink evidence to forensic science is described and supported by an abundant literature and by two standards from the American Society for Testing and Materials (ASTM). The vast majority of the available literature is concerned with the physical and chemical analysis of ink evidence. The relevant ASTM standards mention some principles regarding the comparison of pairs of ink samples and the evaluation of their evidential value. The review of this literature and, more specifically, of the ASTM standards in the light of recent developments in the interpretation of forensic evidence has shown some potential improvements, which would maximise the benefits of the use of ink evidence in forensic science. This thesis proposes to interpret ink evidence using the widely accepted and recommended Bayesian theorem. This proposition has required the development of a new quality assurance process for the analysis and comparison of ink samples, as well as of the definition of a theoretical framework for ink evidence. The proposed technology has been extensively tested using a large dataset of ink samples and state of the art tools, commonly used in biometry. Overall, this research successfully answers to a concrete problem generally encountered in forensic science, where scientists tend to self-limit the usefulness of the information that is present in various types of evidence, by trying to answer to the wrong questions. The declaration of an explicit framework, which defines and formalises their goals and expected contributions to the criminal and civil justice system, enables the determination of their needs in terms of technology and data. The development of this technology and the collection of the data is then justified economically, structured scientifically and can be proceeded efficiently.
Resumo:
Laser desorption ionisation mass spectrometry (LDI-MS) has demonstrated to be an excellent analytical method for the forensic analysis of inks on a questioned document. The ink can be analysed directly on its substrate (paper) and hence offers a fast method of analysis as sample preparation is kept to a minimum and more importantly, damage to the document is minimised. LDI-MS has also previously been reported to provide a high power of discrimination in the statistical comparison of ink samples and has the potential to be introduced as part of routine ink analysis. This paper looks into the methodology further and evaluates statistically the reproducibility and the influence of paper on black gel pen ink LDI-MS spectra; by comparing spectra of three different black gel pen inks on three different paper substrates. Although generally minimal, the influences of sample homogeneity and paper type were found to be sample dependent. This should be taken into account to avoid the risk of false differentiation of black gel pen ink samples. Other statistical approaches such as principal component analysis (PCA) proved to be a good alternative to correlation coefficients for the comparison of whole mass spectra.
Resumo:
In the first part of this research, three stages were stated for a program to increase the information extracted from ink evidence and maximise its usefulness to the criminal and civil justice system. These stages are (a) develop a standard methodology for analysing ink samples by high-performance thin layer chromatography (HPTLC) in reproducible way, when ink samples are analysed at different time, locations and by different examiners; (b) compare automatically and objectively ink samples; and (c) define and evaluate theoretical framework for the use of ink evidence in forensic context. This report focuses on the second of the three stages. Using the calibration and acquisition process described in the previous report, mathematical algorithms are proposed to automatically and objectively compare ink samples. The performances of these algorithms are systematically studied for various chemical and forensic conditions using standard performance tests commonly used in biometrics studies. The results show that different algorithms are best suited for different tasks. Finally, this report demonstrates how modern analytical and computer technology can be used in the field of ink examination and how tools developed and successfully applied in other fields of forensic science can help maximising its impact within the field of questioned documents.
Resumo:
The ASTM standards on Writing Ink Identification (ASTM 1789-04) and on Writing Ink Comparison (ASTM 1422-05) are the most up-to-date guidelines that have been published on the forensic analysis of ink. The aim of these documents is to cover most aspects of the forensic analysis of ink evidence, from the analysis of ink samples, the comparison of the analytical profile of these samples (with the aim to differentiate them or not), through to the interpretation of the result of the examination of these samples in a forensic context. Significant evolutions in the technology available to forensic scientists, in the quality assurance requirements brought onto them, and in the understanding of frameworks to interpret forensic evidence have been made in recent years. This article reviews the two standards in the light of these evolutions and proposes some practical improvements in terms of the standardization of the analyses, the comparison of ink samples, and the interpretation of ink examination. Some of these suggestions have already been included in a DHS funded project aimed at creating a digital ink library for the United States Secret Service.
Resumo:
Several ink dating methods based on solvents analysis using gas chromatography/mass spectrometry (GC/MS) were proposed in the last decades. These methods follow the drying of solvents from ballpoint pen inks on paper and seem very promising. However, several questions arose over the last few years among questioned documents examiners regarding the transparency and reproducibility of the proposed techniques. These questions should be carefully studied for accurate and ethical application of this methodology in casework. Inspired by a real investigation involving ink dating, the present paper discusses this particular issue throughout four main topics: aging processes, dating methods, validation procedures and data interpretation. This work presents a wide picture of the ink dating field, warns about potential shortcomings and also proposes some solutions to avoid reporting errors in court.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science- Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.