986 resultados para IN-VITRO DEGRADATION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indospicine toxicosis was reported in sheep, goats and cattle fed on Indigofera, a leguminous plant rich in indospicine. Recent death report on dogs as a result of dietary ingestion of indospicine contaminated camel meat has raised concern about the distribution of this toxin in camels fed on Indigofera. This in vitro study aimed at measuring the degradability of indospicine in Indigofera spicata by camel-foregut fluid and attempted at explaining indospicine accumulation in meat tissue. In the first experiment, in vitro dry matter digestibility and indospicine disappearance were evaluated by using foregut fluid from 15 feral camels. Foregut fluid was collected post mortem from a nearby abattoir. In the second experiment, a composite foregut fluid obtained from three feral camels was used to examine the time-dependent degradation of indospicine. Results indicated that 99 of the dietary indospicine was degraded after 48 h of incubation. The time-dependent degradation study showed rapid degradation (11 µg/h) during the first 18 h of incubation, followed by a much slower rate (2 µg/h) between 18-48 h. Results demonstrated the ability of the camel microbiota to degrade indospicine and suggest the presence of a by-pass mechanism that enables the toxin to escape degradation and reaches the intestine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Strontium ions (Sr2+) are known to prevent osteoporosis and also encourage bone formation. Such twin requirements have motivated researchers to develop Sr-substituted biomaterials for orthopaedic applications. The present study demonstrates a new concept of developing Sr-substituted Mg-3(PO4)(2) - based biodegradable scaffolds. In particular, this work reports the fabrication, mechanical properties with an emphasis on strength reliability as well as in vitro degradation of highly biodegradable strontium-incorporated magnesium phosphate cements. These implantable scaffolds were fabricated using three-dimensional powder printing, followed by high temperature sintering and/or chemical conversion, a technique adaptable to develop patient-specific implants. A moderate combination of strength properties of 36.7 MPa (compression), 242 MPa (bending) and 10.7 MPa (tension) were measured. A reasonably modest Weibull modulus of up to 8.8 was recorded after uniaxial compression or diametral tensile tests on 3D printed scaffolds. A comparison among scaffolds with varying compositions or among sintered or chemically hardened scaffolds reveals that the strength reliability is not compromised in Sr-substituted scaffolds compared to baseline Mg-3(PO4)(2). The micro-computed tomography analysis reveals the presence of highly interconnected porous architecture in three-dimension with lognormal pore size distribution having median in the range of 17.74-26.29 mu m for the investigated scaffolds. The results of extensive in vitro ion release study revealed passive degradation with a reduced Mg2+ release and slow but sustained release of Sr2+ from strontium-substituted magnesium phosphate scaffolds. Taken together, the present study unequivocally illustrates that the newly designed Sr-substituted magnesium phosphate scaffolds with good strength reliability could be used for biomedical applications requiring consistent Sr2+-release, while the scaffold degrades in physiological medium. Statement of significance The study investigates the additive manufacturing of scaffolds based on different strontium-substituted magnesium phosphate bone cements by means of three-dimensional powder printing technique (3DPP). Magnesium phosphates were chosen due to their higher biodegradability compared to calcium phosphates, which is due to both a higher solubility as well as the absence of phase changes (to low soluble hydroxyapatite) in vivo. Since strontium ions are known to promote bone formation by stimulating osteoblast growth, we aimed to establish such a highly degradable magnesium phosphate ceramic with an enhanced bioactivity for new bone ingrowth. After post-processing, mechanical strengths of up to 36.7 MPa (compression), 24.2 MPa (bending) and 10.7 MPa (tension) could be achieved. Simultaneously, the failure reliability of those bioceramic implant materials, measured by Weibull modulus calculations, were in the range of 4.3-8.8. Passive dissolution studies in vitro proved an ion release of Mg2+ and PO43- as well as Sr2+, which is fundamental for in vivo degradation and a bone growth promoting effect. In our opinion, this work broadens the range of bioceramic bone replacement materials suitable for additive manufacturing processing. The high biodegradability of MPC ceramics together with the anticipated promoting effect on osseointegration opens up the way for a patient-specific treatment with the prospect of a fast and complete healing of bone fractures. (C) 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The degradation behavior and mechanical properties of polycaprolactone/nanohydroxyapatite composite scaffolds are studied in phosphate buffered solution (PBS), at 37 degrees C, over 16 weeks. Under scanning electron microscopy (SEM), it was observed that the longer the porous scaffolds remained in the PBS, the more significant the thickening of the pore walls of the scaffold morphology was. A decrease in the compressive properties, such as the modulus and the strength of the PCL/nHA composite scaffolds, was observed as the degradation experiment progressed. Samples with high nHA concentrations degraded more significantly in comparison to those with a lower content. Pure PCL retained its mechanical properties comparatively well in the study over the period of degradation. After the twelfth week, the results obtained by GPC analysis indicated a significant reduction in their molecular weight. The addition of nHA particles to the scaffolds accelerated the weight loss of the composites and increased their capacity to absorb water during the initial degradation process. The addition of these particles also affected the degradation behavior of the composite scaffolds, although they were not effective at compensating the decrease in pH prompted by the degradation products of the PCL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Psoriasis is a common, chronic and relapsing inflammatory skin disease. It affects approximately 2% of the western population and has no cure. Combination therapy for psoriasis often proves more efficacious and better tolerated than monotherapy with a single drug. Combination therapy could be administered in the form of a co-drug, where two or more therapeutic compounds active against the same condition are linked by a cleavable covalent bond. Similar to the pro-drug approach, the liberation of parent moieties post-administration, by enzymatic and/or chemical mechanisms, is a pre-requisite for effective treatment. In this study, a series of co-drugs incorporating dithranol in combination with one of several non-steroidal anti-inflammatory drugs, both useful for the treatment of psoriasis, were designed, synthesized and evaluated. An ester co-drug comprising dithranol and naproxen in a 1:1 stoichiometric ratio was determined to possess the optimal physicochemical properties for topical delivery. The co-drug was fully hydrolyzed in vitro by porcine liver esterase within four hours. When incubated with homogenized porcine skin, 9.5% of the parent compounds were liberated after 24 h, suggesting in situ esterase-mediated cleavage of the co-drug would occur within the skin. The kinetics of the reaction revealed first order kinetics, Vmax = 10.3 μM/min and Km = 65.1 μM. The co-drug contains a modified dithranol chromophore that was just 37% of the absorbance of dithranol at 375 nm and suggests reduced skin/clothes staining. Overall, these findings suggest that the dithranol-naproxen co-drug offers an attractive, novel approach for the treatment of psoriasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of polycaprolactone (PCL) as a biomaterial, especially in the fields of drug delivery and tissue engineering, has enjoyed significant growth. Understanding how such a device or scaffold eventually degrades in vivo is paramount as the defect site regenerates and remodels. Degradation studies of three-dimensional PCL and PCL-based composite scaffolds were conducted in vitro (in phosphate buffered saline) and in vivo (rabbit model). Results up to 6 months are reported. All samples recorded virtually no molecular weight changes after 6 months, with a maximum mass loss of only about 7% from the PCL-composite scaffolds degraded in vivo, and a minimum of 1% from PCL scaffolds. Overall, crystallinity increased slightly because of the effects of polymer recrystallization. This was also a contributory factor for the observed stiffness increment in some of the samples, while only the PCL-composite scaffold registered a decrease. Histological examination of the in vivo samples revealed good biocompatibility, with no adverse host tissue reactions up to 6 months. Preliminary results of medical-grade PCL scaffolds, which were implanted for 2 years in a critical-sized rabbit calvarial defect site, are also reported here and support our scaffold design goal for gradual and late molecular weight decreases combined with excellent long-term biocompatibility and bone regeneration. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res 90A: 906-919, 2009

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in vitro and in vivo degradation properties of poly(lactic-co-glycolic acid) (PLGA) scaffolds produced by two different technologies - thermally induced phase separation (TIPS), and solvent casting and particulate leaching (SCPL) were compared. Over 6 weeks, in vitro degradation produced changes in SCPL scaffold dimension, mass, internal architecture and mechanical properties. TIPS scaffolds produced far less changes in these parameters providing significant advantages over SCPL. In vivo results were based on a microsurgically created arteriovenous (AV) loop sandwiched between two TIPS scaffolds placed in a polycarbonate chamber under rat groin skin. Histologically, a predominant foreign body giant cell response and reduced vascularity was evident in tissue ingrowth between 2 and 8 weeks in TIPS scaffolds. Tissue death occurred at 8 weeks in the smallest pores. Morphometric comparison of TIPS and SCPL scaffolds indicated slightly better tissue ingrowth but greater loss of scaffold structure in SCPL scaffolds. Although advantageous in vitro, large surface area:volume ratios and varying pore sizes in PLGA TIPS scaffolds mean that effective in vivo (AV loop) utilization will only be achieved if the foreign body response can be significantly reduced so as to allow successful vascularisation, and hence sustained tissue growth, in pores less than 300 μm. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was carried out to determine the influence of fibrolytic enzymes derived from mesophilic or thermophilic fungal sources, added at ensiling, on time-course fermentation characteristics and in vitro rumen degradation of maize silage. The mesophilic enzyme was a commercial product derived from Trichodenna reesei (L), whereas the thermophilic enzyme was a crude extract produced from Thermoascus aurantiacus (Ta) in this laboratory. The fungus was cultured using maize cobs as a carbon source. The resulting fermentation extract was deionised to remove sugars and characterised for its protein concentration, main and side enzymic activities, optimal pH, protein molecular mass and isoelectric point. In an additional study, both enzymes were added to maize forage (333.5 g DM/kg, 70.0, 469.8, 227.1 and 307.5 g/kg DM of CP, NDF, ADF and starch, respectively) at two levels each, normalized according to xylanase activity, and ensiled in 0.5 kg capacity laboratory minisilos. Duplicate silos were opened at 2, 4, 8, 15, and 60 days after ensiling, and analysed for chemical characteristics. Silages from 60 days were bulked and in vitro gas production (GP) and organic matter degradability (OMD) profiles evaluated using the Reading Pressure Technique (RPT), in a completely randomised design. The crude enzyme extract contained mainly xylanase and endoglucanase activities, with very low levels of exoglucanase, which probably limited hydrolysis of filter paper. The extract contained three major protein bands of between 29 and 55 kDa, with mainly acidic isoelectric points. Ensiling maize with enzymes lowered (P < 0.05) the final silage pH, with this effect being observed throughout the ensiling process. All enzyme treatments reduced (P < 0.05) ADF contents. Treatments including Ta produced more gas (P < 0.05) than the controls after 24 h incubation in vitro, whereas end point gas production at 96 h was not affected. Addition of Ta increased (P < 0.01) OMD after 12 h (410 and 416 g/kg versus 373 g/kg), whereas both L and Ta increased (P < 0.05) OMD after 24 h. Addition of enzymes from mesophilic or thermophilic sources to maize forage at ensiling increased the rate of acidification of the silages and improved in vitro degradation kinetics, suggesting an improvement in the nutritive quality. (C) 2003 Elsevier B.V All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in vitro and in vivo degradation properties of poly(lactic-co-glycolic acid) (PLGA) scaffolds produced by two different technologies-therm ally induced phase separation (TIPS), and solvent casting and particulate leaching (SCPL) were compared. Over 6 weeks, in vitro degradation produced changes in SCPL scaffold dimension, mass, internal architecture and mechanical properties. TIPS scaffolds produced far less changes in these parameters providing significant advantages over SCPL. In vivo results were based on a microsurgically created arteriovenous (AV) loop sandwiched between two TIPS scaffolds placed in a polycarbonate chamber under rat groin skin. Histologically, a predominant foreign body giant cell response and reduced vascularity was evident in tissue ingrowth between 2 and 8 weeks in TIPS scaffolds. Tissue death occurred at 8 weeks in the smallest pores. Morphometric comparison of TIPS and SCPL scaffolds indicated slightly better tissue ingrowth but greater loss of scaffold structure in SCPL scaffolds. Although advantageous in vitro, large surface area:volume ratios and varying pore sizes in PLGA TIPS scaffolds mean that effective in vivo (AV loop) utilization will only be achieved if the foreign body response can be significantly reduced so as to allow successful vascularisation, and hence sustained tissue growth, in pores less than 300 mu m. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Centrifugal spinning is a novel fibre-forming process that readily permits the incorporation of additives while avoiding the thermal damage often associated with conventional melt spinning. Centrifugal spinning of a viscous solution of poly(3-hydroxybutyrate) (PHB) mixed with pectin was used to fabricate a range of fibres containing different concentrations of this biologically active agent. The influence of this blending on fibre morphology and in vitro degradation in an accelerated hydrolytic model at 70 ?C and pH of 10.6 is reported. RESULTS: Blending influenced the physiochemical properties of the fibres, andthis significantly affected thedegradation profile of both the fibre and its PHB constituent. A greater influence on degradation was exerted by the type of pectin and its degree of esterification than by variations in its loading. CONCLUSION: Centrifugal spinning permits the fabrication of composite fibrous matrices from PHB and pectin. Incorporation of the polysaccharide into the fibres can be used to manipulate degradation behaviour and demonstrates a model for doping of matrices with active biological constituents. The unique features of the centrifugal spinning process, as illustrated by the structure of the fibres and the degradation profiles, suggest possible applications of centrifugally spun biopolymers as wound scaffolding devices and in tissue engineering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EU]Polimero biobateragarri eta biodegradagarrien erabilera medikuntza arloan aurrerapauso handia suposatu du. Inplanteen arloan (torlojuak, iltzeak, plakak, eta abar…) eta ehun ingeniaritzan garrantzia handia dute. Hala ere, polimero hauen inplanteek desabantaila nabaria aurkezten dute ohiko material metalikoekin alderatuz: erradiopazitate eza. Ikerketa lan honetan karga erradiopako baten adizioak polimero biobateragarri eta biodegradagarri baten giza gorputzaren baldintzetan (pH=7,2 eta 37ºC) burututako in vitro degradazioan duen eragina aztertu da, %70 poli(L-laktida) (PLLA) eta %30 bario sulfato (BaSO4) sistemaren degradazioa, hain zuzen ere. Aztertutako karga erradiopakoak PLLAren degradazioan eragin handirik ez duela ondorioztatu da, beraz, sistema bideragarria dela.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study investigates the feasibility of using a biodegradable polymeric stent in common bile duct (CBD) repair and reconstruction. Here, poly(l-lactide-co-glycolide) (PLGA, molar ratio LA/GA = 80/20) was processed into a circular tube- and dumbbell-shaped specimens to determine the in vitro degradation behavior in bile. The morphology, weight loss, and molecular weight changes were then investigated in conjunction with evaluations of the mechanical properties of the specimen. Circular tube-shaped PLGA stents with X-ray opacity were subsequently used in common bile duct exploration (CBDE) and primary suturing in canine models. Next, X-ray images of CBD stents in vivo were compared and levels of serum liver enzymes and a histological analysis were conducted after stent transplantation. The results showed that the PLGA stents exhibited the required biomedical properties and spontaneously disappeared from CBDs in 4-5 weeks. The degradation period and function match the requirements in repair and reconstruction of CBDs to support the duct, guide bile drainage, and reduce T-tube-related complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The strength decrease in magnesium implants was studied in vitro and in vivo, with and without a protective plasmaelectrolytic coating. In vivo, degradation was examined by implanting rectangular plates on top of the nasal bone of miniature pigs. The presence of gas pockets in the soft tissue surrounding the implants was evaluated with intermediate X-rays and computed X-ray tomography scans before euthanasia. After 12 and 24weeks of in vivo degradation, the large rectangular plates were removed and mechanically tested in three-point bending. In vitro, identical plates were immersed in simulated body fluid for 4, 8 and 12weeks. In vitro and in vivo results showed that onset of gas release can be delayed by the plasmaelectrolytic coating. Mass loss and strength retention during in vivo degradation is about four times slower than during in vitro degradation for the chosen test conditions. Despite the slow degradation of the investigated WE43 alloy, the occurrence of gas pockets could not be completely avoided. Nevertheless, uniformity of degradation and reliable strength retention make this alloy a prime candidate for the use of magnesium in cranio-maxillofacial surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing use of biodegradable devices in tissue engineering and regenerative medicine means it is essential to study and understand their degradation behaviour. Accelerated degradation systems aim to achieve similar degradation profiles within a shorter period of time, compared with standard conditions. However, these conditions only partially mimic the actual situation, and subsequent analyses and derived mechanisms must be treated with caution and should always be supported by actual long-term degradation data obtained under physiological conditions. Our studies revealed that polycaprolactone (PCL) and PCL-composite scaffolds degrade very differently under these different degradation conditions, whilst still undergoing hydrolysis. Molecular weight and mass loss results differ due to the different degradation pathways followed (surface degradation pathway for accelerated conditions and bulk degradation pathway for simulated physiological conditions). Crystallinity studies revealed similar patterns of recrystallization dynamics, and mechanical data indicated that the scaffolds retained their functional stability, in both instances, over the course of degradation. Ultimately, polymer degradation was shown to be chiefly governed by molecular weight, crystallinity susceptibility to hydrolysis and device architecture considerations whilst maintaining its thermodynamic equilibrium.